974 resultados para (H2S HS- S2-)


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Herein, we demonstrate that highly sensitive conductometric gas nanosensors for H(2)S can be synthesized by electrodepositing gold nanoparticles on single-walled carbon nanotube (SWNT) networks. Adjusting the electrodeposition conditions allowed for tuning of the size and number of gold nanoparticles deposited. The best H(2)S sensing performance was obtained with discrete gold nanodeposits rather than continuous nanowires. The gas nanosensors could sense H(2)S in air at room temperature with a 3 ppb limit of detection. The sensors were reversible, and increasing the bias voltage reduced the sensor recovery time, probably by local Joule heating. The sensing mechanism is believed to be based on the modulation of the conduction path across the nanotubes emanating from the modulation of electron exchange between the gold and carbon nanotube defect sites when exposed to H(2)S.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Extensive departures from balanced gene dose in aneuploids are highly deleterious. However, we know very little about the relationship between gene copy number and expression in aneuploid cells. We determined copy number and transcript abundance (expression) genome-wide in Drosophila S2 cells by DNA-Seq and RNA-Seq. We found that S2 cells are aneuploid for >43 Mb of the genome, primarily in the range of one to five copies, and show a male genotype ( approximately two X chromosomes and four sets of autosomes, or 2X;4A). Both X chromosomes and autosomes showed expression dosage compensation. X chromosome expression was elevated in a fixed-fold manner regardless of actual gene dose. In engineering terms, the system "anticipates" the perturbation caused by X dose, rather than responding to an error caused by the perturbation. This feed-forward regulation resulted in precise dosage compensation only when X dose was half of the autosome dose. Insufficient compensation occurred at lower X chromosome dose and excessive expression occurred at higher doses. RNAi knockdown of the Male Specific Lethal complex abolished feed-forward regulation. Both autosome and X chromosome genes show Male Specific Lethal-independent compensation that fits a first order dose-response curve. Our data indicate that expression dosage compensation dampens the effect of altered DNA copy number genome-wide. For the X chromosome, compensation includes fixed and dose-dependent components.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Density-functional theory has been used to investigate the chemisorption of S, SH, and H2S as well as the coadsorption of S and H and SH and H on Pt(111). In addition reaction pathways and energy profiles for the conversion of adsorbed S and H into gas-phase H2S have been determined. It has been found that S, SH, and H2S bind preferentially at face-centered-cubic (fcc), bridge, and top sites, respectively. Both the S+H and SH+H reactions have high barriers (similar to1 eV) and high exothermicities (similar to1 eV). This reveals that adsorbed H2S and SH are highly unstable adsorbates on Pt(111) and that adsorbed S (and H) is the most stable SHX (X=0,1,2) intermediate on Pt(111) (C) 2001 American Institute of Physics.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Electrochemical oxidation of hydrogen sulfide gas (H2S) has been studied at a platinum microelectrode (10 mu m diameter) in five room temperature ionic liquids (RTILs): [C(4)mim][OTf], [C(4)dmim][NTf2], [C(4)mim][PF6],. [C(6)mim][FAP], and [P-14,P-6,P-6,P-6][FAP] (where [C-n mim](+) = 1-alkyl-3-methylimidazolium, [C(n)dmim](+) = 1-alkyl-2,3-dimethylimidazolium, [P-14,P-6,P-6,P-6](+) = tris(p-hexyl)-tetradecylphosphonium, [OTf](-) = trifluoromethlysulfonate, [NTf2](-) = bis(trifluoromethylsulfonyl)imide, [PF6](-) = hexafluorophosphate, and [FAP](-) = trifluorotris(pentafluoroethyl)phosphate). In four of the RTILs ([C(4)dmim][NTf2], [C(4)mim][PF6], [C(6)mim][FAP], and [P-14,P-6,P-6,P-6][FAP]), no clear oxidative signal was observed. In [C(4)mim][OTf], a chemically irreversible oxidation peak was observed on the oxidative sweep with no signal seen on the reverse scan. The oxidative signal showed an adsorptive stripping peak type followed by near steady-state limiting current behavior. Potential step chronoamperometry was carried out on the reductive wave, giving a diffusion coefficient and solubility of 1.6 x 10(-11) m(2) s(-1) and 7 mM, respectively (at 25 degrees C). Using these data, we modeled the oxidation signal kinetically, assuming adsorption preceded oxidation and that adsorption was approximately Langmuirian. The oxidation step was described by an electrochemically fully irreversible Tafel law/Butler-Volmer formalism. Modeling indicated a substantial buildup of H2S in the double layer in excess of the coverage that would be expected for a monolayer of chemisorbed H2S, reflecting high solubility of the gas in [C(4)mim][OTf] and possible attractive interactions with the [OTf](-) anions accumulated at the electrode at potentials positive of the potential of zero charge. Solute enrichment of the double layer in the solution adjacent to the electrode appears a novel feature of RTIL electrochemistry.