996 resultados para dose optimization


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background/Aim: Cocktail approach is generally preferred to individual administration of probes in order to characterize the activity of multiple enzymes. However, cocktail strategy has several drawbacks such as drug-drug interactions, tolerability and toxicity. Hence, there is a need to develop cocktails using low doses of probes. Our aim was to investigate whether the simultaneous oral administration of microdoses of midazolam (MDZ) and dextromethorphan (DEM) can be used to assess the simultaneous activities of CYP3A and CYP2D6. Methods: As part of a 5 arm randomized cross-over control trial on the analgesic efficacy of oxycodone, ten healthy young non-smoking males received the following combinations of drugs: Quinidine (Q)+ ketoconazole (K) or Q+placebo (P) or K+P or P+P. In all cases MDZ (0.075 mg) and DEM (2.5 mg) were administrated 1 hour after Q, K or P. CYP2D6 and CYP3A activities were determined after urine collection during 8 hours (ratio DEM/DOR), and a blood sample (EDTA) after 30 min (ratio 1-OH-MDZ/MDZ). DEM and DOR analysis was performed using LC-fluorescence. MDZ and 1-OH-MDZ determination was performed using GC-MS. Allele's variants of CYP2D6 were detected using the AmpliChipTMCYP450 (Roche). Results: CYP2D6 genotype predicted 1 poor (PM), 1 intermediate (IM), 7 extensive (EM) and 2 ultra rapid (UM) metabolizers. A good correlation was obtained between the predicted and the measured phenotypes except for 1 EM phenotyped as UM. Two duplications for alleles *41/*41xN and *1/*2xN were detected and the two volunteers were phenotyped as UM. A potent inhibition of CYP2D6 or CYP3A4 was obtained when Q or K were used. Mean metabolic ratio DEM/DOR in P and K groups were 0.015 (±0.028) and 0.015 (±0.019). It significantly increased in Q and QK groups (0.668 (±0.676) and 0.743 (±1.038)). Mean 1-OH-MDZ/MDZ in P, Q were 2.73 (±1.05) and 2.55 (±1.40) while it significantly decreased in K and QK groups (0.11 (±0.05), 0.10 (±0.05)). Moreover, there were no statistically significant differences between QK and K sessions for CYP3A and between QK and Q for CYP2D6 which indicate that there is no interaction between the two metabolic pathways. Conclusion: Simultaneous assessment of CYP3A and CYP2D6 activities can be obtained by low oral doses (micro-cocktail) of MDZ and DEM. Specific inhibitors such as Q or K modulates selectively CYP2D6 or CYP3A activities.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Our docking program, Fitted, implemented in our computational platform, Forecaster, has been modified to carry out automated virtual screening of covalent inhibitors. With this modified version of the program, virtual screening and further docking-based optimization of a selected hit led to the identification of potential covalent reversible inhibitors of prolyl oligopeptidase activity. After visual inspection, a virtual hit molecule together with four analogues were selected for synthesis and made in one-five chemical steps. Biological evaluations on recombinant POP and FAPα enzymes, cell extracts, and living cells demonstrated high potency and selectivity for POP over FAPα and DPPIV. Three compounds even exhibited high nanomolar inhibitory activities in intact living human cells and acceptable metabolic stability. This small set of molecules also demonstrated that covalent binding and/or geometrical constraints to the ligand/protein complex may lead to an increase in bioactivity.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction: 700 to 1000 UI Vitamin D/day prevent 20% of fall and fracture. Higher dosage could prevent other health problems, such as immune diseases. Adherence to oral daily vitamin D supplementation is low. There is no guideline on how to supplement patients with rheumatic diseases. We evaluated if 1-2 dose(s) of 300'000 UI oral vitamin D3 was enough to reach an optimal level of 25-OH vitamin D in late winter in patients with insufficiency. Methods: During November 2009 (M0) patients attending our Rheumatology Outpatient Clinic had a blood test to measure 25-OH vitamin D. Results were classified as: deficiency <10µg/l, insufficiency 10µg/l to 30µg/l and normal >30µg/l. Patients on daily oral vitamin D3 or who received a single high dose of vitamin D3 in the last 6 months and patients with deficiency or normal results were excluded. Patients included received a single dose of 300'000 IU of oral vitamin D3 and were asked to come back for a blood test for 25-OH vitamin D after 3 (M3) and 6 months (M6). If they were still insufficient at M3, they received a second high dose of 300'000 IU of oral vitamin D3. Results: 292 patients had their level of 25-OH vitamin D determined at M0. 