941 resultados para cochlear implant
Resumo:
PURPOSE To systematically appraise whether anti-infective protocols are effective in preventing biologic implant complications and implant loss after a mean observation period ≥ 10 years after loading. MATERIALS AND METHODS An electronic search of Medline via PubMed and Embase via Ovid databases complemented by manual search was conducted up to October 31, 2012. Studies were included provided that they were published in English, German, French, or Italian, and conducted on ≥ 20 partially and fully edentulous patients with dental implants and regular (≥ 1×/year) supportive periodontal therapy (SPT) over a mean observation period ≥ 10 years. Assessment of the identified studies and data extraction were performed independently by two reviewers. Authors were contacted if required. Collected data were reported by descriptive methods. RESULTS The initial electronic search resulted in the identification of 994 titles from Medline via PubMed and 531 titles from Embase via Ovid databases, respectively. After elimination of duplicate titles and exclusion of 60 full-text articles, 143 articles were analyzed, resulting in 15 studies eligible for qualitative analysis. The implant survival rate ranged from 85.7% to 99.2% after a mean observation period ≥ 10 years. One comparative study assessed the effects of regular SPT on the occurrence of biologic complications and implant loss. Overall, regular diagnosis and implementation of anti-infective therapeutic protocols were effective in the management of biological complications and prevention of implant loss. Residual probing depths at the end of active periodontal therapy and development of reinfection during supportive periodontal therapy (SPT) represented a significant risk for the onset of peri-implantitis and implant loss. Comparative studies indicated that implant survival and success rates were lower in periodontally compromised vs noncompromised patients. CONCLUSIONS In order to achieve high long-term survival and success rates of dental implants and their restorations, enrollment in regular SPT including anti-infective preventive measures should be implemented. Therapy of peri-implant mucositis should be considered as a preventive measure for the onset of peri-implantitis. Completion of active periodontal therapy should precede implant placement in periodontally compromised patients.
Resumo:
Owing to its single surgical intervention, immediate implant placement has the advantage of shortening treatment time, and thus positively affects patient morbidity. According to the bone resorption pattern after tooth extraction, bone loss should be anticipated if immediate implant placement is considered. The present case report aims to present a possible treatment option and to demonstrate that a partially edentulous arch may be rehabilitated esthetically by immediate implant placement and by corresponding anticipatory measures.
Resumo:
OBJECTIVE This retrospective observational pilot study examined differences in peri-implant bone level changes (ΔIBL) between two similar implant types differing only in the surface texture of the neck. The hypothesis tested was that ΔIBL would be greater with machined-neck implants than with groovedneck implants. METHOD AND MATERIALS 40 patients were enrolled; n = 20 implants with machined (group 1) and n = 20 implants with a rough, grooved neck (group 2), all placed in the posterior mandible. Radiographs were obtained after loading (at 3 to 9 months) and at 12 to 18 months after implant insertion. Case number calculation with respect to ΔIBL was conducted. Groups were compared using a Brunner-Langer model, the Mann-Whitney test, the Wilcoxon signed rank test, and linear model analysis. RESULTS After the 12- to 18-month observation period, mean ΔIBL was -1.11 ± 0.92 mm in group 1 and -1.25 ± 1.23 mm in group 2. ΔIBL depended significantly on time (P < .001), but not on group. In both groups, mean marginal ΔIBL was significantly less than -1.5 mm. Only insertion depth had a significant influence on the amount of periimplant bone loss (P = .013). Case number estimate testing for a difference between group 1 and 2 with a power of 90% revealed a sample size per group of 1,032 subjects. CONCLUSION ΔIBL values indicated that both implant designs fulfilled implant success criteria, and the modification of implant neck texture had no significant influence on ΔIBL.
