996 resultados para total hemocyte count


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Total disc replacement (TDR) clinical success has been reported to be related to the residual motion of the operated level. Thus, accurate measurement of TDR range of motion (ROM) is of utmost importance. One commonly used tool in measuring ROM is the Oxford Cobbometer. Little is known however on its accuracy (precision and bias) in measuring TDR angles. The aim of this study was to assess the ability of the Cobbometer to accurately measure radiographic TDR angles. An anatomically accurate synthetic L4-L5 motion segment was instrumented with a CHARITE artificial disc. The TDR angle and anatomical position between L4 and L5 was fixed to prohibit motion while the motion segment was radiographically imaged in various degrees of rotation and elevation, representing a sample of possible patient placement positions. An experienced observer made ten readings of the TDR angle using the Cobbometer at each different position. The Cobbometer readings were analyzed to determine measurement accuracy at each position. Furthermore, analysis of variance was used to study rotation and elevation of the motion segment as treatment factors. Cobbometer TDR angle measurements were most accurate (highest precision and lowest bias) at the centered position (95.5%), which placed the TDR directly inline with the x-ray beam source without any rotation. In contrast, the lowest accuracy (75.2%) was observed in the most rotated and off-centered view. A difference as high as 4 degrees between readings at any individual position, and as high as 6 degrees between all the positions was observed. Furthermore, the Cobbometer was unable to detect the expected trend in TDR angle projection with changing position. Although the Cobbometer has been reported to be reliable in different clinical applications, it lacks the needed accuracy to measure TDR angles and ROM. More accurate ROM measurement methods need to be developed to help surgeons and researchers assess radiological success of TDRs.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fetal MRI reconstruction aims at finding a high-resolution image given a small set of low-resolution images. It is usually modeled as an inverse problem where the regularization term plays a central role in the reconstruction quality. Literature has considered several regularization terms s.a. Dirichlet/Laplacian energy, Total Variation (TV)- based energies and more recently non-local means. Although TV energies are quite attractive because of their ability in edge preservation, standard explicit steepest gradient techniques have been applied to optimize fetal-based TV energies. The main contribution of this work lies in the introduction of a well-posed TV algorithm from the point of view of convex optimization. Specifically, our proposed TV optimization algorithm or fetal reconstruction is optimal w.r.t. the asymptotic and iterative convergence speeds O(1/n2) and O(1/√ε), while existing techniques are in O(1/n2) and O(1/√ε). We apply our algorithm to (1) clinical newborn data, considered as ground truth, and (2) clinical fetal acquisitions. Our algorithm compares favorably with the literature in terms of speed and accuracy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Articular surfaces reconstruction is essential in total shoulder arthroplasty. Because of the limited glenoid bone support, thin glenoid component could improve anatomical reconstruction, but adverse mechanical effects might appear. METHODS: With a numerical musculoskeletal shoulder model, we analysed and compared three values of thickness of a typical all-polyethylene glenoid component: 2, 4 (reference) and 6mm. A loaded movement of abduction in the scapular plane was simulated. We evaluated the humeral head translation, the muscle moment arms, the joint force, the articular contact pattern, and the polyethylene and cement stress. Findings Decreasing polyethylene thickness from 6 to 2mm slightly increased humeral head translation and muscle moment arms. This induced a small decreased of the joint reaction force, but important increase of stress within the polyethylene and the cement mantel. Interpretation The reference thickness of 4mm seems a good compromise to avoid stress concentration and joint stuffing.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background and Aims: The international EEsAI study group aims to develop, validate and evaluate the first pediatric EoE activity index (ped-EEsAI). We report on results of phase 1, which aims to generate candidate items. Methods: This study involves 3 phases: (1) item generation, (2) index derivation and testing on a first patient cohort, and (3) validation in a second cohort. In phase 1, item generation, weighting and reduction are achieved through a Delphi process with an international EoE expert group. The experts proposed and ranked candidate items on a 7-point Likert scale (0 = no, 6 = perfect relationship with EoE activity). Results: 23 international EoE experts proposed and ranked 39 items (20 clinical, 6 endoscopic, 8 histologic, 5 laboratory items). Rank order for clinical items: dysphagia related to food consistencies (median 5, range 2-6), severity of dysphagia (5, 3-6), frequency of dysphagia episodes (5, 3-6), regurgitation and vomiting (4, 2-5), response to dietary restrictions (4, 1-6); endoscopic items: whitish exudates (5, 3-6), furrowing (4, 3-6), corrugated rings (4, 2-6), linear shearing (4, 2-6), strictures (3, 2-6); histologic items: intraepithelial eosinophil count (5, 4-6), lamina propria fibrosis (3, 2-6), basal layer enlargement (3, 1-5); laboratory items: % blood eosinophils (3, 0-5). Conclusions: These items will now be reduced in further Delphi rounds, tested on a cohort of 100 pediatric EoE patients and validated in a second independent cohort, resulting in a robust, broadly accepted disease activity index for use in clinical trials and daily care.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

