969 resultados para acousto-optic
Resumo:
Objective. Meningeal melanocytoma generally occurs in the posterior fossa. Orbital manifestation is rarely encountered.Methods. A thirty-five year-old man presented with progressive proptosis of his right eye. Computed tomography (CT) and Magnetic Resonance Imaging (MRI) of the brain showed an expansive intraconal mass lesion occupying the superior orbital compartment, the entire orbital apex, and the optic foramen. Histological analysis and Immunohistochical staining for S-100 and HMB-45 monoclonal antibodies confirmed melanocytoma.Findings. Microsurgical removal was accomplished through a fronto-orbital craniotomy. Chemotherapy and irradiation followed the initial intervention. The patient returned for follow up two years after surgery, complaining of headache and right visual loss. A subfrontal tumor with massive edema was found on follow up CT scan.Interpretation. Meningeal melanocytomas are rare benign pigmented tumors of the central nervous system. They are predominant in the posterior fossa and spinal cord and frequently mistaken for melanomas, especially on frozen sections. Orbital presentation is rare. The natural history is poorly defined.
Resumo:
The laser Welding process was introduced into dentistry by the end of the 1980s, resulting on a great impulse to that area with the development of cheaper and smaller equipment, using simpler technique. This allowed greater use of that process on the confection of prostheses compared to the brazing process since the heat source for that process is a concentrated light beam of high power, which minimizes distortion problems on the prosthetic pieces. Ag-Pd-Au-Cu alloy used on the confection of dental implant prostheses was observed before and after subjection to the laser welding process. The microstructure was analyzed with the. use of optic microscopy and the corrosion resistance was studied by the traditional electrochemical techniques and by electrochemical impedance, under environmental conditions simulating the aggressiveness found in the mouth cavity. A structural change was detected on the weld area, which presented a refined microstructure deriving from the high-speed cooling. The base metal out of the weld area presented a fusion coarse microstructure. The electrochemical essays showed differences on the potentiodynamic polarization behavior in both weld and metal base areas, indicating superior corrosion resistance in the weld area. The impedance spectra were characterized by capacitive distorted components, presenting linear impedance in the low frequencies area. (C) 2002 Elsevier B.V. B.V. All rights reserved.
Resumo:
A sensitive and affordable approach is described for the in-situ measurement of ambient formaldehyde. Air is sampled around a 100 microliter aqueous drop containing 3-methyl-2-benzothiazoline hydrazone. After a desired period of sampling (typ. 5 min) and a waiting period of 10 min for the reaction to be completed, a second reagent (FeCl3) is added to the drop by means of a conjoined conduit. A blue product is formed and is read after an additional 10 min of reaction by a fiber-optic/light emitting diode based photodetector. A fresh drop is then formed and the process begins anew. As demonstrated here, the limit of detection is similar to 6.25 mu g m(-3) HCHO but can be significantly improved by using longer sampling times and a sampling rate higher than 100 mi min(-1) used in most of this work. This is the first example of a chromogenic drop sensor that utilizes sequential reagent addition.
Resumo:
This work presents for the first time to our knowledge the fabrication and characterization of rib waveguides produced with PbO-GeO2 (PGO) thin films. The target was manufactured using pure oxides ( 60 PbO-40 GeO2, in wt%) and amorphous thin films were produced with the RF sputtering technique. PGO thin films present small absorption in the visible and in the near infrared and refractive index of similar to 2.0. The definition of the rib waveguide structure was made using conventional optical lithography followed by plasma etching, performed in a Reactive Ion Etching (RIE) reactor. Light propagation mode in the waveguide structure was analyzed using integrated optic simulation software. Optical loss measurements were performed to determine the propagation loss at 633 nm, for ribs with height of 70 nm and width of 3-5 mu m; experimental values around 2 dB/cm were found for the propagation loss and confirmed the theoretical calculations. The results obtained demonstrate that PGO thin films are potential candidates for application in integrated optics. Published by Elsevier B.V.
Resumo:
Vector potential of ants in mechanic dissemination of helminthes in a cat rescue center was analyzed in this study. Ants walking over cat's food and feces were collected and conditioned in distilled water. Cat feces were collected too. Ants were identified and the water where they were conditioned was observed on optic microscope. It was made the simple sedimentation technique to analyze feces. The results show that ants species Pheidole and Paratrechina can be potential vectors of nematode eggs, mainly Ascaridida, Toxocaridae.
