973 resultados para (Drop-) stones


Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents an experimental study of the effects of tow-drop gaps in Variable Stiffness Panels under drop-weight impact events. Two different configurations, with and without ply-staggering, have been manufactured by Automated Fibre Placement and compared with their baseline counterpart without defects. For the study of damage resistance, three levels of low velocity impact energy are generated with a drop-weight tower. The damage area is analysed by means of ultrasonic inspection. Results of the analysed defect configurations indicate that the influence of gap defects is only relevant under small impact energy values. However, in the case of damage tolerance, the residual compressive strength after impact does not present significant differences to that of conventional straight fibre laminates. This indicates that the strength reduction is driven mainly by the damage caused by the impact event rather than by the influence of manufacturing-induced defects

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aims: This study was carried out to investigate the role of common liver function tests, and the degree of common bile duct dilatation in the differential diagnosis of extrahepatic cholestasis, as well as the occurrence, diagnosis and treatment of iatrogenic bile duct injuries. In bile duct injuries, special attention was paid to gender and severity distribution and long-term results. Patients and methods: All consecutive patients with diagnosed common bile duct stones or malignant strictures in ERCP between August 2000 and November 2003. Common liver function tests were measured in the morning before ERCP on all of these 212 patients, and their common bile duct diameter was measured from ERCP films. Between January 1995 and April 2002, 3736 laparoscopic cholecystectomies were performed and a total of 32 bile duct injuries were diagnosed. All pre-, per-, and postoperative data were collected retrospectively; and the patients were also interviewed by phone. Results: Plasma bilirubin proved to be the best discriminator between CBD stones and malignant strictures (p≤0.001 compared to other liver function tests and degree of common bile duct dilatation). The same effect was seen in Receiver Operating Characteristics curves (AUC 0.867). With a plasma bilirubin cut-off value of 145 μmol/l, four out of five patients could be classified correctly. The degree of common bile duct dilatation proved to be worthless in differential diagnostics. After laparoscopic cholecystectomy the total risk for bile duct injury was 0.86%, including cystic duct leaks. 86% of severe injuries and 88% of injuries requiring operative treatment were diagnosed in females. All the cystic duct leakages and 87% of the strictures were treated endoscopically. Good long-term results were seen in 84% of the whole study population. Conclusions: Plasma bilirubin is the most effective liver function test in differential diagnosis between CBD stones and malignant strictures. The only value of common bile duct dilatation is its ability to verify the presence of extrahepatic cholestasis. Female gender was associated with higher number of iatrogenic bile duct injuries, and in particular, most of the major complications occur in females. Most of the cystic duct leaks and common bile duct strictures can be treated endoscopically. The long-term results in our institution are at an internationally acceptable level.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A mathematical model of the voltage drop which arises in on-chip power distribution networks is used to compare the maximum voltage drop in the case of different geometric arrangements of the pads supplying power to the chip. These include the square or Manhattan power pad arrangement, which currently predominates, as well as equilateral triangular and hexagonal arrangements. In agreement with the findings in the literature and with physical and SPICE models, the equilateral triangular power pad arrangement is found to minimize the maximum voltage drop. This headline finding is a consequence of relatively simple formulas for the voltage drop, with explicit error bounds, which are established using complex analysis techniques, and elliptic functions in particular.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A dispersive liquid-liquid microextraction based on solidification of floating organic drop for simultaneous extraction of trace amounts of nickel, cobalt and copper followed by their determination with electrothermal atomic absorption spectrometry was developed. 300 µL of acetone and 1-undecanol was injected into an aqueous sample containing diethyldithiocarbamate complexes of metal ions. For a sample volume of 10 mL, enrichment factors of 277, 270 and 300 and detection limits of 1.2, 1.1 and 1 ng L-1 for nickel, cobalt and copper were obtained, respectively. The method was applied to the extraction and determination of these metals in different water samples.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this study, dispersive liquid-liquid microextraction based on the solidification of floating organic droplets was used for the preconcentration and determination of thorium in the water samples. In this method, acetone and 1-undecanol were used as disperser and extraction solvents, respectively, and the ligand 1-(2-thenoyl)-3,3,3-trifluoracetone reagent (TTA) and Aliquat 336 was used as a chelating agent and an ion-paring reagent, for the extraction of thorium, respectively. Inductively coupled plasma-optical emission spectrometry was applied for the quantitation of the analyte after preconcentration. The effect of various factors, such as the extraction and disperser solvent, sample pH, concentration of TTA and concentration of aliquat336 were investigated. Under the optimum conditions, the calibration graph was linear within the thorium content range of 1.0-250 µg L-1 with a detection limit of 0.2 µg L-1. The method was also successfully applied for the determination of thorium in the different water samples.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Acid mine drainage (AMD) presents a serious problem for the environment for the massive formation of acidic leachates containing heavy metals. The present work deals with the AMD treatment using neutralizing limestone side-products. The conventional methods for prevention, mitigating and control of AMD formation are described. The experimental testing of Nordkalk Oy calcite-containing side-stones for acid neutralizing and removal of nickel from solutions presents the research objective. The batch experiments in acid neutralizing with subsequent metal content analysis were carried out. The results showed the dependence of pH on the dose of neutralizing material and the exposure time. The nickel removal, unlike iron, within the pH range from 1.2 to 6.0 appeared to be inadequate. The further research on nickel co-precipitation with iron and aluminium may appear to be necessary together with testing of alkalinity strengthening materials.