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We have searched for HDS emission in a small number of hot cores. Using observations of (H2S)-S-34, we have derived upper limits to the [HDS]/[H2S] abundance ratio. The upper limits, which are close to 10(-3) can be interpreted in two ways, depending on whether grain surface reactions contribute to the formation of H2S. If grains do not dominate, then the H2S observed is formed in hot, post-shocked gas and a ratio close to the cosmic [D]/[H] ratio is expected for [HDS]/[H2S]. This scenario is consistent with our upper limits and with the relatively low abundance ratio found for [HDO]/[H2O] in hot cores but does not seem to account for all of the molecular [D]/[H] ratios observed in hot cores. If grains do dominate the formation of HBS, then the observed upper limit to the ratio is consistent with the formation of 'hot core ices' at a temperature of 60-80 K, close to the temperature at which cometary ices are thought to form.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Trihalomethanes (THMs) are widely referred and studied as disinfection by-products (DBPs). The THMs that are most commonly detected are chloroform (TCM), bromodichloromethane (BDCM), chlorodibromomethane (CDBM), and bromoform (TBM). Several studies regarding the determination of THMs in swimming pool water and air samples have been published. This paper reviews the most recent work in this field, with a special focus on water and air sampling, sample preparation and analytical determination methods. An experimental study has been developed in order to optimize the headspace solid-phasemicroextraction (HS-SPME) conditions of TCM, BDCM, CDBM and TBM from water samples using a 23 factorial design. An extraction temperature of 45 C, for 25min, and a desorption time of 5 min were found to be the best conditions. Analysis was performed by gas chromatography with an electron capture detector (GC-ECD). The method was successfully applied to a set of 27 swimming pool water samples collected in the Oporto area (Portugal). TCM was the only THM detected with levels between 4.5 and 406.5 g L1. Four of the samples exceeded the guideline value for total THMs in swimming pool water (100 gL1) indicated by the Portuguese Health Authority.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Drug abuse is a widespread problem affecting both teenagers and adults. Nitrous oxide is becoming increasingly popular as an inhalation drug, causing harmful neurological and hematological effects. Some gas chromatography-mass spectrometry (GC-MS) methods for nitrous oxide measurement have been previously described. The main drawbacks of these methods include a lack of sensitivity for forensic applications; including an inability to quantitatively determine the concentration of gas present. The following study provides a validated method using HS-GC-MS which incorporates hydrogen sulfide as a suitable internal standard allowing the quantification of nitrous oxide. Upon analysis, sample and internal standard have similar retention times and are eluted quickly from the molecular sieve 5Å PLOT capillary column and the Porabond Q column therefore providing rapid data collection whilst preserving well defined peaks. After validation, the method has been applied to a real case of N2O intoxication indicating concentrations in a mono-intoxication.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

One of the main challenges in the development of metal-oxide gas sensors is enhancement of selectivity to a particular gas. Currently, two general approaches exist for enhancing the selective properties of sensors. The first one is aimed at preparing a material that is specifically sensitive to one compound and has low or zero cross-sensitivity to other compounds that may be present in the working atmosphere. To do this, the optimal temperature, doping elements, and their concentrations are investigated. Nonetheless, it is usually very difficult to achieve an absolutely selective metal oxide gas sensor in practice. Another approach is based on the preparation of materials for discrimination between several analyte in a mixture. It is impossible to do this by using one sensor signal. Therefore, it is usually done either by modulation of sensor temperature or by using sensor arrays. The present work focus on the characterization of n-type semiconducting metal oxides like Tungsten oxide (WO3), Zinc Oxide (ZnO) and Indium oxide (In2O3) for the gas sensing purpose. For the purpose of gas sensing thick as well as thin films were fabricated. Two different gases, NO2 and H2S gases were selected in order to study the gas sensing behaviour of these metal oxides. To study the problem associated with selectivity the metal oxides were doped with metals and the gas sensing characteristics were investigated. The present thesis is entitled Development of semiconductor metal oxide gas sensors for the detection of NO2 and H2S gases and consists of six chapters.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador: