870 resultados para embolization agent


Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To retrospectively determine the sensitivity of ovarian artery (OA) visualization at aortography performed after uterine fibroid embolization (UFE) and, using OA arteriography as the reference standard, compare the extent of arterial flow to the uterus at aortography with selective ovarian arteriography, to establish the utility of aortography and ovarian arteriography in the routine practice of UFE. MATERIALS AND METHODS: This study received institutional review board approval with waiver of informed consent and was HIPAA compliant. Retrospective review of 1129 consecutive UFE patients (1072 with aortograms, 57 excluded; mean age, 44 years; range, 21-60 years) was performed to identify all visible OAs. Visible OAs were independently graded by two interventional radiologists according to extent of pelvic arterial flow. If selective arteriography was performed, a second grade was assigned based on assessment of the selective study. Descriptive and summary statistics were used for assessment by the senior observer, and interobserver variability was determined. RESULTS: Of 1072 UFE patients, 184 (17.2%) had at least one visible OA. Ten (0.8%) patients were identified at aortography with collateral OA supply to more than 10% of the uterus. In total, 251 OAs were visualized, and 157 of these were further evaluated with selective study. Sixty-two (5.8%) patients were identified at selective arteriography as having collateral OA supply. The sensitivity of aortography was approximately 18%. Interobserver concordance was high (kappa values of 0.81 and 0.90 for aortography and selective study, respectively), but not perfect. CONCLUSION: Aortography rarely helps identify patients with substantial residual OA supply to the uterus and is a poor predictor of the extent of that supply, and thus may be of limited utility in routine UFE.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To evaluate the acute and midterm effectiveness of a novel vascular occlusion device for embolization of the internal iliac artery (IIA) before endovascular repair of aortoiliac aneurysms. MATERIALS AND METHODS: Between March 2005 and April 2006, nine men (mean age, 75 years +/- 5; range, 66-83 y) with aortoiliac aneurysms underwent bifurcated endovascular stent-graft procedures. All these patients were referred specifically for embolization. Pre- and perioperatively, eight patients underwent unilateral embolization and one underwent bilateral embolization of the IIA to prevent type II endoleak. Via a contralateral femoral approach with a 6-F or 8-F sheath, the embolization procedure was performed with an Amplatzer Vascular Plug, a self-expandable cylindrical device consisting of a nitinol-based wire mesh. Technical success, clinical outcome, and complications were evaluated. Follow-up at 3, 6, and 12 months was performed with clinical and radiologic examinations. RESULTS: IIA embolization was technically successful in all cases and no procedure-related complications occurred. Imaging at discharge and at 3-, 6-, or 12-month follow-up was accomplished in all nine patients. Control computed tomography and magnetic resonance angiography did not reveal retrograde perfusion of the aneurysmal sac, ie, type II endoleak. Three of nine patients (33.3%) reported symptoms of buttock claudication that did not resolve completely. Clinical symptoms such as bowel ischemia or sexual dysfunction were not observed. CONCLUSIONS: The midterm results of this study suggest that preoperative IIA embolization with a nitinol vascular occlusion plug during endovascular treatment of aortoiliac aneurysms is safe and effective.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We describe the successful selective coil embolization of an infected superior gluteal pseudoaneurysm secondary to methicillin-resistant Staphylococcus aureus (MRSA) in a 36-year old women. The patient presented with a long history of drug abuse and perisacral abscesses due to chronic sacroilitis. The chosen strategy provides a safe and successful management of infected false gluteal artery aneurysm.