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The objective of the present work is the experimental determination of pressure drop coefficients (loss coefficients) for elliptic and circular sections in one, two and three-row arrangements of plate fin and tube heat exchangers. The experiments permitted to correlate the dimensionless loss coefficient with the flow Reynolds number in the rectangular channel formed by the plate fins. The experimental technique consisted of the measurement of the longitudinal pressure distribution along the flow channel, for several values of air mass flow rate. The total number of data runs, each one characterized by the flow Reynolds number, was 216. The present geometry is used in compact heat exchangers for air conditioning systems, heaters, radiators, and others. Also, it is verified the influence of the utilization of elliptic tubes, instead of circular ones, in the pressure drop. The measurements were performed for Reynolds numbers ranging from 200 to 1900.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Experiments were performed to determine average heat transfer coefficients and friction factors for turbulent flow through annular ducts with pin fins. The measurements were carried out by means of a double-pipe heat exchanger. The total number of pins attached to the inner wall of the annular region was 560. The working fluids were air, flowing in the annular channel, and water through the inner circular tube. The average heat transfer coefficients of the pinned air-side were obtained from the experimental determination of the overall heat transfer coefficients of the heat exchanger and from the knowledge of the average heat transfer coefficients of the circular pipe (water-side), which could be found in the pertinent literature. To attain fully developed conditions, the heat exchanger was built with additional lengths before and after the test section. The inner circular duct of the heat exchanger and the pin fins were made of brass. Due to the high thermal conductivity of the brass, the small tube thickness and water temperature variation, the surface of the internal tube was practically isothermal. The external tube was made of an industrial plastic which was insulated from the environment by means of a glass wool batt. In this manner, the outer surface of the annular channel can be considered adiabatic. The results are presented in dimensionless forms, in terms of average Nusselt numbers and friction factors as functions of the flow Reynolds number, ranging from 13,000 to 80,000. The pin fin efficiency, which depends on the heat transfer coefficient, is also determined as a function of dimensionless parameters. A comparison of the present results with those for smooth sections (without pins) is also presented. The purpose of such a comparison is to study the influence of the presence of the pins on the pressure drop and heat transfer rate.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fuel elements of PWR type nuclear reactors consist of rod bundles, arranged in a square array, and held by spacer grids. The coolant flows, mainly, axially along the rods. Although such elements are laterally open, experiments are performed in closed type test sections, originating the appearance of subchannels with different geometries. In the present work, utilizing a test section of two bundles of 4x4 pins each, experiments were performed to determine the friction and the grid drag coefficients for the different subchannels and to observe the effect of the grids in the crossflow, in cases of inlet flow maldistribution.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Venturi scrubbers are high efficiency gas cleaners in which suspended particles are removed from gas streams by droplets formed by liquid atomisation, usually in the venturi throat. The size of the droplets formed is of fundamental importance to the performance of the equipment, both in terms of pressure drop and collection efficiency. In this study, drop sizes in a cylindrical laboratory scale venturi scrubber were measured using a laser diffraction technique. Gas velocity and liquid to gas ratios varied from 50 to 90 m/s and 0.5 to 2.0 l/m3, respectively. Water was inserted as perpendicular jets at the beginning of the throat. Measurements were performed at three positions: two located along the throat, and the last one at the end of the diffuser. The data presented here are a typical example of pneumatic atomisation and can be relevant to other industrial applications such as combustion and engine technology. Finally, results are compared to available correlations and the validity of these equations is discussed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An experimental apparatus for the study of core annular flows of heavy oil and water at room temperature has been set up and tested at laboratory scale. The test section consists of a 2.75 cm ID galvanized steel pipe. Tap water and a heavy oil (17.6 Pa.s; 963 kg/m³) were used. Pressure drop in a vertical upward test section was accurately measured for oil flow rates in the range 0.297 - 1.045 l/s and water flow rates ranging from 0.063 to 0.315 l/s. The oil-water input ratio was in the range 1-14. The measured pressure drop comprises gravitational and frictional parts. The gravitational pressure drop was expressed in terms of the volumetric fraction of the core, which was determined from a correlation developed by Bannwart (1998b). The existence of an optimum water-oil input ratio for each oil flow rate was observed in the range 0.07 - 0.5. The frictional pressure drop was modeled to account for both hydrodynamic and net buoyancy effects on the core. The model was adjusted to fit our data and shows excellent agreement with data from another source (Bai, 1995).