O objetivo deste trabalho foi avaliar o efeito de diferentes espécies de plantas, fontes de fósforo e calagem sobre a população microbiana total e solubilizadora de fosfato. Foram isolados fungos e bactérias capazes de solubilizar hidroxiapatita, proporcionando P solúvel. O experimento utilizado foi em blocos ao acaso com fatorial 3x3x2. E os fatores avaliados foram espécies de plantas (controle, braquiária e guandu), fertilizantes (controle, superfosfato simples e fosfato de rocha, ambos na dose de 400 kg ha-1 de P(2)0(5) ) e calagem (com e sem calcário). A população bacteriana cresceu pelo efeito da calagem, e a de fungos aumentou, independentemente da calagem, nas parcelas cultivadas com braquiária e fertilizadas com superfosfato. Foi constatado incremento de biomassa-P microbiana sobre o controle por influência da braquiária (23,9%), do superfosfato (30,9%) e da calagem (46,9%). O número de bactérias solubilizadoras foi favorecido pela calagem ou pelo plantio de guandu adubado com fosfato natural ou com braquiária sem adubação. Os fungos solubilizadores aumentaram na ausência de planta ou de adubação e na presença de guandu com fosfato natural. Finalmente, a calagem favoreceumais o crescimento dos fungos solubilizadores, em comparação com o controle, nos tratamentos fosfato natural, braquiária ou guandu.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In a prospective study, total hip arthroplasty (THA) patients were assessed preoperatively and postoperatively (n = 95) to determine if tender points (TPs) are associated with poor THA outcomes. Patients with high follow-up TP counts had higher visual analog scale (VAS) for pain and sleep, higher follow-up Western Ontario and McMaster Universities Arthritis Index (pain, stiffness, function), lower Health Assessment Questionnaire, Harris Hip, and Short Form 36 (physical functioning, bodily pain, physical component summary) scores. High follow-up TP were associated with increased pain, pain not relieved by surgery, poor function, and poor sleep. Visual analog scale pain and sleep, Short Form 36 (physical functioning, bodily pain), Western Ontario and McMaster Universities Arthritis Index, Health Assessment Questionnaire, and Harris hip scores improved significantly after THA; TP scores did not. Higher preoperative TP were predictive of higher follow-up TP but were poorly predictive of poor outcome measures after surgery in individual patients, suggesting that preoperative TPs are contraindicative for THA.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

AIMS: The objectives of this study were to analyse (a) the distribution of risky single-occasion drinking (RSOD) among 19-year-old men in Switzerland and (b) to show the percentage of all alcohol consumption in the form of RSOD. METHODS: The study was based on a census of Swiss francophone 19-year-old men consecutively reporting for processing. The study was conducted at Army Recruitment Center. The participants were 4116 recruits consecutively enrolling for mandatory army recruitment procedures between 23 January and 29 August in 2007. The measures were alcohol consumption measured in drinks of approximately 10 g of pure alcohol, number of drinking occasions with six or more drinks (RSOD) in the past 12 months and a retrospective 1 week drinking diary. RESULTS: 264 recruits were never seen by the research staff, 3536 of the remaining 3852 conscripts completed a questionnaire which showed that 7.2% abstained from alcohol and 75.5% of those drinking had an RSOD day at least monthly. The typical frequency of drinking was 1-3 days per week on weekends. The average quantity on weekends was about seven drinks, 69.3% of the total weekly consumption was in the form of RSOD days, and of all the alcohol consumed, 96.2% was by drinkers who had RSOD days at least once a month. CONCLUSION: Among young men, RSOD constitutes the norm. Prevention consequently must address the total population and not only high-risk drinkers.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Total hip replacement has seen a tremendous development and has become one of the most successful surgical interventions in orthopaedics. While during the first decades of development of total hip arthroplasty the fixation of the implant into the bone was the main concern, the focus has shifted towards surgical technique and soft tissue handling. In order to avoid permanent soft tissue damage, muscular dysfunction and concerns in regards to cosmetics, minimal invasive and anatomic approaches have been developed. We here provide a short overview on various methods of total hip replacements and we describe our technique through a minimal invasive direct anterior approach. While muscle and nerve damage is minimal, this technique allows for a rapid rehabilitation and is associated with an excellent functional outcome and a minimal risk for dislocation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

