938 resultados para ULTRASOUND-GUIDED BIOPSY


Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents a method for the quantification of cellular rejection in endomyocardial biopsies of patients submitted to heart transplant. The model is based on automatic multilevel thresholding, which employs histogram quantification techniques, histogram slope percentage analysis and the calculation of maximum entropy. The structures were quantified with the aid of the multi-scale fractal dimension and lacunarity for the identification of behavior patterns in myocardial cellular rejection in order to determine the most adequate treatment for each case.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: The purpose of this study was to research a membrane material for use in guided bone regeneration. Study design: In this study, 25 male Wistar rats were used to analyze the biocompatibility and degradation process of biomembranes. The morphological changes in subcutaneous implantations were assessed after 7, 14, 21, 28 and 70 days. The materials were made of polyurethane polymer (AUG) obtained from vegetal oil (Ricinus communis) and polytetrafluoroethylene membrane (PTFE). The surface characteristics of the physical barriers in scanning electronic microscopic (SEM) were also evaluated. Results: In both groups, the initial histological analysis showed moderate inflammatory infiltrate, which was predominantly polymorphonuclear. There was also a presence of edema, which was gradually replaced by granulation tissue, culminating in a fibrous capsule. In the AUG group, some multinucleated giant cells were present in the contact interface, with the space previously occupied by the material. However, membrane degradation was not observed during the period studied. According to the present SEM findings, porosity was not detected in the AUG or PTFE membranes. Conclusion: The researched material is biocompatible and the degradation process is extremely slow or may not even occur at all.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of the present study was to investigate bone promotion in surgical defects created in the mandible of normal and ovariectomized female rats using calcitonin associated with a polytetrafluoroethylene barrier. The 100 female rats were divided into four groups: control (C), control treated with calcitonin (CM), ovariectomized control (OV) and ovariectomized treated with calcitonin (OVM). A circumscribed bone defect 4 mm in diameter was created in the region of the mandibular angle, and covered with the barrier. Groups CM and OVM received 2 IU/kg of synthetic salmon calcitonin intramuscularly three times a week. The animals were killed 3, 7, 14, 21 and 28 days after surgery. The bone defects were submitted to densitometric, histologic and histomorphometric analysis. Groups C and CM showed higher levels of bone formation after 7 days compared to the OV and OVM groups. A significant difference was observed between groups C and OV at 3-14 days. The OV group presented slower bone regeneration of the surgical bone defect created in the mandibular angle than group C. Synthetic salmon calcitonin accelerated regeneration of the bone defect in the mandibles of OVM animals similarly to group C, and also increased the formation of new bone during the regeneration process in CM.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this paper was report the clinical, radiographic, and histological case of adenomatoid odontogenic tumour (AOT) in adolescent woman as well as present the reconstructive treatment of AOT using fresh-frozen human bone graft with guided bone regeneration. AOT is a benign, noninvasive lesion with slow but progressive growth. Biopsy and microscopic examination confirmed the presence of an AOT. Treatment was conservative and the prognosis was excellent. The patient has been followed-up for without recurrence. The use of fresh-frozen human bone graft can be a safe choice for reconstruction of the bone defects to treat AOT.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: The aim of this study was to evaluate the possibility of obtaining guided bone regeneration using a poly-tetrafluoroethylene (PTFE) nonporous barrier for 2 endosseous implants, partially inserted in tibiae of rabbits.Materials and Methods: Histologic characteristics of the interface between titanium implants (one group with titanium plasma-coated implants and the other group with acid-treated surfaces) and of the regenerated bone were also studied. Twenty screw-vent implants were placed in tibiae of 5 male New Zealand rabbits, 2 at the right side and 2 at the left side, protruding 3 mm from the bone level, to create a horizontal bone defect. At the experimental group the implants were with a PTFE nonporous barrier, whereas no barriers were used in contralateral implants. Animals were sacrificed 3 months after surgery and biopsy specimens were evaluated histologically and histomorphometrically under light microscopy. Student's t test was used for statistical analysis.Results: The histologic measurements showed a mean gain in bone height of 2.15 and 2.42 mm for the barrier group and 1.95 and 0.43 mm for the control group, for the titanium plasma-spray and acid-treated implant surfaces, respectively.Conclusion: The results of the investigation revealed that the placement of implants protruding 3 nun from crestal bone defects may result in vertical bone augmentation using a nonporous PTFE barrier. (Implant Dent 2009;18:182-191)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study was to compare intrapulpal temperature increase produced by high-speed handpiece, Er:YAG laser and CVDentus ultrasound tips during cavity preparation. Thirty bovine mandibular incisors with an enamel/dentin thickness of 4 mm at buccal surface had their roots amputated and were allocated to the following groups (n=10): Group I- high-speed handpiece; Group II- noncontact Er:YAG laser (250 mJ/4Hz); and Group III- CVDentus ultrasouns tips. All devices were used with water cooling. Class V cavities were prepared to a depth of 3.5 mm, measured with a periodontal probe. A type T thermocouple was placed inside the pulp chamber to determine the temperature increase (degrees C), which was recorded by a data acquisition system ADS 2000 IP (Lynx Technology) linked to a notebook computer. Data were analyzed statistically by oneway ANOVA and Tukey's test (p=0.05). The mean temperature rises were: 1.10 degrees C ( 0.56) for Group 1, 0.84 degrees C (0.55) for Group II, and 3.00 degrees C (1.34) for Group III. There were no statistically significant differences (p > 0.05) between Groups I and II, but both of them differed significantly from Group III (p < 0.05). In conclusion, the use of Er:YAG laser and high-speed handpiece for cavity preparation resulted in similar temperature increase. Although ultrasound tips generated significantly higher intrapulpal temperature increase, it remained below the critical value of 5.5 degrees C and may be considered safe for use.