925 resultados para Ultrasonic Vocalizations (USVs)
Resumo:
This paper addresses the problem of processing biological data, such as cardiac beats in the audio and ultrasonic range, and on calculating wavelet coefficients in real time, with the processor clock running at a frequency of present application-specified integrated circuits and field programmable gate array. The parallel filter architecture for discrete wavelet transform (DWT) has been improved, calculating the wavelet coefficients in real time with hardware reduced up to 60%. The new architecture, which also processes inverse DWT, is implemented with the Radix-2 or the Booth-Wallace constant multipliers. One integrated circuit signal analyzer in the ultrasonic range, including series memory register banks, is presented. © 2007 IEEE.
Resumo:
The aim of this study was to evaluate the shape of dental cavities made with the CVDentus® system using different ultrasound power levels. One standard cavity was made on the buccal aspect of 15 bovine incisors with a CVDentus® cylindrical bur (82142). The sample was divided into three groups: G1 - ultrasound with power II; G2 - ultrasound with power III; and G3 - ultrasound with power IV. A standardizing device was used to obtain standardized preparations and ultrasound was applied during one minute in each dental preparation. The cavities were sectioned in the middle, allowing observation of the cavity's profile with a magnifying glass, and width and depth measurement using the Leica Qwin program. The Kruskal-Wallis (p < 0.05) and Dunn statistical analyses demonstrated differences between the dental cavity shapes when powers III and IV were used. However, the cavities that were made with power III presented dimensions similar to those of the bur used for preparation. We concluded that the power recommended by the manufacturer (III) is the most adequate for use with the CVDentus® system.
Resumo:
The literature has discussed the importance of early implementation of augmentative and alternative systems with people with various disabilities. This discussion is related to concerns about language acquisition and development within the various expressive possibilities. Researchers advise that starting intervention early through resources and procedures using augmentative and alternative communication does not impede speech acquisition and development. This paper aimed to describe oral expressive abilities during the implementation of augmentative and alternative communication with a student with cerebral palsy. An 11-year-old student with cerebral palsy participated in the augmentative and alternative communication program for two years. Twelve sessions were selected during the first year of the intervention. The sessions were filmed and the augmentative and alternative communication resource procedures were transcribed. The categories of analysis were defined as verbal expression; nonverbal expression and verbal and nonverbal expression associated. The results of this study identified that augmentative and alternative communication resources supported the use of verbal expression such as vocalizations, words and unintelligible oral expressions.
Resumo:
Aiming to compare milk yield, residual milk and behavioral responses of Holstein cows during milking, fourteen experimental cows were mechanically milked twice a day, and evaluated during the first six weeks of lactation. Milk yield was measured daily, and residual milk volume weekly. Body (ribs region), udder and teat temperatures and respiratory frequency were measured twice a week. Animal behavior at the milking parlor was registered using ethograms and interviews with the milkers. During the first weeks of lactation, a higher percentage of kicks, over-steps, milking cups being knocked down, urinations and vocalizations in primiparous cows (p < 0.05) was observed, which were also considered more reactive by the parlors compared to multiparous cows. Multiparous cows produced more milk than primiparous (p < 0.05). However, there were no significant differences in residual milk percentage (p > 0.05), which suggests adaptation of both groups to the milking environment.
Resumo:
This work presents a method to obtain B-scan images based on linear array scanning and 2R-SAFT. Using this technique some advantages are obtained: the ultrasonic system is very simple; it avoids the grating lobes formation, characteristic in conventional SAFT; and subaperture size and focussing lens (to compensate emission-reception) can be adapted dynamically to every image point. The proposed method has been experimentally tested in the inspection of CFRP samples. © 2010 American Institute of Physics.
