967 resultados para peak separation
Resumo:
We propose a frequency domain adaptive algorithm for
wave separation in wind instruments. Forward and backward travelling waves are obtained from the signals acquired by two microphones placed along the tube, while the
separation ?lter is adapted from the information given by a
third microphone. Working in the frequency domain has a
series of advantages, among which are the ease of design of
the propagation ?lter and its differentiation with respect to
its parameters.
Although the adaptive algorithm was developed as a ?rst
step for the estimation of playing parameters in wind instruments it can also be used, without any modi?cations, for
other applications such as in-air direction of arrival (DOA)
estimation. Preliminary results on these applications will
also be presented.
Resumo:
An evaluation of the genetic diversity within Fasciola hepatica (liver fluke) may provide an insight into its potential to respond to environmental changes, such as anthelmintic use or climate change. In this study, we determined the mitochondrial DNA haplotypes of >400 flukes from 29 individual cattle, from 2 farms in the Netherlands, as an exemplar of fasciolosis in a European context. Analysis of this dataset has provided us with a measure of the genetic variation within infrapopulations (individual hosts) and the diversity between infrapopulations within a herd of cattle. Temporal sampling from one farm allowed for the measurement of the stability of genetic variation at a single location, whilst the comparison between the two farms provided information on the variation in relation to distance and previous anthelmintic regimes. We showed that the liver fluke population in this region is predominantly linked to 2 distinct clades. Individual infrapopulations contain a leptokurtic distribution of genetically diverse flukes. The haplotypes present on a farm have been shown to change significantly over a relatively short time-period.
Resumo:
The ionic liquid 1-ethyl-3-methylimidazolium bis{(trifluoromethyl)sulfonyl}amide ([C(2)mim][NTf2]) was tested as solvent for the separation of aromatic and aliphatic hydrocarbons containing 7 or 8 carbon atoms (the C-7- and C-8-fractions). The liquid-liquid equilibria (LLE) of the ternary systems (heptane + toluene + [C(2)mim][NTf2]) and (octane + ethylbenzene + [C(2)mim][NTf2]), at 25 degrees C, were experimentally determined. The performance of the ionic liquid as the solvent in such systems was evaluated by means of the calculation of the solute distribution ratio and the selectivity. The results were compared to those previously reported for the extraction of benzene from its mixtures with hexane by using the same ionic liquid, therefore analysing the influence of the size of the hydrocarbons. It was found that the ionic liquid is also good for the extraction of C-7- and C-8- fraction aromatic compounds, just a greater amount of ionic liquid being needed to perform an equivalently efficient separation than for the C-6-fraction. It is also discussed how [C(2)mim][NTf2] performs comparably better than the conventional solvent sulfolane. The original 'Non-Random Two-Liquid' (NRTL) equation was used to adequately correlate the experimental LLE data.
Resumo:
This study describes the development and optimization of an immunomagnetic separation (IMS) method to isolate Mycobacterium bovis cells from lymph node tissues. Gamma-irradiated whole M. bovis AF2122/97 cells and ethanol-extracted surface antigens of such cells were used to produce M. bovis-speci?c polyclonal and monoclonal antibodies in rabbits and mice. They were also used to generate M. bovis-speci?c peptide ligands by phage display biopanning. The various antibodies and peptide ligands obtained were used to coat MyOne tosyl-activated Dynabeads (Life Technologies), singly or in combination, and evaluated for IMS. Initially, M. bovis capture from Middlebrook 7H9 broth suspensions (concentration range, 10 to 105 CFU/ml) was evaluated by IMS combined with an M. bovis-speci?c touchdown PCR. IMS-PCR results and, subsequently, IMS-culture results indicated that the beads with greatest immunocapture capability for M. bovis in broth were those coated simultaneously with a monoclonal antibody and a biotinylated 12-mer peptide. These dually coated beads exhibited minimal capture (mean of 0.36% recovery) of 12 other Mycobacterium spp. occasionally encountered in veterinary tuberculosis (TB) diagnostic laboratories. When the optimized IMS method was applied to various M. bovis-spiked lymph node matrices, it demonstrated excellent detection sensitivities (50% limits of detection of 3.16 and 57.7 CFU/ml of lymph node tissue homogenate for IMS-PCR and IMS-culture, respectively). The optimized IMS method therefore has the potential to improve isolation of M. bovis from lymph nodes and hence the diagnosis of bovine tuberculosis.
Resumo:
High cadence, multiwavelength, optical observations of a solar active region, obtained with the Swedish Solar Telescope, are presented. Two magnetic bright points are seen to separate in opposite directions at a constant velocity of 2.8 km s(-1). After a separation distance of approximate to 4400 km is reached, multiple Ellerman bombs are observed in both Ha and Ca-K images. As a result of the Ellerman bombs, periodic velocity perturbations in the vicinity of the magnetic neutral line, derived from simultaneous Michelson Doppler Imager data, are generated with amplitude +/-6 km s(-1) and wavelength approximate to 1000 km. The velocity oscillations are followed by an impulsive brightening visible in Ha and Ca-K, with a peak intensity enhancement of 63%. We interpret these velocity perturbations as the magnetic field deformation necessary to trigger forced reconnection. A time delay of approximate to 3 minutes between the Ha-wing and Ca-K observations indicates that the observed magnetic reconnection occurs at a height of similar to 200 km above the solar surface. These observations are consistent with theoretical predictions and provide the first observational evidence of microflare activity driven by forced magnetic reconnection.
Resumo:
This paper studies single-channel speech separation, assuming unknown, arbitrary temporal dynamics for the speech signals to be separated. A data-driven approach is described, which matches each mixed speech segment against a composite training segment to separate the underlying clean speech segments. To advance the separation accuracy, the new approach seeks and separates the longest mixed speech segments with matching composite training segments. Lengthening the mixed speech segments to match reduces the uncertainty of the constituent training segments, and hence the error of separation. For convenience, we call the new approach Composition of Longest Segments, or CLOSE. The CLOSE method includes a data-driven approach to model long-range temporal dynamics of speech signals, and a statistical approach to identify the longest mixed speech segments with matching composite training segments. Experiments are conducted on the Wall Street Journal database, for separating mixtures of two simultaneous large-vocabulary speech utterances spoken by two different speakers. The results are evaluated using various objective and subjective measures, including the challenge of large-vocabulary continuous speech recognition. It is shown that the new separation approach leads to significant improvement in all these measures.
Resumo:
The effect of non-uniform target illumination on the soft X-ray lasing output intensity of the J=2-1 Ne-like Ge transitions as a function of length was investigated. As the degree of nonunifonnity increased with length the Ne-like Ge 23.2 and 23.6 nm J=2-1 transitions did not show exponentiation of output intensity. Using an experimentally measured gain-intensity scaling relationship these results were modelled and good qualitative agreement obtained. The model indicates that for Ge targets which are non-uniformly illuminated, even with peak to valley ratios of up to 3 efficient operation can be achieved at between 2-3x threshold intensity. Further studies of the effect of increasing the separation between the two targets of a double target geometry are also presented.