896 resultados para ADAMS-TYPE CYCLIC METHODS


Relevância:

40.00% 40.00%

Publicador:

Resumo:

"March 1980."

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Based on optical imaging and spectroscopy of the Type II-Plateau SN 2013eq, we present a comparative study of commonly used distance determination methods based on Type II supernovae. The occurrence of SN 2013eq in the Hubble flow (z = 0.041 ± 0.001) prompted us to investigate the implications of the difference between "angular" and "luminosity" distances within the framework of the expanding photosphere method (EPM) that relies upon a relation between flux and angular size to yield a distance. Following a re-derivation of the basic equations of the EPM for SNe at non-negligible redshifts, we conclude that the EPM results in an angular distance. The observed flux should be converted into the SN rest frame and the angular size, θ, has to be corrected by a factor of (1 + z)2. Alternatively, the EPM angular distance can be converted to a luminosity distance by implementing a modification of the angular size. For SN 2013eq, we find EPM luminosity distances of DL = 151 ± 18 Mpc and DL = 164 ± 20 Mpc by making use of different sets of dilution factors taken from the literature. Application of the standardized candle method for Type II-P SNe results in an independent luminosity distance estimate (DL = 168 ± 16 Mpc) that is consistent with the EPM estimate. Spectra of SN 2013eq are available in the Weizmann Interactive Supernova data REPository (WISeREP): http://wiserep.weizmann.ac.il

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The intrinsic gas-phase reactivity of cyclic N-acyliminium ions in Mannich-type reactions with the parent enol silane, vinyloxytrimethylsilane, has been investigated by double- and triple-stage pentaquadrupole mass spectrometric experiments. Remarkably distinct reactivities are observed for cyclic N-acyliminium ions bearing either endocyclic or exocyclic carbonyl groups. NH-Acyliminium ions with endocyclic carbonyl groups locked in s-trans forms participate in a novel tandem N-acyliminium ion reaction:  the nascent adduct formed by simple addition is unstable and rearranges by intramolecular trimethylsilyl cation shift to the ring nitrogen, and an acetaldehyde enol molecule is eliminated. An NSi(CH3)3-acyliminium ion is formed, and this intermediate ion reacts with a second molecule of vinyloxytrimethylsilane by simple addition to form a stable acyclic adduct. N-Acyl and N,N-diacyliminium ions with endocyclic carbonyl groups, for which the s-cis conformation is favored, react distinctively by mono polar [4+ + 2] cycloaddition yielding stable, ressonance-stabilized cycloadducts. Product ions were isolated via mass-selection and structurally characterized by triple-stage mass spectrometric experiments. B3LYP/6-311G(d,p) calculations corroborate the proposed reaction mechanisms.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

