852 resultados para amine light stabilizers
Resumo:
Background The clinical efficacy of intense pulsed light (IPL) in the treatment of poikiloderma of Civatte (PC) is well documented, but little is known about microscopic changes. Objective To analyze histopathologic findings on the necks of individuals with PC after IPL therapy. Materials and Methods Fourteen patients with PC on the neck underwent three monthly sessions of IPL. Biopsies and clinical photographs were taken before and 60 similar to days after treatment. A dermatopathologist analyzed histopathologic slides stained with hematoxylin and eosin, Masson's trichrome, Verhoeff-van Gieson and Fontana-Masson or processed for CD-34 immunohistochemistry. The slides also underwent digital image analysis. Clinical results were based on the analysis of the pictures by three dermatologists and on patient satisfaction. Results Intense pulsed light treatment resulted in more-homogeneous melanin distribution; a greater number of fibroblasts and nonfragmented elastic fibers; and greater density (p similar to=similar to.01), color intensity (p similar to=similar to.02), number and thickness of the collagen bundles. No significant changes in vessels number or diameters were observed. Clinical results were positive in 92.9% of the cases. Conclusion IPL treatment of PC induced a more-homogeneous distribution of melanin and increased nonfragmented elastic fibers, collagen density, and intensity. These changes were related to clinical improvement.
Resumo:
Objective. The aim of this study was to evaluate the rat alveolar socket response to implanted polyethylene tubes filled with a light-cured MTA or Angelus MTA.Study design. Fifty-seven Wistar rats received an implant filled with one of the materials in the dental socket of the right central incisor. After 30, 60, and 90 days, animals were killed, and the right hemimaxillas were removed and processed to be analyzed on light microscopy. After embedding in paraffin, 6-mu m-thick sections were obtained and stained with hematoxylin and eosin. Qualitative and quantitative analyses of the reaction were performed.Results. It was observed that the light-cured MTA presented a similar response compared with Angelus MTA, characterized by the reduction of the chronic inflammatory response and organization of the alveolar bone close to the materials, especially at the 90th day of observation.Conclusions. It was concluded that both materials were well accepted by the alveolar tissue of rats, with the formation of mineralized tissue close to the materials. (Oral Surg Oral Med Oral Pathol Oral Radiol Endod 2010;110:e93-e97)
Resumo:
Introduction: The aim of this study was to evaluate the rat alveolar bone response after the implantation of experimental light-cured mineral trioxide aggregate (MTA) or Angelus MTA (Angelus, Londrina, Parana, Brazil) by histological and fluorescence analysis. Methods: Thirty Wistar Albino rats were divided into three groups. In the control group, empty polyethylene tubes were inserted into the rat alveolar sockets immediately after extraction. In the other groups, the tubes were filled with light-cured MTA or Angelus MTA. Five animals from each group were injected with calcein on day 7, alizarin on day 14, and oxytetracycline on day 21. on day 30, these animals were killed, and the right hemimaxillas were removed and histologically processed. Half of the maxillas were processed and stained with hematoxylin and eosin. The remaining maxillas were processed for fluorescence analysis and stained with Stevenel blue and alizarin red. New bone was histomorphometrically evaluated using a Merz grid. Results: The light-cured MTA presented a similar response when compared with Angelus MTA; it was characterized by a mild inflammatory response and complete bone healing. In the light-cured MTA group, the fluorescence areas were more evident at 21 days, showing an increase in bone formation. However, dystrophic mineralization was observed only with Angelus MTA. Conclusions: It was concluded that both materials present a similar inflammatory response and bone healing, but dystrophic mineralization was observed only with Angelus MTA. (J Endod 2011;37:250-254)
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
The purpose of this study was to evaluate the subcutaneous response of rat connective tissue to light-cure MTA and Angelus MTA. These materials were placed in polyethylene and dentin tubes and implanted into dorsal connective tissue of Wistar rats for 30 and 60 days. The specimens were prepared to be stained with hematoxylin-eosin, Von Kossa, and without stain for polarized light and evaluated in an optic microscope. The Angelus MTA showed a mild inflammatory response at 30 days and none at 60 days, characterized by organized connective tissue, presence of some chronic inflammatory cells, and induction of mineralized tissue formation. Light-cure MTA presented a moderate chronic inflammatory response at 30 days that decreased at 60 days but was more intense than with Angelus MTA and without dystrophic calcifications. It was possible to conclude that light-cure MTA was similar to MTA at 60 days, but it did not stimulate mineralization.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Objective: This study evaluated the influence of light sources and immersion media on the color stability of a nanofilled composite resin. Material and Methods: Conventional halogen, high-power-density halogen and high-power-density light-emitting diode (LED) units were used. There were 4 immersion media: coffee, tea, Coke (R) and artificial saliva. A total of 180 specimens (10 mm x 2 mm) were prepared, immersed in artificial saliva for 24 h at 37 +/- 1 degrees C, and had their initial color measured with a spectrophotometer according to the CIELab system. Then, the specimens were immersed in the 4 media during 60 days. Data from the color change and luminosity were collected and subjected to statistical analysis by the Kruskall-Wallis test (p<0.05). For immersion time, the data were subjected to two-way ANOVA test and Fisher's test (p<0.05). Results: High-power-density LED (Delta E=1.91) promoted similar color stability of the composite resin to that of the tested halogen curing units (Jet Lite 4000 plus - Delta E=2.05; XL 3000 - Delta E=2.28). Coffee (Delta E=8.40; Delta L=-5.21) showed the highest influence on color stability of the studied composite resin. Conclusion: There was no significant difference in color stability regardless of the light sources, and coffee was the immersion medium that promoted the highest color changes on the tested composite resin.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
This study evaluated the influence of light-curing units (LCUs) on Knoop microhardness (KHN) of different composite resins formulations. Four LCUs, one Quartz-Tungsten-Halogen (QTH) for 20 s, one Argon-Ion-Laser (AL) for 10 s, one Plasma-Arc-Curing (PAC) for 9 s, and one Light-Emitting-Diode (LED) for 20 s, and three composite resins, nanofill and easy cure (Filtek (TM) Supreme), microhybrid and medium cure (Herculite XRV), and microfill and difficult cure (Heliomolar) were used. Discs (4 x 2 mm(2)) of each composite resin were divided in 12 Groups and KHN was measured at the top (T) and bottom (B) surfaces. Data were analyzed using two-way ANOVA and Tukey's test (p < 0.05). Top presented significantly higher KHN than bottom surface for all composite resins and LCUs tested. Statistical significant differences were observed among the LCUs. At the bottom surface QTH and LED presented higher KHN than PAC and LA. However, at the top surface PAC and LA presented similar results than QTH for nanofill and microhybrid composite resins. Different LCUs play an important effect on Knoop microhardness and the composite resin formulations were significant factor on the photosensitivity.
Resumo:
The purpose of this study was to evaluate the polymerization effectiveness of a composite resin (Z-250) utilizing microhardness testing. In total, 80 samples with thicknesses of 2 and 4 mm were made, which were photoactivated by a conventional halogen light-curing unit, and light-curing units based on LED. The samples were stored in water distilled for 24 h at 37C. The Vickers microhardness was performed by the MMT-3 microhardness tester. The microhardness means obtained were as follows: G1, 72.88; G2, 69.35; G3, 67.66; G4, 69.71; G5, 70.95; G6, 75.19; G7, 72.96; and G8, 71.62. The data were submitted to an analysis of variance (ANOVA's test), adopting a significance level of 5%. The results showed that, in general, there were no statistical differences between the halogen and LED light-curing units used with the same parameters.