827 resultados para Urban design and architecture


Relevância:

100.00% 100.00%

Publicador:

Resumo:

XENON is a dark matter direct detection project, consisting of a time projection chamber (TPC) filled with liquid xenon as detection medium. The construction of the next generation detector, XENON1T, is presently taking place at the Laboratori Nazionali del Gran Sasso (LNGS) in Italy. It aims at a sensitivity to spin-independent cross sections of 2 10-47 c 2 for WIMP masses around 50 GeV2, which requires a background reduction by two orders of magnitude compared to XENON100, the current generation detector. An active system that is able to tag muons and muon-induced backgrounds is critical for this goal. A water Cherenkov detector of ~ 10 m height and diameter has been therefore developed, equipped with 8 inch photomultipliers and cladded by a reflective foil. We present the design and optimization study for this detector, which has been carried out with a series of Monte Carlo simulations. The muon veto will reach very high detection efficiencies for muons (>99.5%) and showers of secondary particles from muon interactions in the rock (>70%). Similar efficiencies will be obtained for XENONnT, the upgrade of XENON1T, which will later improve the WIMP sensitivity by another order of magnitude. With the Cherenkov water shield studied here, the background from muon-induced neutrons in XENON1T is negligible.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

M. Verdaguer

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Cleverly designed molecular building blocks provide chemists with the tools of a powerful molecular-scale construction set. They enable them to engineer materials having a predictable order and useful solid-state properties. Hence, it is in the realm of supramolecular chemistry to follow a strategy for synthesizing materials which combine a selected set of properties, for instance from the areas of magnetism, photophysics and electronics. As a successful approach, host/guest solids which are based on extended anionic, homo- and bimetallic oxalato-bridged transition-metal compounds with two-and three-dimensional connectivities have been investigated. In this report, a brief review is given on the structural aspects of this class of compounds followed by a presentation of a thermal and magnetic study for two distinct, heterometallic oxalato-bridged layer compounds.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Urban agriculture is a phenomenon that can be observed world-wide, particularly in cities of devel-oping countries. It is contributing significantly to food security and food safety and has sustained livelihood of the urban and peri-urban low income dwellers in developing countries for many years. Population increase due to rural-urban migration and natural, coupled with formal as well as infor-mal urbanization are competing with urban farming for available space and scarce water resources. A multitemporal multisensoral urban change analysis over the period of 25 years (1982-2007) was performed in order to measure and visualize the urban expansion along the Kizinga and Mzinga valley in the South of Dar es Salaam. Airphotos and VHR satellite data were analyzed by using a combination of a composition of anisotropic textural measures and spectral information. The study revealed that unplanned built-up area is expanding continuously and vegetation covers and agricultural lands decline at a fast rate. The validation showed that the overall classification accuracy varied depending on the database. The extracted built-up areas were used for visual in-terpretation mapping purposes and served as information source for another research project. The maps visualize an urban congestion and expansion of nearly 18% of the total analyzed area that had taken place in the Kizinga valley between 1982 and 2007. The same development can be ob-served in the less developed and more remote Mzinga valley between 1981 and 2002. Both areas underwent fast changes where land prices still tend to go up and an influx of people both from rural and urban areas continuously increase density with the consequence of increasing multiple land use interests.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND Sutureless aortic valve replacement (SU-AVR) is an innovative approach which shortens cardiopulmonary bypass and cross-clamp durations and may facilitate minimally invasive approach. Evidence outlining its safety, efficacy, hemodynamic profile and potential complications is replete with small-volume observational studies and few comparative publications. METHODS Minimally invasive aortic valve surgery and high-volume SU-AVR replacement centers were contacted for recruitment into a global collaborative coalition dedicated to sutureless valve research. A Research Steering Committee was formulated to direct research and support the mission of providing registry evidence warranted for SU-AVR. RESULTS The International Valvular Surgery Study Group (IVSSG) was formed under the auspices of the Research Steering Committee, comprised of 36 expert valvular surgeons from 27 major centers across the globe. IVSSG Sutureless Projects currently proceeding include the Retrospective and Prospective Phases of the SU-AVR International Registry (SU-AVR-IR). CONCLUSIONS The global pooling of data by the IVSSG Sutureless Projects will provide required robust clinical evidence on the safety, efficacy and hemodynamic outcomes of SU-AVR.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Intraoperative laparoscopic calibration remains a challenging task. In this work we present a new method and instrumentation for intraoperative camera calibration. Contrary to conventional calibration methods, the proposed technique allows intraoperative laparoscope calibration from single perspective observations, resulting in a standardized scheme for calibrating in a clinical scenario. Results show an average displacement error of 0.52 ± 0.19 mm, indicating sufficient accuracy for clinical use. Additionally, the proposed method is validated clinically by performing a calibration during the surgery.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The usage of intensity modulated radiotherapy (IMRT) treatments necessitates a significant amount of patient-specific quality assurance (QA). This research has investigated the precision and accuracy of Kodak EDR2 film measurements for IMRT verifications, the use of comparisons between 2D dose calculations and measurements to improve treatment plan beam models, and the dosimetric impact of delivery errors. New measurement techniques and software were developed and used clinically at M. D. Anderson Cancer Center. The software implemented two new dose comparison parameters, the 2D normalized agreement test (NAT) and the scalar NAT index. A single-film calibration technique using multileaf collimator (MLC) delivery was developed. EDR2 film's optical density response was found to be sensitive to several factors: radiation time, length of time between exposure and processing, and phantom material. Precision of EDR2 film measurements was found to be better than 1%. For IMRT verification, EDR2 film measurements agreed with ion chamber results to 2%/2mm accuracy for single-beam fluence map verifications and to 5%/2mm for transverse plane measurements of complete plan dose distributions. The same system was used to quantitatively optimize the radiation field offset and MLC transmission beam modeling parameters for Varian MLCs. While scalar dose comparison metrics can work well for optimization purposes, the influence of external parameters on the dose discrepancies must be minimized. The ability of 2D verifications to detect delivery errors was tested with simulated data. The dosimetric characteristics of delivery errors were compared to patient-specific clinical IMRT verifications. For the clinical verifications, the NAT index and percent of pixels failing the gamma index were exponentially distributed and dependent upon the measurement phantom but not the treatment site. Delivery errors affecting all beams in the treatment plan were flagged by the NAT index, although delivery errors impacting only one beam could not be differentiated from routine clinical verification discrepancies. Clinical use of this system will flag outliers, allow physicists to examine their causes, and perhaps improve the level of agreement between radiation dose distribution measurements and calculations. The principles used to design and evaluate this system are extensible to future multidimensional dose measurements and comparisons. ^

