727 resultados para indonesia


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Palaeodata in synthesis form are needed as benchmarks for the Palaeoclimate Modelling Intercomparison Project (PMIP). Advances since the last synthesis of terrestrial palaeodata from the last glacial maximum (LGM) call for a new evaluation, especially of data from the tropics. Here pollen, plant-macrofossil, lake-level, noble gas (from groundwater) and δ18O (from speleothems) data are compiled for 18±2 ka (14C), 32 °N–33 °S. The reliability of the data was evaluated using explicit criteria and some types of data were re-analysed using consistent methods in order to derive a set of mutually consistent palaeoclimate estimates of mean temperature of the coldest month (MTCO), mean annual temperature (MAT), plant available moisture (PAM) and runoff (P-E). Cold-month temperature (MAT) anomalies from plant data range from −1 to −2 K near sea level in Indonesia and the S Pacific, through −6 to −8 K at many high-elevation sites to −8 to −15 K in S China and the SE USA. MAT anomalies from groundwater or speleothems seem more uniform (−4 to −6 K), but the data are as yet sparse; a clear divergence between MAT and cold-month estimates from the same region is seen only in the SE USA, where cold-air advection is expected to have enhanced cooling in winter. Regression of all cold-month anomalies against site elevation yielded an estimated average cooling of −2.5 to −3 K at modern sea level, increasing to ≈−6 K by 3000 m. However, Neotropical sites showed larger than the average sea-level cooling (−5 to −6 K) and a non-significant elevation effect, whereas W and S Pacific sites showed much less sea-level cooling (−1 K) and a stronger elevation effect. These findings support the inference that tropical sea-surface temperatures (SSTs) were lower than the CLIMAP estimates, but they limit the plausible average tropical sea-surface cooling, and they support the existence of CLIMAP-like geographic patterns in SST anomalies. Trends of PAM and lake levels indicate wet LGM conditions in the W USA, and at the highest elevations, with generally dry conditions elsewhere. These results suggest a colder-than-present ocean surface producing a weaker hydrological cycle, more arid continents, and arguably steeper-than-present terrestrial lapse rates. Such linkages are supported by recent observations on freezing-level height and tropical SSTs; moreover, simulations of “greenhouse” and LGM climates point to several possible feedback processes by which low-level temperature anomalies might be amplified aloft.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fire activity has varied globally and continuously since the last glacial maximum (LGM) in response to long-term changes in global climate and shorter-term regional changes in climate, vegetation, and human land use. We have synthesized sedimentary charcoal records of biomass burning since the LGM and present global maps showing changes in fire activity for time slices during the past 21,000 years (as differences in charcoal accumulation values compared to pre-industrial). There is strong broad-scale coherence in fire activity after the LGM, but spatial heterogeneity in the signals increases thereafter. In North America, Europe and southern South America, charcoal records indicate less-than-present fire activity during the deglacial period, from 21,000 to ∼11,000 cal yr BP. In contrast, the tropical latitudes of South America and Africa show greater-than-present fire activity from ∼19,000 to ∼17,000 cal yr BP and most sites from Indochina and Australia show greater-than-present fire activity from 16,000 to ∼13,000 cal yr BP. Many sites indicate greater-than-present or near-present activity during the Holocene with the exception of eastern North America and eastern Asia from 8,000 to ∼3,000 cal yr BP, Indonesia and Australia from 11,000 to 4,000 cal yr BP, and southern South America from 6,000 to 3,000 cal yr BP where fire activity was less than present. Regional coherence in the patterns of change in fire activity was evident throughout the post-glacial period. These complex patterns can largely be explained in terms of large-scale climate controls modulated by local changes in vegetation and fuel load

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This work has investigated the impact of three different low-frequency sea surface temperature (SST) variability modes located in the Indian and the Pacific Oceans on the interannual variability of the South American Monsoon System (SAMS) using observed and numerical data. Rotated Empirical Orthogonal Function (REOF) analysis and numerical simulations with a General Circulation Model (GCM) were used. One of the three SST variability modes is located close to southeastern Africa. According to the composites, warmer waters over this region are associated with enhanced austral summer precipitation over the sub-tropics. The GCM is able to reproduce this anomalous precipitation pattern, simulating a wave train emanating from the Indian Ocean towards South America (SA). A second SST variability mode was located in the western Pacific Ocean. REOF analysis indicates that warmer waters are associated with drought conditions over the South Atlantic Convergence Zone (SACZ) and enhanced precipitation over the sub-tropics. The GCM indicates that the warmer waters over Indonesia generate drought conditions over tropical SA through a Pacific South America-like (PSA) wave pattern emanating from the western Pacific. Finally, the third SST variability mode is located over the southwestern South Pacific. The composites indicate that warmer waters are associated with enhanced precipitation over the SACZ and drought conditions over the sub-tropics. There is a PSA-like wave train emanating from Indonesia towards SA, and another crossing the Southern Hemisphere in the extra-tropics, probably associated with transient activity. The GCM is able to reproduce the anomalous precipitation pattern, although it is weaker than observed. The PSA-like pattern is simulated, but the model fails in reproducing the extra-tropical wave activity.