933 resultados para Ângulo do contato


Relevância:

60.00% 60.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Pós-graduação em Engenharia Mecânica - FEG

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The present work aimed to evaluate the volumetric distribution profiles, droplet spectra, surface tension, contact angle of droplet and the spraying liquid deposition over the peanut leaves (Arachis hypogaea L.), under artificial rain, in comparison with deposition without rain, using two hydraulic nozzle models of plain fan and insecticide spraying liquids with and without adjuvants addition. It were used a patternator for volumetric distribution analysis, a laser particles analyzer to evaluate droplet spectra produced by SF 110015 and XR 110015 nozzles and tensiometer for droplet tension and contact angle. The spraying liquids evaluated were: water, lambda-cialotrina, lambda-cialotrina + nitrogen fertilizer and lambda-cialotrina + mineral oil. All experiments followed a completely randomized design. Data were submitted to variance analysis by F test and the means comparisons by Scott-Knott test at 5% of probability. According to the results, it must be considered the maximum spacing in spray boom usage of 50 and 90 cm between the nozzles SF110015 and XR110015, respectively. The adjuvants effects on droplet spectra have shown addicted to the nozzle and the product used, and the adjuvants addition to the spraying liquid affected the potential risk of drift; The Volumetric Median Diameter (VMD) of produced droplets by nozzles filled into thin class and were not influenced by the adjuvants. The nitrogen fertilizer adjuvant may be indicated to promote improvements on coverage and droplet deposition on target.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

A adesão longitudinal continua a representar um dos maiores desafios da Odontologia moderna. Uma nova proposta para o estabelecimento do equilíbrio da adesão aos tecidos dentários surge, baseada na observação dos resultados obtidos com a tecnologia Grander para revitalização da água. Objetiva-se com o estudo verificar a influência dessa tecnologia nas propriedades físicas de dois sistemas adesivos (convencional e autocondicionante) à partir da medição da tensão superficial e do ângulo de contato; e avaliar a formação e a qualidade da camada híbrida em dentina humana e bovina. A tensão superficial de quatro diferentes líquidos (água, Single Bond- 3M, Primer do Clearfil SE Bond -Kuraray, e Bond do Clearfil SE-Kuraray), foi medida antes e após a modificação pelo procedimento Grander em aparelho goniômetro (Ramé-hart). O ângulo de contato com três substratos distintos (placa de titânio, dentina humana e dentina bovina), foi medido para os quatro líquidos também antes e após a modificação pelo procedimento Grander, também em goniômetro. A formação e qualidade da camada híbrida, foi avaliada em MEV, a partir da confecção de corpos de prova dos substratos humano e bovino, devidamente embutidos, preparados em lixas de variada granulação até a exposição de dentina, submetidos ao procedimento adesivo (SB ou CSEB) normal ou grander modificado, recebendo ao final dupla camada de resina composta Z250-3M, fotopolimerizada por 40s. Após armazenamento em estufa bacteriológica por 24h, os procedimentos para análise ao MEV foram realizados (fixação, desidratação, secagem e metalização). A estatística de Análise de Variância ANOVA e Teste de Tukey 5% revelou que: houve redução estatisticamente significante da tensão superficial para todos os líquidos Grander modificados; houve redução estatisticamente... (Resumo completo, clicar acesso eletrônico abaixo)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Thin polymeric films deposited by plasma are very atractive for many industrial and scientific applications, in areas such as electronics, mechanics, coatings, biomaterials, among others, due to its favorable properties such as good adhesion to the substrate, high crosslinking, nanomectric thickness, homogeneity, etc. In this work, thin films were deposited by plasma immersion ion implantation and deposition technique from a hexamethyldisilazane/argon mixture at different proportions. These films were subjected to several characterizations, such as, contact angle, which presented values near to 100 degrees, surface energy, with values near to 31 mJ/m2, hardness with values between 0.7 and 2.6 GPa, thickness from 100 to 200 nm, refractive index from 1.56 to 1.64, molecular structure presenting the following functional groups in the infrared spectra region: CHx from 2960 to 2900 cm-1; Si-H around 2130 cm-1; CH3 in Si-(CH3)x around 1410 cm-1; CH3 in Si-(CH3)x in 1260 cm-1; N-H around 1180 cm-1; CH2 in Si-CH2-Si bonds around 1025 cm-1; Si-O in Si-O-Si from 1020 to 1100 cm-1; Si-N in Si-H-Si bonds around 940 cm-1; CH3 in Si-(CH3)3 in 850 cm-1; Si-C bonds in Si-(CH3)2 around 800 cm-1; and Si-H in 680 cm-1 . From these characterizations, it was possible to conclude that the concentration of argon or hexamethyldisilazane in the mixture changed the resulting polymer

Relevância:

60.00% 60.00%

Publicador:

Resumo:

