979 resultados para implant dentistry
Resumo:
Statement of problem. An imprecise fit between frameworks and supporting dental implants in loaded protocols increases the strain transferred to the periimplant bone, which may impair healing or generate microgaps.Purpose. The purpose of this study was to investigate the microstrain between premachined 1-piece screw-retained frameworks (group STF) and screw-retained frameworks fabricated by cementing titanium cylinders to the prefabricated framework (group CTF). This procedure was developed to correct the misfit between frameworks and loaded implants.Material and methods. Four internal hexagon cylindrical implants were placed 10 mm apart in a polyurethane block by using the surgical guides of the corresponding implant system. Previously fabricated titanium frameworks (n=10) were divided into 2 groups. In group STF, prefabricated machined frameworks were used (n=5), and, in group CTF, the frameworks were fabricated by using a passive fit procedure, which was developed to correct the misfit between the cast titanium frameworks and supporting dental implants (n=5). Both groups were screw-retained under torque control (10 Ncm). Six strain gauges were placed on the upper surface of the polyurethane block, and 3 strain measurements were recorded for each framework. Data were analyzed with the Student t test (alpha=.05).Results. The mean microstrain values between the framework and the implants were significantly higher for group STF (2517 me) than for group CTF (844 me) (P<.05).Conclusions. Complete-arch implant frameworks designed for load application and fabricated by using the passive fit procedure decreased the strain between the frameworks and implants more than 1 piece prefabricated machined frameworks.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Purpose: This study aimed to investigate the influence of ceramic thickness and shade on the Knoop hardness and dynamic elastic modulus of a dual-cured resin cement.Materials and Methods: Six ceramic shades (Bleaching, A1, A2, A3, A3.5, B3) and two ceramic thicknesses (1 mm, 3 mm) were evaluated. Disk specimens (diameter: 7 mm; thickness: 2 mm) of the resin cement were light cured under a ceramic block. Light-cured specimens without the ceramic block at distances of 1 and 3mm were also produced. The Knoop hardness number (KHN), density, and dynamic Young's moduli were determined. Statistical analysis was conducted using ANOVA and a Tukey B rank order test (p = 0.05).Results: The bleaching 1-mm-thick group exhibited significantly higher dynamic Young's modulus. Lower dynamic Young's moduli were observed for the 3-mm-thick ceramic groups compared to bleaching 3-mm-thick group, and no difference was found among the other 3-mm groups. For the KHN, when A3.5 3-mm-thick was used, the KHN was significantly lower than bleaching and A1 1-mm-thick ceramic; however, no difference was exhibited between the thicknesses of the same shade.Conclusions: The dual-cured resin cement studied irradiated through the 1-mm-thick ceramic with the lightest shade (bleaching ceramic) exhibited a better elastic modulus, and there was no effect in KHN of the resin cement when light cured under different ceramic shades and thicknesses (1 and 3 mm), except when the A3.5 3-mm-thick ceramic was used.Clinical Significance: Variolink II irradiated through ceramic with the lowest chroma exhibited the highest elastic modulus; therefore, the light activation method might not be the same for all clinical situations.
Resumo:
PurposeThe mechanical properties of acrylic resins used in intraoral prostheses may be altered by frequent exposure to liquids such as beverages and mouthwashes. This study aimed to evaluate the effect of thermocycling and liquid immersion on the hardness of four brands of acrylic resins commonly used in removable prostheses (Onda Cryl, QC-20, Classico, Lucitone).Materials and MethodsFor each brand of resin, seven specimens were immersed in each of six solutions (coffee, cola, red wine, Plax-Colgate, Listerine [LI], Oral B), and seven more were placed in artificial saliva (control). The hardness was tested using a microhardness tester before and after 5000 thermocycles and after 1, 3, 24, 48, and 96 hours of immersion. The results were analyzed using three-way repeated-measures ANOVA and Tukey's test (p < 0.05).ResultsThe hardness of the resins decreased following thermocycling and immersion in the solutions. Specimens immersed in cola and wine exhibited significant decreases in hardness after immersion for 96 hours, although the greatest significant decrease in hardness occurred in specimens immersed in LI. However, according to American Dental Association specification 12, the Knoop hardness of acrylic resins for intraoral prostheses should not be below 15. Thus, the median values of superficial hardness observed in most of the acrylic resins in this study are considered clinically acceptable.ConclusionsThe microhardness of polymers used for intraoral prostheses decreases following thermocycling. Among specimens immersed in beverages, those immersed in cola or wine experienced the greatest decrease in microhardness. Immersion of acrylic resins in LI significantly decreased the microhardness in relation to the initial value. Among the resins assessed, QC-20 exhibited the lowest initial hardness.