141 patients (70% women) had vitamin D insufficiency (18.5µg/l (10.2-29.1)) and received a prescription for a single dose of 300'000 IU of oral vitamin D3. Men and women were not statistically different in term of age and 25-OH vitamin D level at M0. 124/141 (88%) patients had a blood test at M3. 2/124 (2%) had deficiency (8.1µg/l (7.5-8.7)), 50/124 (40%) normal results (36.7µg/l (30.5-56.5)). 58% (72/124) were insufficient (23.6µg/l (13.8-29.8)) and received a second prescription for 300'000 IU of oral vitamin D3. Of the 50/124 patients who had normal results at M3 and did not receive a second prescription, 36 (72%) had a test at M6. 47% (17/36) had normal results (34.8µg/l (30.3-42.8)), 53% (19/36) were insufficient (25.6µg/l (15.2-29.9)). Out of the 54/72 (75%) patients who received a second prescription, 28/54 (52%) had insufficiency (23.2µg/l (12.8-28.7)) and 26/54 (48%) had normal results (33.8µg/l (30.0-43.7)) at M 6. Discussion: This real life study has shown that one or two oral bolus of 300'000 IU of vitamin D3 in autumn and winter was not enough to completely correct hypovitaminosis D but was a good way of preventing a nadir of 25-OH vitamin D usually observed in spring in a Swiss rheumatologic population.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

INTRODUCTION: Adaptive statistical iterative reconstruction (ASIR) can decrease image noise, thereby generating CT images of comparable diagnostic quality with less radiation. The purpose of this study is to quantify the effect of systematic use of ASIR versus filtered back projection (FBP) for neuroradiology CT protocols on patients' radiation dose and image quality. METHODS: We evaluated the effect of ASIR on six types of neuroradiologic CT studies: adult and pediatric unenhanced head CT, adult cervical spine CT, adult cervical and intracranial CT angiography, adult soft tissue neck CT with contrast, and adult lumbar spine CT. For each type of CT study, two groups of 100 consecutive studies were retrospectively reviewed: 100 studies performed with FBP and 100 studies performed with ASIR/FBP blending factor of 40 %/60 % with appropriate noise indices. The weighted volume CT dose index (CTDIvol), dose-length product (DLP) and noise were recorded. Each study was also reviewed for image quality by two reviewers. Continuous and categorical variables were compared by t test and free permutation test, respectively. RESULTS: For adult unenhanced brain CT, CT cervical myelography, cervical and intracranial CT angiography and lumbar spine CT both CTDIvol and DLP were lowered by up to 10.9 % (p < 0.001), 17.9 % (p = 0.005), 20.9 % (p < 0.001), and 21.7 % (p = 0.001), respectively, by using ASIR compared with FBP alone. Image quality and noise were similar for both FBP and ASIR. CONCLUSION: We recommend routine use of iterative reconstruction for neuroradiology CT examinations because this approach affords a significant dose reduction while preserving image quality.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Recent guidelines recommend initiation of antihypertensive therapy with fixed-dose combinations in high-risk patients because such patients usually need two or more blood pressure (BP)-lowering agents in order to normalize their BP. Agents that block the renin-angiotensin system (ACE inhibitors or angiotensin II receptor antagonists [angiotensin receptor blockers; ARBs]) are preferred for the management of hypertension in most patients exhibiting subclinical target organ damage, or established cardiovascular or renal diseases. Unless contraindicated they should be one of the components of fixed-dose combinations, whereas the other component may be either a calcium channel antagonist or a thiazide diuretic. Fixed-dose combinations containing an ACE inhibitor or ARB plus a calcium channel antagonist appear particularly effective in preventing complications of coronary heart disease.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Since the early 1980s high dose chemotherapy with autologous hematopoietic stem cell support was adopted by many oncologists as a potentially curative option for solid tumors, supported by a strong rationale from laboratory studies and apparently convincing results of early phase II studies. As a result, the number and size of randomized trials comparing this approach with conventional chemotherapy initiated (and often abandoned before completion) to prove or disprove its value was largely insufficient. In fact, with the possible exception of breast carcinoma, the benefit of a greater escalation of dose of chemotherapy with stem cell support in solid tumors is still unsettled and many oncologists believe that this approach should cease. In this article, we critically review and comment on the data from studies of high dose chemotherapy so far reported in adult patients with small cell lung cancer, ovarian cancer, germ cell tumors and sarcomas.