952 resultados para chromium


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Several alloys have been used for prosthodontics restorations in the last years. These alloys have a number of metals that include gold, palladium, silver, nickel, cobalt, chromium and titanium and they are used in oral cavity undergo several corrosion. Corrosion can lead to poor esthetics, compromise of physical properties, or increased biological irritation. The objective of this study was evaluated corrosion resistance of two alloys Ni-Cr and Ni-Cr-Ti in three types of mouthwashes with different active ingredients: 0.5g/l cetylpyridinium chloride + 0.05% sodium fluoride, 0.05% sodium fluoride + 0.03% triclosan (with fluor) and 0.12% chlorohexidine digluconate. The potentiodynamic curves were performed by means of an EG&G PAR 283 potentiostat/galvanostat. The counter electrode was a platinum wire and reference electrode was an Ag/AgCl, KCl saturated. Before each experiment, working electrodes were mechanically polished with 600 and 1200 grade papers, rinsed with distilled water and dried in air. All experiments were carried out at 37.0oC in conventional three-compartment double wall glass cell containing mouthwashes. The microstructures of two alloys were observed in optical microscopy. Analysis of curves showed that Ni-Cr alloy was less reactive in the presence of 0.12% chlorohexidine digluconate while Ni-Cr-Ti alloy was more sensitive for others two types of mouthwashes (0.5g/l cetylpyridinium chloride + 0.05% sodium fluoride  and 0.05% sodium fluoride + 0.03% triclosan). This occurred probably due presence of titanium in this alloy. Microstructural analysis reveals the presence of dendritic and eutectic microstructures for NiCr and Ni-Cr-Ti, respectively.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Introduction: As a new alternative in the complementary treatment lasers teem different systems were employed in the decontamination of dental surfaces implants however, some systems have caused significant changes in its surface. Purpose: Analyze by Scanning Electron Microscopy (SEM) the effects of laser irradiation of Er,Cr: YSGG on different surfaces of titanium. Material and method: Study of 20 titanium discs, and 10 Machined Surface (MS) and 10 surfaces treated with acid (AC). The 10 discs with the same treatment were divided into two groups with five units each, the irradiation was performed in powers of 1 W and 2 W. Result: Showed that the irradiation with 1 W of power resulted in no significant morphological changes in the MS-irradiated compared to non-irradiated surfaces. In MS surfaces, minor changes were observed in the increase of 1000× when compared to non-irradiated surface. With 2 W of power, there were no significant morphological changes in the MS, compared to non-irradiated areas. In AC some changes were observed in the increase of X 1000, showing areas of wear suggestive of treatment and some areas with melting point. Conclusion: Considering the results and the parameters used in this study it was concluded that the Er, Cr: YSGG irradiation can be used for the machined surfaces of implants, but in acid-treated surfaces irradiation parameters should be more controlled.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The results of the investigation on Solution Heat Treatment of Plasma Nitrided (SHTPN) precipitation-hardened steel 15-5PH are presented. The layers have been obtained by the plasma nitriding process followed by solution heat treatment at different temperatures. The influence of the solution heat treatment after nitriding on the dissolution process of the nitrided layer has been considered. The nitrided layers were studied by scanning electron microscopy, X-ray microanalysis (EDX), and X-Ray diffraction. Micro-hardness tests of the nitrided layers and solubilized nitrided layers have been carried out and interpreted by considering the processing conditions. It was found that high nitrogen austenitic cases could be obtained after SHTPN of martensitic precipitation-hardened steel (15-5PH). When Solution Heat Treatment (SHT) was performed at 1100 °C, some precipitates were observed. The amount of precipitates significantly reduced when the temperature increased. The EDX microanalysis indicated that the precipitate may be chromium niobium nitride. When the precipitation on the austenite phase occurred in small amount, the corrosion resistance increased in SHTPN specimens and the pit nucleation potential also increased. The best corrosion result occurred for SHT at 1200 °C.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This study evaluated the effect of daily chromium supplementation at growing doses on serum Cr levels in cattle. Sixty Nellore heifers 2 to 5 years old were randomly assigned to one of four groups (15 heifers/group) fed non-fertilized Brachiaria decumbens pasture. In the control group (Gc), the heifers received a mineral mixture without Cr. In the other groups, heifers received 0.59, 1.19 or 2.38 mg Cr+3/animal/day, groups G8,5, G17 and G34, respectively. Blood samples were collected on days 0, 30 and 60. Serum concentration of chromium was determined by graphite furnace atomic absorption spectrophotometer. The chromium source used was the chromium yeast. The results do not support any significant difference (p>0.05) among serum chromium levels of heifers in groups Gc, G8,5, G17 and G34 at a same observation day. Only effect of supplementation time was detected in group G34. In this group there was significant increase (p<0,05) in the concentration serum chromium 60 days after the beginning of the experiment. Concluded Cr yeast can be used as the source of this mineral element for animals and supplementation with 2.38 mg/ cattle/day was the dose that most increased the serum concentration of Cr in Nellore cattle during the experimental period.