890 resultados para Advanced DInSAR analysis
Resumo:
Laser interferometer gravitational wave observatory (LIGO) consists of two complex large-scale laser interferometers designed for direct detection of gravitational waves from distant astrophysical sources in the frequency range 10Hz - 5kHz. Direct detection of space-time ripples will support Einstein's general theory of relativity and provide invaluable information and new insight into physics of the Universe.
Initial phase of LIGO started in 2002, and since then data was collected during six science runs. Instrument sensitivity was improving from run to run due to the effort of commissioning team. Initial LIGO has reached designed sensitivity during the last science run, which ended in October 2010.
In parallel with commissioning and data analysis with the initial detector, LIGO group worked on research and development of the next generation detectors. Major instrument upgrade from initial to advanced LIGO started in 2010 and lasted till 2014.
This thesis describes results of commissioning work done at LIGO Livingston site from 2013 until 2015 in parallel with and after the installation of the instrument. This thesis also discusses new techniques and tools developed at the 40m prototype including adaptive filtering, estimation of quantization noise in digital filters and design of isolation kits for ground seismometers.
The first part of this thesis is devoted to the description of methods for bringing interferometer to the linear regime when collection of data becomes possible. States of longitudinal and angular controls of interferometer degrees of freedom during lock acquisition process and in low noise configuration are discussed in details.
Once interferometer is locked and transitioned to low noise regime, instrument produces astrophysics data that should be calibrated to units of meters or strain. The second part of this thesis describes online calibration technique set up in both observatories to monitor the quality of the collected data in real time. Sensitivity analysis was done to understand and eliminate noise sources of the instrument.
Coupling of noise sources to gravitational wave channel can be reduced if robust feedforward and optimal feedback control loops are implemented. The last part of this thesis describes static and adaptive feedforward noise cancellation techniques applied to Advanced LIGO interferometers and tested at the 40m prototype. Applications of optimal time domain feedback control techniques and estimators to aLIGO control loops are also discussed.
Commissioning work is still ongoing at the sites. First science run of advanced LIGO is planned for September 2015 and will last for 3-4 months. This run will be followed by a set of small instrument upgrades that will be installed on a time scale of few months. Second science run will start in spring 2016 and last for about 6 months. Since current sensitivity of advanced LIGO is already more than factor of 3 higher compared to initial detectors and keeps improving on a monthly basis, upcoming science runs have a good chance for the first direct detection of gravitational waves.
Resumo:
Background: Recently, with the access of low toxicity biological and targeted therapies, evidence of the existence of a long-term survival subpopulation of cancer patients is appearing. We have studied an unselected population with advanced lung cancer to look for evidence of multimodality in survival distribution, and estimate the proportion of long-term survivors. Methods: We used survival data of 4944 patients with non-small-cell lung cancer (NSCLC) stages IIIb-IV at diagnostic, registered in the National Cancer Registry of Cuba (NCRC) between January 1998 and December 2006. We fitted one-component survival model and two-component mixture models to identify short-and long-term survivors. Bayesian information criterion was used for model selection. Results: For all of the selected parametric distributions the two components model presented the best fit. The population with short-term survival (almost 4 months median survival) represented 64% of patients. The population of long-term survival included 35% of patients, and showed a median survival around 12 months. None of the patients of short-term survival was still alive at month 24, while 10% of the patients of long-term survival died afterwards. Conclusions: There is a subgroup showing long-term evolution among patients with advanced lung cancer. As survival rates continue to improve with the new generation of therapies, prognostic models considering short-and long-term survival subpopulations should be considered in clinical research.