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The knowledge of the relationship that links radiation dose and image quality is a prerequisite to any optimization of medical diagnostic radiology. Image quality depends, on the one hand, on the physical parameters such as contrast, resolution, and noise, and on the other hand, on characteristics of the observer that assesses the image. While the role of contrast and resolution is precisely defined and recognized, the influence of image noise is not yet fully understood. Its measurement is often based on imaging uniform test objects, even though real images contain anatomical backgrounds whose statistical nature is much different from test objects used to assess system noise. The goal of this study was to demonstrate the importance of variations in background anatomy by quantifying its effect on a series of detection tasks. Several types of mammographic backgrounds and signals were examined by psychophysical experiments in a two-alternative forced-choice detection task. According to hypotheses concerning the strategy used by the human observers, their signal to noise ratio was determined. This variable was also computed for a mathematical model based on the statistical decision theory. By comparing theoretical model and experimental results, the way that anatomical structure is perceived has been analyzed. Experiments showed that the observer's behavior was highly dependent upon both system noise and the anatomical background. The anatomy partly acts as a signal recognizable as such and partly as a pure noise that disturbs the detection process. This dual nature of the anatomy is quantified. It is shown that its effect varies according to its amplitude and the profile of the object being detected. The importance of the noisy part of the anatomy is, in some situations, much greater than the system noise. Hence, reducing the system noise by increasing the dose will not improve task performance. This observation indicates that the tradeoff between dose and image quality might be optimized by accepting a higher system noise. This could lead to a better resolution, more contrast, or less dose.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Ethyl glucuronide (EtG) is a minor and specific metabolite of ethanol. It is incorporated into growing hair, allowing a retrospective detection of alcohol consumption. However, the suitability of quantitative EtG measurements in hair to determine the quantity of alcohol consumed has not clearly been demonstrated yet. The purpose of this study was to evaluate the influence of ethanol dose and hair pigmentation on the incorporation of EtG into rat hair. Ethanol and EtG kinetics in blood were investigated after a single administration of ethanol. Eighteen rats were divided into four groups receiving 0 (control group), 1, 2, or 3g ethanol/kg body weight. Ethanol was administered on 4 consecutive days per week for 3 weeks by intragastric route. Twenty-eight days after the initial ethanol administration, newly grown hair was shaved. Pigmented and nonpigmented hair were analyzed separately by gas chromatography coupled to tandem mass spectrometry. Blood samples were collected within 12h after the ethanol administration. EtG and ethanol blood levels were measured by liquid chromatography coupled to tandem mass spectrometry and headspace gas chromatography-flame ionization detector, respectively. No statistically significant difference was observed in EtG concentrations between pigmented and nonpigmented hair (Spearman's rho=0.95). Thus, EtG incorporation into rat hair was not affected by hair pigmentation. Higher doses of ethanol resulted in greater blood ethanol area under the curve of concentration versus time (AUC) and in greater blood EtG AUC. A positive correlation was found between blood ethanol AUC and blood EtG AUC (Spearman's rho=0.84). Increased ethanol administration was associated with an increased EtG concentration in hair. Blood ethanol AUC was correlated with EtG concentration in hair (Pearson's r=0.89). EtG concentration in rat hair appeared to reflect the EtG concentration in blood. Ethanol was metabolized at a median