916 resultados para Air - Pollution
Resumo:
An economic air pollution control model, which determines the least cost of reaching various air quality levels, is formulated. The model takes the form of a general, nonlinear, mathematical programming problem. Primary contaminant emission levels are the independent variables. The objective function is the cost of attaining various emission levels and is to be minimized subject to constraints that given air quality levels be attained.
The model is applied to a simplified statement of the photochemical smog problem in Los Angeles County in 1975 with emissions specified by a two-dimensional vector, total reactive hydrocarbon, (RHC), and nitrogen oxide, (NOx), emissions. Air quality, also two-dimensional, is measured by the expected number of days per year that nitrogen dioxide, (NO2), and mid-day ozone, (O3), exceed standards in Central Los Angeles.
The minimum cost of reaching various emission levels is found by a linear programming model. The base or "uncontrolled" emission levels are those that will exist in 1975 with the present new car control program and with the degree of stationary source control existing in 1971. Controls, basically "add-on devices", are considered here for used cars, aircraft, and existing stationary sources. It is found that with these added controls, Los Angeles County emission levels [(1300 tons/day RHC, 1000 tons /day NOx) in 1969] and [(670 tons/day RHC, 790 tons/day NOx) at the base 1975 level], can be reduced to 260 tons/day RHC (minimum RHC program) and 460 tons/day NOx (minimum NOx program).
"Phenomenological" or statistical air quality models provide the relationship between air quality and emissions. These models estimate the relationship by using atmospheric monitoring data taken at one (yearly) emission level and by using certain simple physical assumptions, (e. g., that emissions are reduced proportionately at all points in space and time). For NO2, (concentrations assumed proportional to NOx emissions), it is found that standard violations in Central Los Angeles, (55 in 1969), can be reduced to 25, 5, and 0 days per year by controlling emissions to 800, 550, and 300 tons /day, respectively. A probabilistic model reveals that RHC control is much more effective than NOx control in reducing Central Los Angeles ozone. The 150 days per year ozone violations in 1969 can be reduced to 75, 30, 10, and 0 days per year by abating RHC emissions to 700, 450, 300, and 150 tons/day, respectively, (at the 1969 NOx emission level).
The control cost-emission level and air quality-emission level relationships are combined in a graphical solution of the complete model to find the cost of various air quality levels. Best possible air quality levels with the controls considered here are 8 O3 and 10 NO2 violations per year (minimum ozone program) or 25 O3 and 3 NO2 violations per year (minimum NO2 program) with an annualized cost of $230,000,000 (above the estimated $150,000,000 per year for the new car control program for Los Angeles County motor vehicles in 1975).
Resumo:
IEECAS SKLLQG
Elemental carbon in urban soils and road dusts in Xi'an, China and its implication for air pollution
Resumo:
Grattan J.P., Rabartin, R., Self, S. & Thordarson, Th. 2005. Volcanic air pollution and mortality in France 1783-84. Comptes Rendu Geosciences. 641-651 This item is available in both English and French in the PDF file.
Resumo:
Air pollution is a common problem. Particulate matter generated from air pollution has been tied to adverse health outcomes associated with cardiovascular disease. Biomass fuels are a specific contributor to increased particulate matter and arise as a result of indoor heating, cook stoves and indoor food preparation. This is a two part cross sectional study looking at communities in the Madre de Dios region. Survey data was collected from 9 communities along the Madre de Dios River. Individual level household PM2.5 was also collected as a means to generate average PM data stratified by fuel use. Data collection was affected by a number of outside factors, which resulted in a loss of data. Results from the cross-sectional study indicate that hypertension is not a significant source of morbidity. Obesity is prevalent and significantly associated with kitchen venting method indicating a potential relationship.
Resumo:
The strong spatial and temporal variability of traffic-related air pollution detected at roadside locations in a number of European cities has raised the question of how representative the site and time period of air quality measurements actually can be. To address this question, a 7-month sampling campaign was carried out on a major road axis (Avenue Leclerc) leading to a very busy intersection (Place Basch) in central Paris, covering the surroundings of a permanent air quality monitoring station. This station has recorded the highest CO and NOx concentrations during recent years in the region of Paris. Diffusive BTX samplers as well as a mobile monitoring unit equipped with real-time CO, NOx and O3 analysers and meteorological instruments were used to reveal the small-scale pollution gradients and their temporal trends near the permanent monitoring station. The diffusive measurements provided 7-day averages of benzene, toluene, xylene and other hydrocarbons at different heights above the ground and distances from the kerb covering summer and winter periods. Relevant traffic and meteorological data were also obtained on an hourly basis. Furthermore, three semiempirical dispersion models (STREET-SRI, OSPM and AEOLIUS) were tested for an asymmetric canyon location in Av. Leclerc. The analysis of this comprehensive data set has helped to assess the representativeness of air quality monitoring information.
Resumo:
Se estudia la influencia de los siguientes factores sobre el valor del cociente de feofitinización DO 435 nm/DO 415 nm en el líquen Anaptychia ciliaris (L.) Kórber: edad del líquen, concentración final de pigmentos, trasplante de los líquenes a áreas distintas sobre sustratos diferentes o similares y el valor de pH del sustrato original o el adoptado tras el trasplante. Se discute la utilización de A. ciliaris como un bioindicador de la presencia de factorcs acidificantes en la atmósfera o en el agua de lluvia que provoquen la feofitinización de las clorofilas.