The influence of grain size coating and shaft angulation of different diamond tips on dental cutting
Resumo:
Objectives: To evaluate the influence of the grain size coating and shaft angulation of ultrasonic and high-speed diamond burs on the dental cutting effectiveness. Materials and Methods: For the grain size evaluation, cavities were prepared on 40 incisors using high-speed (1092 and 1093F KG Sorensen®) and ultrasonic tips (8.2142 and 6.2142-CVDentus®). For the shaft angulation evaluation, cavities were prepared on 40 incisors using uniangulated (T1-CVDentus®) and biangulated (T1-A CVDentus®) ultrasonic tips. The cavities were bisected and examined at 50 magnification. The width and depth of cavities were measured by Leica QWin software. Kruskal-Wallis non-parametric test was used for analysis. Results: The grain size did not affect the cutting effectiveness, but the high-speed burs promoted deeper and wider cavities than the ultrasonic tips. The shaft angulation did not affect the cutting effectiveness; both the angulated and biangulated tips had greater cutting efficiency in dentin than in enamel. Conclusions: Ultrasonic tips promoted more conservative preparations and seemed promising for cavity preparation.
Resumo:
ITO nanowires were synthesized by carbothermal reduction process, using a co-evaporation method, and have controlled size, shape, and chemical composition. The electrical measurements of nanowires showed they have a resistance of about 102 Ω. In order to produce nanocomposites films, nanowires were dispersed in toluene using an ultrasonic cleaner, so the PMMA polymer was added, and the system was kept under agitation up to obtain a clear suspension. The PMMA polymer was filled with 1, 2, 5 and 10% in weight of nanowires, and the films were done by tape casting. The results showed that the electrical resistance of nanocomposites changed by over 7 orders of magnitude by increasing the amount of filler, and using 5 wt% of filler the composite resistance decreased from 1010 Ω to about 104 Ω, which means that percolation threshold of wires occurred at this concentration. This is an interesting result once for nanocomposites filled with ITO nanoparticles is necessary about 18% in weight to obtain percolation. The addition of filler up to 10 wt% decreased the resistance of the composite to 103 Ω, which is a value close to the resistance of wires. The composites were also analyzed by transmission electron microscopy (TEM), and the TEM results are in agreement with the electrical ones about percolation of nanowires. These results are promising once indicates that is possible to produce conductive and transparent in the visible range films by the addition of ITO nanowires in a polymeric matrix using a simple route. © 2011 Materials Research Society.
Resumo:
In this work, signal processing techniques are used to improve the quality of image based on multi-element synthetic aperture techniques. Using several apodization functions to obtain different side lobes distribution, a polarity function and a threshold criterium are used to develop an image compounding technique. The spatial diversity is increased using an additional array, which generates complementary information about the defects, improving the results of the proposed algorithm and producing high resolution and contrast images. The inspection of isotropic plate-like structures using linear arrays and Lamb waves is presented. Experimental results are shown for a 1-mm-thick isotropic aluminum plate with artificial defects using linear arrays formed by 30 piezoelectric elements, with the low dispersion symmetric mode S0 at the frequency of 330 kHz. © 2011 American Institute of Physics.
