968 resultados para electronic devices


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: The aim of this study was to investigate the feasibility of transventricular-transseptal approach (TVSA) for extrapleural transcatheter aortic valved stent implantation via a subxyphoidian access. Methods: In five porcine experiments (52.3 +/- 10.9 kg) the right ventricle was exposed via subxyphoidian access. Under the guidance of intracardiac echocardiography (ICE) and fluoroscopy, the transseptal access from right ventricle to left ventricle was created progressively by puncture and dilation with dilators (8F-26F). Valved stents built in-house from commercial tanned pericardium and self-expandable Nitinol stents were loaded into a cartridge. A delivery sheath was then introduced from the right ventricle into the left ventricle and then into the ascending aorta. The cartridge was connected and the valved stent was deployed in the aortic position. Then, the ventricular septal access was sealed with an Amplatzer septal occluder device and the right ventricular access was closed by tying prepared purse-string suture directly. Thirty minutes after the whole procedure, the animals were sacrificed for macroscopic evaluation of the position of valved stent and septal closure device. Result: Procedural success of TVSA was 100% at the first attempt. Mean procedure time was 49 +/- 4 min. Progressive dilatation of the transseptal access resulted in a measurable ventricular septal defect (VSD) after dilator sizes 18F and more. All valved stents were delivered at the target site over the native aortic valve with good acute valve function and no paravalvular leaks. During the procedure, premature beats (5/5) and supraventriclar tachycardias (5/5) were observed, but no atrial-ventricular block (0/5) occurred. Heart rate before (after) was 90 +/- 3 beats min(-1) (100 +/- 2 beats min(-1): p < 0.05), whereas blood pressure was 60 + 1 mm Hg (55 + 2 mm Hg (p < 0.05)). Total blood loss was 280 + 10 ml. The Amplatzer septal occluder devices were fully deployed and the ventricular septal accesses were sealed successfully, without detectable residual shunt. Conclusion: Trans-catheter implantation of aortic valved stent via extrapleural transventricular-transseptal access is technically feasible and has the potential for a simplified procedure under local anaesthesia. (C) 2010 European Association for Cardio-Thoracic Surgery. Published by Elsevier B. V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aquest TFC es basa en la implementació d'un programa de gestió de treballadors per a aplicar-lo a una empresa de petites dimensions, dedicada al manteniment d'aparells elevadors.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The Atripump is a motorless, volume displacement pump based on artificial muscle technology that could reproduce the pump function of normal atrium. It could help prevent blood clots due to blood stagnation and eventually avoid anticoagulation therapy in atrial fibrillation (AF). An animal study has been designed to assess mechanical effects of this pump on fibrillating atrium. The Atripump is a dome shaped silicone coated nitinol actuator. A pacemaker like control unit drives the actuator. In five adult sheep, the right atrium (RA) was exposed and dome sutured onto the epicardium. Atrial fibrillation was induced using rapid epicardial pacing (600 beats/min). Ejection fraction of the RA was obtained with intracardiac ultrasound in baseline, AF and Atripump assisted AF conditions. The dome's contraction rate was 60/min with power supply of 12V, 400 mA for 200 ms and ran for 2 hours in total. Mean temperature on the RA was 39+/-1.5 degrees C. Right atrium ejection fraction was 31% in baseline conditions, 5% and 20% in AF and assisted AF, respectively. In two animals a thrombus appeared in the right appendix and washed out once the pump was turned on. The Atripump washes blood out the RA acting as an anticoagulant device. Possible clinical implications in patients with chronic AF are prevention of embolism of cardiac origin and avoidance of hemorrhagic complication due to chronic anticoagulation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Nonadherence to treatment is a common problem in the clinical management of hypercholesterolemic patients. This study was carried out with the aim of monitoring the daily compliance to a 6-month course of lipid-lowering therapy, using a microelectronic device, the Medication Event Monitoring System (MEMS), versus pill count. Forty men with primary hypercholesterolemia were prescribed fluvastatin 1 x 40 mg daily, provided in a MEMS package to record the date and time of each opening of the pillbox. Thirty-nine of 40 patients (98%) completed the study. Total cholesterol and LDL cholesterol levels decreased significantly (18% and 25%, p < 0.001) during the 6-month therapy period. A high mean rate of compliance was achieved by MEMS using the following three indexes--compliance to total prescribed dose (88.8% +/- 13.5%), compliance to prescribed days (82.4% +/- 19.5%), and compliance to prescribed time of day (81.86% +/- 19.5%)--and by pill count (93.4% +/- 9.5%). In addition, the MEMS provided some patterns of nonadherence to medication, undetectable by pill count alone, such as a drug holiday in 38% of cases, a drug omission for more than 7 consecutive days in 9% of cases, and, conversely, use of more than the one prescribed daily dose in 47% of cases. A significant correlation between the rate of compliance and the decrease in LDL cholesterol was observed only when the compliance was assessed by MEMS. The results indicate that MEMS is a useful tool for monitoring compliance in clinical practice and may possibly increase adherence to long-term lipid-lowering therapy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The role of Propionibacterium acnes in acne and in a wide range of inflammatory diseases is well established. However, P. acnes is also responsible for infections involving implants. Prolonged aerobic and anaerobic agar cultures for 14 days and broth cultures increase the detection rate. In this paper, we review the pathogenic role of P. acnes in implant-associated infections such as prosthetic joints, cardiac devices, breast implants, intraocular lenses, neurosurgical devices, and spine implants. The management of severe infections caused by P. acnes involves a combination of antimicrobial and surgical treatment (often removal of the device). Intravenous penicillin G and ceftriaxone are the first choice for serious infections, with vancomycin and daptomycin as alternatives, and amoxicillin, rifampicin, clindamycin, tetracycline, and levofloxacin for oral treatment. Sonication of explanted prosthetic material improves the diagnosis of implant-associated infections. Molecular methods may further increase the sensitivity of P. acnes detection. Coating of implants with antimicrobial substances could avoid or limit colonization of the surface and thereby reduce the risk of biofilm formation during severe infections. Our understanding of the role of P. acnes in human diseases will likely continue to increase as new associations and pathogenic mechanisms are discovered.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The paper describes how to integrate audience measurement and site visibility as the main research approaches in outdoor advertising research in a single concept. Details are portrayed on how GPS is used on a large scale in Switzerland for mobility analysis and audience measurement. Furthermore, the development of a software solution is introduced that allows the integration of all mobility data and poster location information. Finally a model and its results is presented for the calculation of coverage of individual poster campaigns and for the calculation of the number of contacts generated by each billboard.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Decompensated heart failure, either acute (cardiogenic shock) or chronic (terminal heart failure) may become refractory to conventional therapy, then requiring mechanical assistance of the failing heart to improve hemodynamics. In the acute setting, aortic balloon counterpulsation is used as first line therapy. In case of failure, other techniques include the extracorporal membrane oxygenator or a percutaneous left ventricular assist device, such as the TandemHeart or the Impella. In chronic heart failure, long-term left ventricular assist devices can be surgically implanted. The continuous flow devices give here the best results. The aim of the present review article is to present with some details the various methods of mechanical left ventricle assistance to which the intensivist may be confronted in his daily practice.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