For climate risk management, cumulative distribution functions (CDFs) are an important source of information. They are ideally suited to compare probabilistic forecasts of primary (e.g. rainfall) or secondary data (e.g. crop yields). Summarised as CDFs, such forecasts allow an easy quantitative assessment of possible, alternative actions. Although the degree of uncertainty associated with CDF estimation could influence decisions, such information is rarely provided. Hence, we propose Cox-type regression models (CRMs) as a statistical framework for making inferences on CDFs in climate science. CRMs were designed for modelling probability distributions rather than just mean or median values. This makes the approach appealing for risk assessments where probabilities of extremes are often more informative than central tendency measures. CRMs are semi-parametric approaches originally designed for modelling risks arising from time-to-event data. Here we extend this original concept beyond time-dependent measures to other variables of interest. We also provide tools for estimating CDFs and surrounding uncertainty envelopes from empirical data. These statistical techniques intrinsically account for non-stationarities in time series that might be the result of climate change. This feature makes CRMs attractive candidates to investigate the feasibility of developing rigorous global circulation model (GCM)-CRM interfaces for provision of user-relevant forecasts. To demonstrate the applicability of CRMs, we present two examples for El Ni ? no/Southern Oscillation (ENSO)-based forecasts: the onset date of the wet season (Cairns, Australia) and total wet season rainfall (Quixeramobim, Brazil). This study emphasises the methodological aspects of CRMs rather than discussing merits or limitations of the ENSO-based predictors.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The finite element and boundary element methods are employed in this study to investigate the sound radiation characteristics of a box-type structure. It has been shown [T.R. Lin, J. Pan, Vibration characteristics of a box-type structure, Journal of Vibration and Acoustics, Transactions of ASME 131 (2009) 031004-1–031004-9] that modes of natural vibration of a box-type structure can be classified into six groups according to the symmetry properties of the three panel pairs forming the box. In this paper, we demonstrate that such properties also reveal information about sound radiation effectiveness of each group of modes. The changes of radiation efficiencies and directivity patterns with the wavenumber ratio (the ratio between the acoustic and the plate bending wavenumbers) are examined for typical modes from each group. Similar characteristics of modal radiation efficiencies between a box structure and a corresponding simply supported panel are observed. The change of sound radiation patterns as a function of the wavenumber ratio is also illustrated. It is found that the sound radiation directivity of each box mode can be correlated to that of elementary sound sources (monopole, dipole, etc.) at frequencies well below the critical frequency of the plates of the box. The sound radiation pattern on the box surface also closely related to the vibration amplitude distribution of the box structure at frequencies above the critical frequency. In the medium frequency range, the radiated sound field is dominated by the edge vibration pattern of the box. The radiation efficiency of all box modes reaches a peak at frequencies above the critical frequency, and gradually approaches unity at higher frequencies.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background: Subjects with type 2 diabetes have high circulating levels of glucose. Glucagon-like peptide-1 (GLP-1) is an intestinal hormone that has a major role in glucose homeostasis. Exenatide and liraglutide are both agonists at the GLP-1 receptor, and are effective at reducing circulating glucose levels (measured as HbA1c levels), but they have not been compared. Objectives/methods: This evaluation is of a clinical trial comparing liraglutide once a day with exenatide twice a day in subjects with type 2 diabetes. Results: In the Liraglutide Effect and Action in Diabetes (LEAD)-6 trial, subcutaneous liraglutide 1.8 mg once a day was compared with exenatide 10 μg twice a day. The primary efficacy outcome was change in HbA1c levels, and this was significantly greater with liraglutide (1.12%) than with exenatide (0.79%). Liraglutide and exenatide had similar small abilities to reduce body weight, blood pressure and LDL-cholesterol. Conclusions: Liraglutide was more effective than exenatide for overall glycaemic control in subjects with type 2 diabetes. However, this is only true for the preparations and doses tested, that is liraglutide 1.8 mg once weekly and exenatide 10 μg b.i.d., and may not apply when the comparison is undertaken with the new longer-lasting preparation of exenatide once weekly.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The redox potentials of 25 cyclic nitroxides from four different structural classes (pyrrolidine, piperidine, isoindoline, and azaphenalene) were determined experimentally by cyclic voltammetry in acetonitrile, and also via high-level ab initio molecular orbital calculations. It is shown that the potentials are influenced by the type of ring system, ring substituents and/or groups surrounding the radical moiety. For the pyrrolidine, piperidine, and isoindolines there is excellent agreement (mean absolute deviation of 0.05 V) between the calculated and experimental oxidation potentials; for the azaphenalenes, however, there is an extraordinary discrepancy (mean absolute deviation of 0.60 V), implying that their one-electron oxidation might involve additional processes not considered in the theoretical calculations. This recently developed azaphenalene class of nitroxide represents a new variant of a nitroxide ring fused to an aromatic system and details of the synthesis of five derivatives involving differing aryl substitution are also presented.