965 resultados para Activated-sludge Process


Relevância:

100.00% 100.00%

Publicador:

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Microbiological quality of the treated wastewater is an important parameter for its reuse. The data oil the Fecal Coliform (FC) and Fecal Streptococcus (FS) at different stages of treatment in the Sewage Treatment Plants (STPs) in Delhi watershed is not available, therefore in the present study microbial profiling of STPs was carried out to assess the effluent quality for present and future reuse options. This Study further evaluates the water quality profiles at different stages of treatment for 16 STPs in Delhi city. These STPs are based on conventional Activated Sludge Process (ASP), extended aeration, physical, chemical and biological treatment (BIOFORE), Trickling Filter and Oxidation Pond. The primary effluent quality produced from most of the STPs was suitable for Soil Aquifer Treatment (SAT). Extended Hydraulic Retention Time (HRT) as a result Of low inflow to the STPS Was responsible for high turbidity, COD and BODs removal. Conventional ASP based STPs achieved 1.66 log FC and 1.06 log FS removal. STPs with extended aeration treatment process produced better quality effluent with maximum 4 log order reduction in FC and FS levels. ``Kondli'' and ``Nilothi'' STPs employing ASP, produced better quality secondary effluent as compared to other STPs based oil similar treatment process. Oxidation Pond based STPs showed better FC and FS removals, whereas good physiochemical quality was achieved during the first half of the treatment. Based upon physical, chemical and microbiological removal efficiencies, actual integrated efficiency (IEa) of each STP was determined to evaluate its Suitability for reuse for irrigation purposes. Except Mehrauli'' and ``Oxidation Pond'', effluents from all other STPs require tertiary treatment for further reuse. Possible reuse options, depending Upon the geographical location, proximity of facilities of potential users based oil the beneficial uses, and sub-soil types, etc. for the Delhi city have been investigated, which include artificial groundwater recharge, aquaculture, horticulture and industrial uses Such as floor washing, boiler feed, and cooling towers, etc. (C) 2009 Elsevier B.V. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

O processo de lodos ativados consiste em um tratamento biológico amplamente utilizado nas estações de tratamento, para remoção de matéria orgânica, devido à qualidade do efluente ao final do processo. Essa remoção é realizada por microrganismos que atuam neste sistema como bactérias, protozoários, metazoários e organismos filamentosos, como fungos e bactérias, formadores de flocos biológicos. Para garantir a eficiência deste processo deve haver um equilíbrio da microbiota dentro do reator aeróbio e o controle do número de filamentosos, tendo em vista que seu excesso no sistema pode causar o intumescimento do lodo (bulking) interferindo na qualidade do efluente gerado. O presente estudo teve como objetivo testar a eficiência de uma solução de 0,001% de peróxido de hidrogênio (H2O2) no controle de microrganismos filamentosos em lodos provenientes de duas indústrias, farmacêutica e alimentícia, reduzindo assim os riscos relacionados à utilização desta substância em grandes volumes. Foram realizadas análises microscópicas do lodo para avaliação quantitativa e monitoramento da atividade biológica dos reatores, essa avaliação serviu como base para a análise qualitativa a partir do índice de Madoni (1994) gerando um Índice Biótico do Lodo (IBL). Foram realizados outros testes, como IVL e teste de respiração, sendo os resultados destes testes comparados a fim de avaliar a eficiência da solução de H2O2 e sua interferência no processo. A solução de H2O2 foi eficiente em ambos os experimentos, mostrando através dos testes de TCO e TCOe não haver interferência desta solução no metabolismo da microfauna; os resultados do IBL mostraram uma boa qualidade do lodo para ambos experimentos e a partir desta análise foi observado que a elevação de temperatura, acima de 30,0C, causa interferência no sistema levando a uma redução do IBL. Os resultados de IVL não demonstraram diferença entre os valores dos reatores controle e tratado, porém a avaliação do tamanho dos flocos e filamentos mostrou que o aumento na concentração da solução de H2O2 levou a um controle na quantidade de filamentosos nos reatores tratados que reduziram em tamanho e quantidade.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Textile wastewater is commonly treated with activated sludge process technology. However, its treatment performance has not been demonstrated to be very effective. In this study, the effects of micronutrient thiamine on removal efficiencies of dissolved organic carbon (DOC) and chemical oxygen demand (COD) of textile wastewater in a batch test, together with its effect on the oxygen uptake rate (OUR) of activated sludge, were evaluated. Significant improvements were observed in the removal rates of DOC, COD and OUR with 121%, 156% and 121% of those of the control, respectively, when 0.5-2.0 mg/L thiamine was added to the wastewater treatment system. Thiamine could be probably used to improve the treatment performance of textile wastewater.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Dissertation presented to obtain the Ph.D degree in Engineering and Technology Sciences, Biotechnology.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Dissertation to obtain the degree of Master in Chemical and Biochemical Engineering