La Biblioteca de la UOC (BUOC) ha ofert durant tres mesos (octubre-desembre 09), en fase de prova pilot, un servei de consulta i préstec de lectors de llibres electrònics (e-readers). Aquest nou desplegament s'ha desenvolupat en consonància amb l'aposta general de la Universitat en innovació en tecnologies aplicades a l'educació, i la voluntat de potenciar les col·leccions de llibres electrònics i l'ús dels dispositius de lectura de llibres electrònics com una extensió més de la tecnologia del Campus 5.0, en el suport a l'aprenentatge dels seus estudiants durant la seva formació a la Universitat. Aquest treball presenta en detall les especificacions de la prova pilot a més de contenir un anàlisi i avaluació dels resultats obtinguts: punts forts i punts febles, relació dels aspectes a millorar i modificar, de cara a la consolidació final del servei.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

La Biblioteca de la UOC (BUOC) ha ofert durant tres mesos (octubre-desembre09), en fase de prova pilot, un servei de consulta i préstec de lectors dellibres electrònics (e-readers). Aquest nou desplegament s'ha desenvolupat d'acordamb l'aposta general de la Universitat per la innovació en tecnologies aplicades al'ensenyament, i la voluntat de potenciar les col·leccions de llibres electrònics i l'úsdels dispositius de lectura de llibres electrònics com una extensió més de latecnologia del Campus 5.0, en el suport a l'aprenentatge dels estudiants durant laseva formació a la Universitat. Aquest treball presenta en detall les especificacionsde la prova pilot, a més de contenir una anàlisi i una avaluació dels resultatsobtinguts: punts forts i punts febles, i relació dels aspectes que cal millorar i modificaramb vista a la consolidació final del servei.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