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In this study, we revisited the phylogeography of the three of major DENV-3 genotypes and estimated its rate of evolution, based on the analysis of the envelope (E) gene of 200 strains isolated from 31 different countries around the world over a time period of 50 years (1956-2006). Our phylogenetic analysis revealed a geographical subdivision of DENV-3 population in several country-specific clades. Migration patterns of the main DENV-3 genotypes showed that genotype I was mainly circumspect to the maritime portion of Southeast-Asia and South Pacific, genotype 11 stayed within continental areas in South-East Asia, while genotype III spread across Asia, East Africa and into the Americas. No evidence for rampant co-circulation of distinct genotypes in a single locality was found, suggesting that some factors, other than geographic proximity, may limit the continual dispersion and reintroduction of new DENV-3 variants. Estimates of the evolutionary rate revealed no significant differences among major DENV-3 genotypes. The mean evolutionary rate of DENV-3 in areas with long-term endemic transmissions (i.e., Indonesia and Thailand) was similar to that observed in the Americas, which have been experiencing a more recent dengue spread. We estimated the origin of DENV-3 virus around 1890, and the emergence of current diversity of main DENV-3 genotypes between the middle 1960s and the middle 1970s, coinciding with human population growth, urbanization, and massive human movement, and with the description of the first cases of DENV-3 hemorrhagic fever in Asia. (C) 2008 Elsevier B.V. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Merozoite surface proteins (MSPs) of the malaria parasites are major candidates for vaccine development targeting asexual blood stages. However, the diverse antigenic repertoire of these antigens that induce strain-specific protective immunity in human is a major challenge for vaccine design and often determines the efficacy of a vaccine. Here we further assessed the genetic diversity of Plasmodium vivax MSP4 (PvMSP4) protein using 195 parasite samples collected mostly from Thailand, Indonesia and Brazil. Overall, PvMSP4 is highly conserved with only eight amino acid substitutions. The majority of the haplotype diversity was restricted to the two short tetrapeptide repeat arrays in exon 1 and 2, respectively. Selection and neutrality tests indicated that exon 1 and the entire coding region of PvMSP4 were under purifying selection. Despite the limited nucleotide polymorphism of PvMSP4, significant genetic differentiation among the three major parasite populations was detected. Moreover, microgeographical heterogeneity was also evident in the parasite populations from different endemic areas of Thailand. (C) 2009 Elsevier B.V. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This thesis focuses on using photovoltaic produced electricity to power air conditioners in a tropical climate. The study takes place in Surabaya, Indonesia at two different locations the classroom, located at the UBAYA campus and the home office, 10 km away. Indonesia has an average solar irradiation of about 4.8 kWh/m²/day (PWC Indonesia, 2013) which is for ideal conditions for these tests. At the home office, tests were conducted on different photovoltaic systems. A series of measuring devices recorded the performance of the 800 W PV system and the consumption of the 1.35 kW air conditioner (cooling capacity). To have an off grid system many of the components need to be oversized. The inverter has to be oversized to meet the startup load of the air conditioner, which can be 3 to 8 times the operating power (Rozenblat, 2013). High energy consumption of the air conditioner would require a large battery storage to provide one day of autonomy. The PV systems output must at least match the consumption of the air conditioner. A grid connect system provides a much better solution with the 800 W PV system providing 80 % of the 3.5 kWh load of the air conditioner, the other 20 % coming from the grid during periods of low irradiation. In this system the startup load is provided by the grid so the inverter does not need to be oversized. With the grid-connected system, the PV panel’s production does not need to match the consumption of the air conditioner, although a smaller PV array will mean a smaller percentage of the load will be covered by PV. Using the results from the home office tests and results from measurements made in the classroom. Two different PV systems (8 kW and 12 kW) were simulated to power both the current air conditioners (COP 2.78) and new air conditioners (COP 4.0). The payback period of the systems can vary greatly depending on if a feed in tariff is awarded or not. If the feed in tariff is awarded the best system is the 12 kW system, with a payback period of 4.3 years and a levelized cost of energy at -3,334 IDR/kWh. If the feed in tariff is not granted then the 8 kW system is the best choice with a lower payback period and lower levelized cost of energy than the 12 kW system under the same conditions.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Studien omfattar en undersökning av en byggnad i Surabaya, Indonesien belägen på universitet UBAYA. Användningen av luftkonditionering ökar kraftigt i utvecklingsländer. Detta gör att behovet av förbättringar i såväl klimatanläggningar som i byggnader kommer att vara nödvändiga för att inte orsaka ytterligare påfrestningar på miljön genom ökad energianvändning Syftet med studien är att hitta energibesparande åtgärder på byggnadens klimatskal med hänsyn till det tropiska klimatet utan att orsaka fuktproblem i ingående byggnadsdelar. Byggnaden fungerar i dagsläget bra ur fuktsynpunkt och har inga direkt synliga skador orsakade av fuktproblem i konstruktionen. Däremot påvisar det höga uvärdet för byggnaden dess ineffektivitet gällande energibehov. Fyra olika åtgärdsförslag med utgångspunkt i den nuvarande konstruktionen presenteras i studien. Åtgärdsförslagen utvärderas ur fuktsynpunkt med programmet WUFI samt ur ett energimässigt perspektiv med programmet Polysun. Resultatet visar att störst energibesparing kan ske genom att isolera taket då det visar sig vara en stor värmekälla till byggnaden. Denna åtgärd innebär samtidigt en viss risk för fuktproblem på grund av höga relativa fukthalter och temperaturer. Även en tätning av de nuvarande läckagen i byggnaden påverkar energiförbrukningen i stor utsträckning, vilket gör dessa två åtgärder till den bästa kombinationen för att sänka energiförbrukningen. Att byta ut nuvarande englaskassetter mot tvåglas samt isolera de befintliga ytterväggarna är de åtgärder som påverkar energibehovet minst. Några av de slutsatser som dras ur studien är att totalt sett kan byggnadens energiförbrukning sänkas med 50 % om samtliga åtgärdsförslag genomförs. Fuktriskerna ökar vid isoleringsåtgärder men är genomförbara.