978 resultados para backstepping control concept


Relevância:

20.00% 20.00%

Publicador:

Resumo:

INTRODUCTION: In Mexico, breast cancer (BC) is one of the main causes of cancer deaths in women, with increasing incidence and mortality in recent years. Therefore, the aim of the study is identify possible risk factors related to BC. METHODS: An epidemiological study of hospital cases of BC and controls with cervical uterine cancer (CUCA) was carried out at eight third level concentration hospitals in Mexico City. The total of 353 incident cases of BC and 630 controls with CUCA were identified among women younger than 75 years who had been residents of the metropolitan area of Mexico City for at least one year. Diagnosis was confirmed histologically in both groups. Variables were analyzed according to biological and statistical plausibility criteria. Univariate, bivariate and multivariate analyses were carried out. Cases and controls were stratified according to the menopausal hormonal status (pre and post menopause). RESULTS: The factors associated with BC were: higher socioeconomic level (OR= 2.77; 95%CI = 1.77 - 4.35); early menarche (OR= 1.32; 95%CI= 0.88 - 2.00); old age at first pregnancy (>31 years: OR= 5.49; 95%CI= 2.16 - 13.98) and a family history of BC (OR= 4.76; 95% CI= 2.10 - 10.79). In contrast, an increase in the duration of the breastfeeding period was a protective factor (>25 months: OR= 0.38; 95%CI= 0.20 - 0.70). CONCLUSIONS: This study contributes to the identification of risk factors for BC described in the international literature, in the population of Mexican women. Breastfeeding appears to play an important role in protecting women from BC. Because of changes in women`s lifestyles, lactation is decreasing in Mexico, and young women tend not to breastfeed or to shorten the duration of lactation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

INTRODUCTION: At a time when a great number of diseases can be prevented by changing one's habits and life style, investigations have focused on understanding what adults and children believe to be desirable health practices and uncovering the factors associated with successful adherence to such practices. For these, causal attributions for health and illness were investigated among 96 Brazilian elementary school students. METHODS: Ninety six subjects, aged 6 to 14, were interviewed individually and their causal attributions were assessed through 14 true-false items (e.g. people stay well [healthy] because they are lucky). The relationship between the children's causal attributions and demographic characteristics were also examined. RESULTS: Overall, the results were consistent with previous researches. "Taking care of oneself" was considered the most important cause of good health. "Viruses and germs" and "lack of self-care" were the most selected causes of illness. Analyses revealed significant relationship between subjects' causal attribution and their age, school grade level, socioeconomic status and gender. CONCLUSIONS: The study findings suggest that there may be more cross-cultural similarities than differences in children's causal attributions for health and illness. Finding ways to help individuals engage in appropriate preventive-maintenance health practices without developing an exaggerated notion that the individuals can control their own health and illness is a challenge which remains to be addressed by further research.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: Selecting controls is one of the most difficult tasks in the design of case-control studies. Hospital controls may be inadequate and random controls drawn from the base population may be unavailable. The aim was to assess the use of hospital visitors as controls in a case-control study on the association of organochlorinated compounds and other risk factors for breast cancer conducted in the main hospital of the "Instituto Nacional de Câncer" -- INCA (National Cancer Institute) in Rio de Janeiro (Brazil). METHODS: The study included 177 incident cases and 377 controls recruited among female visitors. Three different models of control group composition were compared: Model 1, with all selected visitors; Model 2, excluding women visiting relatives with breast cancer; and Model 3, excluding all women visiting relatives with any type of cancer. Odds ratios (OR) and 95% confidence intervals were calculated to test the associations. RESULTS: Age-adjusted OR for breast cancer associated with risk factors other than family history of cancer, except smoking and breast size, were similar in the three models. Regarding family history of all cancers, except for breast cancer, there was a decreased risk in Models 1 and 2, while in Model 3 there was an increased risk, but not statistically significant. Family history of breast cancer was a risk factor in Models 2 and 3, but no association was found in Model 1. In multivariate analysis a significant risk of breast cancer was found when there was a family history of breast cancer in Models 2 and 3 but not in Model 1. CONCLUSIONS: These results indicate that while investigating risk factors unrelated to family history of cancer, the use of hospital visitors as controls may be a valid and feasible alternative.