rate of 0.22 g/kg/h, and the median elimination half-life of EtG was 1.21 h. This study supports that the bloodstream is likely to display a major role in the hair EtG incorporation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND & AIMS: Although the physiological effects of n-3 polyunsaturated fatty acids (n-3PUFA) are generally thought to require several weeks of exposure to allow their incorporation into plasma membranes, intravenous (IV) n-3PUFA attenuate the cardiovascular and neuroendocrine response to stress within 3 h. Whether oral n-3 PUFA exert similar early effects remains unknown. OBJECTIVE: To assess whether acute IV or short term oral n-3PUFA administration reproduces the metabolic effects of long term oral supplements during exercise, and how it relates to their incorporation into platelets and red blood cells (RBC) membranes. DESIGN: Prospective single center open label study in 8 healthy subjects receiving a 3-h infusion of 0.6 g/kg body weight n-3PUFA emulsion, followed one week later by an oral administration of 0.6 g/kg over 3 consecutive days. Maximal power output (cycling exercise), maximal heart rate (HR), blood lactate at exhaustion, and platelet function were measured at baseline and after IV or 3-day oral supplementation; platelet and RBC membrane composition were assessed until 15 days after n-3PUFA administration. RESULTS: Both IV and oral n-3PUFA significantly decreased maximal HR (-6% and -5%), maximal power output (-10%) and peak blood lactate (-47% and -52%) Platelet function tests were unchanged. The EPA and DHA membrane contents of RBC and platelets increased significantly, but only to 1.7-1.9% of fatty acid content. CONCLUSION: The cardiovascular and metabolic effects of n-3 PUFA during exercise occur already within 1-3 days of exposure, and may be unrelated to changes in membranes composition. Effects occur within hours of administration and are unrelated to lipid membrane composition. Trial registered at clinicaltrials.gov as NCT00516178.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: Although several approaches have been already used to reduce radiation dose, CT doses are still among the high doses in radio-diagnostic. Recently, General Electric introduced a new imaging reconstruction technique, adaptive statistical iterative reconstruction (ASIR), allows to taking into account the statistical fluctuation of noise. The benefits of ASIR method were assessed through classic metrics and the evaluations of cardiac structures by radiologists. Methods and materials: A 64-row CT (MDCT) was employed. Catphan600 phantom acquisitions and 10 routine-dose CT examinations performed at 80 kVp were reconstructed with FBP and with 50% of ASIR. Six radiologists then assessed the visibility of main cardiac structures using the visual grading analysis (VGA) method. Results: On phantoms, for a constant value of SD (25 HU), CTDIvol is divided by 2 (8 mGy to 4 mGy) when 50% of ASIR is used. At constant CTDIvol, MTF medium frequencies were also significantly improved. First results indicated that clinical images reconstructed with ASIR had a better overall image quality compared with conventional reconstruction. This means that at constant image quality the radiation dose can be strongly reduced. Conclusion: The first results of this study shown that the ASIR method improves the image quality on phantoms by decreasing noise and improving resolution with respect to the classical one. Moreover, the benefit obtained is higher at lower doses. In clinical environment, a dose reduction can still be expected on 80 kVp low dose pediatric protocols using 50% of iterative reconstruction. Best ASIR percentage as a function of cardiac structures and detailed protocols will be presented for cardiac examinations.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To compare image quality of a standard-dose (SD) and a low-dose (LD) cervical spine CT protocol using filtered back-projection (FBP) and iterative reconstruction (IR). MATERIALS AND METHODS: Forty patients investigated by cervical spine CT were prospectively randomised into two groups: SD (120 kVp, 275 mAs) and LD (120 kVp, 150 mAs), both applying automatic tube current modulation. Data were reconstructed using both FBP and sinogram-affirmed IR. Image noise, signal-to-noise (SNR) and contrast-to-noise (CNR) ratios were measured. Two radiologists independently and blindly assessed the following anatomical structures at C3-C4 and C6-C7 levels, using a four-point scale: intervertebral disc, content of neural foramina and dural sac, ligaments, soft tissues and vertebrae. They