O trabalho teve como objetivo avaliar quinzenalmente, em 1996 e 1997, a variação do potencial total da água ao longo do tempo, em solos de uma toposseqüência de tabuleiro localizada em Sapeaçu, BA. Esta toposseqüência tinha as seguintes características: a) comprimento de 190 m; b) declividade média de 0,097 m m-1; c) cultivo com laranja; d) Latossolo Amarelo argissólico coeso, no terço superior; e) Argissolo Amarelo coeso, no terço médio; f) Argissolo Acinzentado não coeso, no terço inferior. A umidade do solo foi medida com sonda de nêutrons, nas profundidades de 0,30, 0,70, 1,10 e 1,50 m. Com base nas respectivas curvas de retenção, obteve-se o potencial matricial e, em seguida, o potencial total da água, para cada solo, profundidade e tempo. A camada coesa dificulta o fluxo de água no solo, tanto no processo de molhamento como no de secamento. Em conseqüência, o potencial total da água em solos com camada coesa varia bruscamente na camada mais superficial, ao longo do tempo, e mais lentamente nas camadas mais profundas. Em solo não coeso, a variação brusca do potencial ocorre apenas na camada mais superficial. O limite de tensão de água no solo de -1.500 kPa como sendo o ponto de murchamento permanente não se aplica à cultura dos citros.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Juvenile nasopharyngeal angiofibroma (JNA) is a rare vascular neoplasm occurring almost exclusively in adolescent males. Although benign, it is often locally aggressive and can erode into surrounding tissues and structures resulting in significant morbidity and mortality. In 20% of cases, there is intracranial extension. In this paper, we report on the total excision of a large, recurrent JNA with intracranial extension into the middle cranial fossa encroaching into the cavernous sinus, by right temporal craniotomy and extended osteoplastic maxillotomy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

La planification scanographique (3D) a démontré son utilité pour une reconstruction anatomique plus précise de la hanche (longueur du fémur, centre de rotation, offset, antéversion et rétroversion). Des études ont montré que lors de la planification 2D 50% seulement correspondaient à l'implant définitif du fémur alors que dans une autre étude ce taux s'élevait à 94% pour une planification 3D. Les erreurs étaient liées à l'agrandissement des radiographies. L'erreur sur la taille de la tige est liée à l'estimation inadéquate de la morphologie osseuse ainsi qu'à la densité osseuse. L'erreur de l'antéversion, augmentée par l'inclinaison du bassin, a pu être éliminée par la planification 3D et l'offset restauré dans 98%. Cette étude est basée sur une nouvelle technique de planification scanographique en trois dimensions pour une meilleure précision de la reconstruction de la hanche. Le but de cette étude est de comparer l'anatomie post-opératoire à celle préopératoire en comparant les tailles d'implant prévu lors de la planification 3D à celle réellement utilisée lors de l'opération afin de déterminer l'exactitude de la restauration anatomique avec étude des différents paramètres (centre de rotation, densité osseuse, L'offset fémoral, rotations des implants, longueur du membre) à l'aide du Logiciel HIP-PLAN (Symbios) avec évaluation de la reproductibilité de notre planification 3D dans une série prospective de 50 patients subissant une prothèse totale de hanche non cimentée primaire par voie antérieure. La planification pré-opératoire a été comparée à un CTscan postopératoire par fusion d'images. CONCLUSION ET PRESPECTIVE Les résultats obtenus sont les suivants : La taille de l'implant a été prédit correctement dans 100% des tiges, 94% des cupules et 88% des têtes (longueur). La différence entre le prévu et la longueur de la jambe postopératoire était de 0,3+2,3 mm. Les valeurs de décalage global, antéversion fémorale, inclinaison et antéversion de la cupule étaient 1,4 mm ± 3,1, 0,6 ± 3,3 0 -0,4 0 ± 5 et 6,9 ° ± 11,4, respectivement. Cette planification permet de prévoir la taille de l'implant précis. Position de la tige et de l'inclinaison de la cupule sont exactement reproductible. La planification scanographique préopératoire 3D permet une évaluation précise de l'anatomie individuelle des patients subissant une prothèse totale de hanche. La prédiction de la taille de l'implant est fiable et la précision du positionnement de la tige est excellente. Toutefois, aucun avantage n'est observée en termes d'orientation de la cupule par rapport aux études impliquant une planification 2D ou la navigation. De plus amples recherches comparant les différentes techniques de planification pré-opératoire à la navigation sont nécessaire.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

AIM: Total imatinib concentrations are currently measured for the therapeutic drug monitoring of imatinib, whereas only free drug equilibrates with cells for pharmacological action. Due to technical and cost limitations, routine measurement of free concentrations is generally not performed. In this study, free and total imatinib concentrations were measured to establish a model allowing the confident prediction of imatinib free concentrations based on total concentrations and plasma proteins measurements. METHODS: One hundred and fifty total and free plasma concentrations of imatinib were measured in 49 patients with gastrointestinal stromal tumours. A population pharmacokinetic model was built up to characterize mean total and free concentrations with inter-patient and intrapatient variability, while taking into account α1 -acid glycoprotein (AGP) and human serum albumin (HSA) concentrations, in addition to other demographic and environmental covariates. RESULTS: A one compartment model with first order absorption was used to characterize total and free imatinib concentrations. Only AGP influenced imatinib total clearance. Imatinib free concentrations were best predicted using a non-linear binding model to AGP, with a dissociation constant Kd of 319 ng ml(-1) , assuming a 1:1 molar binding ratio. The addition of HSA in the equation did not improve the prediction of imatinib unbound concentrations. CONCLUSION: Although free concentration monitoring is probably more appropriate than total concentrations, it requires an additional ultrafiltration step and sensitive analytical technology, not always available in clinical laboratories. The model proposed might represent a convenient approach to estimate imatinib free concentrations. However, therapeutic ranges for free imatinib concentrations remain to be established before it enters into routine practice.