Resumo:
The CAD/CAM technology associated with rapid prototyping (RP) is already widely used in the fabrication of all-ceramic fixed prostheses and in the biomedical area; however, the use of this technology for the manufacture of metal frames for removable dentures is new. This work reports the results of a literature review conducted on the use of CAD/CAM and RP in the manufacture of removable partial dentures.
Resumo:
The fracture of porcelain structures have been related in either natural dentition or implant-supported restorations. Techniques using a composite resin or indirect methods can be used. This article presents a porcelain fracture on implant-supported metal-ceramic restoration. IPS Empress e.max laminate veneer restoration was used to repair the fracture. With this technique, it was possible to restore aesthetics and function, combined with low cost and patient satisfaction.
Resumo:
One of the main reasons for the failure in dental implant treatments is the overload, which can cause bone resorption and later, the osseointegration loss in the implant. Therefore, the aim of this study was to analyze the tension generated around dental implants in the rehabilitation of three mandible posterior teeth, varying the connection type, the disposal, and the quantity of implants. The photoelasticity method was used in order to accomplish it. Through photoelasticity, the quantity and localization of the tensions around the implants in the different studied groups were compared (three straight line implants, three offset placement implants, two implants with a mesial cantilever, and two implants with a pontic). The results showed that the tension quantity and disposition around the dental implants of the connection external hexagon and internal hexagon were similar in all groups. In the group where the cantilever was used, an increase of the tension around the implant, adjacent to the cantilever, was observed. From the results it is concluded that the type of connection used in this study did not influence the tension quantity and distribution around the implants; however, the prosthetic configuration with the cantilever use, led to an increase of the tension around the implant, adjacent to the cantilever.
Resumo:
Schwartz-Jampel syndrome (SJS) is a rare recessive disorder characterized mainly by myotonia. As the clinical signs and symptoms are manifested in the oromaxillofacial region, paediatric dentists may be first choice of parents that seek information and assistance to their children. A female patient diagnosed with SJS was brought to our clinic for dental treatment with main complain of difficulty on oral hygiene and mastication due to tooth crowding. The treatment included preventive measures, extraction of a supernumerary tooth and the maxillary primary second molars. Furthermore, the patient was referred to orthodontic treatment for correction of tooth crowding. When dealing with children with confirmed diagnosis of SSJ, paediatric dentists should be understand the need of planning the dental treatment considering the characteristics and possible complications associated with the syndrome in order to reduce the risks to patients, especially when surgical procedures are necessary.
