826 resultados para police interrogation


Relevância:

20.00% 20.00%

Publicador:

Resumo:

A novel high-frequency fiber Bragg grating (FBG) sensing interrogation system by using fiber Sagnac-loop-based microwave photonic filtering is proposed and experimentally demonstrated. By adopting the microwave photonic filtering, the wavelength shift of sensing FBG can be converted into amplitude variation of the modulated electronic radio-frequency (RF) signal. In the experiment, the strain applied onto the sensing FBG has been demodulated by measuring the intensity of the recovered RF signal, and by modulating the RF signal with different frequencies, different interrogation sensitivities can be achieved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A low-cost high-resolution wavelength-division-multiplexing (WDM) interrogation system operating around 800 nm region with operational bandwidth up to 60 nm and resolution of 12.7 pm utilizing a tilted fiber Bragg grating (TFBG) and a CCDarray detector has been implemented. The system has been evaluated for interrogating fiber Bragg grating based strain, temperature sensors, giving sensitivities of 0.59 pm/µe and 5.6 pm/°C, which are in good agreement with previously reported values. Furthermore, the system has been utilized to detect the refractive index change of sample liquids, demonstrating a capability of measuring index change as small as 10¯5. In addition, the vectorial expression of phase match condition and fabrication of TFBG have been discussed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Consultation between the police and the community was a recommendation of Lord Scarman in his report into the Brixton riots in 1981. By 1982 the West Midlands Police Authority had established local consultative committees on each police sub-division. This thesis is a study of four Police Consultative Committees in Birmingham, using qualitative methods of attendance at committee meetings and interviews with committee members. The research was carried out between 1990 and 1992 - ten years after formal consultation was established, and aimed to examine the relationship between the micro social processes of the committees and key sociological theoretical concepts. The analysis of the four committees contextualises them within the social and political parameters of urban policing in the late 1980s. Each committee is taken as a case study to highlight the following aspects of consultation:- relations between the police and black communities; membership, representation and accountability; responding to community conflict; crime prevention agencies and networks of social control. The findings are then generalised to the sociological theoretical concepts of hegemony, legitimation, community conflict and social control. The central proposition of this thesis is that, whilst these committees are not fulfilling the role Lord Scarman envisaged for them (of involving local community representatives in policing strategies and policies), they do have important policing and political roles. It is argued that they offer a platform from which senior police officers can engage local people into supporting policing objectives without actually involving them in determining those objectives. Furthermore, such committees have political symbolism in that they enable the government to be seen to be responding to the issues of accountability and relations between the police and black communities following the urban disorders, without actually devolving any statutory powers to the community.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A potential low cost novel sensing scheme for monitoring absolute strain is demonstrated. The scheme utilizes a synthetic heterodyne interrogation technique working in conjunction with a linearly chirped, sinusoidally tapered, apodized Bragg grating sensor. The interrogation technique is relatively simple to implement in terms of the required optics and the peripheral electronics. This scheme generates an output signal that has a quasi-linear response to absolute strain with a static strain resolution of ~±20 με and an operating range of ~1000 με.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Initially the study focussed on the factors affecting the ability of the police to solve crimes. An analysts of over twenty thousand police deployments revealed the proportion of time spent investigating crime contrasted to its perceived importance and the time spent on other activities. The fictional portrayal of skills believed important in successful crime investigation were identified and compared to the professional training and 'taught skills’ given to police and detectives. Police practitioners and middle management provided views on the skills needed to solve crimes. The relative importance of the forensic science role. fingerprint examination and interrogation skills were contrasted with changes in police methods resulting from the Police and Criminal Evidence Act and its effect on confessions. The study revealed that existing police systems for investigating crime excluding specifically cases of murder and other serious offences, were unsystematic, uncoordinated, unsupervised and unproductive in using police resources. The study examined relevant and contemporary research in the United States and United Kingdom and with organisational support introduced an experimental system of data capture and initial investigation with features of case screening and management. Preliminary results indicated increases in the collection of essential information and more effective use of investigative resources. In the managerial framework within which this study has been conducted, research has been undertaken in the knowledge elicitation area as a basis for an expert system of crime investigation and the potential organisational benefits of utilising the Lap computer in the first stages of data gathering and investigation. The conclusions demonstrate the need for a totally integrated system of criminal investigation with emphasis on an organisational rather than individual response. In some areas the evidence produced is sufficient to warrant replication, in others additional research is needed to further explore other concepts and proposed systems pioneered by this study.