subsequently rated overall image quality using a ten-point scale. RESULTS: For both protocols and at each disc level, IR significantly decreased image noise and increased SNR and CNR, compared with FBP. SNR and CNR were statistically equivalent in LD-IR and SD-FBP protocols. Regardless of the dose and disc level, the qualitative scores with IR compared with FBP, and with LD-IR compared with SD-FBP, were significantly higher or not statistically different for intervertebral discs, neural foramina and ligaments, while significantly lower or not statistically different for soft tissues and vertebrae. The overall image quality scores were significantly higher with IR compared with FBP, and with LD-IR compared with SD-FBP. CONCLUSION: LD-IR cervical spine CT provides better image quality for intervertebral discs, neural foramina and ligaments, and worse image quality for soft tissues and vertebrae, compared with SD-FBP, while reducing radiation dose by approximately 40 %.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In order to study the various health influencing parameters related to engineered nanoparticles as well as to soot emitted b diesel engines, there is an urgent need for appropriate sampling devices and methods for cell exposure studies that simulate the respiratory system and facilitate associated biological and toxicological tests. The objective of the present work was the further advancement of a Multiculture Exposure Chamber (MEC) into a dose-controlled system for efficient delivery of nanoparticles to cells. It was validated with various types of nanoparticles (diesel engine soot aggregates, engineered nanoparticles for various applications) and with state-of-the-art nanoparticle measurement instrumentation to assess the local deposition of nanoparticles on the cell cultures. The dose of nanoparticles to which cell cultures are being exposed was evaluated in the normal operation of the in vitro cell culture exposure chamber based on measurements of the size specific nanoparticle collection efficiency of a cell free device. The average efficiency in delivering nanoparticles in the MEC was approximately 82%. The nanoparticle deposition was demonstrated by Transmission Electron Microscopy (TEM). Analysis and design of the MEC employs Computational Fluid Dynamics (CFD) and true to geometry representations of nanoparticles with the aim to assess the uniformity of nanoparticle deposition among the culture wells. Final testing of the dose-controlled cell exposure system was performed by exposing A549 lung cell cultures to fluorescently labeled nanoparticles. Delivery of aerosolized nanoparticles was demonstrated by visualization of the nanoparticle fluorescence in the cell cultures following exposure. Also monitored was the potential of the aerosolized nanoparticles to generate reactive oxygen species (ROS) (e.g. free radicals and peroxides generation), thus expressing the oxidative stress of the cells which can cause extensive cellular damage or damage on DNA.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective The goal of this study was to investigate whether increasing the dose of an angiotensin II receptor blocker (ARB) provides as much benefits as combining the ARB with an angiotensin-converting enzyme inhibitor (ACEI) in terms of blood pressure (BP) control and urinary albumin excretion (UAE) in hypertensive patients with a proteinuria.Methods We enrolled 20 hypertensive patients with proteinuric nephropathies and a reduced renal function in a randomized, 12-month, triple-crossover, prospective, open-label study to compare the effects of a regular dose of losartan (Los 100mg q.d., LOS100) vs. a high dose of losartan (Los 100mg b.i.d., LOS200) vs. losartan 100mg q.d. associated with lisinopril 20 mg q.d. (LOS100 + LIS20). Each treatment was given for 8 weeks with a 4-week initial run-in period and 2 weeks of washout between each treatment phases. 24 h UAE and ambulatory BP were measured during the running phase and at the end of each treatment period.Results Compared to pretreatment, 24 h SBP and DBP were reduced by 10/5 +/- 7/4 mmHg with LOS100 (P=0.023 vs. baseline) and, respectively, 13/6 +/- 12/5 mmHg with LOS200 (P=0.011) and 19/9 +/- 15/8 mmHg with LOS100+LIS20 (P < 0.01). UAE decreased significantly with LOS100 and to an even greater degree with LOS200 and LOS100+LIS20 (P < 0.01 vs. baseline for both and P=0.032, LOS100+LIS20 vs. LOS200). The combination had a greater impact in patients with a high baseline proteinuria as suggested by a nonparallel leftward shift of the relationship between the changes in UAE induced by the combination and those induced by LOS200. The high dose of losartan was better tolerated than the combination.Conclusion Increasing the dose of losartan from 100mg once daily to 100mg twice a day enables to obtain a greater decrease in BP and proteinuria and is better tolerated than combining the ARB with lisinopril, though the high dose appears to be slightly less effective than the combination in patients with a marked proteinuria. J Hypertens 29: 1228-1235 (C) 2011 Wolters Kluwer Health vertical bar Lippincott Williams & Wilkins.