950 resultados para plasmon resonance absorption


Relevância:

20.00% 20.00%

Publicador:

Resumo:

AIMS: Although the coronary artery vessel wall can be imaged non-invasively using magnetic resonance imaging (MRI), the in vivo reproducibility of wall thickness measures has not been previously investigated. Using a refined magnetization preparation scheme, we sought to assess the reproducibility of three-dimensional (3D) free-breathing black-blood coronary MRI in vivo. METHODS AND RESULTS: MRI vessel wall scans parallel to the right coronary artery (RCA) were obtained in 18 healthy individuals (age range 25-43, six women), with no known history of coronary artery disease, using a 3D dual-inversion navigator-gated black-blood spiral imaging sequence. Vessel wall scans were repeated 1 month later in eight subjects. The visible vessel wall segment and the wall thickness were quantitatively assessed using a semi-automatic tool and the intra-observer, inter-observer, and inter-scan reproducibilities were determined. The average imaged length of the RCA vessel wall was 44.5+/-7 mm. The average wall thickness was 1.6+/-0.2 mm. There was a highly significant intra-observer (r=0.97), inter-observer (r=0.94), and inter-scan (r=0.90) correlation for wall thickness (all P<0.001). There was also a significant agreement for intra-observer, inter-observer, and inter-scan measurements on Bland-Altman analysis. The intra-class correlation coefficients for intra-observer (r=0.97), inter-observer (r=0.92), and inter-scan (r=0.86) analyses were also excellent. CONCLUSION: The use of black-blood free-breathing 3D MRI in conjunction with semi-automated analysis software allows for reproducible measurements of right coronary arterial vessel-wall thickness. This technique may be well-suited for non-invasive longitudinal studies of coronary atherosclerosis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purpose of this study was to evaluate a free-breathing three-dimensional (3D) dual inversion-recovery (DIR) segmented k-space gradient-echo (turbo field echo [TFE]) imaging sequence at 3T for the quantification of aortic vessel wall dimensions. The effect of respiratory motion suppression on image quality was tested. Furthermore, the reproducibility of the aortic vessel wall measurements was investigated. Seven healthy subjects underwent 3D DIR TFE imaging of the aortic vessel wall with and without respiratory navigator. Subsequently, this sequence with respiratory navigator was performed twice in 10 healthy subjects to test its reproducibility. The signal-to-noise (SNR), contrast-to-noise ratio (CNR), vessel wall sharpness, and vessel wall volume (VWV) were assessed. Data were compared using the paired t-test, and the reproducibility of VWV measurements was evaluated using intraclass correlation coefficients (ICCs). SNR, CNR, and vessel wall sharpness were superior in scans performed with respiratory navigator compared to scans performed without. The ICCs concerning intraobserver, interobserver, and interscan reproducibility were excellent (0.99, 0.94, and 0.95, respectively). In conclusion, respiratory motion suppression substantially improves image quality of 3D DIR TFE imaging of the aortic vessel wall at 3T. Furthermore, this optimized technique with respiratory motion suppression enables assessment of aortic vessel wall dimensions with high reproducibility.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Previously reported results on deep level optical spectroscopy, optical absorption, deep level transient spectroscopy, photoluminescence excitation, and time resolved photoluminescence are reviewed and discussed in order to know which are the mechanisms involved in electron capture and emission of the Ti acceptor level in GaP. First, the analysis indicates that the 3T1(F) crystal¿field excited state is not in resonance with the conduction band states. Second, it is shown that both the 3T2 and 3T1(F) excited states do not play any significant role in the process of electron emission and capture.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: To compare multidetector-row computed tomographic (MDCT) enterography with magnetic resonance (MR) enterography performed upon acute exacerbation of Crohn's disease. Subjects and Methods: Fifty-seven patients (mean age 33.5) with proven Crohn's disease and symptoms suggesting acute exacerbation were prospectively included. After oral administration of 1-2 liters of 5% methylcellulose, MDCT and MR enterography were performed on each patient (mean delay <24 h). Three radiologists blindly and independently evaluated each examination for technical quality and in terms of 8 pathological features of Crohn's disease. Observers' agreement, sensitivity and specificity resulted from comparison with the reference standard [surgery (n = 24), endoscopy (n = 17) and long-term follow-up (n = 16)]. Results: MDCT enterography demonstrated fewer artifacts than MR enterography (p < 0.0001). In 48 MDCT/MR enterography examinations, active disease was demonstrated: abscesses (n = 11), fistulas (n = 13), stenoses (n = 23) and/or intestinal inflammation (n = 38). Observers' agreement (range 0.56-0.87) was not significantly different between MDCT and MR enterography, neither in terms of sensitivity (range 58-95%) nor specificity (range 67-100%) for each of the 8 pathological features. Conclusion: Statistically, MR enterography is of similar diagnostic value as MDCT enterography for acute complications of Crohn's disease. Since the typical Crohn's disease patient is young and will very likely undergo life-long imaging, and given concerns about radiation exposure with MDCT, MR enterography should be the preferred modality.