Resumo:
PurposeUltrasonographic evaluation of the eye is a relatively recent addition to routine ophthalmic diagnostics in small animal ophthalmology. Some parameters for ophthalmic biometry have been established. There are few studies in clinical avian ophthalmology that describe ultrasound images of eye in some nocturnal avian species and in other birds that do not belong to the Brazilian fauna, but the psittacine family is not represented. The purpose of this study was to describe the following measurements: the distances between cornea and anterior lens capsule (D1) between the anterior and posterior lens capsule (D2), between posterior lens capsule and optic papilla (D3) and the axial length.MethodSixty four transpalpebral ocular ultrasound examinations were performed on 32 Blue fronted Amazon parrots (Amazona aestiva) with no history of previous ophthalmic disease.Result and DiscussionThe measurements were taken in sagital planes using a 10 MHz linear probe without a standoff pad. The mean values for the left eye were; D1 0.17 +/- 0.03 cm, D2 0.35 +/- 0.02 cm, D3 0.73 +/- 0.04 cm and the axial length 1.26 +/- 0.06 cm. In the right eye D1 0.17 +/- 0.02 cm, D2 0.34 +/- 0.02 cm, D3 0.74 +/- 0.03 cm and the axial length 1.25 +/- 0.05 cm. No significant statistical difference was observed among the birds or between the left and right eye. The description of these parameters will allow the veterinary practitioner to evaluate the structural changes that specific diseases may cause in these animals.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Study model: observacional, retrospective. Objective: to determine the frequence of the ametropic errors and other ocular problems in children with 2 to 8 year-old at Piracicaba - SP. Patients and Method: During the school year of 2000, 1001 children enrolled at the public schools of Piracicaba - SP, age ranged from 2 to 8 years old, were referred to complete ophthalmological exam. Visual acuity was previously determined using Snellen chart, applied by school teachers. Those children presenting visual acuity equal or less than 0.8, visual complaints or visual disorders were selected to appointment. Results: 51 children (5.09%) did not attended to examination. 950 children were submitted to complete ophthalmological exam. Ametropic errors were found 70.84% of the children. The most prevalent refractive errors were Hypermetropic Astigmatism (49.62%) and Hypermetropia (32,98%). Anisometropia was found in 1.78% children. Other ocular disabilities accounted for 10.21% of the examined children, such as strabismus (3.36%), eyelid changes, allergic conjunctivitis, congenital dacryostenosis, optic atrophy, corioretinitis and congenital glaucoma. Conclusion: The frequence of ocular problems observed let us to conclude the screening programs are valid surveys on decreasing rates of preventable blindness in our country.
Resumo:
Room-temperature photoluminescence (PL) was observed in undoped and 2 mol% Cr-, Al- and Y-doped amorphous SrTiO3 thin films. Doping increased the PL, and in the case of Cr significantly reduced the associated PL wavelength. The optical bandgaps, calculated by means of UV-vis absorption spectra, increased with crystallinity and decreased with the doping level. It was considered that yttrium and aluminum substituted Sr2+, whereas chromium replaced Ti4+. It is believed that luminescence centers are oxygen-deficient BO6 complexes, or the same centers with some other defects, such as oxygen or strontium vacancies, or BO6 complexes with some other defects placed in their neighborhood. The character of excitation and the competition for negatively charged non-bridging oxygen (NBO) among numerous types of BO6 defect complexes in doped SrTiO3 results in various broadband luminescence peak positions. The results herein reported are an indicative that amorphous titanates are sensitive to doping, which is important for the control of the electro-optic properties of these materials. The probable incorporation of Cr into the Ti site suggests that the existence of a double network former can lead to materials displaying a more intense photoluminescence.
Resumo:
Purpose: To study the effects of two drugs (captopril and propranolol) used in the treatment of systemic hypertension, on the intraocular pressure (IOP) of anesthetized dogs. Methods: 24 dogs, divided into 3 groups of 8 each. In the first group, 1.5 mg/kg IV of captopril (an angiotensin converting enzyme inhibitor) was administered. In the second group, 1.5 mg/kg IV of propranolol (a beta-blocker) was administered. The third group was the control. IOP and blood pressure (BP) were measured by manometry. The perfusion pressure was calculated by the difference between BP and IOP (BP-IOP). The parameters were studied at 6 moments (0, 10, 30, 60, 90 and 120 minutes). Results: There was significant reduction of IOP (p<0.05) with captopril and propranolol, without difference between the drugs. With captopril the BP and PP decreased markedly at 10 and 30 minutes. With propranolol there was no reduction of BP or PP. Conclusions: Captopril and propranolol reduced IOP. However, the marked reduction of BP, and consequently of PP caused by captopril may be undesirable for irrigation of the optic nerve.