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objetivos: Pretende-se verificar as modificações neuromotoras após uma intervenção baseada no conceito de Bobath ao nível dos ajustes posturais durante o alcance funcional dos membros superiores, em três crianças com paralisia cerebral. Pretende-se também, verificar o efeito desta abordagem nas atividades e participação, bem como destacar os aspetos individuais das mesmas crianças com a capacidade de mudança após a intervenção. Metodologia: A avaliação foi realizada antes e três meses após a intervenção em fisioterapia segundo o conceito de Bobath. Optou-se por um registo observacional com uma Máquina Fotográfica Digital, um sistemas de Câmaras de Vídeo, uma Plataforma de Forças e, utilizaram-se ainda instrumentos como o Gross Motor Functional Measure– versão 88 itens, o Gross Motor Function Classification System, o Teste de Alcance Funcional Modificado e a ferramenta, Classificação Internacional de Funcionalidade, Incapacidade e Saúde – crianças e jovens. Resultados: Verificou-se um progresso nos ajustes posturais e na funcionalidade em geral, o que se repercutiu na restrição da participação e na limitação da actividade. A postura na posição de sentado, o deslocamento do centro de pressão, a capacidade de deslocamento no sentido anterior, bem como as capacidades motoras grosseiras modificaram-se em todas as crianças, tendo a criança B apresentado a maior e a criança A a menor capacidade de mudança após a intervenção. Conclusão: A intervenção segundo o Conceito de Bobath promoveu modificações neuromotoras, o que levaram a uma melhoria da funcionalidade geral, da mobilidade e do controlo postural da criança, refletindo-se nos ajustes posturais durante o alcance funcional dos membros superiores na posição de sentado. Verificou-se ainda, uma melhoria na restrição da participação e na limitação da actividade diária.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectivos: Identificar as alterações no controlo postural do tronco e repercussões na independência funcional de indivíduos com acidente vascular encefálico (AVE), bem como averiguar se ocorreram mudanças a esse nível após a intervenção, baseada na abordagem segundo o Conceito de Bobath. Metodologia: Foram seleccionados para este estudo dois indivíduos com alterações no controlo postural, resultantes de um AVE, em fase aguda. A avaliação foi realizada em dois momentos (M0 e M1), antes e após quatro semanas da realização da intervenção através da análise do movimento, da aplicação da Escala de Avaliação Postural para Pacientes com Sequelas de AVE (PASS), da Escala de Equilíbrio de Berg (EEB), da Escala Modificada de Barthel (BEM), do Teste Timed Up & Go (TUG) e da Classificação Internacional de Funcionalidade, Incapacidade e Saúde (CIF). Resultados: Os scores obtidos em M1 nos vários instrumentos aplicados, bem como a análise de movimento traduzem a evolução favorável no controlo postural do tronco e na independência nas actividades da vida diária (AVD), observada em ambos os casos clínicos. Verificou-se uma evolução mais evidente na EMB e EEB onde o indivíduo A evoluiu na EMB de 51 em M0 para 94 pontos em M1e o indivíduo B de 51 para 89 pontos. Na EEB o indivíduo A progrediu de 22 para 41 pontos e o indivíduo B de 10 para 36 pontos. Conclusão: Os participantes em estudo evidenciaram modificações no controlo postural com repercussões positivas na independência funcional, após a intervenção com base numa abordagem segundo o conceito de Bobath.