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Optical absorption spectra and transmission electron microscopy (TEM) observations on InGaAs/InP layers under compressive strain are reported. From the band¿gap energy dispersion, the magnitude of the strain inhomogeneities. Is quantified and its microscopic origin is analyzed in view of the layer microstructure. TEM observations reveal a dislocation network at the layer interface the density of which correlates with ¿¿. It is concluded that local variations of dislocation density are responsible for the inhomogeneous strain field together with another mechanism that dominates when the dislocation density is very low.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Report of one case of bilateral cryptorchism with non-palpable testes in a 26-year old patient with progressive muscle dystrophy. Physical examination and ultrasound study to detect the testicular location were inconclusive. An analysis is made of data obtained with the NMR study as well as a review of the advantages and contributions from this new technique in the location and characterization of undescended testes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We have analyzed the effects of the addition of external noise to nondynamical systems displaying intrinsic noise, and established general conditions under which stochastic resonance appears. The criterion we have found may be applied to a wide class of nondynamical systems, covering situations of different nature. Some particular examples are discussed in detail.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Non-invasive visualization of the coronary arteries represents a major challenge in modern cardiology, but this goal may be achieved in the near future by MR angiography. Possible applications are non-invasive diagnosis of coronary artery disease, and follow-up examinations for therapy control after PTCA, in order to detect restenosis at an early stage. A multiple slice technique (2 mm slice thickness, with a spatial resolution of 1 x 1 mm, Philips Gyroscan ACS-II, 1.5 Tesla) was used. Ten volunteers were imaged and 10 patients with coronary artery disease were examined before and after PTCA. MR measurements were validated by quantitative coronary angiography. The diameters of the proximal coronary arteries as measured by both methods were compared, and a good correlation was found (r = 0.76). Thus, it is concluded that non-invasive visualization of the coronary arteries is possible before and after PTCA and allows to determine potential restenoses. However, patient cooperation is essential for good image quality. Moreover, limited spatial image resolution and breathing artifacts restrict MR coronary angiography today to be used as a routine diagnostic tool for the diagnosis of coronary artery disease.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aims Perfusion-cardiac magnetic resonance (CMR) has emerged as a potential alternative to single-photon emission computed tomography (SPECT) to assess myocardial ischaemia non-invasively. The goal was to compare the diagnostic performance of perfusion-CMR and SPECT for the detection of coronary artery disease (CAD) using conventional X-ray coronary angiography (CXA) as the reference standard. Methods and results In this multivendor trial, 533 patients, eligible for CXA or SPECT, were enrolled in 33 centres (USA and Europe) with 515 patients receiving MR contrast medium. Single-photon emission computed tomography and CXA were performed within 4 weeks before or after CMR in all patients. The prevalence of CAD in the sample was 49%. Drop-out rates for CMR and SPECT were 5.6 and 3.7%, respectively (P = 0.21). The primary endpoint was non-inferiority of CMR vs. SPECT for both sensitivity and specificity for the detection of CAD. Readers were blinded vs. clinical data, CXA, and imaging results. As a secondary endpoint, the safety profile of the CMR examination was evaluated. For CMR and SPECT, the sensitivity scores were 0.67 and 0.59, respectively, with the lower confidence level for the difference of +0.02, indicating superiority of CMR over SPECT. The specificity scores for CMR and SPECT were 0.61 and 0.72, respectively (lower confidence level for the difference: -0.17), indicating inferiority of CMR vs. SPECT. No severe adverse events occurred in the 515 patients. Conclusion In this large multicentre, multivendor study, the sensitivity of perfusion-CMR to detect CAD was superior to SPECT, while its specificity was inferior to SPECT. Cardiac magnetic resonance is a safe alternative to SPECT to detect perfusion deficits in CAD.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Using an extended-random-phase-approximation sum-rule technique, we have investigated the bulk-plasmon dispersion relation, incorporating in a simple way exchange and correlation effects within the jellium model. The results obtained are compared with recent experimental findings. The key role played by exchange and correlation effects in improving the agreement between theory and experiment is stressed. The static polarizability has also been calculated as a function of q. The formulas can be easily modified to incorporate band-structure effects (through an intraband electron effective mass) and core-polarization effects (through a static dielectric constant).