In this work, air dielectric barrier discharge (DBD) operating at two different frequencies (60 Hz and 17 kHz) was used to improve surface properties of polypropylene (PP). The changes in surface hydrophilicity were investigated by contact angle measurements. The modifications in chemical composition of PP surface were studied by X-ray photoelectron spectroscopy (XPS) and Fourier-transformed infrared spectroscopy (FTIR). The PP roughness were analyzed before and after the DBD treatment using atomic force microscopy (AFM). In order to compare the results obtained at different frequencies, the analyses are presented as a function of the deposited energy density. The results show that both DBD treatments led to formation of low-molecular weight oxidized material (LMWOM). It tends to agglomerate into small mounts on the surface, as shown by AFM analyses. These structures are weakly bounded to the surface and can be easily removed by rinsing in polar solvents. After washing the DBD-treated samples, the PP partially recovers its original wetting characteristics. This suggests that oxidation also occurred at deeper and more permanent levels on the PP samples. Comparing both DBD treatments, the 17 kHz process was found to be more efficient in introducing oxygen groups to the PP surface

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Supermarket plastic bags are produced by high density polyethylene (HDPE) and low density polyethylene (LDPE) resins. In Brazil, are produced annually around 150 plastic bags per capita. Disposed in landfills, the supermarket plastic bags prevent the passage of water by slowing the breakdown of biodegradable materials and hindering compaction of waste, according to their low degradability. This work investigated the biodegradation of PE bags containing additive oxo-biodegradable and bags without additives: buried in soil columns, exposed in a controlled environment and exposed to air. The analysis methods used to assess the changes brought in the bags with respect to microbial action and exposure time were weight loss, thickness measurement, infrared (FTIR), scanning electron microscopy (SEM) and contact angle. The results showed that the use of prodegradant agents such as oxobiodegradable additives in polyethylene bags, buried in soil for 270 days, was not efficient to accelerate the biodegradation by microorganisms. It seems that these additives have been more efficient to degrade the colored pigmentation of printed bags, under the influence of light and heat.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

A grande quantidade de resíduos plásticos sintéticos descartada diariamente no meio ambiente tem preocupado governantes do mundo todo. No sentido de minimizar este problema várias soluções estão sendo propostas. Uma delas é a busca de materiais potencialmente biodegradáveis no solo. Neste trabalho desenvolveu-se blendas de poli(3-hidroxibutirato) PHB, um polímero biodegradável, com polietileno de baixa densidade PEBD, um polímero convencional e avaliou-se os efeitos do termotratamento em estufa e do fototratamento em câmara de envelhecimento acelerado sobre a biodegradação destes filmes em coluna de solo. As blendas de PEBD/PHB foram preparadas em composições de 90/10, 80/20 e 70/30, utilizando prensa sob aquecimento e os filmes foram analisados por Espectroscopia de Absorção no Infravermelho (FTIR), Microscopia de Luz Polarizada (MLP), perda de massa e ângulo de contato.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The objective of the present work was to evaluate surface of experimental alloy Ti-7.5Mo after hydrothermal treatment. Ingots were obtained in arc melting furnace under an argon atmosphere and then homogenized under vacuum at 1100ºC for 86.4 ks to eliminate chemical segregation and after cold worked discs were cutting and grinding. For surface treatment, samples were immersed in a container with NaOH aqueous solution 5M, autoclaved, washed with distilled water. Followed, samples were heat treated and they were soaking in 5xSBF to form an apatite layer on the surface. Surfaces were investigated by, scanning electron microscopy, X-Rays powder diffraction, atomic force microscopy and contact angle, in order to evaluate the wettability of the alloy surface. The results were compared with our previous studies using the group of chemical surface treatments and results shows better condition is 120 minutes in the autoclave

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Pós-graduação em Engenharia Mecânica - FEG

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Titanium has proven its suitability as an implant material in surgery over many years. Excellent biocompatibility and corrosion resistance are outstanding features. Implant surfaces always causes concern and interest in scientific communities, due to its close relationship with the time required for osseointegration. Surface modification can be performed by several methods, being laser irradiation one of them. Titanium implants with two different surfaces were inserted in rabbits: Group I (G-I: machined surface, control group), and group II (G-II: laser irradiated, test group) being processed 30 and 60 days after surgery for histological analysis. Surface characterization was performed with SEM-EDS, contact angle measurement, and mean roughness (Ra) parameters. Surface analysis in the GII group showed a nanomorphology affected by melt and quick solidification zones following laser irradiation (SEM), as well as total wettability and Ra mean values significantly higher than in the G-I group. The laser treatment resulted in a homogenized, porous surface, with increased surface area and volume. Histological analysis of bone-implant contact linear extension (BIC) showed better results in G-II at 30 days (39.26 ± 18.23 and 68.41 ± 13.68 for G-I and G-II groups, respectively). Titanium implants modified by laser irradiation showed important features that may accelerate early osseointegration.