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Nephrolithiasis is one of the most common diseases in the Western world. The disease manifests itself with intensive pain, sporadic infections, and, sometimes, renal failure. The symptoms are due to the appearance of urinary stones (calculi) which are formed mainly by calcium salts. These calcium salts precipitate in the renal papillae and/or within the collecting ducts. Inherited forms of nephrolithiasis related to chromosome X (X-linked hypercalciuric nephrolithiasis or XLN) have been recently described. Hypercalciuria, nephrocalcinosis, and male predominance are the major characteristics of these diseases. The gene responsible for the XLN forms of kidney stones was cloned and characterized as a chloride channel called ClC-5. The ClC-5 chloride channel belongs to a superfamily of voltage-gated chloride channels, whose physiological roles are not completely understood. The objective of the present review is to identify recent advances in the molecular pathology of nephrolithiasis, with emphasis on XLN. We also try to establish a link between a chloride channel like ClC-5, hypercalciuria, failure in urine acidification and protein endocytosis, which could explain the symptoms exhibited by XLN patients.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study aimed to compare the totally tubeless percutaneous nephrolithotomy and standard percutaneous nephrolithotomy techniques regarding their rates of success and complications in patients with kidney stones. Patients were randomly assigned to two groups. Forty-four patients (24 men; mean age: 50.40±2.02 years) received totally tubeless percutaneous nephrolithotomy (PCNL; no nephrostomy catheter or ureteral catheter after PCNL) and 40 patients (18 men; mean age: 49.95±13.38 years) underwent standard PCNL (a nephrostomy catheter and ureteral catheter were used after PCNL). All surgeries were performed by one surgeon. Postoperative changes in hemoglobin, the blood transfusion rate, changes in creatinine levels, operation time, analgesic need, hospitalization time, and complication rate were compared between the groups. No significant differences were observed in age, gender, stone size, and surgery side between the groups (P<0.05). The operation time was significantly lower in the totally tubeless PCNL group than in the standard PCNL group (P=0.005). Pethidine requirements were significantly higher in the standard PCNL group than the totally tubeless PCNL group (P=0.007). Hospitalization time was significantly higher in the standard PCNL group than in the totally tubeless PCNL group (P<0.0001). The complication rate was 15% in the standard PCNL group and 9.1% in the totally tubeless PCNL group (P=0.73). The totally tubeless PCNL technique is safe and effective, even for patients with staghorn stones. This technique is associated with decreased pain, analgesic needs, and operative and hospitalization time. We believe that a normal peristaltic ureter is the best drainage tube.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study analyzes a young Finnish micro-sized firm that is attempting to reach internationalization readiness in the pre-internationalization stage. The purpose of this research is to analyze and better understand how a young firm reaches internationalization readiness in the pre-internationalization stage. Small firm internationalization is a vastly researched topic. Little emphasis has been placed on the specific antecedents that help the firm reach internationalization readiness in the pre-internationalization stage. The contribution of this research is thus two-fold. First, the research contributes to known theories of firm internationalization. Second, the research further extends knowledge related to how firms reach internationalization readiness specifically in the pre-internationalization stage. The theoretical background of the research involves the traditional stage theory (Uppsala model), pre-internationalization stage theory, international entrepreneurship theory and dynamic capabilities theory. With the help of these four relevant theories, empirical data was collected. The research method utilized in this study was a qualitative single case study combined with critical realist philosophy. The data analysis of this research was conducted using abduction in order to allow freedom in the analysis of the research findings. The empirical data was collected through semi-structured, face-to-face interviews. The key respondents in this study were the two managers of the case company. The findings of this study revealed four important themes from the case company’s perspective towards reaching internationalization readiness in the pre-internationalization stage. Extensive knowledge of the home market and target market were the two most important themes in this research. The next most relevant theme for reaching internationalization readiness in the pre-internationalization stage was the managers’ previous international business experiences. The final theme affecting the firm’s ability to reach internationalization readiness was the firm’s specific resources. Even though the research findings of this study are case sensitive, the research insights and explanations have the potential to be transferred to similar firms and contexts. Future research should therefore aim towards more longitudinal studies in which the context is emphasized. This should include a variety of firms in similar stages of internationalization and contexts. Future studies of this kind would be of great benefit to academia.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Educators continually look for strategies to enhance and improve the reading practices of their students. This is an especially challenging task for secondary level teachers as high school students often lack intrinsic motivation to read for pleasure (Bucher & Manning, 2004; Horton, 2005; Wooicott, Research Pty. Ltd. 2001). The purpose of this study was to detennine the effects of the Drop Everything and Read (D.E.A.R.) program on writing, on reading, and on grades, from the perspective of eight Grade 9 students. Of particular interest were the students' perceptions of the effect that participation in the program had on their grades, their writing, their motivation to reading, and their concept of themselves as readers. The eight participants were tracked over the course of a semester. Using qualitative research techniques, data were collected from four sources: two student surveys, researcher's daily field observations, students' weekly reading logs, and three open-ended one-on-one interviews. In order to gain an understanding of the impact of the D.E.A.R program, the data were corroborated, and analyzed with NVivo: N7 (2006). From the data analysis, five themes emerged as a function of the Grade 9 students' experiences in the D.E.A.R. program: Reading Preferences, Time Spent Reading, Making Associations with Reading for Pleasure, Perceptions of Self-as-Reader, and Evaluations of the D.E.A.R Program. In the interest of supporting students' positive reading habits and for the future implementation, these five themes are presented as a series of findings together with recommendations for practice.