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Many of the existing methods for the treatment of rubber latex centrifugation eflluent are not only unsatisfactory in their efliciency to effect near perfect treatment in bringing down the COD to optimum level, but also time consuming and need a large landspace. As the rate of effluent generation is extremely high (20 litres for kilogram of rubber) there is a need for development of efficient system,capable of rapid reduction of COD and BOD. Though the organic load of the rubber efiluent is very high, it does not contain much processed chemicals and therefore it can be considered as a ‘biological eflluent’. Further, the ratio of the Chemical Oxygen Demand to Biological Oxygen Demand (COD/BOD) of this effluent remain almost as a constant value. According to Montgomery (1967), estimation of BOD is not ideally suited for studies on process design, treatability, control of treatment plants, setting standards for treated effluents and assessing the effect of polluting discharges on the oxygen resources of receiving waters. Hence in the present study COD was measured to determine the impact of treatment system on the effluent. In the present study, attempts were made to evaluate the efficiencies of certain methods such as packed bed reactor using immobilized microbial cells, rotating biological contactor (RBC) and activated sludge process, for rapid and efficient treatment of natural rubber latex centrifugation effluent. In addition, studies were also carn'ed out to develop a suitable bioprocess for the coagulation of skim latex, as an alternative to the presently used acid coagulation process towards reducing the pollution load, besides recovering quality rubber

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Effective solids-liquid separation is the basic concept of any wastewater treatment system. Biological treatment methods involve microorganisms for the treatment of wastewater. Conventional activated sludge process (ASP) poses the problem of poor settleability and hence require a large footprint. Biogranulation is an effective biotechnological process which can overcome the drawbacks of conventional ASP to a great extent. Aerobic granulation represents an innovative cell immobilization strategy in biological wastewater treatment. Aerobic granules are selfimmobilized microbial aggregates that are cultivated in sequencing batch reactors (SBRs). Aerobic granules have several advantages over conventional activated sludge flocs such as a dense and compact microbial structure, good settleability and high biomass retention. For cells in a culture to aggregate, a number of conditions have to be satisfied. Hence aerobic granulation is affected by many operating parameters. The organic loading rate (OLR) helps to enrich different bacterial species and to influence the size and settling ability of granules. Hence, OLR was argued as an influencing parameter by helping to enrich different bacterial species and to influence the size and settling ability of granules. Hydrodynamic shear force, caused by aeration and measured as superficial upflow air velocity (SUAV), has a strong influence and hence it is used to control the granulation process. Settling time (ST) and volume exchange ratio (VER) are also two key influencing factors, which can be considered as selection pressures responsible for aerobic granulation based on the concept of minimal settling velocity. Hence, these four parameters - OLR, SUAV, ST and VER- were selected as major influencing parametersfor the present study. Influence of these four parameters on aerobic granulation was investigated in this work

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Estudi de tractaments innovadors en aigües residuals amb elevada concentració de nitrogen mitjançant la tecnologia ANAMMOX (Anaerobic Ammonium Oxidation) i SHARON i posterior anàlisi teòrica de la gestió dels fangs residuals d’una EDAR

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The control and prediction of wastewater treatment plants poses an important goal: to avoid breaking the environmental balance by always keeping the system in stable operating conditions. It is known that qualitative information — coming from microscopic examinations and subjective remarks — has a deep influence on the activated sludge process. In particular, on the total amount of effluent suspended solids, one of the measures of overall plant performance. The search for an input–output model of this variable and the prediction of sudden increases (bulking episodes) is thus a central concern to ensure the fulfillment of current discharge limitations. Unfortunately, the strong interrelation between variables, their heterogeneity and the very high amount of missing information makes the use of traditional techniques difficult, or even impossible. Through the combined use of several methods — rough set theory and artificial neural networks, mainly — reasonable prediction models are found, which also serve to show the different importance of variables and provide insight into the process dynamics