Resumo:
The effect of addition of rosemary and oregano extracts on the sensory quality of irradiated beef burger was investigated. Batches of beef burgers were prepared with 400 ppm of rosemary or oregano extract and a group prepared with 200 ppm of synthetic butyl-hydroxytoluene (BHT)/butyl-hydroxy-anisol (BHA) was used as a control. Half of each formulation was irradiated at the maximum dose allowed for frozen meat (7 kGy). Samples were kept under frozen conditions (-20 degrees C) during the whole storage period, including during irradiation. Two analyses were performed after 20 and 90 days to verify the influence of the addition of the different types of antioxidants and the effect of irradiation and storage time on the acceptance of the product. Thirty-three and thirty-four untrained panelists were invited to participate in the first and second test, respectively. A structured hedonic scale ranging from 1 to 9 points was used in both analyses. BHT/BHA formulation obtained the highest score (6.73) and regarding the natural antioxidants, oregano received better acceptance (6.36). Irradiated samples formulated with oregano received a lower score, 6.03 in the first test and 5.06 in the second one, compared to the non-irradiated sample (6.36 and 5.79). In the second test (90 days), the sample formulated with BHT/BHA and which was irradiated received a higher score (6.59) when compared to the non-irradiated one (5.85). In both tests, the irradiated samples formulated with rosemary extract obtained a better score compared to the non-irradiated one, the scores being 5.00-3.82 and 5.00-3.76 in the first and second test, respectively. Our results allowed us to conclude that the natural antioxidants, rosemary and oregano extracts, present a good alternative for replacing synthetic additives in food industries, and that the irradiation process, in some cases, may help to enhance the sensory quality of food. (C) 2008 Elsevier Ltd. All rights reserved.
Resumo:
Development and Characterization of L-Alanyl-L-Glutamine Containing Pellets employing Extrusion-Spheronization Method and Drying Process in Fluidized Bad Equipment"". In this work, five formulations of L-alanyl-L-glutamine (glutamine dipeptide) containing pellets with different drug concentration were developed and evaluated: F1 (9.07%); F2 (17.70%); F3 (27.98%); F4 (37.74%) e F5 (47.53%). Pellets were prepared by extrusion-spheronization method and, further, dried in fluidized bad equipment. The following assays were carried out with the batches obtained: granulometry, friability, true density and morphologic analysis. Between the five formulations evaluated, pellets obtained from F3 present best yield (75.80%), most uniform particle size distribution (89.67% of pellets with size in the range of 0.80 to 1.18), most high true density (2.1634 g/ml) and best aspect (1.0795 +/- 0.0410). Due to these features, pellets obtained from F3 were considered adequate to further polymeric coating process in order to produce a multiparticulate system to prolong L-alanyl-L-glutamine release.
Resumo:
Sodium diclofenac (SD) release from dosage forms has been studied under different conditions. However, no dissolution method that is discriminatory enough to reflect slight changes in formulation or manufacturing process, and which could be effectively correlated with the biological properties of the dosage form, has been reported. This study sought to develop three different formulae of SD-containing matrix tablets and to determine the effect of agitation speed in its dissolution profiles. F1, F2 and F3 formulations were developed using hypromellose (10, 20 and 30%, respectively for F1, F2 and F3) and other conventional excipients. Dissolution tests were carried out in phosphate buffer pH 6.8 at 37 degrees C using apparatus 11 at 50, 75 or 100 rpm. Dissolution efficiency (DE), T(50) and T(90) were determined and plotted as functions of the variables agitation speed and hypromellose concentration. Regarding DE, F2 showed more sensitivity to variations in agitation speed than F1 and F3. Increasing hypromellose concentration reduced DE values, independent of agitation speed. Analysis of T(50) and T(90) suggests that F1 is less sensitive to variations in agitation speed than F2 and F3. Most discriminatory dissolution conditions were observed at 50 rpm. Results suggest that the comparison of dissolution performance of SD matrix tablets should take into account polymer concentration and agitation conditions. (C) 2009 Published by Elsevier B.V.