Resumo:
To assess the impact of the "Dentistry for Infants" early dental care program run by Jacareí County (SP) by comparing the caries of individuals participating and not participating in this program. Methods: In total, 300 children between 0 and 48 months old were assessed in the following two groups: infants not participating in the program (G1, n = 100) and infants participating in the program (G2, n = 200). Each group was further divided according to age in subgroups of 0 to 24 months and 25 to 48 months. All children were clinically assessed for carious lesions using the visual-tactile method. The data were statistically analyzed using a paired Student's t-test, Mann-Whitney test, and c 2 test at a 5% significance level. Results: There was a significant difference in the prevalence (P) and mean index of deciduous teeth (deft) (C) that were decayed, indicated for extraction and filled, and the highest values were observed in G1 (p < 0.0001). The values were as follows: PG1, 73%; PG2, 22%; CG1, 3.45 ± 3.84; and CG2, 0.66 ± 1.57. Conclusion: Participating in the program positively impacted the infants' oral health.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES
Resumo:
Dental implants represent a great improvement in Dentistry in respect to rehabilitation of edentulous ridges due to the functional and aesthetic reestablishment with long-term predictability and success. However, the effectiveness of this treatment relies on successful osseointegration during the healing period. In this way, the applicability of dental implants in patients with diabetes mellitus (DM) remains controversial, by the fact that the hyperglycemic status presents a negative effect on the osseointegration. It is not clear yet if the therapy with dental implants is an absolute contraindication to these patients. For this reason, the aim of the present study is to review the literature about the treatment with dental implants in patients with diabetes and to propose a protocol to perform dental implants in patients with diabetes. Diabetes has been considered a relative contraindication to dental implants, as the patients with adequate metabolic control can be treated with this kind of therapy, because inadequate metabolic control can lead to the failure of the treatment. Besides, there are risk factors for the diabetic implant patient that may decrease the success rates of dental implants therapy. In this way, the dentist should understand all the relevant implications before considering the indication of dental implants to patients with diabetes. It is important to have more controlled studies to evaluate the effects of diabetes on the implant-tissue interface and further investigations are necessary in order to elucidate the role of insulin and molecular mechanisms that might interfere on the osseointegration in patients with diabetes.
Resumo:
The correction of bone defects is the restoration of lost structures which can be replaced by alloplastic implants or bone grafts. Due to the known disadvantages of removal of autogenous grafts, most researches in dentistry aim to develop alloplastic or non-alloplastic materials able to replace bone without these limitations. Beta-Tricalcium Phosphate (β-TCP) is a synthetic granular bone substitute, biocompatible, osteoconductive, which can be used in the alveolar reconstruction. In this work, we perform a literature review on the β-TCP characteristics and discuss its application in dentistry.
Resumo:
The use of bone grafts from bone tissue banks, also known as bone allografts, has increased in the last years, although most of its users still have concerns on resources and processing protocols. The objective of this paper was to make a literature review about the use of bone allografts in Dentistry, and also about the legal considerations regarding this biomaterial. Studies regarding the donor selection, the cross-infection risks and processing protocols of this biomaterial are still rare but essential, and allied to those regarding its clinical application, can base its use.
Resumo:
AIM: The aim of this study was to evaluate, through a systematic review of the literature, the effects of different implant surface modifications on osseointegration in diabetic subjects. METHODS: A search was performed of the PubMed database, using a combination of the following keywords: “Implant surface” OR “Dental implants” AND “Diabetes” OR “Hyperglycemia”. Papers published in English between January 1960 and November 2013 were selected. All experimental models were considered in this search, but case reports and in vitro studies were excluded from this review. RESULTS: The initial search identified 182 articles. After reading the titles and abstracts, 39 articles were selected for full reading. Finally, 4 papers were selected after evaluation of all the papers, and these papers are discussed in this review. Due to the methodological heterogeneity of the selected studies, it was not possible to perform a meta-analysis of the data. CONCLUSION: It can be concluded that although the benefits of surface modifications present in individuals with diabetes have biological plausibility, there is little evidence of the benefits of these modifications.
Resumo:
Objective The objective of this article is to present options of rehabilitation with dental implants in two cases of severely atrophic mandibles (<10 mm) after rigid internal fixation of fractures. Patients and method Two patients who sustained fractures in severely atrophic mandibles with less than 10 mm of bone height were treated by open reduction and internal fixation through a transcervical access. Internal fixation was obtained with 2.4-mm locking reconstruction plates. The first patient presented satisfactory bone height at the area between the mental foramens and after 2 years, received flapless guided implants in the anterior mandible and an immediate protocol prosthesis. The second patient received a tent pole iliac crest autogenous graft after 2 years of fracture treatment and immediate implants. After 5 months, a protocol prosthesis was installed in the second patient. Results In both cases, the internal fixation followed AO principles for load-bearing osteosynthesis. Both prosthetic devices were Branemark protocol prosthesis. The mandibular reconstruction plates were not removed. Both patients are rehabilitated without complications and satisfied with esthetic and functional results. Conclusion With the current techniques of internal fixation, grafting, and guided implants, the treatment of atrophic mandible fractures can achieve very good results, which were previously not possible.