Resumo:
OBJECTIVE The cost-effectiveness of cast nonprecious frameworks has increased their prevalence in cemented implant crowns. The purpose of this study was to assess the effect of the design and height of the retentive component of a standard titanium implant abutment on the fit, possible horizontal rotation and retention forces of cast nonprecious alloy crowns prior to cementation. MATERIALS AND METHODS Two abutment designs were examined: Type A with a 6° taper and 8 antirotation planes (Straumann Tissue-Level RN) and Type B with a 7.5° taper and 1 antirotation plane (SICace implant). Both types were analyzed using 60 crowns: 20 with a full abutment height (6 mm), 20 with a medium abutment height (4 mm), and 20 with a minimal (2.5 mm) abutment height. The marginal and internal fit and the degree of possible rotation were evaluated by using polyvinylsiloxane impressions under a light microscope (magnification of ×50). To measure the retention force, a custom force-measuring device was employed. STATISTICAL ANALYSIS one-sided Wilcoxon rank-sum tests with Bonferroni-Holm corrections, Fisher's exact tests, and Spearman's rank correlation coefficient. RESULTS Type A exhibited increased marginal gaps (primary end-point: 55 ± 20 μm vs. 138 ± 59 μm, P < 0.001) but less rotation (P < 0.001) than Type B. The internal fit was also better for Type A than for Type B (P < 0.001). The retention force of Type A (2.49 ± 3.2 N) was higher (P = 0.019) than that of Type B (1.27 ± 0.84 N). Reduction in abutment height did not affect the variables observed. CONCLUSION Less-tapered abutments with more antirotation planes provide an increase in the retention force, which confines the horizontal rotation but widens the marginal gaps of the crowns. Thus, casting of nonprecious crowns with Type A abutments may result in clinically unfavorable marginal gaps.
Resumo:
OBJECTIVES The aim of this case series was to introduce a complete digital workflow for the production of monolithic implant crowns. MATERIAL AND METHODS Six patients were treated with implant-supported crowns made of resin nano ceramic (RNC). Starting with an intraoral optical scan (IOS), and following a CAD/CAM process, the monolithic crowns were bonded either to a novel prefabricated titanium abutment base (group A) or to a CAD/CAM-generated individualized titanium abutment (group B) in premolar or molar sites on a soft tissue level dental implant. Economic analyses included clinical and laboratory steps. An esthetic evaluation was performed to compare the two abutment-crown combinations. RESULTS None of the digitally constructed RNC crowns required any clinical adaptation. Overall mean work time calculations revealed obvious differences for group A (65.3 min) compared with group B (86.5 min). Esthetic analysis demonstrated a more favorable outcome for the prefabricated bonding bases. CONCLUSIONS Prefabricated or individualized abutments on monolithic RNC crowns using CAD/CAM technology in a model-free workflow seem to provide a feasible and streamlined treatment approach for single-edentulous space rehabilitation in the posterior region. However, RNC as full-contour material has to be considered experimental, and further large-scale clinical investigations with long-term follow-up observation are necessary.
Resumo:
PURPOSE To assess the survival outcomes and reported complications of screw- and cement-retained fixed reconstructions supported on dental implants. MATERIALS AND METHODS A Medline (PubMed), Embase, and Cochrane electronic database search from 2000 to September 2012 using MeSH and free-text terms was conducted. Selected inclusion and exclusion criteria guided the search. All studies were first reviewed by abstract and subsequently by full-text reading by two examiners independently. Data were extracted by two examiners and statistically analyzed using a random effects Poisson regression. RESULTS From 4,324 abstracts, 321 full-text articles were reviewed. Seventy-three articles were found to qualify for inclusion. Five-year survival rates of 96.03% (95% confidence interval [CI]: 93.85% to 97.43%) and 95.55% (95% CI: 92.96% to 97.19%) were calculated for cemented and screw-retained reconstructions, respectively (P = .69). Comparison of cement and screw retention showed no difference when grouped as single crowns (I-SC) (P = .10) or fixed partial dentures (I-FDP) (P = .49). The 5-year survival rate for screw-retained full-arch reconstructions was 96.71% (95% CI: 93.66% to 98.31). All-ceramic reconstruction material exhibited a significantly higher failure rate than porcelain-fused-to-metal (PFM) in cemented reconstructions (P = .01) but not when comparing screw-retained reconstructions (P = .66). Technical and biologic complications demonstrating a statistically significant difference included loss of retention (P ≤ .01), abutment loosening (P ≤ .01), porcelain fracture and/or chipping (P = .02), presence of fistula/suppuration (P ≤ .001), total technical events (P = .03), and total biologic events (P = .02). CONCLUSIONS Although no statistical difference was found between cement- and screw-retained reconstructions for survival or failure rates, screw-retained reconstructions exhibited fewer technical and biologic complications overall. There were no statistically significant differences between the failure rates of the different reconstruction types (I-SCs, I-FDPs, full-arch I-FDPs) or abutment materials (titanium, gold, ceramic). The failure rate of cemented reconstructions was not influenced by the choice of a specific cement, though cement type did influence loss of retention.