Resumo:
Background: Doppler ultrasonography is a non-invasive real time pulse-wave technique recently used for the transrectal study of the reproductive system hemodynamics in large animals. This technic is based in the Doppler Effect Principle that proposes the change in frequency of a wave for an observer (red blood cells) moving relative to the source of the respective wave (ultrasonic transducer). This method had showed to be effective and useful for the evaluation of the in vivo equine reproductive tract increasing the diagnostic, monitoring, and predictive capabilities of theriogenology in mares. However, an accurate and truthful ultrasonic exam requires the previous knowledge of the Doppler ultrasonography principles. Review: In recent years, the capabilities of ultrasound flow imaging have increased enormously. The current Doppler ultrasound machines offer three methods of evaluation that may be used simultaneously (triplex mode). In B-mode ultrasound, a linear array of transducers simultaneously scans a plane through the tissue that can be viewed as a two-dimensional gray-scale image on screen. This mode is primarily used to identify anatomically a structure for its posterior evaluation using colored ultrasound modes (Color or Spectral modes). Colored ultrasound images of flow, whether Color or Spectral modes, are essentially obtained from measurements of moving red cells. In Color mode, velocity information is presented as a color coded overlay on top of a B-mode image, while Pulsed Wave Doppler provides a measure of the changing velocity throughout the cardiac cycle and the distribution of velocities in the sample volume represented by a spectral graphic. Color images conception varies according to the Doppler Frequency that is the difference between the frequency of received echoes by moving blood red cells and wave frequency transmitted by the transducer. To produce an adequate spectral graphic it is important determine the position and size of the simple gate. Furthermore, blood flow velocity measurement is influence by the intersection angle between ultrasonic pulses and the direction of moving blood-red cells (Doppler angle). Objectively colored ultrasound exam may be done on large arteries of the reproductive tract, as uterine and ovary arteries, or directly on the target tissue (follicle, for example). Mesovarium and mesometrium attachment arteries also can be used for spectral evaluation of the equine reproductive system. Subjectively analysis of the ovarian and uterine vascular perfusion must be done directly on the corpus luteum, follicular wall and uterus (endometrium and myometrium associated), respectively. Power-flow imaging has greater sensitivity to weak blood flow and independent of the Doppler angle, improving the evaluation of vessels with small diameters and slow blood flow. Conclusion: Doppler ultrasonography principles, methods of evaluation and reproductive system anatomy have been described. This knowledge is essential for the competent equipment acquisition and precise collection and analysis of colored ultrasound images. Otherwise, the reporting of inconsistent and not reproducible findings may result in the discredit of Doppler technology ahead of the scientific veterinary community.
Resumo:
Influence of cutting instruments and The aim of this study was to analyze the hybrid layer in noncarious dentin prepared by different cutting instruments and restored with composite resin. The cavities were randomly prepared in 40 specimens using a high-speed diamond bur (KG Sorensen 1013) and an ultrasonic tip (CVDentus C22). The cavities were restored with composite resin by varying the adhesive system between the Adper™ Single Bond (2 x 1 system, primer+adhesive) and the Prompt L-Pop™ (3 x 1 system, self-etching). The restorations were hemisected longitudinally and analyzed in the SEM (Scanning electron microscopy) in order to evaluate the hybrid layer and resinous tags characteristics, using scores ranging from 1 to 6. The Pearson test revealed a high correlation coefficient and good significance levels for both intra- and inter-raters values (r=0.90). The data were statistically analyzed using the Mann-Whitney test (P≤0.05). A larger proportion of regular hybrid layers with numerous tags were observed in the dentin prepared using the high-speed diamond burs and restored with a 2 × 1 adhesive system. Alternatively, the 3 × 1 adhesive system promoted the generation of a thin hybrid layer with few tags. After preparation using an ultrasonic tip revealed few or no tags after the preparation and 2 × 1 or 3 × 1 adhesive system application. The high-speed diamond burs produced a dentin surface that was more favorable to restorative material adhesion than the ultrasonic tips, regardless of the adhesive system used.
Resumo:
In the majority of cases of bone fracture requiring surgery, orthopedic implants (screw-plate and screw) are used for osteosynthesis and the infections associated with such implants are due to the growth of microorganisms in biofilms. The objective of this study was to identify microorganisms recovered from osteosynthesis implants used to fix bone fractures, to assess the viability of the cells and the ability of staphylococci to adhere to a substrate and to determine their sensitivity/resistance to antimicrobials. After surgical removal, the metal parts of austenitic stainless steel (ASTM F138/F139 or ISO NBR 5832-1/9) were transported to the Laboratory of Clinical Microbiology, washed in buffer and subjected to ultrasonic bath at 40±2 kHz for 5 minutes. The sonicated fluid was used to seed solid culture media and cell viability was assessed under the microscope by with the aid of a fluorescent marker. The production of extracellular polysaccharide by Staphylococcus spp. was investigated by means of adhesion to a polystyrene plate. The profile of susceptibility to antimicrobials was determined by the disk diffusion assay. The most frequently isolated bacteria included coagulase-negative Staphylococcus resistant to erythromycin, clindamycin and oxacillin. Less frequent were Pseudomonas aeruginosa resistant to trimethoprim/sulfamethoxazole and ampicillin, Acinetobacter baumannii resistant to ceftazidime, Enterobacter cloacae resistant to cephalothin, cefoxitin, cefazolin, levofloxacin and ciprofloxacin, Bacillus spp. and Candida tropicalis. The observation of slides by fluorescence microscope showed clusters of living cells embedded in a transparent matrix. The test for adherence of coagulase-negative Staphylococcus to a polystyrene plate showed that these microorganisms produce extracellular polysaccharide. In conclusion, the metal parts were colonized by bacteria related to orthopedic implant infection, which were resistant to multiple antibiotics.
