979 resultados para 090506 Structural Engineering
Resumo:
The need for reduced intrinsic weight of structures and vehicles in the transportation industry has made aluminium research of interest. Aluminium has properties that are favourable for structural engineering, including good strength-to-weight ratio, corrosion resistance and machinability. It can be easily recycled saving energy used in smelting as compared to steel. Its alloys can have ultimate tensile strength of up to 750 MPa, which is comparable to steel. Aluminium alloys are generally weldable, however welding of high strength alloys like the 7xxx series pose considerable challenges. This paper presents research on the weldability of high strength aluminium alloys, principally the 7xxx series. The weldability with various weld processes including MIG, TIG, and FSW, is discussed in addition to consideration of joint types, weld defects and recommendations for minimizing or preventing weld defects. Experimental research was carried out on 7025-T6 and AW-7020 alloys. Samples were welded, and weld cross sections utilized in weld metallurgy studies. Mechanical tests were carried out including hardness tests and tensile tests. In addition, testing was done for the presence of Al2O3 on exposed aluminium alloy. It was observed that at constant weld heat input using a pulsed MIG system, the welding speed had little or no effect on the weld hardness. However, the grain size increased as the filler wire feed rate, welding current and welding speed increased. High heat input resulted in lower hardness of the weld profile. Weld preheating was detrimental to AW- 7020 welds; however, artificial aging was beneficial. Acceptable welds were attained with pulsed MIG without the removal of the Al2O3 layer prior to welding. The Al2O3 oxide layer was found to have different compositions in different aluminium alloys. These findings contribute useful additional information to the knowledge base of aluminium welding. The application of the findings of this study in welding will help reduce weld cost and improve high strength aluminium structure productivity by removing the need for pre-weld cleaning. Better understanding of aluminium weld metallurgy equips weld engineers with information for better aluminium weld design.
Resumo:
Am Fachgebiet Massivbau (Institut für Konstruktiven Ingenieurbau – IKI) des Fachbereichs Bauingenieurwesen der Universität Kassel wurden Bauteilversuche an zweiaxial auf Druck-Zug belasteten, faserfreien und faserverstärkten Stahlbetonscheiben durchgeführt. Dabei wurden die Auswirkungen der Querzugbeanspruchung und der Rissbildung auf die Druckfestigkeit, auf die Stauchung bei Erreichen der Höchstlast sowie auf die Drucksteifigkeit des stabstahl- und faserbewehrten Betons an insgesamt 56 faserfreien und faserverstärkten Beton- und Stahlbetonscheiben untersucht. Auf der Grundlage der experimentell erhaltenen Ergebnisse wird ein Vorschlag zur Abminderung der Druckfestigkeit des gerissenen faserfreien und faserbewehrten Stahlbetons in Abhängigkeit der aufgebrachten Zugdehnung formuliert. Die Ergebnisse werden den in DIN 1045-1 [D4], Eurocode 2 [E3, E4], CEB-FIP Model Code 1990 [C1] und ACI Standard 318-05 [A1] angegebenen Bemessungsregeln für die Druckstrebenfestigkeit des gerissenen Stahlbetons gegenübergestellt und mit den Untersuchungen anderer Wissenschaftler verglichen. Die bekannten Widersprüche zwischen den Versuchsergebnissen, den vorgeschlagenen Modellen und den Regelwerken aus U.S.A., Kanada und Europa können dabei weitgehend aufgeklärt werden. Für nichtlineare Verfahren der Schnittgrößenermittlung und für Verformungsberechnungen wird ein Materialmodell des gerissenen faserfreien und faserbewehrten Stahlbetons abgeleitet. Hierzu wird die für einaxiale Beanspruchungszustände gültige Spannungs-Dehnungs-Linie nach Bild 22 der DIN 1045-1 auf den Fall der zweiaxialen Druck-Zug-Beanspruchung erweitert.