Resumo:
OBJECTIVE The Short Communication presents a clinical case in which a novel procedure--the "Individualized Scanbody Technique" (IST)--was applied, starting with an intraoral digital impression and using CAD/CAM process for fabrication of ceramic reconstructions in bone level implants. MATERIAL AND METHODS A standardized scanbody was individually modified in accordance with the created emergence profile of the provisional implant-supported restoration. Due to the specific adaptation of the scanbody, the conditioned supra-implant soft tissue complex was stabilized for the intraoral optical scan process. Then, the implant platform position and the supra-implant mucosa outline were transferred into the three-dimensional data set with a digital impression system. Within the technical workflow, the ZrO2 -implant-abutment substructure could be designed virtually with predictable margins of the supra-implant mucosa. RESULTS After finalization of the 1-piece screw-retained full ceramic implant crown, the restoration demonstrated an appealing treatment outcome with harmonious soft tissue architecture. CONCLUSIONS The IST facilitates a simple and fast approach for a supra-implant mucosal outline transfer in the digital workflow. Moreover, the IST closes the interfaces in the full digital pathway.
Resumo:
OBJECTIVE To analyze the precision of fit of implant-supported screw-retained computer-aided-designed and computer-aided-manufactured (CAD/CAM) zirconium dioxide (ZrO) frameworks. MATERIALS AND METHODS Computer-aided-designed and computer-aided-manufactured ZrO frameworks (NobelProcera) for a screw-retained 10-unit implant-supported reconstruction on six implants (FDI positions 15, 13, 11, 21, 23, 25) were fabricated using a laser (ZrO-L, N = 6) and a mechanical scanner (ZrO-M, N = 5) for digitizing the implant platform and the cuspid-supporting framework resin pattern. Laser-scanned CAD/CAM titanium (TIT-L, N = 6) and cast CoCrW-alloy frameworks (Cast, N = 5) fabricated on the same model and designed similar to the ZrO frameworks were the control. The one-screw test (implant 25 screw-retained) was applied to assess the vertical microgap between implant and framework platform with a scanning electron microscope. The mean microgap was calculated from approximal and buccal values. Statistical comparison was performed with non-parametric tests. RESULTS No statistically significant pairwise difference was observed between the relative effects of vertical microgap between ZrO-L (median 14 μm; 95% CI 10-26 μm), ZrO-M (18 μm; 12-27 μm) and TIT-L (15 μm; 6-18 μm), whereas the values of Cast (236 μm; 181-301 μm) were significantly higher (P < 0.001) than the three CAD/CAM groups. A monotonous trend of increasing values from implant 23 to 15 was observed in all groups (ZrO-L, ZrO-M and Cast P < 0.001, TIT-L P = 0.044). CONCLUSIONS Optical and tactile scanners with CAD/CAM technology allow for the fabrication of highly accurate long-span screw-retained ZrO implant-reconstructions. Titanium frameworks showed the most consistent precision. Fit of the cast alloy frameworks was clinically inacceptable.
Resumo:
PURPOSE To evaluate and compare crestal bone level changes and peri-implant status of implant-supported reconstructions in edentulous and partially dentate patients after a minimum of 5 years of loading. MATERIALS AND METHODS All patients who received a self-tapping implant with a microstructured surface during the years 2003 and 2004 at the Department of Prosthodontics, University of Bern, were included in this study. The implant restorations comprised fixed and removable prostheses for partially and completely edentulous patients. Radiographs were taken immediately after surgery, at impression making, and 1 and 5 years after loading. Crestal bone level (BIC) was measured from the implant shoulder to the first bone contact, and changes were calculated over time (ΔBIC). The associations between pocket depth, bleeding on probing (BOP), and ΔBIC were assessed. RESULTS Sixty-one implants were placed in 20 patients (mean age, 62 ± 7 years). At the 5-year follow-up, 19 patients with 58 implants were available. Implant survival was 98.4% (one early failure; one patient died). The average ΔBIC between surgery and 5-year follow-up was 1.5 ± 0.9 mm and 1.1 ± 0.6 mm for edentulous and partially dentate patients, respectively. Most bone resorption (50%, 0.7 mm) occurred during the first 3 months (osseointegration) and within the first year of loading (21%, 0.3 mm). Mean annual bone loss during the 5 years of loading was < 0.12 mm. Mean pocket depth was 2.6 ± 0.7 mm. Seventeen percent of the implant sites displayed BOP; the frequency was significantly higher in women. None of the variables were significantly associated with crestal bone loss. CONCLUSION Crestal bone loss after 5 years was within the normal range, without a significant difference between edentulous and partially dentate patients. In the short term, this implant system can be used successfully for various prosthetic indications.