Analysis of deformation behavior and workability of advanced 9Cr-Nb-V ferritic heat resistant steels
Resumo:
Hot compression tests were carried out on 9Cr–Nb–V heat resistant steels in the temperature range of 600–1200 °C and the strain rate range of 10−2–100 s−1 to study their deformation characteristics. The full recrystallization temperature and the carbon-free bainite phase transformation temperature were determined by the slope-change points in the curve of mean flow stress versus the inverse of temperature. The parameters of the constitutive equation for the experimental steels were calculated, including the stress exponent and the activation energy. The lower carbon content in steel would increase the fraction of precipitates by increasing the volume of dynamic strain-induced (DSIT) ferrite during deformation. The ln(εc) versus ln(Z) and the ln(σc) versus ln(Z) plots for both steels have similar trends. The efficiency of power dissipation maps with instability maps merged together show excellent workability from the strain of 0.05 to 0.6. The microstructure of the experimental steels was fully recrystallized upon deformation at low Z value owing to the dynamic recrystallization (DRX), and exhibited a necklace structure under the condition of 1050 °C/0.1 s−1 due to the suppression of the secondary flow of DRX. However, there were barely any DRX grains but elongated pancake grains under the condition of 1000 °C/1 s−1 because of the suppression of the metadynamic recrystallization (MDRX).
Resumo:
Objective This study explores men with advanced prostate cancers’ own practices for promoting and maintaining emotional well-being using Interpretative Phenomenological Analysis. Design Five men with advanced prostate cancer participated in face-to-face, semi-structured, in-depth interviews. Results Within rich narratives of lost and regained well-being, two super-ordinate themes emerged – ‘living with an imminent and uncertain death’ and ‘holding on to life.’ Well-being was threatened by reduced sense of the future, isolation and uncertainty. Yet, the men pursued well-being by managing their emotions, striving for the future whilst enjoying life in the present, taking care of their families and renegotiating purpose. Running through participant’s accounts was a preference for taking action and problem-solving. Sense of purpose, social connectedness and life-engagement were revealed as concepts central to improving well-being, indicating areas which practitioners could explore with men to help them re-establish personal goals and life-purpose. Conclusions The findings also add weight to the evidence base for the potential value of psychological interventions such as cognitive behaviour therapy and mindfulness in men with prostate cancer.
Resumo:
Phenolic compounds in wastewaters are difficult to treat using the conventional biological techniques such as activated sludge processes because of their bio-toxic and recalcitrant properties and the high volumes released from various chemical, pharmaceutical and other industries. In the current work, a modified heterogeneous advanced Fenton process (AFP) is presented as a novel methodology for the treatment of phenolic wastewater. The modified AFP, which is a combination of hydrodynamic cavitation generated using a liquid whistle reactor and the AFP is a promising technology for wastewaters containing high organic content. The presence of hydrodynamic cavitation in the treatment scheme intensifies the Fenton process by generation of additional free radicals. Also, the turbulence produced during the hydrodynamic cavitation process increases the mass transfer rates as well as providing better contact between the pseudo-catalyst surfaces and the reactants. A multivariate design of experiments has been used to ascertain the influence of hydrogen peroxide dosage and iron catalyst loadings on the oxidation performance of the modified AFP. High er TOC removal rates were achieved with increased concentrations of hydrogen peroxide. In contrast, the effect of catalyst loadings was less important on the TOC removal rate under conditions used in this work although there is an optimum value of this parameter. The concentration of iron species in the reaction solution was measured at 105 min and its relationship with the catalyst loadings and hydrogen peroxide level is presented.
Resumo:
This report describes the analysis and development of novel tools for the global optimisation of relevant mission design problems. A taxonomy was created for mission design problems, and an empirical analysis of their optimisational complexity performed - it was demonstrated that the use of global optimisation was necessary on most classes and informed the selection of appropriate global algorithms. The selected algorithms were then applied to the di®erent problem classes: Di®erential Evolution was found to be the most e±cient. Considering the speci¯c problem of multiple gravity assist trajectory design, a search space pruning algorithm was developed that displays both polynomial time and space complexity. Empirically, this was shown to typically achieve search space reductions of greater than six orders of magnitude, thus reducing signi¯cantly the complexity of the subsequent optimisation. The algorithm was fully implemented in a software package that allows simple visualisation of high-dimensional search spaces, and e®ective optimisation over the reduced search bounds.