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Considering the documented, potentially undesirable influence of various thiazide-type or loop diuretics on serum lipoproteins, we prospectively investigated in 69 men (mean age +/- SEM, 32 +/- 1 years) the metabolic effects of the new diuretic-antihypertensive compound indapamide. Compared to placebo, indapamide (2.5 mg/day) given for 6 to 8 weeks lowered (p less than 0.02 to less than 0.001) blood pressure (supine values from 148/98 +/- 3/2 to 137/93 +/- 3/2) in 29 men with mild to moderate essential hypertension, but not in 40 healthy men. In both groups, significant (p less than 0.05 to less than 0.001) decreases in body weight (-0.8 kg) and plasma potassium (-0.6 mmol/L), and increases in plasma uric acid (+20%), renin activity (+200%), and aldosterone documented good compliance. There were no significant changes in total cholesterol (in all subjects, from 208 +/- 6 to 213 +/- 6 mg/dl), low- or very low-density lipoprotein (VLDL) cholesterol (127 +/- 6 to 129 +/- 6 and 21 +/- 1 to 21 +/- 2 respectively), high-density lipoprotein cholesterol (50 +/- 1 to 51 +/- 1 mg/dl), total triglycerides (Tg) (108 +/- 5 to 112 +/- 6 mg/dl), VLDL-Tg, apoproteins A1 and A2, plasma glucose, epinephrine, norepinephrine, sodium, calcium, magnesium, and creatinine; apoprotein B (84 +/- 2 to 88 +/- 3 mg/dl) and plasma insulin after glucose loading dose tended to be increased minimally. The absence of distinct lipoprotein alterations after short-term indapamide treatment may be of clinical and epidemiological interest.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This dissertation involves study of various aspects of sulfoxide chemistry. Specifically designed t-butyl and propanenitrile sulfoxides tethered to indole-2-carboxamide were used as a source of intramolecular sulfenylating agents to synthesize novel indolo[3,2-b]-1-5-benzothiazepinones which are structurally analogous to the other biologically active benzothiazepinones. This study reveals that the intramolecular cyclization of sulfoxide follows an electrophilic sulfenylation (Sulfoxide Electrophilic Sulfenylation, SES) reaction pathway. Evidence of the absence of sulfenic acid as a transient reactive intermediate in such intramolecular cyclization is also provided. In another study, sulfoxide was used as a “protecting group” of thioether to synthesize 8-membered, indole substituted, thiazocine-2-acetic acid derivative via Ring Closing Metathesis (RCM). Protection (oxidation) of inert (to RCM) sulfide to sulfoxide followed by RCM produced cyclized product in good yields. Deprotection (reduction) of sulfoxide was achieved using Lawessons Reagent (L.R.). Application of the sulfide-sulfoxide redox cycle to solve the existing difficulties in using RCM methodology to thioethers is illustrated. A new design of a “molecular brake”, based on the sulfide-sulfoxide redox cycle is described. N-Ar rotation in simple isoindolines is controlled by the oxidation state of the proximate sulfur atom. Sulfide [S(II)] shows “free” [brake OFF] N-Ar rotation whereas sulfoxide displayed hindered [brake ON] N-Ar rotation. The semi-empirical molecular orbital (PM3) calculations revealed concerted pyramidalization of amidic nitrogen with N-Ar rotation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Postmortem minimal invasive angiography has already been implemented to support virtual autopsy examinations. An experimental approach in a porcine model to overcome an initially described artificial tissue edema artifact by using a poly ethylene glycol (PEG) containing contrast agent solution showed promising results. The present publication describes the first application of PEG in a whole corpse angiographic CT examination. A minimal invasive postmortem CT angiography was performed in a human corpse utilizing the high viscosity contrast agent solution containing 65% of PEG. Injection was carried out via the femoral artery into the aortic root in simulated cardiac output conditions. Subsequent CT scanning delivered the 3D volume data of the whole corpse. Visualization of the human arterial anatomy was excellent and the contrast agent distribution was generally limited to the arterial system as intended. As exceptions an enhancement of the brain, the left ventricular myocardium and the renal cortex became obvious. This most likely represented the stage of centralization of the blood circulation at the time of death with dilatation of the precapillary arterioles within these tissues. Especially for the brain this resulted in a distinctively improved visualization of the intracerebral structures by CT. However, the general tissue edema artifact of postmortem minimal invasive angiography examinations could be distinctively reduced.