887 resultados para physician-assisted dying


Relevância:

20.00% 20.00%

Publicador:

Resumo:

STUDY DESIGN: A prospective case control study design was conducted. OBJECTIVES: The purpose of the current study was to determine the intraoperative radiation hazard to spine surgeons by occupational radiation exposure during percutaneous vertebroplasty and possible consequences with respect to radiation protection. SUMMARY OF BACKGROUND DATA: The development of minimally invasive surgery techniques has led to an increasing number of fluoroscopically guided procedures being done percutaneously such as vertebroplasty, which is the percutaneous cement augmentation of vertebral bodies. METHODS: Three months of occupational dose data for two spine surgeons was evaluated measuring the radiation doses to the thyroid gland, the upper extremities, and the eyes during vertebroplasty. RESULTS: The annual risk of developing a fatal cancer of the thyroid is 0.0025%, which means a very small to small risk. The annual morbidity (the risk of developing a cancer including nonfatal ones) is 0.025%, which already means a small to medium risk. The dose for the eye lens was about 8% of the threshold dose to develop a radiation induced cataract (150 mSv); therefore, the risk is very low but not negligible. The doses measured for the skin are 10% of the annual effective dose limit (500 mSv) recommended by the ICRP (International Commission on Radiologic Protection); therefore, the annual risk for developing a fatal skin cancer is very low. CONCLUSION: While performing percutaneous vertebroplasty, the surgeon is exposed to a significant amount of radiation. Proper surgical technique and shielding devices to decrease potentially high morbidity are mandatory. Training in radiation protection should be an integral part of the education for all surgeons using minimally invasive radiologic-guided interventional techniques.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Surgical navigation systems visualize the positions and orientations of surgical instruments and implants as graphical overlays onto a medical image of the operated anatomy on a computer monitor. The orthopaedic surgical navigation systems could be categorized according to the image modalities that are used for the visualization of surgical action. In the so-called CT-based systems or 'surgeon-defined anatomy' based systems, where a 3D volume or surface representation of the operated anatomy could be constructed from the preoperatively acquired tomographic data or through intraoperatively digitized anatomy landmarks, a photorealistic rendering of the surgical action has been identified to greatly improve usability of these navigation systems. However, this may not hold true when the virtual representation of surgical instruments and implants is superimposed onto 2D projection images in a fluoroscopy-based navigation system due to the so-called image occlusion problem. Image occlusion occurs when the field of view of the fluoroscopic image is occupied by the virtual representation of surgical implants or instruments. In these situations, the surgeon may miss part of the image details, even if transparency and/or wire-frame rendering is used. In this paper, we propose to use non-photorealistic rendering to overcome this difficulty. Laboratory testing results on foamed plastic bones during various computer-assisted fluoroscopybased surgical procedures including total hip arthroplasty and long bone fracture reduction and osteosynthesis are shown.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A novel computer-assisted injection device for the delivery of highly viscous bone cements in vertebroplasty is presented. It addresses the shortcomings of manual injection systems ranging from low-pressure and poor level of control to device failure. The presented instrument is capable of generating a maximum pressure of 5000 kPa in traditional 6-ml syringes and provides an advanced control interface for precise cement delivery from outside radiation fields emitted by intraoperative imaging systems. The integrated real-time monitoring of injection parameters, such as flow-rate, volume, pressure, and viscosity, simplifies consistent documentation of interventions and establishes a basis for the identification of safe injection protocols on the longer term. Control algorithms prevent device failure due to overloading and provide means to immediately stop cement flow to avoid leakage into adjacent tissues.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background The study is part of a nationwide evaluation of complementary and alternative medicine (CAM) in primary care in Switzerland. The Objective was to identify patients' expectations and reasons governing the choice of complementary medicine compared with conventional primary care (CONV). Methods The data were derived from the PEK study (Programm Evaluation Komplementärmedizin), which was conducted in 2002–2003 with 7879 adult patients and parents of 1291 underage patients, seeking either complementary (CAM) or conventional (CONV) primary care. The study was performed as a cross-sectional survey. The respondents were asked to document their (or their children's) self-perceived health status, reasons governing their choice, and treatment expectations. Physicians were practicing conventional medicine and/or complementary methods (homeopathy, anthroposophic medicine, neural therapy, and traditional Chinese medicine). Reasons governing the choice of physician were evaluated on the basis of a three-part classification (physician-related, procedure-related, and pragmatic/other reasons) Results and Discussion Patients seeing CAM physicians tend to be younger and more often female. CAM patients referred to procedure-related reasons more frequently, whereas pragmatic reasons dominated among CONV patients. CAM respondents expected fewer adverse side effects compared to conventional care patients. Conclusion The majority of alternative medicine users appear to have chosen CAM mainly because they wish to undergo a certain procedure; additional reasons include desire for more comprehensive treatment, and expectation of fewer side-effects.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND AND PURPOSE: Computer-assisted navigation is increasingly used in functional endoscopic sinus surgery (FESS) to prevent injury to vital structures, necessitating preparative CT and, thus, radiation exposure. The purpose of our study was to investigate currently used radiation doses for CT in computer-assisted navigation in sinus surgery (CAS-CT) and to assess minimal doses required. MATERIALS AND METHODS: A questionnaire inquiring about dose parameters used for CAS-CT was sent to 30 radiologic institutions. The feasibility of low-dose registration was tested with a phantom. The influence of CAS-CT dose on technical accuracy and on the practical performance of 5 ear, nose, and throat (ENT) surgeons was evaluated with cadaver heads. RESULTS: The questionnaire response rate was 63%. Variation between minimal and maximal dose used for CAS-CT was 18-fold. Phantom registration was possible with doses as low as 1.1 mGy. No dose dependence on technical accuracy was found. ENT surgeons were able to identify anatomic landmarks on scans with a dose as low as 3.1 mGy. CONCLUSIONS: The vast dose difference between institutions mirrors different attitudes toward image quality and radiation-protection issues rather than being technically founded, and many patients undergo CAS-CT at higher doses than necessary. The only limit for dose reduction in CT for computer-assisted endoscopic sinus surgery is the ENT surgeon's ability to cope with impaired image quality, whereas there is no technically justified lower dose limit. We recommend, generally, doses used for the typical diagnostic low-dose sinus CT (120 kV/20-50 mAs). When no diagnostic image quality is needed, even a reduction down to a third is possible.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In daily medicine we often see patients complaining about thoracic pain. There is little doubt about the etiology in the most cases, but several patients continue posing diagnostic problems. There are different pathophysiological views to understand the situation of those patients, and it is important to determine their mental and psychological conditions. For this purpose, the focus on transference and countertransference phenomena has to be stressed. With these elements it will be possible to determine the diagnostic and therapeutic approach to those patients to reassure them and to justify investigations.