Resumo:
A reversed-phase high performance liquid chromatographic (RP-HPLC) method for determination of econazole nitrate, preservatives (methylparaben and propylparaben) and its main impurities (4-chlorobenzl alcohol and alpha-(2,4-dicholorophenyl)-1H-imidazole-1-ethanol) in cream formulations, has been developed and validated. Separation was achieved on a column Bondclone (R) C18 (300 mm x 3.9 mm i.d., 10 mu m) using a gradient method with mobile phase composed of methanol and water. The flow rate was 1.4 mL min(-1), temperature of the column was 25 C and the detection was made at 220 nm. Miconazole nitrate was used as an internal standard. The total run time was less than 15 min, The analytical curves presented coefficient of correlation upper to 0.99 and detection and quantitation limits were calculated for all molecules. Excellent accuracy and precision were obtained for econazole nitrate. Recoveries varied from 97.9 to 102.3% and intra- and inter-day precisions, calculated as relative standard deviation (R.S.D), were lower than 2.2%. Specificity, robustness and assay for econazole nitrate were also determined. The method allowed the quantitative determination of econazole nitrate, its impurities and preservatives and could be applied as a stability-indicating method for econazole nitrate in cream formulations. (C) 2008 Elsevier B.V. All rights reserved.
Resumo:
The purpose of this paper was to produce controlled-release matrices with 120 mg of propranolol hydrochloride (PHCl) employing hydroxypropyl methylcellulose (HPMC, Methocel (R) K100) as the gel forming barrier. Although this class of polymers has been commonly used for direct compression, with the intent of use reduced polymer concentrations to achieve controlled drug release, in this study tablets were produced by the wet granulation process. HPMC percentages ranged from 15-34 % and both soluble and non soluble diluents were tested in the 10 proposed tablet compositions. Dissolution testing of matrices was performed over a 12 h period in 1.2 pH medium (the first 2 h) and in pH 6.8 (10 h). Dissolution kinetic analysis was performed by applying Zero-order, First-order and Higuchi models with the aim of elucidating the drug release mechanism. All physical-chemical characteristics such as average weight, friability, hardness, diameter, height, and drug content were in accordance to the pharmacopeial specifications. Taking into account that PHCl is a very soluble drug, low concentrations (15 %) of HPMC were sufficient to reduce the drug release and to promote controlled release of PHCl, presenting good dissolution efficiencies, between 50 % and 63 %. The Higuchi model has presented the best fit to the 15 % HPMC formulations, indicating that the main release mechanism was diffusion. It could be concluded that the application of the wet granulation method reduced matrices erosion and promoted controlled release of the drug at low HPMC percentages.
Resumo:
introducing a pharmaceutical product on the market involves several stages of research. The scale-up stage comprises the integration of previous phases of development and their integration. This phase is extremely important since many process limitations which do not appear on the small scale become significant on the transposition to a large one. Since scientific literature presents only a few reports about the characterization of emulsified systems involving their scaling-up, this research work aimed at evaluating physical properties of non-ionic and anionic emulsions during their manufacturing phases: laboratory stage and scale-up. Prototype non-ionic (glyceryl monostearate) and anionic (potassium cetyl phosphate) emulsified systems had the physical properties by the determination of the droplet size (D[4,3 1, mu m) and rheology profile. Transposition occurred from a batch of 500-50,000 g. Semi-industrial manufacturing involved distinct conditions: intensity of agitation and homogenization. Comparing the non-ionic and anionic systems, it was observed that anionic emulsifiers generated systems with smaller droplet size and higher viscosity in laboratory scale. Besides that, for the concentrations tested, augmentation of the glyceryl monostearate emulsifier content provided formulations with better physical characteristics. For systems with potassium cetyl phosphate, droplet size increased with the elevation of the emulsifier concentration, suggesting inadequate stability. The scale-up provoked more significant alterations on the rheological profile and droplet size on the anionic systems than the non-ionic. (C) 2008 Elsevier B.V. All rights reserved.
Resumo:
A simple, fast, inexpensive and reliable capillary zone electrophoresis (CZE) method for the determination of econazole nitrate in cream formulations has been developed and validated. Optimum conditions comprised a pH 2.5 phosphate buffer at 20 mmol L(-1) concentration, +30 kV applied voltage in a 31.5 cm x 50 mu m I.D. capillary. Direct UV detection at 200 nm led to an adequate sensitivity without interference from sample excipients. A single extraction step of the cream sample in hydrochloric acid was performed prior to injection. Imidazole (100 mu g mL(-1)) was used as internal standard. Econazole nitrate migrates in approximately 1.2 min. The analytical curve presented a coefficient of correlation of 0.9995. Detection and quantitation limits were 1.85 and 5.62 mu g mL(-1), respectively. Excellent accuracy and precision were obtained. Recoveries varied from 98.1 to 102.5% and intra- and inter-day precisions, calculated as relative standard deviation (RSD), were better than 2.0%. The proposed CZE method presented advantageous performance characteristics and it can be considered suitable for the quality control of econazole nitrate cream formulations. (c) 2008 Elsevier B.V. All rights reserved.