Resumo:
At the Institute of Structural Engineering of the Faculty of Civil Engineering, Kassel University, series tests of slab-column connection were carried out, subjected to concentrated punching load. The effects of steel fiber content, concrete compressive strength, tension reinforcement ratio, size effect, and yield stress of tension reinforcement were studied by testing a total of six UHPC slabs and one normal strength concrete slab. Based on experimental results; all the tested slabs failed in punching shear as a type of failure, except the UHPC slab without steel fiber which failed due to splitting of concrete cover. The post ultimate load-deformation behavior of UHPC slabs subjected to punching load shows harmonic behavior of three stages; first, drop of load-deflection curve after reaching maximum load, second, resistance of both steel fibers and tension reinforcement, and third, pure tension reinforcement resistance. The first shear crack of UHPC slabs starts to open at a load higher than that of normal strength concrete slabs. Typically, the diameter of the punching cone for UHPC slabs on the tension surface is larger than that of NSC slabs and the location of critical shear crack is far away from the face of the column. The angle of punching cone for NSC slabs is larger than that of UHPC slabs. For UHPC slabs, the critical perimeter is proposed and located at 2.5d from the face of the column. The final shape of the punching cone is completed after the tension reinforcement starts to yield and the column stub starts to penetrate through the slab. A numerical model using Finite Element Analysis (FEA) for UHPC slabs is presented. Also some variables effect on punching shear is demonstrated by a parametric study. A design equation for UHPC slabs under punching load is presented and shown to be applicable for a wide range of parametric variations; in the ranges between 40 mm to 300 mm in slab thickness, 0.1 % to 2.9 % in tension reinforcement ratio, 150 MPa to 250 MPa in compressive strength of concrete and 0.1 % to 2 % steel fiber content. The proposed design equation of UHPC slabs is modified to include HSC and NSC slabs without steel fiber, and it is checked with the test results from earlier researches.
Resumo:
This paper deals with the problem of semiactive vibration control of civil engineering structures subject to unknown external disturbances (for example, earthquakes, winds, etc.). Two kinds of semiactive controllers are proposed based on the backstepping control technique. The experimental setup used is a 6-story test structure equipped with shear-mode semiactive magnetorheological dampers being installed in the Washington University Structural Control and Earthquake Engineering Laboratory (WUSCEEL). The experimental results obtained have verified the effectiveness of the proposed control algorithms
Resumo:
In this paper, we address this problem through the design of a semiactive controller based on the mixed H2/H∞ control theory. The vibrations caused by the seismic motions are mitigated by a semiactive damper installed in the bottom of the structure. It is meant by semiactive damper, a device that absorbs but cannot inject energy into the system. Sufficient conditions for the design of a desired control are given in terms of linear matrix inequalities (LMIs). A controller that guarantees asymptotic stability and a mixed H2/H∞ performance is then developed. An algorithm is proposed to handle the semiactive nature of the actuator. The performance of the controller is experimentally evaluated in a real-time hybrid testing facility that consists of a physical specimen (a small-scale magnetorheological damper) and a numerical model (a large-scale three-story building)
Resumo:
This short paper addresses the problem of designing a QFT (quantitative feedback theory) based controllers for the vibration reduction in a 6-story building structure equipped with shear-mode magnetorheological dampers. A new methodology is proposed for characterizing the nonlinear hysteretic behavior of the MR damper through the uncertainty template in the Nichols chart. The design procedure for QFT control design is briefly presented
Resumo:
Through this research is detailed the Brazilian seismic code focused on concrete projects design related to seismic engineering. At the beginning of the research is debated the fundaments of the seismic effects, the influence factors to the development of seismic effects and also relates the main data registration happened in Brazil. The second step is study the Brazilian seismic code explaining all the concepts related to it and does a compilation to the most important international seismic code. At this research is developed the designing of a building submitted to horizontal equivalent seismic forces and the modal process based on the answer spectrum based on the brazilin seismic code. It was also developed the design of a commercial building submitted to seismic loads based on the Brazilian code answer spectrum and compared to the same building submitted to wind loads.The research also focus on projects conception and detailing of seismic engineering Project design. At the study of seismic engineering it was concluded that seismic effects require special focus on concrete structures design, proving that is the essential consider the seismic effects
Resumo:
Residual stresses play an important role in the fatigue lives of structural engineering components. In the case of near surface tensile residual stresses, the initiation and propagation phases of fatigue process are accelerated; on the other hand, compressive residual stresses close to the surface may increase fatigue life. In both decorative and functional applications, chromium electroplating results in excellent wear and corrosion resistance. However, it is well known that it reduces the fatigue strength of a component. This is due to high tensile internal stresses and microcrack density. Efforts to improve hard chromium properties have increased in recent years. In this study, the effect of a nickel layer sulphamate process, as simple layer and interlayer, on fatigue strength of hard chromium electroplated AISI 4340 steel hardness - HRc 53, was analysed. The analysis was performed by rotating bending fatigue tests on AISI 4340 steel specimens with the following experimental groups: base material, hard chromium electroplated, sulphamate nickel electroplated, sulphamate nickel interlayer on hard chromium electroplated and electroless nickel interlayer on hard chromium electroplated. Results showed a decrease in fatigue strength in coated specimens and that both nickel plating interlayers were responsible for the increase in fatigue life of AISI 4340 chromium electroplated steel. The shot peening pre-treatment was efficient in reducing fatigue loss in the alternatives studied.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Pós-graduação em Engenharia Civil - FEIS
Resumo:
Pós-graduação em Engenharia Civil - FEIS