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: The aim of this study was to evaluate the influence of dentin abrasion on the microshear bond strength of two self-etching adhesive systems, using either an ultrasound diamond bur or a high-speed diamond bur.Materials and Methods: Twenty noncarious human third molars were sectioned mesiodistally into halves. The enamel was ground to expose a flat dentin surface on both sections. The dentinal surfaces were randomly assigned to two groups, depending on the method of smear layer preparation: ultrasound diamond bur (UB) or conventional diamond bur (CB). The prepared dentin surfaces received one of two self-etching systems: Clearfil SE Bond (CF) and One-Up Bond F (OB). A composite cylinder with a 0.95-mm diameter was bonded to each specimen and the microshear bond test was performed. The results were expressed in MPa and were subjected to two-way analysis of variance (ANOVA) and Tukey's test (alpha = 0.05).Results: There was no significant difference in dentin bond strength when comparing the conventional and ultrasonic abrasion methods. When the adhesive systems were compared, Clearfil SE Bond achieved higher bond strength means than did One-Up Bond F.Conclusion: The dentin surface preparation method did not influence the microshear bond strength and the Clearfil SE Bond adhesive system, independent of bur type used, Clearfil SE Bond showed higher bond strengths than did the One-Up Bond F adhesive system.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Ultrasound effects on the release and activity of invertase from Aspergillus niger cultivated in a medium containing sucrose and peptone and in another with sugar-cane molasses and peptone were investigated. Irradiation was conducted for periods of 2 - 10 min. with waves of amplitude 20 and 40 using an ultrasound processor of 20 kHz. Product formation was determined as reducing equivalents formed by time units using 3,5-dinitrosalicylic acid. Total and specific activities of the culture supernatants were compared in the presence and absence of sonication. Both amplitudes promoted a significant increase of total invertase activity in the time periods investigated and the highest values were obtained with an amplitude of 20. Ultrasound irradiation caused cell disruption, thus releasing invertase and, after 4 min, activation of the enzyme also occurred. The best conditions for production, extraction and activation of invertase were in molasses medium containing peptone and irradiation with ultrasound waves at 20 for 8 min. This method showed high efficiency for the extraction and activation of invertase from A. niger as well as a great potential for use in industrial processes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A regeneração periodontal e do rebordo ósseo utilizando barreiras físicas são procedimentos bem estabelecidos em cirurgias reconstrutivas. As características do biomaterial e o desenho da membrana empregados na regeneração tecidual guiada desempenham um papel importante na obtenção de bons resultados. O objetivo deste estudo experimental histológico foi comparar o uso de dois tipos de barreiras físicas na regeneração óssea guiada em defeitos criados na tíbia de ratos. Quinze animais foram divididos em três grupos: grupo I (barreira não-porosa de politetrafluoretileno), grupo II (blocos de hidroxiapatita de coral) e grupo III (controle que não recebeu nenhuma barreira). A análise histológica demonstrou várias quantidades de osso neoformado com ambos os tipos de barreiras. A barreira de politetrafluoretileno mostrou melhores resultados do que a hidroxiapatita. Os resultados deste estudo sugerem que a regeneração óssea pode ser conseguida com a técnica de submersão da barreira física.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A paca é um roedor sul-americano cujo manejo, tranqüilização ou anestesia oferece um grande campo de pesquisa devido aos poucos artigos existentes. Doze pacas fêmeas adultas foram utilizadas, mantidas separadas em seis baias, sendo capturadas com um puçá de polipropileno e levadas a uma sala na qual se realizava a tricotomia abdominal. Após, os animais eram colocados em uma gaiola de ferro de compressão lateral. A sessão de ultra-sonografia era realizada em modo B com um transdutor setorial eletrônico de 5,0 e 7,5 MHz. Para a diminuição do estresse causado pelos procedimentos, a tranqüilização das fêmeas era realizada com diazepam e maleato de midazolam por via oral. Ambos demonstraram-se efetivos na tranqüilização das pacas previamente e durante as sessões, sendo que o maleato de midazolam proporcionou um melhor manejo dos animais.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A simple calorimetric method was employed to study the kinetics of the hydrolysis of the solventless TMOS-water mixtures, under ultrasound stimulation, as a function of the concentration of oxalic acid. The reaction rates were obtained, in relative units, from the measured thermal peak of the reaction as a non-separated function of both the sonication time and the instantaneous temperature of the medium. For concentrations of oxalic acid below 0.01 M, polycondensation reaction starts before complete hydrolysis. For concentrations of oxalic acid above 0.01 M, hydrolysis is complete and, in addition, the inverse of the time, as measured from the starting of ultrasound action until the maximum hydrolysis heat release, was found to be a reasonable relative measure of the average hydrolysis rate constant. The average hydrolysis rate constant was found to be proportional to the square root of the molar concentration of the oxalic acid. This result is in agreement with the literature if we assume small dissociation degree for the catalyst in such a solventless alkoxyde-water medium.