990 resultados para X-ray powder diffractometry
Resumo:
X-ray emission from a comet was observed for the first time in 1996. One of the mechanisms believed to be contributing to this surprisingly strong emission is the interaction of highly charged solar wind ions with cometary gases. Reported herein are total absolute charge-exchange and normalized line-emission (X-ray) cross sections for collisions of high-charge state (+3 to +10) C, N, O, and Ne ions with the cometary species H2O and CO2. It is found that in several cases the double charge-exchange cross sections can be large, and in the case of C3+ they are equal to those for single charge exchange. Present results are compared to cross section values used in recent comet models. The importance of applying accurate cross sections, including double charge exchange, to obtain absolute line-emission intensities is emphasized.
Resumo:
Extreme states of matter such as Warm Dense Matter “WDM” and Dense Strongly Coupled Plasmas “DSCP” play a key role in many high energy density experiments, however creating WDM and DSCP in a manner that can be quantified is not readily feasible. In this paper, isochoric heating of matter by intense heavy ion beams in spherical symmetry is investigated for WDM and DSCP research: The heating times are long (100 ns), the samples are macroscopically large (mm-size) and the symmetry is advantageous for diagnostic purposes. A dynamic confinement scheme in spherical symmetry is proposed which allows even ion beam heating times that are long on the hydrodynamic time scale of the target response. A particular selection of low Z-target tamper and x-ray probe radiation parameters allows to identify the x-ray scattering from the target material and use it for independent charge state measurements Z* of the material under study.
Resumo:
A novel wide angle spectrometer has been implemented with a highly oriented pyrolytic graphite crystal coupled to an image plate. This spectrometer has allowed us to look at the energy resolved spectrum of scattered x rays from a dense plasma over a wide range of angles ( ~ 30°) in a single shot. Using this spectrometer we were able to observe the temporal evolution of the angular scatter cross section from a laser shocked foil. A spectrometer of this type may also be useful in investigations of x-ray line transfer from laser-plasmas experiments.
Resumo:
Context. The I(15.01 Å)/I(16.78 Å) emission line intensity ratio in Fe xvii has been reported to deviate from its theoretical value
in solar and stellar X-ray spectra. This is attributed to opacity in the 15.01 Å line, leading to a reduction in its intensity, and was
interpreted in terms of a geometry in which the emitters and absorbers are spatially distinct.
Aims. We study the I(15.01 Å)/I(16.78 Å) intensity ratio for the active cool dwarf EV Lac, in both flare and quiescent spectra.
Methods. The observations were obtained with the Reflection Grating Spectrometer on the XMM-Newton satellite. The emission
measure distribution versus temperature reconstruction technique is used for our analysis.
Results. We find that the 15.01 Å line exhibits a significant enhancement in intensity over the optically thin value. To our knowledge,
this is the first time that such an enhancement has been detected on such a sound statistical basis. We interpret this enhancement
in terms of a geometry in which the emitters and absorbers are not spatially distinct, and where the geometry is such that resonant
pumping of the upper level has a greater effect on the observed line intensity than resonant absorption in the line-of-sight.