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introdução: Após lesão do SNC o músculo pode perder a sua variabilidade e flexibilidade, tal como se verifica em indivíduos após AVE. A caracterização do tónus muscular tem sido um indicador a ter em atenção para o diagnóstico clínico. As alterações do tónus podem resultar de uma combinação de alterações neurais, como consequência dos processos inerentes à neuroplasticidade e alterações biomecânicas. Objectivo: Verificar quais as modificações no tónus muscular, segundo a escala de Tardieu, após a aplicação de um programa de reabilitação neuromotora baseado no conceito de Bobath em dois indivíduos com sequelas de AVE. Pretendeu-se também verificar as repercussões nas actividades funcionais. Participantes e métodos: Foram seleccionados dois indivíduos e aplicado um programa de reabilitação, durante onze semanas, e avaliados em dois momentos, antes da intervenção (PRE) e após a intervenção (APÓS). Aplicaram-se vários instrumentos de avaliação, nomeadamente a escala de Tardieu. O programa de reabilitação realizado baseou-se no conceito de Bobath. Resultados: Na escala de Tardieu, foi comum aos dois indivíduos melhorias a nível da qualidade de reacção muscular. Ambos os indivíduos apresentaram melhorias no controlo postural e equilíbrio, que se evidenciaram na CIF. Conclusão: Foi possível observar modificações no tónus muscular após aplicação de um programa de reabilitação e, consequentemente modificações na distribuição da carga na base de suporte, no alinhamento das estruturas articulares e musculares e na marcha. Ao longo da intervenção, observaram-se repercussões positivas em ambos os indivíduos, permitindo a estes realizar as AVDs com menor dificuldade

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introdução: O acidente vascular encefálico (AVE) é uma importante e frequente condição de saúde que se repercute na funcionalidade do indivíduo. No sentido de reabilitar a função perdida, é comum o recurso a intervenções de fisioterapia baseado o conceito de Bobath. Como tal, importa verificar, as modificações no âmbito do controlo postural, através da migração do centro de pressão na base de suporte, face à aplicação de uma intervenção segundo abordagem baseada no conceito de Bobath em dois indivíduos com AVE. Métodos e participantes: Foram recrutados dois indivíduos com diagnóstico de AVE num hospital da zona do grande Porto. Dados referentes ao equilíbrio estático na condição de medição “olhos abertos ou fechados” e “calçado ou descalço” foram obtidos através de plataforma de forças, antes e após uma intervenção baseado no conceito de Bobath durante 13 semanas (M0 e M1). Nestes dois momentos foram ainda avaliados a mobilidade, função cognitiva, participação, equilíbrio através do teste Timed Up & Go (TUG) e Timed Up & Go Modificado (TUGM), e das escalas Mini Mental State Examination (MMSE), Postural Assessment for Stroke Scale (PASS), Escala de Berg (EB) e Índice de Barthel Modificado (IBM). Resultados: Os participantes obtiveram em ambos os momentos pontuação máxima no MMSE. Ambos os indivíduos atingiram o valor máximo no IBM em M1 (Mo: A: 78; B: 65). Ambos os indivíduos aumentaram o score entre M0 e M1, relativamente ao PASS (A: M0:21; M1:33; B: M0: 26; M1:34) e EB (A: M0:48; M1:54; B: M0: 30; M1:50). O tempo de realização do TUG e do TUGM diminuíram entre momentos em ambos os indivíduos (respectivamente: A: 15''13'' a 13''27''; B: 24''13'' a 13''88'' e A: 19''08''' a 13''27''; B: 29''60''' a 17''64'''). A área de deslocação do centro de pressão (CP) variou entre momentos em todas as condições de avaliação, sendo menor na condição “olhos abertos e descalço” em ambos os participantes (“olhos abertos e calçado”: A: M0= 1,364, M1=2,796; B: M0=1,892, M1=2,979; “olhos abertos e descalço”: A: M0= 0,758, M1=0,727; B: M0=3,064, M1=1,952; “olhos fechados e calçado”: A: M0= 2,360, M1=2,998; B: M0=2,232, M1= 4,392; “olhos fechados e descalço”: A: M0= 1,347, M1=2,388; B: M0=1,652, M1= 1,016). O desvio padrão das deslocações anteroposteriores variou entre momentos, sendo tendencialmente maior em M1 e na condição “descalço e olhos abertos”(“olhos abertos e calçado”: A: M0= 0,201, M1=0,500; B: M0=0,252, M1=0,310; “olhos abertos e descalço”: A: M0= 0,118, M1=0,165; B: M0=0,282, M1=0,276; “olhos fechados e calçado”: A: M0= 0,308, M1=0,398; B: M0=0,274, M1= 0,471; “olhos fechados e descalço”: A: M0= 0,158 , M1=0,373; B: M0=0,230, M1= 0,172), o desvio padrão das deslocações médio-lateral seguem a mesma tendência (“olhos abertos e calçado”: A: M0= 0,370 , M1=0,473; B: M0=0,454, M1=0,517; “olhos abertos e descalço”: A: M0= 0,354, M1=0,236 ; B: M0=0,584, M1=0,381; “olhos fechados e calçado”: A: M0= 0,425, M1=0,463; B: M0=0,462, M1= 0,583; “olhos fechados e descalço”: A: M0= 0,475, M1=0,416; B: M0=0,389, M1= 0,342). A velocidade de oscilação na direcção antero – posterior variou entre momentos, sendo tendencialmente menor em M1, em ambos os participantes e em todas as condições de avaliação: “olhos abertos e calçado”: A: M0= 0,886 , M1=0,532; B: M0=2,507, M1=01,072; “olhos abertos e descalço”: A: M0= 2,562, M1=3,815 ; B: M0=4,367, M1=0,262; “olhos fechados e calçado”: A: M0= 2,689, M1=1,757; B: M0=2,821, M1= 