L'Experiència del servei de préstec d'e-readers i llibres-e a la Biblioteca de la UOC

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Conferència emmarcada dins el IV Workshop BiblioUdG on s'explica l'experiència del servei de préstec de llibres electrònics de la Biblioteca de la UOC, analitzant el procés d'implantació d'una prova pilot realitzada durant el primer trimestre del curs 2009-2010 i els resultats obtinguts

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Presentació de l'experiencia del servei de consulta i préstec de llibres electrònics a la Biblioteca de la UOC, en el marc de la Jornada de Comunicación del Proyecto de Investigación "La influencia de los nuevos dispositivos electrónicos en el fomento de la lectura" a La Casa Encendida de Madrid.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In the context of the digital business ecosystems, small organizations cooperate between them in order to achieve common goals or offer new services for expanding their markets. There are different approaches for these cooperation models such as virtual enterprises, virtual organizations or dynamic electronic institutions which in their lifecycle have in common a dissolution phase. However this phase has not been studied deeply in the current literature and it lacks formalization. In this paper a first approach for achieving and managing the dissolution phase is proposed, as well as a CBR process in order to support it in a multi-agent system

Relevância:

20.00% 20.00%

Publicador:

Resumo:

AIM: Circular stapled mucosectomy is the standard therapy for the treatment of symptomatic third-degree haemorrhoids and mucosal prolapse. Recently, new staplers made in China have entered the market offering an alternative to the PPH stapling devices. The aim of this prospective randomized study was to compare the safety and efficacy of these new devices. METHODS: Fifty patients with symptomatic third-degree haemorrhoids were randomized to mucosectomy either by using stapler A (CPH32; Frankenman International Ltd, Hong Kong, China; n = 25) or stapler B (PPH03; Ethicon Endo-Surgery, Spreitenbach, Switzerland; n = 25). All procedures were performed by two experienced surgeons. After the stapler was fired by one surgeon, the other surgeon, who was blinded for stapler type, evaluated the stapler line. Postoperative outcome including pain, complications and patient satisfaction were analysed. RESULTS: Demographic and clinical features were no different between the groups. There was no significant difference regarding venous bleeding (P = 0.55), but arterial bleeding was significantly more frequent when stapler B was used (P < 0.001). This led to significantly more suture ligations (P = 0.002). However, no differences regarding operation time (P = 0.99), weight of the resected mucosa (P = 0.81) and height of the stapler line (anterior, P = 0.18; posterior, P = 0.65) were detected. Postoperative pain scores (visual analogue scale) and patient satisfaction were no different either (P = 0.91 and P = 0.78, respectively). No recurrence or incontinence occurred during follow-up. CONCLUSIONS: CPH32 required significantly fewer sutures for bleeding control along the stapler line after circular mucosectomy. However, operation time, rate of postoperative complications and patient satisfaction were similar in both groups.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The diagnosis of infections involving internal or external neurosurgical drainage devices is challenging, and to our knowledge no single reliable microbiological test exists. We used sonication to study bacterial colonization in 14 explanted external ventricular drains (EVD) and 13 ventriculo-peritoneal shunt (VPS) devices. This technique dislodges biofilm bacteria from the surface of implanted materials before culture. Removed devices were sonicated in saline (40 kHz, 1 minute, 0.25 W/cm(2)), the resulting fluid was cultured aerobically and anaerobically at 37°C, and bacterial growth was counted. Ventricular cerebrospinal fluid (CSF) was cultured separately. In the EVD group, sonication cultures grew significantly more bacteria (64%, 9/14) than cultures of aspirated ventricular CSF (14%, 2/14). In the VPS group the difference was not significant. Positive sonication cultures of EVD catheters yielded a median of >100 colony forming units (CFU) (range, 60-800). For positive sonication cultures of VPS, the median was 1000 CFU (range, 20-100,000). All patients with bacteria in their CSF also had positive sonication cultures from the removed device. Of the five patients with sterile or presumably contaminated CSF cultures but positive sonication cultures of removed shunts, one became afebrile after removal of the EVD, two developed meningitis and two remained asymptomatic. Sonication culture of EVD appears to improve the microbiological assessment of device-related infection and it corroborates with CSF cultures of revision surgery for VPS. Sonication of the removed EVD tip may raise awareness for the onset of meningitis.