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Studies have examined the associations between cancers and circulating 25-hydroxyvitamin D [25(OH)D], but little is known about the impact of different laboratory practices on 25(OH)D concentrations. We examined the potential impact of delayed blood centrifuging, choice of collection tube, and type of assay on 25(OH)D concentrations. Blood samples from 20 healthy volunteers underwent alternative laboratory procedures: four centrifuging times (2, 24, 72, and 96 h after blood draw); three types of collection tubes (red top serum tube, two different plasma anticoagulant tubes containing heparin or EDTA); and two types of assays (DiaSorin radioimmunoassay [RIA] and chemiluminescence immunoassay [CLIA/LIAISON®]). Log-transformed 25(OH)D concentrations were analyzed using the generalized estimating equations (GEE) linear regression models. We found no difference in 25(OH)D concentrations by centrifuging times or type of assay. There was some indication of a difference in 25(OH)D concentrations by tube type in CLIA/LIAISON®-assayed samples, with concentrations in heparinized plasma (geometric mean, 16.1 ng ml−1) higher than those in serum (geometric mean, 15.3 ng ml−1) (p = 0.01), but the difference was significant only after substantial centrifuging delays (96 h). Our study suggests no necessity for requiring immediate processing of blood samples after collection or for the choice of a tube type or assay.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Purpose: To investigate whether wearing different presbyopic vision corrections alters the pattern of eye and head movements when viewing dynamic driving-related traffic scenes. Methods: Participants included 20 presbyopes (mean age: 56±5.7 years) who had no experience of wearing presbyopic vision corrections (i.e. all were single vision wearers). Eye and head movements were recorded while wearing five different vision corrections: single vision lenses (SV), progressive addition spectacle lenses (PALs), bifocal spectacle lenses (BIF), monovision (MV) and multifocal contact lenses (MTF CL) in random order. Videotape recordings of traffic scenes of suburban roads and expressways (with edited targets) were presented as dynamic driving-related stimuli and digital numeric display panels included as near visual stimuli (simulating speedometer and radio). Eye and head movements were recorded using the faceLAB™ system and the accuracy of target identification was also recorded. Results: The magnitude of eye movements while viewing the driving-related traffic scenes was greater when wearing BIF and PALs than MV and MTF CL (p≤0.013). The magnitude of head movements was greater when wearing SV, BIF and PALs than MV and MTF CL (p<0.0001) and the number of saccades was significantly higher for BIF and PALs than MV (p≤0.043). Target recognition accuracy was poorer for all vision corrections when the near stimulus was located at eccentricities inferiorly and to the left, rather than directly below the primary position of gaze (p=0.008), and PALs gave better performance than MTF CL (p=0.043). Conclusions: Different presbyopic vision corrections alter eye and head movement patterns. In particular, the larger magnitude of eye and head movements and greater number of saccades associated with the spectacle presbyopic corrections, may impact on driving performance.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Aims. To explore differences in self-care behaviour according to demographic and illness characteristics; and relationships among self-care behaviour and demographic and illness characteristics, efficacy expectations and outcome expectations of people with type 2 diabetes in Taiwan. Background. Most people with diabetes do not control their disease appropriately in Taiwan. Enhanced self-efficacy towards managing diseases can be an effective way of improving disease control as proposed by the self-efficacy model which provides a useful framework for understanding adherence to self-care behaviours. Design and methods. The sample comprised 145 patients with type 2 diabetes aged 30 years or more from diabetes outpatient clinics in Taipei. Data were collected using a self-administered questionnaire for this study. One-way anova, t-tests, Pearson product moment correlation and hierarchical regression were analysed for the study. Results. Significant differences were found: between self-care behaviour and complications (t = −2·52, p < 0·01) and patient education (t = −1·96, p < 0·05). Self-care behaviour was significantly and positively correlated with duration of diabetes (r = 0·36, p < 0·01), efficacy expectations (r = 0·54, p < 0·01) and outcome expectations (r = 0·44, p < 0·01). A total of 39·1% of variance in self-care behaviour can be explained by duration of diabetes, efficacy expectations and outcome expectations. Conclusions. Findings support the use of the self-efficacy model as a framework for understanding adherence to self-care behaviour. Relevance to clinical practice. Using self-efficacy theory when designing patient education interventions for people with type 2 diabetes will enhance self-management routines and assist in reducing major complications in the future.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

As a special type of novel flexible structures, tensegrity holds promise for many potential applications in such fields as materials science, biomechanics, civil and aerospace engineering. Rhombic systems are an important class of tensegrity structures, in which each bar constitutes the longest diagonal of a rhombus of four strings. In this paper, we address the design methods of rhombic structures based on the idea that many tensegrity structures can be constructed by assembling one-bar elementary cells. By analyzing the properties of rhombic cells, we first develop two novel schemes, namely, direct enumeration scheme and cell-substitution scheme. In addition, a facile and efficient method is presented to integrate several rhombic systems into a larger tensegrity structure. To illustrate the applications of these methods, some novel rhombic tensegrity structures are constructed.