0,769; “olhos fechados e descalço”: A: M0= 2,984, M1=2,525; B: M0=4,100, M1= 0,265), a velocidade de oscilação na direcção médio – lateral seguem a mesma tendência para as condições de “olhos abertos e calçado”: A: M0= 6,524 , M1=6,218; B: M0=0,467, M1=0,404; “olhos fechados e calçado”: A: M0= 6,387, M1=1,927; B: M0=0,351, M1= 0,505; mas a velocidade de oscilação aumenta para as condições de “olhos abertos e descalço”: A: M0= 3,108, M1=7,806 ; B: M0=1,150, M1=8,054; “olhos fechados e descalço”: A: M0= 3,444, M1=3,839; B: M0=1,434, M1= 7,891). Conclusão: Entre os dois momentos os indivíduos melhoraram a sua mobilidade, equilíbrio, participação e actividades, potencialmente devido à intervenção baseado no conceito de Bobath.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents a variable speed autonomous squirrel cage generator excited by a current-controlled voltage source inverter to be used in stand-alone micro-hydro power plants. The paper proposes a system control strategy aiming to properly excite the machine as well as to achieve the load voltage control. A feed-forward control sets the appropriate generator flux by taking into account the actual speed and the desired load voltage. A load voltage control loop is used to adjust the generated active power in order to sustain the load voltage at a reference value. The control system is based on a rotor flux oriented vector control technique which takes into account the machine saturation effect. The proposed control strategy and the adopted system models were validated both by numerical simulation and by experimental results obtained from a laboratory prototype. Results covering the prototype start-up, as well as its steady-state and dynamical behavior are presented. (C) 2011 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A new Modular Marx Multilevel Converter, M(3)C, is presented. The M(3)C topology was developed based on the Marx Generator concept and can contribute to technological innovation for sustainability by enabling wind energy off-shore modular multilevel power switching converters with an arbitrary number of levels. This paper solves both the DC capacitor voltage balancing problem and modularity problems of multilevel converters, using a modified cell of a solid-state Marx modulator, previously developed by authors for high voltage pulsed power applications. The paper details the structure and operation of the M(3)C modules, and their assembling to obtain multilevel converters. Sliding mode control is applied to a M(3)C leg and the vector leading to automatic capacitor voltage equalization is chosen. Simulation results are presented to show the effectiveness of the proposed M(3)C topology.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Power converters play a vital role in the integration of wind power into the electrical grid. Variable-speed wind turbine generator systems have a considerable interest of application for grid connection at constant frequency. In this paper, comprehensive simulation studies are carried out with three power converter topologies: matrix, two-level and multilevel. A fractional-order control strategy is studied for the variable-speed operation of wind turbine generator systems. The studies are in order to compare power converter topologies and control strategies. The studies reveal that the multilevel converter and the proposed fractional-order control strategy enable an improvement in the power quality, in comparison with the other power converters using a classical integer-order control strategy. (C) 2010 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Multilevel power converters have been introduced as the solution for high-power high-voltage switching applications where they have well-known advantages. Recently, full back-to-back connected multilevel neutral point diode clamped converters (NPC converter) have been used inhigh-voltage direct current (HVDC) transmission systems. Bipolar-connected back-to-back NPC converters have advantages in long-distance HVDCtransmission systems over the full back-to-back connection, but greater difficulty to balance the dc capacitor voltage divider on both sending and receiving end NPC converters. This study shows that power flow control and dc capacitor voltage balancing are feasible using fast optimum-predictive-based controllers in HVDC systems using bipolar back-to-back-connected five-level NPC multilevel converters. For both converter sides, the control strategytakes in account active and reactive power, which establishes ac grid currents in both ends, and guarantees the balancing of dc bus capacitor voltages inboth NPC converters. Additionally, the semiconductor switching frequency is minimised to reduce switching losses. The performance and robustness of the new fast predictive control strategy, and its capability to solve the DC capacitor voltage balancing problem of bipolar-connected back-to-back NPCconverters are evaluated.