Resumo:
OBJECTIVE The aim of the present prospective clinical study was to compare patient-reported outcomes for maxillary conventional dentures and maxillary implant-supported dentures. MATERIAL AND METHODS Twenty-one patients (6 women and 15 men) being edentulous in the maxilla and encountering problems with their existing dentures were included. Twelve patients (4 women and 8 men) received a new set of conventional dentures, due to insufficient dentures. In nine patients (2 women and 7 men), the existing dentures were adjusted by means of relining or rebasing. All patients received implant-supported dentures on two retentive anchors. In total, 42 implants were inserted in the anterior maxilla. The participants rated their satisfaction on their existing conventional dentures, 2 months after insertion of new conventional dentures and 2 months after insertion of implant-supported dentures. Thereby, patients responded to questionnaires capturing the oral health impact profile (OHIP) using visual analog scales. Seven domains (functional limitation, physical pain, psychological discomfort, physical, psychological and social disability and handicap) were assessed. Higher scores implied poorer patient satisfaction. In addition, the questionnaire involved the evaluation of cleaning ability, general satisfaction, speech, comfort, esthetics, stability, and chewing ability. Higher scores implied higher patient satisfaction. RESULTS Patient satisfaction significantly increased for implant-supported dentures compared with old dentures in all seven OHIP subgroups, as well as for cleaning ability, general satisfaction, ability to speak, comfort, esthetics, and stability (P < 0.05). The comparison of new conventional dentures and implant-supported dentures revealed a statistically significantly increased satisfaction for functional limitation (difference of 33.2 mm), psychological discomfort (difference of 36.7 mm), physical disability (difference of 36.3 mm), and social disability (difference of 23.5 mm), (P < 0.05). Additionally, general satisfaction, chewing ability, speech, and stability significantly improved in implant-supported dentures (P < 0.05). CONCLUSIONS Within the limits of this study, maxillary dentures retained by two implants provided some significant short-term improvements over conventional dentures in oral- and health-related quality of life.
Resumo:
Objective. To compare hearing and speech understanding between a new, nonskin penetrating Baha system (Baha Attract) to the current Baha system using a skin-penetrating abutment. Methods. Hearing and speech understanding were measured in 16 experienced Baha users. The transmission path via the abutment was compared to a simulated Baha Attract transmission path by attaching the implantable magnet to the abutment and then by adding a sample of artificial skin and the external parts of the Baha Attract system. Four different measurements were performed: bone conduction thresholds directly through the sound processor (BC Direct), aided sound field thresholds, aided speech understanding in quiet, and aided speech understanding in noise. Results. The simulated Baha Attract transmission path introduced an attenuation starting from approximately 5 dB at 1000 Hz, increasing to 20–25 dB above 6000 Hz. However, aided sound field threshold shows smaller differences and aided speech understanding in quiet and in noise does not differ significantly between the two transmission paths. Conclusion. The Baha Attract system transmission path introduces predominately high frequency attenuation. This attenuation can be partially compensated by adequate fitting of the speech processor. No significant decrease in speech understanding in either quiet or in noise was found.
Resumo:
A major component of minimally invasive cochlear implantation is atraumatic scala tympani (ST) placement of the electrode array. This work reports on a semiautomatic planning paradigm that uses anatomical landmarks and cochlear surface models for cochleostomy target and insertion trajectory computation. The method was validated in a human whole head cadaver model (n = 10 ears). Cochleostomy targets were generated from an automated script and used for consecutive planning of a direct cochlear access (DCA) drill trajectory from the mastoid surface to the inner ear. An image-guided robotic system was used to perform both, DCA and cochleostomy drilling. Nine of 10 implanted specimens showed complete ST placement. One case of scala vestibuli insertion occurred due to a registration/drilling error of 0.79 mm. The presented approach indicates that a safe cochleostomy target and insertion trajectory can be planned using conventional clinical imaging modalities, which lack sufficient resolution to identify the basilar membrane.
Resumo:
A tightly attached keratinized mucosa around endosseous dental implants is believed to be protective against peri-implant bone loss. Tension caused by buccal frena and mobile non keratinized mucosa is to avoid. This case report documents the optimization of peri-implant mucosal conditions in the upper and lower jaw. At the time of second stage surgery (re-entry) at submucosally osseointegrated dental implants an enlargement of keratinized mucosa and a thickening of soft tissue was obtained administrating a vestibuloplasty combined by a free gingival graft or a vestibuloplasty combined by an apically moved flap.