Resumo:
The aim of the present study was to provide a numerical measure, through the process capability indexes (PCIs), C(p) and C(pk), on whether or not the manufacturing process can be considered capable of producing metamizol (500 mg) tablets. They were also used as statistical tool in order to prove the consistency of the tabletting process, making sure that the tablet weight and the content uniformity of metamizol are able to comply with the preset requirements. Besides that, the ANOVA, the t-test and the test for equal variances were applied to this study, allowing additional knowledge of the tabletting phase. Therefore, the proposed statistical approach intended to assure more safety, precision and accuracy on the process validation analysis.
Resumo:
A simplex-lattice statistical project was employed to study an optimization method for a preservative system in an ophthalmic suspension of dexametasone and polymyxin B. The assay matrix generated 17 formulas which were differentiated by the preservatives and EDTA (disodium ethylene diamine-tetraacetate), being the independent variable: X-1 = chlorhexidine digluconate (0.010 % w/v); X-2 = phenylethanol (0.500 % w/v); X-3 = EDTA (0.100 % w/v). The dependent variable was the Dvalue obtained from the microbial challenge of the formulas and calculated when the microbial killing process was modeled by an exponential function. The analysis of the dependent variable, performed using the software Design Expert/W, originated cubic equations with terms derived from stepwise adjustment method for the challenging microorganisms: Pseudomonas aeruginosa, Burkholderia cepacia, Staphylococcus aureus, Candida albicans and Aspergillus niger. Besides the mathematical expressions, the response surfaces and the contour graphics were obtained for each assay. The contour graphs obtained were overlaid in order to permit the identification of a region containing the most adequate formulas (graphic strategy), having as representatives: X-1 = 0.10 ( 0.001 % w/v); X-2 = 0.80 (0.400 % w/v); X-3 = 0.10 (0.010 % w/v). Additionally, in order to minimize responses (Dvalue), a numerical strategy corresponding to the use of the desirability function was used, which resulted in the following independent variables combinations: X-1 = 0.25 (0.0025 % w/v); X-2 = 0.75 (0.375 % w/v); X-3 = 0. These formulas, derived from the two strategies (graphic and numerical), were submitted to microbial challenge, and the experimental Dvalue obtained was compared to the theoretical Dvalue calculated from the cubic equation. Both Dvalues were similar to all the assays except that related to Staphylococcus aureus. This microorganism, as well as Pseudomonas aeruginosa, presented intense susceptibility to the formulas independently from the preservative and EDTA concentrations. Both formulas derived from graphic and numerical strategies attained the recommended criteria adopted by the official method. It was concluded that the model proposed allowed the optimization of the formulas in their preservation aspect.
Resumo:
The ascorbate oxidase is the enzyme used to determine the content of ascorbic acid in the pharmaceutical and food industries and clinics analyses. The techniques currently used for the purification of this enzyme raise its production cost. Thus, the development of alternative processes and with the potential to reduce costs is interesting. The application of aqueous two-phase system is proposed as an alternative to purification because it enables good separation of biomolecules. The objective of this study was to determine the conditions to continuously pre-purify the enzyme ascorbate oxidase by an aqueous two-phase system (PEG/citrate) using rotating column provided with perforated discs. Under the best conditions (20,000 g/mol PEG molar mass, 10% PEG concentration, and 25% citrate concentration), the system showed satisfactory results (partition coefficient, 3.35; separation efficiency, 54.98%; and purification factor, 1.46) and proved suitable for the pre-purification of ascorbate oxidase in continuous process.
Resumo:
The scope of this research work was to investigate biogas production and purification by a two-step bench-scale biological system, consisting of fed-batch pulse-feeding anaerobic digestion of mixed sludge, followed by methane enrichment of biogas by the use of the cyanobacterium Arthrospira platensis. The composition of biogas was nearly constant, and methane and carbon dioxide percentages ranged between 70.5-76.0% and 13.2-19.5%, respectively. Biogas yield reached a maximum value (about 0.4 m(biogas)(3)/kgCOD(i)) at 50 days-retention time and then gradually decreased with a decrease in the retention time. Biogas CO(2) was then used as a carbon source for A. platensis cultivation either under batch or fed-batch conditions. The mean cell productivity of fed-batch cultivation was about 15% higher than that observed during the last batch phase (0.035 +/- 0.006 g(DM)/L/d), likely due to the occurrence of some shading effect under batch growth conditions. The data of carbon dioxide removal from biogas revealed the existence of a linear relationship between the rates of A. platensis growth and carbon dioxide removal from biogas and allowed calculating carbon utilization efficiency for biomass production of almost 95%. (C) 2009 Elsevier Ltd. All rights reserved.