Resumo:
Adult leaves of Melissa officinalis L. (Lamiaceae) harvested during the time of budding had been used in the study of the leaf anatomy in the identification of the secretory structures. The material was fixed in FAA 50%, dehydrated in alcoholic series (ethyl), infiltrated in paraffin, sectioned at 13 mm, staining and later analyzed through optic microscopy. Also it was carried through a study in gaseous chromatography for attainment of the rude essential oil. Analyses of transversal sections of the leaf of Melissa officinalis, has identified the presence of two types of trichomes secretory: peltate and capitate, beyond the presence of trichome tector. Trichome capitate, identified in literature as (type I), presents variations in its morphology in relation to the cells number stalk and the head secretory cells number. The chromatographic analysis of the essential oil identified the presence of monoterpenes, in two major components, responsible for more than 87.8% of the relative composition in the rude oil, beyond sesquiterpenes in smaller proportions.
Resumo:
Pulp capping is a procedure that comprises adequate protection of the pulp tissue exposed to the oral environment, aiming at the preservation of its vitality and functions. This study evaluated the response of the dental pulps of dog teeth to capping with mineral trioxide aggregate (MTA) or calcium hydroxide P.A. For that purpose, 37 teeth were divided into two groups, according to the capping material employed. Two dogs were anesthetized and, after placement of a rubber dam, their pulps were exposed in a standardized manner and protected with the experimental capping materials. The cavities were then sealed with resin-modified glass ionomer cement and restored with composite resin. After sixty days, the animals were killed and the specimens were processed in order to be analyzed with optic microscopy. It was observed that MTA presented a higher success rate compared to calcium hydroxide, presenting a lower occurrence of infection and pulp necrosis.
Resumo:
Objective: To describe the normal bony orbital structure of the large fruit-eating bat (Artibeus lituratus) with emphasis on a unique intraorbital bony structure previously not described in the literature. Procedures: The bony anatomy of the orbital cavity was studied on dissected skulls of large fruit-eating bats. The anatomic description of a unique intraorbital spine was made while studying the bony orbit of macerated skulls. Additional observations were made on dissected formalin-fixed whole heads. Both procedures were performed under a stereo dissecting microscope, using ×2-4-magnification. A histologic analysis of soft tissues surrounding this cylindrical bony structure was performed using cross and longitudinal oblique sections from decalcified whole heads, which had been fixed in formalin. Additionally, biometric measurements and a histomorphometric analysis were performed. Results and conclusions: An intraorbital cylindrical osseous structure measuring 3.96 ± 0.68 mm in length and 155.62 ± 14.03 μm in diameter was observed in the large fruit-eating bat (A. lituratus), creating a unique orbital structural design among mammals. We suggest the name optic spine of the alisphenoid bone. The anatomic, biometric and histologic characterization of this element might contribute to a further understanding of the dynamics of bat vision and the sort of factors that influenced evolution of the visual system of microbats. The authors hope that the documentation of this distinctive anatomic feature will also expand the debate about the phylogenetic analysis of the relationship among bat species in the near future. © 2007 American College of Veterinary Ophthalmologists.
Resumo:
Nonlinear (NL) optical properties of antimony oxide based glasses (AG) were characterized for excitation wavelengths from 800 to 1600 m. The NL refractive indices, n2, and the two-photon absorption (TPA) coefficient, β, have been evaluated using the Z-scan technique. Values of n2≈ 10-15 - 10-14 cm2/W of electronic origin were measured and negligible TPA coefficients (β < 0.003 cm/GW) were determined. The response time of the nonlinearity is faster than 100 fs as determined using the Kerr shutter technique. The figure-of-merit usually considered for all-optical switching, T = 2βλ/n2 , indicates that AG are very good materials for ultrafast switches at telecom wavelengths. © 2007 IEEE.