Resumo:
The advent of the Auger Engineering Radio Array (AERA) necessitates the development of a powerful framework for the analysis of radio measurements of cosmic ray air showers. As AERA performs ""radio-hybrid"" measurements of air shower radio emission in coincidence with the surface particle detectors and fluorescence telescopes of the Pierre Auger Observatory, the radio analysis functionality had to be incorporated in the existing hybrid analysis solutions for fluorescence and surface detector data. This goal has been achieved in a natural way by extending the existing Auger Offline software framework with radio functionality. In this article, we lay out the design, highlights and features of the radio extension implemented in the Auger Offline framework. Its functionality has achieved a high degree of sophistication and offers advanced features such as vectorial reconstruction of the electric field, advanced signal processing algorithms, a transparent and efficient handling of FFTs, a very detailed simulation of detector effects, and the read-in of multiple data formats including data from various radio simulation codes. The source code of this radio functionality can be made available to interested parties on request. (C) 2011 Elsevier B.V. All rights reserved.
Resumo:
Objective: To compare results from various tapping tests with diary responses in advanced PD. Background: A home environment test battery for assessing patient state in advanced PD, consisting of diary assessments and motor tests was constructed for a hand computer with touch screen and mobile communication. The diary questions: 1. walking, 2. time in off , on and dyskinetic states, 3. off at worst, 4. dyskinetic at worst, 5. cramps, and 6. satisfied with function, relate to the recent past. Question 7, self-assessment, allows seven steps from -3 ( very off ) to +3 ( very dyskinetic ) and relate to right now. Tapping tests outline: 8. Alternately tapping two fields (un-cued) with right hand 9. Same as 8 but using left hand 10. Tapping an active field (out of two) following a system-generated rhythm (increasing speed) with the dominant hand 11. Tapping an active field (out of four) that randomly changes location when tapped using the dominant hand Methods: 65 patients (currently on Duodopa, or candidates for this treatment) entered diary responses and performed tapping tests four times per day during one to six periods of seven days length. In total there were 224 test periods and 6039 test occasions. Speed for tapping test 10 was discardedand tests 8 and 9 were combined by taking means. Descriptive statistics were used to present the variation of the test variables in relation to self assessment (question 7). Pearson correlation coefficients between speed and accuracy (percent correct) in tapping tests and diary responses were calculated. Results: Mean compliance (percentage completed test occasions per test period) was 83% and the median was 93%. There were large differences in both mean tapping speed and accuracy between the different self-assessed states. Correlations between diary responses and tapping results were small (-0.2 to 0.3, negative values for off-time and dyskinetic-time that had opposite scale directions). Correlations between tapping results were all positive (0.1 to 0.6). Conclusions: The diary responses and tapping results provided different information. The low correlations can partly be explained by the fact that questions related to the past and by random variability, which could be reduced by taking means over test periods. Both tapping speed and accuracy reflect the motor function of the patient to a large extent.
Resumo:
To evaluate the tumor response to neoadjuvant chemotherapy, Tc-99m-sestamibi breast scintigraphy was proposed as a quantitative method Fifty-five patients with ductal carcinoma were studied They underwent breast scintigraphy before and after neoadjuvant chemotherapy, along with clinical assessment and surgical specimen analysis The regions of interest on the lesion and contralateral breast were identified, and the pixel counts were used to evaluate lesion uptake in relation to background radiation The ratio of these counts before to after neoadjuvant chemotherapy was assessed The decrease in uptake rate due to chemotherapy characterized the scintigraphy tumor response The Kruskal-Wallis test was used to compare the mean scintigraphic tumor response and histological type Dunn's multiple comparison test was used to detect differences between histological types The Mann-Whitney test was used to compare means between quantitative and qualitative variables scintigraphic tumor response vs clinical response and uptake before chemotherapy vs scintigraphic tumor response The Spearman's test was used to correlate the quantitative variables of clinical reduction in tumor size and scintigraphic tumor response All of the variables compared presented significant differences The change in Tc-99m-sestamibi uptake noted on breast scintigraphy, before to after neoadjuvant chemotherapy, may be used as an effective method for evaluating the response to neoadjuvant chemotherapy, since this quantification reflects the biological behavior of the tumor towards the chemotherapy regimen Furthermore, additional analysis on the uptake rate before chemotherapy may accurately predict treatment response