972 resultados para double antibody sandwich ELISA


Relevância:

20.00% 20.00%

Publicador:

Resumo:

We describe the rigorous results of a wide-angle laser beam scanner, obtained with the help of the vector refraction theory. Using the rigorous results, the distortion of the beam shape is discussed. The distortion to the beam varies with the different relative angles of double prisms. The scanner expands the beam in some directions while it contracts the beam in other directions. According to the conservation of energy, the distribution of the laser intensity is changed as well. (c) 2006 Society of Photo-Optical Instrumentation Engineers.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Because of high efficiencies, compact structure, and excellent heat dissipation, high-power fiber lasers are extremely useful for applications such as cutting, welding, precision drilling, trimming, sensing, optical transmitter, material processing, micromachining, and so on. However, the wavefront of the double clad fiber laser doped with ytterbium is still unknown. In this paper, wavefront of a fiber laser is measured and the traditional Hartmann-shack wavefront sensing method is adopted. We measured a double clad fiber laser doped with ytterbium which produces pulse wave output at infrared wavelength. The wavefront shape and contour are reconstructed and the result shows that wavefront is slightly focused and not an ideal plane wavefront. Wavefront measurement of fiber laser will be useful to improving the lasers' performance and developing the coherent technique for its applications.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The frame of a laser diode transmitter for intersatellite communication is concisely introduced. A simple, novel and visual method for measuring the diffraction-limited wavefront of the transmitter by a Jamin double-shearing interferometer is proposed. To verify the validity of the measurement, the far-field divergence of beam is additionally rigorously analysed in terms of the Fraunhofer diffraction. The measurement, the necessary analyses and discussion are given in detail. By directly measuring the fringe widths and quantitatively interpreting the interference fringes, the minimum detectable wavefront height (DWH) of the wavefront is only 0.2 gimel (the distance between the perfect plane wavefront and the actual wavefront at the transmitting aperture) and the corresponding divergence is only 65.84 mu rad. This indicates that the wavefront approaches the diffraction-limited condition. The results show that this interferometer is a powerful tool for testing the semiconductor laser beam's wavefront, especially the diffraction-limited wavefront.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Grating pairs are widely used for pulse compression and stretching. Normally, the two gratings are identical. We propose a very simple structure with double-line-density reflective gratings for pulse compression and generation of double pulses, which has the advantages of no material dispersion, compact in volume, simple in structure, etc. The use of reflective Dammann gratings fully demonstrated the principle of this structure. The output pulses are well verified by a standard frequency-resolved optical gating apparatus. This structure will be highly interesting in ultrashort pulse compression and other more practical applications of femtosecond laser pulses. (c) 2007 Optical Society of America.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Doubled femtosecond laser pulses in-line are needed in the collinear pump-probe technique, collinear second harmonic generation frequency-resolved optical gating (SHG FROG) and the spectral phase interferometry for direct electric-field reconstruction (SPIDER), etc. Normally, it is generated by using a Michelson's structure. In this paper, we proposed a novel structure with two-layered reflective Dammann gratings and the reflective mirrors to generate doubled femtosecond laser pulses in line without transmission optical elements. Angular dispersion and spectral spatial walk-off are both compensated. In addition, this structure can also compress the positive chirped pulse, which cannot be realized with a Michelson's structure. By adopting triangular grating and blazed gratings, the efficiency of the system would in principle be increased as the Michelson's scheme. Experiments demonstrated that this method should be an alternative approach for generation of the double compressed pulses of femtosecond laser for practical applications. (c) 2006 Elsevier GmbH. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Ultrafast lasers ablation of Cr film was investigated by using double-pulse method. Experimental results show that there exists a temporal ablation window effect with each of the double pulses adjusted just smaller than the threshold. When the delay between the double pulses is within the order of 400 ps, the ablation of Cr film could happen. When the delay between the double pulses is beyond the order of 400 ps, the ablation of Cr film would not happen, and the reflectivity from the surface of the Cr film shows a sharp rise at the same time. The two-temperature model was developed into the form of double pulses to explain the experimental phenomena. Furthermore, microbump structures were formed on the surface of Cr film after ablation by ultrafast double pulses. Their heights exhibit an obvious drop between 1 and 10 ps double pulses delay, which is involved with the electron-phonon coupling process according to the numerical simulation. These results should be helpful for understanding the dynamic processes during ultrafast lasers ablation of metal films. (C) 2008 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