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The complexity and challenge created by asphalt material motivates researchers and engineers to investigate the behavior of this material to develop a better understanding, and improve the performance of asphalt pavement. Over decades, a wide range of modification at macro, meso, micro and nano scales have been conducted to improve the performance of asphalt pavement. This study was initiated to utilize the newly developed asphalt modifier pellets. These pellets consisted of different combinations of calcium carbonate (CaCO3), linear low-density polyethylene (LLDPE) and titanate coupling agent (CA) to improve the asphalt binder as well as pavement performance across a wide range of temperature and loading pace. These materials were used due to their unique characteristics and promising findings from various industries, especially as modifiers in pavement material. The challenge is to make sure the CaCO3 disperses very well in the mixture. The rheological properties of neat asphalt binder PG58-28 and modified asphalt binder (PG58-28/LLDPE, PG58-28/CaCO3, PG58-28/CaCO3/LLDPE, and PG58-28/CaCO3/LLDPE/CA), were determined using rotational viscometer (RV) test, dynamic shear rheometer (DSR) test and bending beam rheometer test. In the DSR test, the specimens were evaluated using frequency sweep and multiple shear creep recovery (MSCR). The asphalt mixtures (aggregate/PG58-28, aggregate/ PG58-28/LLDPE, aggregate/PG58-28/CaCO3, aggregate/PG58-28/LLDPE/CaCO3 and aggregate/PG58-28/LLDPE/CaCO3/CA) were evaluated using the four point beam fatigue test, the dynamic modulus (E*) test, and tensile strength test (to determines tensile strength ratio, TSR). The RV test results show that all modified asphalt binders have a higher viscosity compared to the neat asphalt binder (PG58-28). Based on the Jnr results (using MSCR test), all the modified asphalt binders have a better resistance to rutting compared to the neat asphalt binder. A higher modifier contents have resulted in a better recovery percentage of asphalt binder (higher resistance to rutting), except the specimens prepared using PECC’s modified asphalt binder (PG58-28/CaCO3/LLDPE). The BBR test results show that all the modified asphalt binders have shown comparable performance in term of resistance to low temperature cracking, except the specimen prepared using the LLDPE modifier. Overall, 5 wt% LLDPE modified asphalt binder was found to be the best asphalt binder in terms of resistance to rutting. Meanwhile, 3 wt% PECC-1CA’s modified asphalt binder can be considered as the best (in terms of resistance to thermal cracking) with the lowest mean critical cracking temperature. The appearance of CaCO3 was found useful merely in improving the resistance to fatigue cracking of asphalt mixture. However, application of LLDPE has undermined the fatigue life of asphalt mixtures. Adding LLDPE and coupling agent throughout this study does not sufficiently help in terms of elastic behavior which essential to enhance the resistance to fatigue cracking. In contrast, application of LLDPE has increased the indirect tensile strength values and TSR of asphalt mixtures, indicates a better resistance to moisture damage. The usage of the coupling agent does not change the behavior of the asphalt mixture, which could be due to imbalance effects resulted by combination of LLDPE and CaCO3 in asphalt binder. Further investigations without incorporating CaCO3 should be conducted further. To investigate the feasibility of using LLDPE and coupling agent as modifiers in asphalt pavements, more research should be conducted on different percentages of LLDPE (less than 3 wt%), and at the higher and w wider range of coupling agent content, from 3 wt% to 7 wt% based on the polymer mass.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A systematic comparison has been performed of the morphology and stability of microtubules (MTs) induced by the potent microtubule-stabilizing agents (MSAs) taxol, epothilone B (Epo B), and discodermolide (DDM) under GTP-free conditions. DDM-induced tubulin polymerization occurred significantly faster than that induced by taxol and Epo B. At the same time, tubulin polymers assembled from soluble tubulin by DDM were morphologically distinct (shorter and less ordered) from those induced by either taxol or Epo B, as demonstrated by electron microscopy. Exposure of MSA-induced tubulin polymers to ultrasound revealed the DDM-based polymers to be less stable to this type of physical stress than those formed with either Epo B or taxol. Interestingly, MT assembly in the presence of both DDM and taxol appeared to produce a distinct new type of MT polymer with a mixed morphology between those of DDM- and taxol-induced structures. The observed differences in MT morphology and stability might be related, at least partly, to differences in intramicrotubular tubulin isotype distribution, as DDM showed a different pattern of beta-tubulin isotype usage in the assembly process.