887 resultados para standardised tests
Resumo:
The mechanisms of material removal and the interactions among scratches performed in ceramic materials were investigated using acoustic emission signals, and scanning electron microscopy, in scratching experiments. Several testing conditions were used to produce different types of removing mechanism on a glass as well as on a polycrystalline alumina sample composed by heterogeneous grain size. It is known that the material removing process on a polycrystalline ceramic involves intergranular microfracture and grain dislodgement, unlike the chipping produced by the extension of lateral cracks in non-granular materials, such as glass. Distinct settings for velocities, loads, and two types of diamond indenter were tested. The material removal was carried out by three different methods of scratching: single passes, repeated overlapping passes, and parallel scratches. As a general result, there was a clear relationship between the acoustic emission signals and the damage intensity occurred in the material removal. More specifically, there were differences in the acoustic emission signal levels in the scratches made on the alumina and on the glass owing to the material removal mechanisms associated with the structure of these materials. A gradual increase in the acoustic emission levels was observed when the number of repeated passes was increased as a result of the damage accumulation process followed by severe material removal. It was also noticed that the acoustic emission signals were capable of reflecting the interactions between two parallel scratches.
Resumo:
The running velocities associated to lactate minimum (V-lm), heart rate deflection (V-HRd), critical velocity (CV), 3000 M (V-3000) and 10000 m performance (V-10km) were compared. Additionally the ability of V-lm and VHRd on identifying sustainable velocities was investigated.Methods. Twenty runners (28.5 +/- 5.9 y) performed 1) 3000 m running test for V3000; 2) an all-out 500 in sprint followed by 6x800 m incremental bouts with blood lactate ([lac]) measurements for V-lm; 3) a continuous velocity-incremented test with heart rate measurements at each 200 m for V-HRd; 4) participants attempted to 30 min of endurance test both at V-lm(ETVlm) and V-HRd(ETVHRd). Additionally, the distance-time and velocity-1/time relationships produced CV by 2 (500 m and 3000 m) or 3 predictive trials (500 m, 3000 m and distance reached before exhaustion during ETVHRd), and a 10 km race was recorded for V-10km.Results. The CV identified by different methods did not differ to each other. The results (m(.)min(-1)) revealed that V-.(lm) (281 +/- 14.8)< CV (292.1 +/- 17.5)=V-10km (291.7 +/- 19.3)< V-HRd (300.8 +/- 18.7)=V-3000 (304 +/- 17.5) with high correlation among parameters (P < 0.001). During ETVlm participants completed 30 min of running while on the ETVHRd they lasted only 12.5 +/- 8.2 min with increasing [lac].Conclusion. We evidenced that CV and Vim track-protocols are valid for running evaluation and performance prediction and the parameters studied have different significance. The V-lm reflects the moderate-high intensity domain (below CV), can be sustained without [lac] accumulation and may be used for long-term exercise while the V-HRd overestimates a running intensity that can be sustained for long-time. Additionally, V-3000 and V-HRd reflect the severe intensity domain (above CV).
Resumo:
Flotation has been widely used in studies of recent foraminifera in order to concentrate tests and save time during picking. In this paper, four flotation agents with different densities were compared: (1) trichloroethylene, TCE (C2HCl3), with a density of 1.46 g mL(-1); (2) sodium nitrate/sodium thiosulfate solution, SNT (NaNO3 + Na2O3S2 center dot 5H(2)O), with a density of 1.46 g mL(-1); (3) zinc chloride Solution, ZC (ZHCl(2)), with a density of 1.70 g mL(-1); and (4) sodium polytungstate solution, SPT (3Na(2)WO(4) center dot 9WO(3) center dot 5H(2)O), with a density of 2.50 g mL(-1). Comparison was carried out by means of qualitative and quantitative data. Results showed that ZC and SPT were the best flotation agents, recovering 91% and 96% of the total tests, respectively, whereas TCE and SNT recovered 59.1% and 72.8%, respectively. Both quantitative and qualitative results significantly improved with a higher density of the flotation liquid. Therefore, substitution of TCE with ZC or SPT solutions is strongly encouraged, because they are, additionally, less harmful to health and the environment. ZC is the most cost-effective, since its results were not significantly different from those of the SPT treatment. Carbon tetrachloride (CCl4) was not considered in this comparative study, because it has been banned in many countries and it is highly harmful to health and the environment.
Resumo:
The dilatometer test results have been lately applied in foundation design for prediction of settlement and bearing capacity problems. The equipment, its calibration, test procedures and test data interpretation are simple. These advantages seem to explain the increasing use of the dilatometer (DMT) test as a routine technique for subsoil investigation. The DMT test boreholes were carried out on the grounds of the National Research Council (NRC) in Ottawa. Several test results based on laboratory, and other in situ tests available in the literature for the Leda clay deposit in Ottawa area were used to provide correlations between geotechnical properties and soil index parameters as proposed by Marchetti (1980). More appropriated relationships, even though preliminaries, are presented for the crust layer.