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Mineral elements are essential to animal health, survival and production because they are part of physiological, structural, catalytic and regulatory organism functions. Therefore, they should be present in diet. However, these minerals when ingested in excessive doses due to errors in balancing mineral supplements and/or complete ration, intake of plants with high mineral concentration, resulting from addition of fertilizers, herbicides, insecticides and fungicides in pasture or tillage where plants and/or grains will be used to feed animals, decomposition of urban and industrial wastes, leaks and accidental spills of pollutants may result in accumulation of toxic mineral elements in the environment poisoning the animals and may lead them to death. However, toxic doses, physiological changes during poisoning, symptoms and mineral concentration in tissues of poisoned animals to confirm diagnosis are not completely known. Thus, this study reviews mineral element doses that some authors considered toxic for animals intake, as its concentration in tissues of poisoned animals and its physiological effects, symptoms, diagnostic procedures and treatment for poisoning by cadmium, lead, copper, chromium, iodine, manganese, molybdenum, selenium and zinc.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Ceramic powders based on Zn3Ga2Ge2O10: Cr3+ X% (X = 0.0; 0.5; 0.75; 1.0) were synthesized by solid-state reaction method. The gallium-zinc germanate doped with chromium presents an interesting property of phosphorescence, that means, it is capable of emitting light when excited by a source of radiation, and such emission remains for some time after stopping the source. For this reason, these materials can be widely applied in night-vision surveillance, (through the use of solar energy, for example), electronic devices screen, emergency routes signals, control panels indicators in dark environments, etc. In this job were considered different amounts of dopant in order to perform a comparison of structural and photoluminescent properties. For that, some analyses were performed on samples, such as XRD, FT-Raman, SEM, UV-vis and photoluminescence measurements (PL). Such analysis allowed to infer that the presence of chromium results in no phase transformation, so that the four compositions have the same set of phases: cubic, rhombohedral and hexagonal. Although the structure was not changed, chromium influences other properties / characteristics of these materials. Examples are: increase of band-gap, decrease of average particle size, small changes in binding energy checked by Raman and especially the increase of photoluminescent property. The chromium ions have great ease in replacing gallium ions in octahedral sites, resulting in emission of light with a wavelength of about 700 nm (infrared region), which is justified by the spin-forbidden 2E 4A2 transition. In other words, chromium is a favorable luminescent center, acting as a trap in the crystal structure, since it imprisons the excitation energy easily and releases it gradually, allowing the phosphorescence. It was observed that the composition ... (Complete abastract click electronic access below)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Ceramic powders based on Zn3Ga2Ge2O10: Cr3+ X% (X = 0.0; 0.5; 0.75; 1.0) were synthesized by solid-state reaction method. The gallium-zinc germanate doped with chromium presents an interesting property of phosphorescence, that means, it is capable of emitting light when excited by a source of radiation, and such emission remains for some time after stopping the source. For this reason, these materials can be widely applied in night-vision surveillance, (through the use of solar energy, for example), electronic devices screen, emergency routes signals, control panels indicators in dark environments, etc. In this job were considered different amounts of dopant in order to perform a comparison of structural and photoluminescent properties. For that, some analyses were performed on samples, such as XRD, FT-Raman, SEM, UV-vis and photoluminescence measurements (PL). Such analysis allowed to infer that the presence of chromium results in no phase transformation, so that the four compositions have the same set of phases: cubic, rhombohedral and hexagonal. Although the structure was not changed, chromium influences other properties / characteristics of these materials. Examples are: increase of band-gap, decrease of average particle size, small changes in binding energy checked by Raman and especially the increase of photoluminescent property. The chromium ions have great ease in replacing gallium ions in octahedral sites, resulting in emission of light with a wavelength of about 700 nm (infrared region), which is justified by the spin-forbidden 2E 4A2 transition. In other words, chromium is a favorable luminescent center, acting as a trap in the crystal structure, since it imprisons the excitation energy easily and releases it gradually, allowing the phosphorescence. It was observed that the composition ... (Complete abastract click electronic access below)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The contribution of wastewater from a tannery industry to the pollution of a stream was investigated. The main parameters studied were biochemical oxygen demand, chemical oxygen demand, chromium, dissolved oxygen, fecal and total conforms, nitrogen, oils and greases, pH, phosphorous, sulfides, suspended solids, turbidity, and volatile solids. Three sampling points were located: (I) at the discharge point of tannery wastewater, (2) 50 m upstream, and (3) 80 m downstream of discharge point. Also was investigated the pollution at the stream source.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: This study compared the maintenance of tightening torque in different retention screw types of implant-supported crowns. Materials and Methods: Twelve metallic crowns in UCLA abutments cast with cobalt-chromium alloy were attached to external hexagon osseointegrated implants with different retention screws: group A: titanium alloy retention screw; group B: gold alloy retention screw with gold coating; group C: titanium alloy retention screw with diamond-like carbon film coating; and group D: titanium alloy retention screw with aluminum titanium nitride coating. Three detorque measurements were obtained after torque insertion in each replica. Data were evaluated by analysis of variance (ANOVA), Tukey's test (P < 0.05), and t test (P < 0.05). Results: Detorque value reduced in all groups (P < 0.05). Group A retained the highest percentage of torque in comparison with the other groups (P < 0.05). Groups B and D retained the lowest percentage of torque without statistically significant difference between them (P < 0.05). Conclusions: All screw types exhibited reduction in the detorque value. The titanium screw maintained the highest percentage of torque whereas the gold-coated screw and the titanium screw with aluminum titanium nitride coating retained the lowest percentage. (Implant Dent 2012;21:46-50)