Resumo:
Objectives: The aim of this study was to evaluate the effect of different seating forces during cementation in cement-ceramic microtensile bond strength (μTBS). Materials and methods: Forty-five blocks (5 × 5 × 4 mm3) of a glass-infiltrated alumina-based ceramic (In-Ceram Alumina) were fabricated according to the manufacturer's instructions and duplicated in resin composite. Ceramic surfaces were polished, cleaned for 10 min in an ultrasonic bath, silica coated using a laboratory type of air abrasion device, and silanized. Each treated ceramic block was then randomly assigned to five groups (n = 9) and cemented to a composite block under five seating forces (10 g, 50 g, 100 g, 500 g, and 750 g) using a dual-cured resin cement (Panavia F). The ceramic-cement-composite assemblies were cut under coolant water to obtain bar specimens (1 mm × 0. 8 mm2). The μTBS tests were performed in a universal testing machine (1 mm/min). The mean bond strengths values were statistically analyzed using one-way ANOVA (α ≤ 0. 05). Results: Different seating forces resulted in no significant difference in the μTBS results ranging between 13. 1 ± 4. 7 and 18. 8 ± 2. 1 MPa (p = 0. 13) and no significant differences among cement thickness. Conclusions: Excessive seating forces during cementation seem not to affect the μTBS results. Clinical relevance: Excessive forces during the seating of single all-ceramic restorations cementation seem to display the same tensile bond strength to the resin cement. © 2012 Springer-Verlag.
Resumo:
Aim: The aim of this study was to compare the microtensile bond strength of three adhesive systems, using different methods of dentin preparation. Materials and methods: A hundred and eight bovine teeth were used. The dentin from buccal face was exposed and prepared with three different methods, divided in 3 groups: Group 1 (DT)- diamond tip on a high-speed handpiece; Group 2 (CVD)-CVD tip on a ultrasonic handpiece; Group 3 (LA)-Er: YAG laser. The teeth were divided into 3 subgroups, according adhesive systems used: Subgroup 1-Adper Single Bond Plus/3M ESPE (SB) total-etch adhesive; Subgroup 2-Adper Scotchbond SE/3M ESPE (AS) selfetching adhesive; Subgroup 3-Clearfil SE Bond/Kuraray (CS) selfetching adhesive. Blocks of composite (Filtek Z250-3M ESPE) 4 mm high were built up and specimens were stored in deionized water for 24 hours at 37°C. Serial mesiodistal and buccolingual cuts were made and stick-like specimens were obtained, with transversal section of 1.0 mm2. The samples were submitted to microtensile test at 1 mm/min and load of 10 kg in a universal testing machine. Data (MPa) were subjected to ANOVA and Tukey's tests (p < 0.05). Results and conclusion: Surface treatment with Diamond or CVD tips associated with Clearfil SE Bond adhesive produced significantly lower bond strength values compared to other groups. Surface treatment with Er: YAG laser associated with Single Bond Plus or Clearfil SE Bond adhesives and surface treatment with CVD tip associated with Adper Scotchbond SE adhesive produced significantly lower bond strength values compared to surface treatment with diamond or CVD tips associated with Single Bond Plus or Adper Scotchbond SE adhesives. Clinical significance: Interactions between laser and the CVD tip technologies and the different adhesive systems can produce a satisfactory bonding strength result, so that these associations may be beneficial and enhance the clinical outcomes.