Resumo:
The aim of this study was to verify the correlation between the Wingate arm crank test outputs (peak power, mean power, and fatigue index), obtained on a specific ergometer, and the performance in crawl stroke swim sprints of 14, 25, 50, and 400 m. The experiment was conducted with 9 healthy male volunteers (18.1 +/- 2.2 years of age; 172 +/- 0.04 cm; 67.7 +/- 5.92 kg and 15.7 +/- 4.57% body fat). on determined days, all individuals were submitted to the Wingate arm crank test and crawl freestyle sprints of 14, 25, 50, and 400 m as they were timed with a stopwatch. The peak power, the mean power, and the fatigue index, which were obtained during the Wingate arm crank test, were not significantly correlated with the maximum swim velocities during the crawl free-style tests of 14 (r = 0.40; r = 0.64; r = 0.11), 25 (r = 0.28; r = 0.39; r = -0.27), 50 (r = 0.03; r = 0.09; r = -0.31), and 400 (r = -0.52; r = -0.37; r = -0.65) m respectively. Thus, it is possible to conclude that the Wingate arm crank test is not suitable to assess the anaerobic power of swimmers under the described experimental conditions.
Resumo:
Skin tests were done using larval extract and excretory-secretory (ES) antigens injected intradermally in the neck area of 30, 11- to 200-day-old buffalo calves and nine 27- to 100-day postparturition buffalo cows, the skin of the buffaloes infected with Toxocara vitulorum, mainly calves, demonstrated a hypersensitive response to antigens, especially to the larval extract antigens. Skin hypersensitivity responses were characterized by the presence of dermal nodules with progressive induration and an increase of up to four times the size of the original area at 30 min (immediate type) and at 72 h (delayed type) after injection, Histological preparations of skin reactions at 72 h showed a typical mononuclear cell infiltration, with eosinophils and perivascular cuffing in most of the animals, Fecal examination of 75 animals showed that 65 (86.7%) buffalo calves (9-115 days old) were parasitized with T. vitulorum. The peak of egg output from these animals occurred when they were approximately 45 days old.
Resumo:
Diagnosis of Neospora caninum infection in dogs is based on serological assays such as the indirect fluorescent antibody test (IFAT) and enzyme-linked immunosorbent assays (ELISA). This study evaluated two serological tests (IFAT and ELISA) for the detection of IgG antibodies to N. caninum in 300 serum samples of dogs through the optimization of cut off titers by using the two-graph receiveroperating characteristic (TG-ROC) curve. In addition, the identification of major cross-reactive antigens with Toxoplasma gondii was investigated by inhibition ELISA and immunoblotting (IB) assays. IFAT and ELISA results showed 74% agreement, with a good negative concordance (P-neg=0.83), but a poor positive concordance (P-pos=0.42). The great majority (86%) of sera with positive concordant results (IFAT+/ELISA+) recognized at least two out of three N. caninum immunodominant antigens, particularly the 29-32 and 35-37 kDa bands. Optimization of cut off titers in IFAT and ELISA was performed considering the reactivity to at least two out of three N. caninum immunodominant antigens as infection markers, obtaining a titer of 50 for IFAT and 200 for ELISA. Seropositivity to N. caninuin was significantly associated with T gondii-seropositive samples, particularly in ELISA (55.4%). Inhibition ELISA curves for N. caninum showed a partial heterologous inhibition, indicating some degree of cross-reactivity between N. caninum and T gondii antigens. Inhibition IB assays showed a moderate heterologous inhibition for N. caninum antigens above 45-50 kDa. These results indicate that ELISA should be used critically when crude tachyzoite antigen preparations are employed, due to possible cross-reactivity with other related parasites as T gondii. Also, the cut off dilution of 1:50 in IFAT showed to be the most appropriated for N. caninum serology in dogs. Therefore, we suggest that N. caninum immunodominant antigens, specially the 17 and 29-32 kDa proteins, should be selected markers in serological assays for canine neosporosis. (c) 2006 Elsevier B.V. All rights reserved.
Resumo:
The need for standardization of the measured blow count number N-spt into a normalized reference energy value is now fully recognized. The present paper extends the existing theoretical approach using the wave propagation theory as framework and introduces an analysis for large displacements enabling the influence of rod length in the measured N-spt values to be quantified. The study is based on both calibration chamber and field tests. Energy measurements are monitored in two different positions: below the anvil and above the sampler. Both experimental and numerical results demonstrate that whereas the energy delivered into the rod stem is expressed as a ratio of the theoretical free-fall energy of the hammer, the effective sampler energy is a function of the hammer height of fall, sampler permanent penetration, and weight of both hammer and rods. Influence of rod length is twofold and produces opposite effects: wave energy losses increase with increasing rod length and in a long rod composition the gain in potential energy from rod weight is significant and may partially compensate measured energy losses. Based on this revised approach, an analytical solution is proposed to calculate the energy delivered to the sampler and efficiency coefficients are suggested to account for energy losses during the energy transference process.
Resumo:
We have investigated if a new LEDs system has enough efficient energy to promote efficient shear and tensile bonding strength resistance under standardized tests. LEDs 470 +/- 10 nm can be used to photocure composite during bracket fixation. Advantages considering resistance to tensile and shear bonding strength when these systems were used are necessary to justify their clinical use. Forty eight human extracted premolars teeth and two light sources were selected, one halogen lamp and a LEDs system. Brackets for premolar were bonded through composite resin. Samples were submitted to standardized tests. A comparison between used sources under shear bonding strength test, obtained similar results; however, tensile bonding test showed distinct results: a statistical difference at a level of 1% between exposure times (40 and 60 seconds) and even to an interaction between light source and exposure time. The best result was obtained with halogen lamp use by 60 seconds, even during re-bonding; however LEDs system can be used for bonding and re-bonding brackets if power density could be increased.
Resumo:
This article aims to demonstrate through performance tests, that it is possible to reuse outdated machines as effective and productive terminals, with the use of LTSP - Linux Terminal Service Project. Additionally, we will demonstrate that companies and institutions concerned with the environment may find this alternative a measure of computational saving and recycling.