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Voltage source multilevel power converter structures are being considered for high power high voltage applications where they have well known advantages. Recently, full back-to-back connected multilevel neutral diode clamped converters (NPC) have been used in high voltage direct current (HVDC) transmission systems. Bipolar back-to-back connection of NPCs have advantages in long distance HVDC transmission systems, but highly increased difficulties to balance the dc capacitor voltage dividers on both sending and receiving end NPCs. This paper proposes a fast optimum-predictive controller to balance the dc capacitor voltages and to control the power flow in a long distance HVDCsystem using bipolar back-to-back connected NPCs. For both converter sides, the control strategy considers active and reactive power to establish ac grid currents on sending and receiving ends, while guaranteeing the balancing of both NPC dc bus capacitor voltages. Furthermore, the fast predictivecontroller minimizes the semiconductor switching frequency to reduce global switching losses. The performance and robustness of the new fast predictive control strategy and the associated dc capacitors voltage balancing are evaluated. (C) 2011 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents a direct power control (DPC) for three-phase matrix converters operating as unified power flow controllers (UPFCs). Matrix converters (MCs) allow the direct ac/ac power conversion without dc energy storage links; therefore, the MC-based UPFC (MC-UPFC) has reduced volume and cost, reduced capacitor power losses, together with higher reliability. Theoretical principles of direct power control (DPC) based on sliding mode control techniques are established for an MC-UPFC dynamic model including the input filter. As a result, line active and reactive power, together with ac supply reactive power, can be directly controlled by selecting an appropriate matrix converter switching state guaranteeing good steady-state and dynamic responses. Experimental results of DPC controllers for MC-UPFC show decoupled active and reactive power control, zero steady-state tracking error, and fast response times. Compared to an MC-UPFC using active and reactive power linear controllers based on a modified Venturini high-frequency PWM modulator, the experimental results of the advanced DPC-MC guarantee faster responses without overshoot and no steady-state error, presenting no cross-coupling in dynamic and steady-state responses.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Although we have many electric devices at home, there are just few systems to evaluate, monitor and control them. Sometimes users go out and leave their electric devices turned on what can cause energy wasting and dangerous situations. Therefore most of the users may want to know the using states of their electrical appliances through their mobile devices in a pervasive way. In this paper, we propose an Intelligent Supervisory Control System to evaluate, monitor and control the use of electric devices in home, from outside. Because of the transferring data to evaluate, monitor and control user's location and state of home (ex. nobody at home) may be opened to attacks leading to dangerous situations. In our model we include a location privacy module and encryption module to provide security to user location and data. Intelligent Supervising Control System gives to the user the ability to manage electricity loads by means of a multi-agent system involving evaluation, monitoring, control and energy resource agents.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

As wind power generation undergoes rapid growth, new technical challenges emerge: dynamic stability and power quality. The influence of wind speed disturbances and a pitch control malfunction on the quality of the energy injected into the electric grid is studied for variable-speed wind turbines with different power-electronic converter topologies. Additionally, a new control strategy is proposed for the variable-speed operation of wind turbines with permanent magnet synchronous generators. The performance of disturbance attenuation and system robustness is ascertained. Simulation results are presented and conclusions are duly drawn. (C) 2010 Elsevier Ltd. All rights reserved.