Resumo:
Ethylene oxide (EO) is used to sterilize Oxygenator and Tubing applied to heart surgery. Residual levels of EO and its derivatives, ethylene chlorohydrin (ECH) and ethylene glycol (EG), may be hazardous to the patients. Therefore, it must be removed by the aeration process. This study aimed to estimate the minimum aeration time for these devices to attain safe limits for use (avoiding excessive aeration time) and to evaluate the Green Fluorescent Protein (GFP) as a biosensor capable of best indicating the distribution and penetration of EO gas throughout the sterilization chamber. Sterilization cycles of 2, 4, and 8 h were monitored by Bacillus atrophaeus ATCC 9372 as a biological indicator (131) and by the GFP. Residual levels of EO, ECH, and EG were determined by gas chromatography (GC), and the residual dissipation was studied. Safe limits were reached right after the sterilization process for Oxygenator and after 204 h of aeration for Tubing. In the 2 h cycle, the GFP concentration decreased from 4.8 (+/- 3.2)% to 7.5 (+/- 2.5)%. For the 4 h cycle, the GFP concentration decreased from 17.4 (+/- 3.0)% to 21.5 (+/- 6.8)%, and in the 8 h cycle, it decreased from 22.5 (+/- 3.2)% to 23.9 (+/- 3.9)%. This finding showed the potentiality for GFP applications as an EO biosensor. (C) 2009 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater 9113: 626-630, 2009
Resumo:
In this study, fluid precursor formulations for subcutaneous injection and in situ formation of hexagonal phase gels upon water absorption were developed as a strategy to sustain the release of naltrexone, a drug used for treatment of drug addiction. Precursor formulations were obtained by combining BRIJ 97 with propylene glycol (PG, 5-70%, w/w). To study the phase behavior of these formulations, water was added at 10-90% (w/w), and the resulting systems were characterized by polarized light microscopy. Two precursor formulations containing BRIJ:PG at 95:5 (w/w, referred to as BRIJ-95) and at 80:20 (w/w, referred to as BRIJ-80) were chosen. Naltrexone was dissolved at 1% or suspended at 5% (w/w). Precursor formulations were transformed into hexagonal phases when water content exceeded 20%. Water uptake followed second-order kinetics, and after 2-4 h all precursor formulations were transformed into hexagonal phases. Drug release was prolonged by the precursor formulations (compared to a drug solution in PBS), and followed pseudo-first order kinetics regardless of naltrexone concentration. The release from BRIJ-80 was significantly higher than that from BRIJ-95 after 48 h. The relative safety of the precursor formulations was assessed in cultured fibroblasts. Even though BRIJ-95 was more cytotoxic than BRIJ-80, both precursor formulations were significantly less cytotoxic than sodium lauryl sulfate (considered moderate-to-severe irritant) at the same concentration (up to 50 mu g/mL). These results suggest the potential of BRIJ-based precursor formulations for sustained naltrexone release. (C) 2011 Elsevier By. All rights reserved.
Resumo:
This article presents an evaluation of the effects of the spouted bed design and operating conditions on system fluiddynamics and process performance during enteric coating of hard gelatine capsules. The design parameters studied were the column diameter (150 mm and 200 mm), the included angle of the conical base, gamma (60 degrees or 40 degrees) and the presence or absence of a Venturi inserted before the inlet air orifice. The process variables studied were the ratio between the feed flow rate of the coating suspension to the spouting gas flow rate (W(s)/W(g)), the mass of capsules loaded to the equipment (M(0)), and the ratio between the Spouting gas flow rate to the gas flow rate at minimum spouting condition (Q/Q(ms)). The response variables were the rate of increase of the capsules mass (K(1)), and the adhesion efficiency (eta). The linear regression equation for the dependent variable K, in terms of the independent variables adequately described the process with an r(2) value of 0.872. Analysis of variance (ANOVA) revealed that increasing of W(s)/W(g), Q/Q(ms) and gamma significantly increased the adhesion efficiency. Adhesion efficiencies higher than 90% were achieved by selecting precise coating conditions, indicating the feasibility of the process for coating of hard gelatine capsules. (C) 2008 Elsevier B.V. All rights reserved.
Resumo:
Bone morphogenetic proteins (BMPs) are multi-functional growth factors belonging to the transforming growth factor beta superfamily, especially BMP-2, induce bone formation in vivo, and clinical application in repair of bone fractures and defects is expected. However, appropriate systems to delivery BMPs for practical use need to be developed with the objective to heal cartilage and bone-related diseases in medical, dental and veterinary practice. Thus, the aim of this article was to present an overview of the principals carriers used to delivery BMPs and alternative delivery systems for these proteins.