Resumo:
The primary objective of this study was to examine the follicular and ovulatory responses following treatment with pFSH in association with ablation-induced or spontaneous follicular wave emergence or follicle deviation during diestrus in crossbred (Mangalarga × Arabian) and Brazilian Warmblood mares with a propensity for spontaneous multiple ovulations; secondary considerations were given to the collection of embryos In Experiment 1, crossbred mares were administered (im) saline (control, n= 7) or pFSH (25 mg) when the largest follicle of the ablation-induced follicular wave reached ≥13 mm (n= 7) or ≥20 mm (n= 7) or, after pre-treatment ovulation (Day 0) on Day 6 (n= 7) In Experiment 2, crossbred mares were administered (im) saline (control, n= 10) or a larger dose of pFSH (50 mg, n= 7) when the largest follicle of the ablation-induced follicular wave reached ≥13 mm In Experiment 3, Brazilian Warmblood mares were administered (im) saline (control, n= 7), pFSH (25 mg, n= 7 or 50 mg, n= 5) or EPE (12.5 mg, n= 7) as a positive control on Day 6 Ultrasonic technology was used to ablate all follicles ≥8 mm and to monitor follicular development and detect ovulation Treatment with pFSH or EPE was done twice daily until the largest follicle reached ≥32 mm; thereafter, hCG (2500 IU) was administered (iv) when the largest follicle reached ≥35 mm Artificial insemination was done 12 h after hCG and embryo collections were done 8 d after post-treatment ovulations In Experiments 1 and 2, treatment of crossbred mares with pFSH post-ablation in association with the expected time of wave emergence or follicle deviation did not (P> 0.05) enhance the follicular or ovulatory responses or collection of embryos compared to controls In Experiment 3, although the enhanced ovulatory response of mares to EPE at the expected time of spontaneous wave emergence was not different (P> 0.05) from controls, it was greater (P< 0.05) than the response to pFSH In conclusion, the novelty of using follicle ablation prior to pFSH treatment at the time of wave emergence or follicle deviation did not enhance the follicular or ovulatory responses or collection of embryos to treatment in crossbred mares In addition, the hypothesis that Brazilian Warmblood mares with a greater propensity for spontaneous multiple ovulations are as responsive to pFSH compared to EPE was not supported Thus, the combined experimental results of the present study continue to support the general consensus that pFSH is relatively ineffective for follicular superstimulation/superovulation in mares © 2012 Elsevier B.V.
Resumo:
Predators directly and indirectly affect the density and the behavior of prey. These effects may potentially cascade down to lower trophic levels. In this study, we tested the effects of predator calls (playbacks of bird vocalizations: Tyto alba, Speotyto cunicularia, and Vanellus chilensis), predator visual stimuli (stuffed birds) and interactions of visual and auditory cues, on the behavior of frugivore phyllostomid bats in the field. In addition, we tested if the effects of predation risk cascade down to other trophic levels by measuring rates of seed dispersal of the tree Muntingia calabura. Using video recording, we found that bats significantly decreased the foraging frequency on trees when a visual cue of T. alba was present. However, no stimuli of potential predatory birds, including vocalization of T. alba, affected bat foraging frequency. There was a change in bat behavior during 7 min, but then their frequency of activity gradually increased. Consequently, the presence of T. alba decreased by up to ten times the rate of seed removal. These results indicate that risk sensitivity of frugivorous phyllostomid bats depends on predator identity and presence. Among the predators used in this study, only T. alba is an effective bat predator in the Neotropics. Sound stimuli of T. alba seem not to be a cue of predation risk, possibly because their vocalizations are used only for intraspecific communication. This study emphasizes the importance of evaluating different predator stimuli on the behavior of vertebrates, as well as the effects of these stimuli on trait-mediated trophic cascades. © 2013 Springer-Verlag Berlin Heidelberg.