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: Late toxicities such as second cancer induction become more important as treatment outcome improves. Often the dose distribution calculated with a commercial treatment planning system (TPS) is used to estimate radiation carcinogenesis for the radiotherapy patient. However, for locations beyond the treatment field borders, the accuracy is not well known. The aim of this study was to perform detailed out-of-field-measurements for a typical radiotherapy treatment plan administered with a Cyberknife and a Tomotherapy machine and to compare the measurements to the predictions of the TPS. MATERIALS AND METHODS: Individually calibrated thermoluminescent dosimeters were used to measure absorbed dose in an anthropomorphic phantom at 184 locations. The measured dose distributions from 6 MV intensity-modulated treatment beams for CyberKnife and TomoTherapy machines were compared to the dose calculations from the TPS. RESULTS: The TPS are underestimating the dose far away from the target volume. Quantitatively the Cyberknife underestimates the dose at 40cm from the PTV border by a factor of 60, the Tomotherapy TPS by a factor of two. If a 50% dose uncertainty is accepted, the Cyberknife TPS can predict doses down to approximately 10 mGy/treatment Gy, the Tomotherapy-TPS down to 0.75 mGy/treatment Gy. The Cyberknife TPS can then be used up to 10cm from the PTV border the Tomotherapy up to 35cm. CONCLUSIONS: We determined that the Cyberknife and Tomotherapy TPS underestimate substantially the doses far away from the treated volume. It is recommended not to use out-of-field doses from the Cyberknife TPS for applications like modeling of second cancer induction. The Tomotherapy TPS can be used up to 35cm from the PTV border (for a 390 cm(3) large PTV).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A large variety of cancer vaccines have undergone extensive testing in early-phase clinical trials. A limited number have also been tested in randomized phase II clinical trials. Encouraging trends toward increased survival in the vaccine arms have been recently observed for 2 vaccine candidates in patients with non-small-cell lung cancer. These have provided the impetus for the initiation of phase III trials in large groups of patients with lung cancer. These vaccines target 2 antigens widely expressed in lung carcinomas: melanoma-associated antigen 3, a cancer testis antigen; and mucin 1, an antigen overexpressed in a largely deglycosylated form in advanced tumors. Therapeutic cancer vaccines aim at inducing strong CD8 and CD4 T-cell responses. The majority of vaccines recently tested in phase I clinical trials show efficacy in terms of induction of specific tumor antigen immunity. However, clinical efficacy remains to be determined but appears limited. Efforts are thus aimed at understanding the basis for this apparent lack of effect on tumors. Two major factors are involved. On one hand, current vaccines are suboptimal. Strong adjuvant agents and appropriate tumor antigens are needed. Moreover, dose, route, and schedule also need optimization. On the other hand, it is now clear that large tumors often present a tolerogenic microenvironment that hampers effective antitumor immunity. The partial understanding of the molecular pathways leading to functional inactivation of T cells at tumor sites has provided new targets for intervention. In this regard, blockade of cytotoxic T-lymphocyte antigen-4 and programmed death-1 with humanized monoclonal antibodies has reached the clinical testing stage. In the future, more potent cancer vaccines will benefit from intense research in antigen discovery and adjuvant agents. Furthermore, it is likely that vaccines need to be combined with compounds that reverse major tolerogenic pathways that are constitutively active at the tumor site. Developing these combined approaches to vaccination in cancer promises new, exciting findings and, at the same time, poses important challenges to academic research institutions and the pharmaceutical industry.