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this thesis the validity of an Assessment Centre (called 'Extended Interview') operated on behalf of the British police is investigated. This Assessment Centre (AC) is used to select from amongst internal candidates (serving policemen and policewomen) and external candidates (graduates) for places on an accelerated promotion scheme. The literature is reviewed with respect to history, content, structure, reliability, validity, efficiency and usefulness of ACs, and to contextual issues surrounding AC use. The history of, background to and content of police Extended Interviews (Els) is described, and research issues are identified. Internal validation involved regression of overall EI grades on measures from component tests, exercises, interviews and peer nominations. Four samples numbering 126, 73, 86 and 109 were used in this part of the research. External validation involved regression of three types of criteria - training grades, rank attained, and supervisory ratings - on all EI measures. Follow-up periods for job criteria ranged from 7 to 19 years. Three samples, numbering 223, 157 and 86, were used in this part of the research. In subsidiary investigations, supervisory ratings were factor analysed and criteria intercorrelated. For two of the samples involved in the external validition, clinical/judgemental prediction was compared with mechanical (unit-weighted composite) prediction. Main conclusions are that: (1) EI selection decisions were valid, but only for a job performance criterion; relatively low validity overall was interpreted principally in terms of the questionable job relatedness of the EI procedure; (2) Els as a whole had more validity than was reflected in final EI decisions; (3) assessors' use of information was not optimum, tending to over-emphasize subjectively derived information particularly from interviews; and (4) mechanical prediction was superior to clinical/judgemental prediction for five major criteria.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We describe how an acousto-optic tunable filter can be used to both demultiplex the signals from multiple fibre Bragg grating sensors and simultaneously provide wide bandwidth signal demodulation in a system using interferometric wavelength shift detection. In an experimental demonstration, the approach provided a noise limited strain resolution of 24.9 n epsilon Hz(-1/ 2) at 15 Hz.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We propose a new method for the simultaneous interrogation of conventional two-beam interferometers and Bragg grating sensors. The technique employs an unbalanced Mach-Zehnder interferometer illuminated by a single low-coherence source, which acts as a wavelength-tunable source for the grating and as a path-matched f ilter for the Fizeau interferometer, thus providing a high phase resolution output for each sensor. The grating sensor demonstrates a dynamic strain resolution of ~0.05 µe/vHz at 20 Hz, while the interferometric phase resolution is better than 1 mrad/vHz at 20 Hz, corresponding to an rms mirror displacement of 0.08 nm.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study investigates the discursive patterns of interactions between police interviewers and women reporting rape in significant witness interviews. Data in the form of video recorded interviews were obtained from a UK police force for the purposes of this study. The data are analysed using a multi-method approach, incorporating tools from micro-sociology, Conversation Analysis and Discursive Psychology, to reveal patterns of interactional control, negotiation, and interpretation. The study adopts a critical approach, which is to say that as well as describing discursive patterns, it explains them in light of the discourse processes involved in the production and consumption of police interview talk, and comments on the relationship between these discourse processes and the social context in which they occur. A central focus of the study is how interviewers draw on particular interactional resources to shape interviewees? accounts in particular ways, and this is discussed in relation to the institutional role of the significant witness interview. The discussion is also extended to the ways in which mainstream rape ideology is both reflected in, and maintained by, the discursive choices of participants. The findings of this study indicate that there are a number of issues to be addressed in terms of the training currently offered to officers at Level 2 of the Professionalising Investigation Programme (PIP) (NPIA, 2009) who intend to conduct significant witness interviews. Furthermore, a need is identified to bring the linguistic and discursive processes of negotiation and transformation identified by the study to the attention of the justice system as a whole. This is a particularly pressing need in light of judicial reluctance to replace written witness statements, the current „end product? of significant witness interviews, with the video recorded interview in place of direct examination in cases of rape.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We report the implementation of a low-cost high-resolution WDM interrogation system operating around 800nm region with bandwidth up to 60 nm and resolution of 13 pm by utilising a tilted fibre Bragg grating as an out-coupling device and a CCD-array detector. The system has been evaluated for interrogating fibre Bragg grating based strain, temperature sensors, giving sensitivities of 0.6 pm/µe and 5.6 pm/°C which are in good agreement with previously reported values. Furthermore, the system has been utilised to detect refractive index change of sample liquids, demonstrating a capability of measuring index change as small as 10-5.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fiber Bragg gratings can be used for monitoring different parameters in a wide variety of materials and constructions. The interrogation of fiber Bragg gratings traditionally consists of an expensive and spacious peak tracking or spectrum analyzing unit which needs to be deployed outside the monitored structure. We present a dynamic low-cost interrogation system for fiber Bragg gratings which can be integrated with the fiber itself, limiting the fragile optical in- and outcoupling interfaces and providing a compact, unobtrusive driving and read-out unit. The reported system is based on an embedded Vertical Cavity Surface Emitting Laser (VCSEL) which is tuned dynamically at 1 kHz and an embedded photodiode. Fiber coupling is provided through a dedicated 45° micromirror yielding a 90° in-the-plane coupling and limiting the total thickness of the fiber coupled optoelectronic package to 550 µm. The red-shift of the VCSEL wavelength is providing a full reconstruction of the spectrum with a range of 2.5 nm. A few-mode fiber with fiber Bragg gratings at 850 nm is used to prove the feasibility of this low-cost and ultra-compact interrogation approach.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Optical fibre strain sensors using Fibre Bragg Gratings (FBGs) are poised to play a major role in structural health monitoring in a variety of application from aerospace to civil engineering. At the heart of technology is the optoelectronic instrumentation required to convert optical signals into measurands. Users are demanding compact, lightweight, rugged and low cost solutions. This paper describes development of a new device based on a blazed FBG and CCD array that can potentially meet the above demands. We have shown that this very low cost technique may be used to interrogate a WDM array of sensor gratings with highly accurate and highly repeatable results unaffected by the polarisation state of the radiation. In this paper, we present results showing that sensors may be interrogated with an RMS error of 1.7pm, drift below 0.12pm and dynamic range of up to 65nm.