New exact solutions of the (2 + 1)-dimensional double sine-Gordon equation are studied by introducing the modified mapping relations between the cubic nonlinear Klein-Gordon system and double sine-Gordon equation. Two arbitrary functions are included into the Jacobi elliptic function solutions. New doubly periodic wave solutions are obtained and displayed graphically by proper selections of the arbitrary functions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Corynebacterium diphtheriae pode ser isolado tanto de quadros de difteria clássica, quanto de infecções sistêmicas, como endocardite. O fibrinogênio (Fbn) e a fibronectina (Fn) são glicoproteínas presentes na matriz extracelular de tecidos conjuntivos. A influência destas proteínas na patogênese das infecções locais e invasivas causadas por C. diphtheriae é objeto de estudo devido ao fato do bacilo diftérico poder ser encontrado em lesões nas quais o Fbn e a Fn são predominantes, incluindo a pseudomembrana diftérica e vegetações cardíacas presentes na endocardite infecciosa. São crescentes as evidências de que o C. diphtheriae pode, além de aderir, ser internalizado por células em cultura. No presente estudo, investigou-se a participação de C. diphtheriae e das proteínas de superfície 67-72p na aderência à Fn e ao Fbn de plasma humano e a eritrócitos. A aderência às células HEp-2 e internalização também foram analisadas. A participação de 67-72p nos mecanismos de morte celular foi avaliada através das colorações por Azul de Tripan e 46-diamidino-2-fenil indol (DAPI), pelo ensaio de redução utilizando dimetil-tiazol-difenil tetrazólio (MTT) e por citometria de fluxo. As 67-72p foram extraídas da superfície da amostra toxigênica C. diphtheriae subsp. mitis CDC-E8392 através de processos mecânicos e precipitação com sulfato de amônio saturado. Análises por SDS-PAGE e immunoblotting detectaram a presença das bandas protéicas de 67 e 72kDa nas amostras toxinogênicas e atoxinogênicas analisadas, as quais pertenciam aos biotipos fermentador e não fermentador de sacarose. C. diphtheriae foi capazes não só de formar agregados na presença de plasma de coelho, mas também de converter Fbn em fibrina independentemente da presença do gene tox. No entanto, a amostra atoxinogênica ATCC 27010 (tox-) foi menos aderente ao Fbn do que a homóloga ATCC 27012 (tox+). A interação bacteriana com eritrócitos foi inibida somente pela Fn. Ligações entre Fn e/ou Fbn com 67-72p foram demonstradas por dot blotting, ELISA e/ou ensaios utilizando fluorescência. As 67-72p foram capazes de inibir as interações bacterianas com o Fbn, indicando que 67-72p podem participar do processo de aderência do patógeno aos tecidos do hospedeiro. Através da microscopia óptica, demonstrou-se a ligação de 67-72p adsorvidas em microesferas de látex com células HEp-2. Anticorpos de coelho do tipo IgG anti 67-72p interferiram somente com a expressão do padrão de aderência do tipo difuso, normalmente apresentado pela amostra CDC-E8392. A Microscopia Eletrônica de Transmissão (MET) e a inibição da internalização bacteriana pela IgG anti 67-72p ou por 67-72p indicaram o papel de 67-72p como invasina. Alterações do citoesqueleto de células HEp-2 com acumulação de actina polimerizada, induzida por microesferas sensibilizadas com 67-72p, foi observada pelo fluorescent actin staining (FAS) test. Foi visualizado um aumento no número de bactérias viáveis no compartimento intracelular após tratamento de células HEp-2 ou dos microrganismos com Fn. A presença de partículas de látex adsorvidas com 67-72p no interior de vacúolos frouxos em células HEp-2 sugeriu que estas proteínas podem causar efeito citotóxico. A avaliação através das colorações com Azul de Tripan, DAPI e os ensaios de redução utilizando MTT demonstraram um decréscimo na viabilidade de células tratadas com 67-72p. As mudanças morfológicas observadas 3 horas após o início do tratamento com 67-72p incluíram vacuolização, fragmentação nuclear e formação de corpúsculos apoptóticos. A citometria de fluxo revelou um decréscimo de 15,13% no volume/tamanho de células tratadas com 67-72p. Além disso, o ensaio utilizando Iodeto de Propídio (IP) e Anexina V (AV)-FITIC demonstrou que havia 66,1% de células vivas (IP-/AV-), 16,6% de células em apoptose inicial (IP-/AV+) e 13,8% de células em apoptose tardia ou necrose secundária. Em conclusão, as 67-72p estão diretamente envolvidas na interação com Fn e Fbn. As proteínas não fimbriais 67-72p são hemaglutininas implicadas na aderência a células respiratórias e na internalização. Além disso, estas proteínas podem atuar como fatores de virulência em potencial para induzir apoptose de células epiteliais nos estágios iniciais da difteria e nas infecções invasivas causadas pelo C. diphtheriae

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this paper, GdFeCo/DyFeCo exchange-coupled double-layer films used for center aperture type magnetically induced super resolution were investigated through experiments and theoretical calculation. The samples were prepared by magnetron sputtering method. The polar Kerr effect was measured to prove the spin reorientation of the readout layer. Theoretical study of magnetization profiles was performed on the basis of the mean-field theory and the continuum model. The theoretical results showed that the magnetization orientation of the readout layer changed gradually from in-plane to out-of-plane with the rise of the temperature. Theoretical analysis explained the experimental results successfully. (c) 2005 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The output spectrum of Yb-doped double-clad fiber superfluorescent source (SFS) is tailored by placing a broadband dichroic mirror in the pump end of conventional single-pass forward configuration, which constitutes double-pass forward configuration. The 3 dB bandwidth is increased from I I to 42 nm. A maximum output SFS power of 2.12 W and a slope efficiency of 43.2% are obtained. The double-clad fiber is 25 in and the pump power is adequate to saturate the fiber as far as the feedback-induced lasing appears. (c) 2004 Elsevier Ltd. All rights reserved.