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In a large health care system, the importance of accurate information as feedback mechanisms about its performance is necessary on many levels from the senior level management to service level managers for valid decision-making purposes. The implementation of dashboards is one way to remedy the problem of data overload by providing up-to-date, accurate, and concise information. As this health care system seeks to have an organized, systematic review mechanism in place, dashboards are being created in a variety of the hospital service departments to monitor performance indicators. The Infection Control Administration of this health care system is one that does not currently utilize a dashboard but seeks to implement one. ^ The purpose of this project is to research and design a clinical dashboard for the Infection Control Administration. The intent is that the implementation and usefulness of the clinical dashboard translates into improvement in the measurement of health care quality.^

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This cross-sectional study examined the prevalence of depressive symptoms in urban Hispanic and African American middle and high school students (N=1,292) using data collected from a multi-component, multi-wave violence and substance use intervention program targeted at a large urban school district in Texas. Chi-square analysis was used to examine differences in race/ethnicity, gender, grade level and whether or not a student had been held back/repeated a grade in school. Univariate and multivariate logistic regression were used to analyze the association between depressive symptoms and demographic variables. Being female and being held back/repeating a grade was significantly associated with depressive symptoms in both univariate and multivariate analyses. Overall 16% of the students reported depressive symptoms; Hispanic youth had a higher prevalence of depressive symptoms (16.8%) than the African American youth (14.8%). Minority females and those who had been held back/repeated a grade reported a prevalence of 19.4% and 21.2%, respectively. Further research is needed to understand why Hispanic youth continue to report a higher prevalence of depressive symptoms than other minorities. Additionally research is required to further explore the association between academic performance and depressive symptoms in urban minorities, specifically the effect of being held back/repeating a grade.^

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The influence of respiratory motion on patient anatomy poses a challenge to accurate radiation therapy, especially in lung cancer treatment. Modern radiation therapy planning uses models of tumor respiratory motion to account for target motion in targeting. The tumor motion model can be verified on a per-treatment session basis with four-dimensional cone-beam computed tomography (4D-CBCT), which acquires an image set of the dynamic target throughout the respiratory cycle during the therapy session. 4D-CBCT is undersampled if the scan time is too short. However, short scan time is desirable in clinical practice to reduce patient setup time. This dissertation presents the design and optimization of 4D-CBCT to reduce the impact of undersampling artifacts with short scan times. This work measures the impact of undersampling artifacts on the accuracy of target motion measurement under different sampling conditions and for various object sizes and motions. The results provide a minimum scan time such that the target tracking error is less than a specified tolerance. This work also presents new image reconstruction algorithms for reducing undersampling artifacts in undersampled datasets by taking advantage of the assumption that the relevant motion of interest is contained within a volume-of-interest (VOI). It is shown that the VOI-based reconstruction provides more accurate image intensity than standard reconstruction. The VOI-based reconstruction produced 43% fewer least-squares error inside the VOI and 84% fewer error throughout the image in a study designed to simulate target motion. The VOI-based reconstruction approach can reduce acquisition time and improve image quality in 4D-CBCT.