1000 resultados para patient perspektiv
Resumo:
Exophthalmos is the main symptom revealing orbital masses. This sign needs to be imaged mainly by MRI and/or CT. As Graves disease is the main etiology of exophthalmos, CT scan should be performed as the initial imaging modality. Indications for US and Doppler are mostly limited to the study of ocular masses, and eventually may help the characterization of extra-ocular lesions. In all cases, imaging is useful to characterize: the precise location of the lesion which can be the intra-conal space (including muscles), the extra-conal space (associated or not to an extra-orbital lesion), or the eyeball; the features of the lesion (density, signal, enhancement.). These findings are used to generate a differential diagnosis. Imaging is also useful to precise the extension of the mass, and in some cases to select the appropriate surgical approach, and for follow-up.
Resumo:
Little is known about the long-term survivors of acute arsenic intoxication. We present here a clinical case report of a man with chronic hepatitis B virus (HBV) infection who developed hepatocellular carcinoma four years after acute arsenic poisoning. HBsAg was detected in serum in 1990 when he voluntarily donated blood. In 1991, the patient suffered from severe psychological depression that led him to attempt suicide by massive ingestion of an arsenic-containing rodenticide. He survived with polyneuropathy and paralysis of the lower limbs, and has been wheelchair-bound since then. During participation in a follow-up study conducted among HBV carriers, abdominal ultrasound detected a two-centimeter liver mass consistent with hepatocellular carcinoma. The tumor was confirmed by computed tomography (CT) and magnetic resonance image (MRI). Because of his significant comorbidity, the patient received palliative treatment with transarterial lipiodol chemoembolization (TACE) on three occasions (1996, 1997 and 1999). At his most recent visit in May 2005, the patient was asymptomatic, liver enzymes were normal and the tumor was in remission on ultrasound.
Resumo:
PURPOSE: EOS (EOS imaging S.A, Paris, France) is an x-ray imaging system that uses slot-scanning technology in order to optimize the trade-off between image quality and dose. The goal of this study was to characterize the EOS system in terms of occupational exposure, organ doses to patients as well as image quality for full spine examinations. METHODS: Occupational exposure was determined by measuring the ambient dose equivalents in the radiological room during a standard full spine examination. The patient dosimetry was performed using anthropomorphic phantoms representing an adolescent and a five-year-old child. The organ doses were measured with thermoluminescent detectors and then used to calculate effective doses. Patient exposure with EOS was then compared to dose levels reported for conventional radiological systems. Image quality was assessed in terms of spatial resolution and different noise contributions to evaluate the detector's performances of the system. The spatial-frequency signal transfer efficiency of the imaging system was quantified by the detective quantum efficiency (DQE). RESULTS: The use of a protective apron when the medical staff or parents have to stand near to the cubicle in the radiological room is recommended. The estimated effective dose to patients undergoing a full spine examination with the EOS system was 290μSv for an adult and 200 μSv for a child. MTF and NPS are nonisotropic, with higher values in the scanning direction; they are in addition energy-dependent, but scanning speed independent. The system was shown to be quantum-limited, with a maximum DQE of 13%. The relevance of the DQE for slot-scanning system has been addressed. CONCLUSIONS: As a summary, the estimated effective dose was 290μSv for an adult; the image quality remains comparable to conventional systems.
Resumo:
Diagnostic reference levels (DRLs) were established for 21 indication-based CT examinations for adults in Switzerland. One hundred and seventy-nine of 225 computed tomography (CT) scanners operated in hospitals and private radiology institutes were audited on-site and patient doses were collected. For each CT scanner, a correction factor was calculated expressing the deviation of the measured weighted computed tomography dose index (CTDI) to the nominal weighted CTDI as displayed on the workstation. Patient doses were corrected by this factor providing a realistic basis for establishing national DRLs. Results showed large variations in doses between different radiology departments in Switzerland, especially for examinations of the petrous bone, pelvis, lower limbs and heart. This indicates that the concept of DRLs has not yet been correctly applied for CT examinations in clinical routine. A close collaboration of all stakeholders is mandatory to assure an effective radiation protection of patients. On-site audits will be intensified to further establish the concept of DRLs in Switzerland.
Resumo:
The traditional obesity treatments have proven to be ineffective in the long-term. The presence of eating disorders frequently explains this phenomena. Eating educational and behavioral aspects must be addressed in a practical way so that patients could gradually become aware of their behavior towards food as well as internal sensations associated with hunger, satiety, craving and pleasure. Finally, the link between emotions and compulsive eating behaviors during and between meals is an essential aspect that the general practitioner can help the patient to understand. A specialized psychological treatment can then be considered when the patient shows sufficient motivation and consciousness.
Resumo:
We report the case of an inaugural episode of generalized seizures in a 40-year-old male with a history of chronic kidney disease associated with TSC2-PKD1 contiguous gene syndrome. This patient was under prophylactic treatment of phenytoin since 2 years because of a subarachnoid hemorrhage due to a ruptured cerebral aneurysm. Laboratory results revealed therapeutic range of phenytoin levels, but severe hypocalcemia associated with profound vitamin D deficiency that could not be explained by secondary hyperparathyroidism alone. The interaction of phenytoin on the P-450 cytochromes activity has been demonstrated to accelerate the rate of 25-hydroxivitamin D3 and 1α,25-dihydroxivitamin D3 catabolism into inactive metabolites, leading to hypocalcemia. Physicians should be aware of significant phenytoin interactions on vitamin D metabolism which may lead to symptomatic hypocalcemia in patients with chronic kidney disease.
Resumo:
Hand hygiene compliance of patients receiving hemodialysis treatment is a contemporary discussion topic among health care professionals in the Nephrology Clinic of Helsinki University City Hospital. The purpose of the Final Thesis is to review patient hand hygiene in terms of risks its lack entails and based on the evidence based findings to design an end product as a poster. The poster can be utilised in the Nephrology Clinic's nursing environment to educate and motivate patients to pay specifid attention to the importance of hand hygiene. The method used was a systematic literature review. The most important evidence based findings were extracted from the chosen thirteen scientific articles. All articles were searched from the Cumulative Index to Nursing and Allied Health Literature electronic database. The gathered information was then used to build the content of a patient education tool that for this project was defined as a Poster. The findings in this study showed that transmission of bloodborne infections, like Hepatitis B or C virus can occur through a vascular access and that the consequences of this can be very fatal. Additionally, environmental surfaces such as furniture, door knobs and dialysis machine control knobs were all possible infection sources for the patient receiving hemodialysis treatment. Adherence to good hand hygiene behaviour lowered the risk for infections. The end product of this study is a poster that is targeted to patients undergoing hemodialysis treatment. Using a health promotion agenda in the Poster, it is hoped that patients will pay more attention to the importance of hand hygiene and that they will be more motivated to use aseptic methods such as alcohol based hand rubs in the hemodialysis setting.