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To evaluate the efficacy of superselective embolization therapy in the management of acute lower gastrointestinal (LGI) hemorrhage, including any bleeding distal to the ligament of Treitz. MATERIALS AND METHODS: Between June and August 2007, 20 patients with acute LGI bleeding underwent superselective transcatheter arterial embolization (TAE) at the authors' institution. The bleeding had different causes. All patients were treated with use of microcatheters. The following embolic agents were used: microcoils (n = 16), polyvinyl alcohol (PVA) particles (n = 2), and a combination of microcoils and PVA particles (n = 2). Outcome measures included technical success (complete cessation of bleeding as documented at completion angiography), clinical success (resolution of signs or symptoms of LGI bleeding within 30 days after TAE), and the rate of major and minor complications. RESULTS: The identified bleeding sources were as follows: jejunal branch, branch of middle colic artery, branch of ileocolic artery, ileal branch, branch of left colic artery, branch of sigmoid artery, branch of the superior rectal artery, and branch of the middle rectal artery. Technical success with effective control of active bleeding was achieved in all patients (100%). Clinical success attributed to TAE was documented in 18 of the 20 patients (90%). Major complications included death due to pulmonary embolism, heart infarction, and multiorgan failure in the 3rd week after TAE; a procedure-related colonic infarction occurred in one patient. A minor complication occurred in one patient who developed a groin hematoma. CONCLUSIONS: Superselective embolization may be used for effective, minimally invasive control of acute LGI bleeding.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This thesis will present strategies for the use of plug-in electric vehicles on smart and microgrids. MATLAB is used as the design tool for all models and simulations. First, a scenario will be explored using the dispatchable loads of electric vehicles to stabilize a microgrid with a high penetration of renewable power generation. Grid components for a microgrid with 50% photovoltaic solar production will be sized through an optimization routine to maintain storage system, load, and vehicle states over a 24-hour period. The findings of this portion are that the dispatchable loads can be used to guard against unpredictable losses in renewable generation output. Second, the use of distributed control strategies for the charging of electric vehicles utilizing an agent-based approach on a smart grid will be studied. The vehicles are regarded as additional loads to a primary forecasted load and use information transfer with the grid to make their charging decisions. Three lightweight control strategies and their effects on the power grid will be presented. The findings are that the charging behavior and peak loads on the grid can be reduced through the use of distributed control strategies.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND AND AIM OF THE STUDY: Recent studies have suggested placental growth factor (PlGF) and vascular endothelial growth factor (VEGF) as promising new biomarkers for risk stratification in acute coronary syndromes (ACS). However, little is known about the influence of percutaneous coronary intervention (PCI) on circulating PlGF and VEGF levels. METHODS: Thirty-five patients with ACS, 27 patients with stable coronary artery disease (sCAD), and nine healthy controls were enrolled in the study. Although all patients with ACS and 14 patients with stable angina pectoris underwent PCI, 13 patients with coronary artery disease required no revascularization (sCAD). PlGF and VEGF plasma concentrations were measured by immunoassay during and at the end of PCI and coronary angiography. RESULTS: Plasma PlGF levels were comparable in patients with ACS and sCAD on admission. Although coronary angiography or heparin alone did not alter PlGF and VEGF levels, immediately after PCI a dramatic increase was seen in circulating PlGF and a decrease in VEGF, which was independent of the clinical presentation of the patients, heparin administration, or the angiographic procedure itself, but was associated with the extent of coronary artery disease and the amount of the injected contrast media. In-vitro experiments revealed that radiocontrast agents induced the release of PlGF from endothelial cells without altering PlGF mRNA expression. CONCLUSION: Patients undergoing PCI exhibit an increase in circulating PlGF, probably caused by posttranslational modifications of radiocontrast agents in endothelial cells. Therefore, analysis of plasma PlGF and VEGF levels may consider the timing of blood sampling with respect to PCI and contrast media exposure.