903 resultados para Tests for Continuous Lifetime Data
Resumo:
We have measured the Lambda(b) lifetime using the exclusive decay Lambda(b)-> J/psi Lambda, based on 1.2 fb(-1) of data collected with the D0 detector during 2002-2006. From 171 reconstructed Lambda(b) decays, where the J/psi and Lambda are identified via the decays J/psi ->mu(+)mu(-) and Lambda -> p pi, we measured the Lambda(b) lifetime to be tau(Lambda(b))=1.218(-0.115)(+0.130)(stat)+/- 0.042(syst) ps. We also measured the B-0 lifetime in the decay B-0 -> J/psi(mu(+)mu(-))K-S(0)(pi(+)pi(-)) to be tau(B-0)=1.501(-0.074)(+0.078)(stat)+/- 0.050(syst) ps, yielding a lifetime ratio of tau(Lambda(b))/tau(B-0)=0.811(-0.087)(+0.096)(stat)+/- 0.034(syst).
Resumo:
We present measurements of the Lambda(b)(0) lifetime in the exclusive decay channel Lambda(b)(0)-> J/psi Lambda(0), with J/psi ->mu(+)mu(-) and Lambda(0)-> p pi(-), the B-0 lifetime in the decay B-0-> J/psi K-S(0) with J/psi ->mu(+)mu(-) and K-S(0)->pi(+)pi(-), and the ratio of these lifetimes. The analysis is based on approximately 250 pb(-1) of data recorded with the D0 detector in p (p) over bar collisions at root s = 1.96 TeV. The Lambda(b)(0) lifetime is determined to be tau(Lambda(b)(0))=1.22(-0.18)(+0.22)(stat)+/- 0.04(syst) ps, the B-0 lifetime tau(B-0)=1.40(-) (+0.11)(0.10)(stat)+/- 0.03(syst) ps, and the ratio tau(Lambda(b)(0))/tau(B-0)=0.87(-) (+0.17)(0.14)(stat)+/- 0.03(syst). In contrast with previous measurements using semileptonic decays, this is the first determination of the Lambda(b)(0) lifetime based on a fully reconstructed decay channel.
Resumo:
We compare the results obtained by using the continuous emission model with data from Ph-Ph collisions. We determine the initial conditions necessary to reproduce the strange particle ratios (experiment WA97) and with the obtained results, we study the dependence on particle mass of the inverse slope parameter T. Some particle spectra are also shown.
Resumo:
From an analysis of the decay B-s(0)-> J/psi phi, we obtain the width difference between the light and heavy mass eigenstates Delta Gamma equivalent to(Gamma(L)-Gamma(H))=0.17 +/- 0.09(stat)+/- 0.02(syst) ps(-1) and the CP-violating phase phi(s)=-0.79 +/- 0.56(stat)(-0.01)(+0.14)(syst). Under the hypothesis of no CP violation (phi(s)equivalent to 0), we obtain 1/Gamma=tau/(B-s(0))=1.52 +/- 0.08(stat)(-0.03)(+0.01)(syst) ps and Delta Gamma=0.12(-0.10)(+0.08)(stat)+/- 0.02(syst) ps(-1). The data sample corresponds to an integrated luminosity of about 1.1 fb(-1) accumulated with the D0 detector at the Fermilab Tevatron collider. This is the first direct measurement of the CP-violating mixing phase in the B-s(0) system.
Resumo:
Recent progress in the solution of Schwinger-Dyson equations, as well as lattice simulation of pure glue QCD, indicate that the gluon propagator and coupling constant are infrared finite. Such non-perturbative information can be introduced in the QCD perturbative expansion in the scheme named Dynamical Perturbation Theory. We exemplify this procedure with the calculation of some two-body non-leptonic annihilation B meson decays, which show agreement with the experimental data in the case of a gluon propagator characterized by a dynamical gluon mass of 500MeV, compatible with the value found in several processes computed with this method. We give a. preliminary account of the application of this procedure at the loop level in the case of the Bjorken sum rule.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Amino acids are well metabolized by Streptomyces clavuligerus during the production of clavulanic acid using glycerol as main carbon and energy source. However, only a few amino acids such as arginine and ornithine are favorable for CA biosynthesis. The aim of this work was to optimize the glycerol:ornithine molar ratio in the feed medium containing only these compounds to maximize CA production in continuous cultivation. A minimum number of experiments were performed by means of a simple two-level full-factorial central composite design to investigate the combined effect of glycerol and ornithine feeding on the CA concentration during the intermittent and continuous process in shake-flasks. Statistical analysis of the experimental data using the response surface methodology showed that a glycerol-to-ornithine molar ratio of approximately 40:1 in the feed medium resulted in the highest CA concentration when fermentation was stopped. Under these optimized conditions, in bench-scale fermentor runs, the CA concentration reached more than double the concentration obtained in shake-flasks runs. (C) 2009 Elsevier B.V. All rights reserved.
Resumo:
O objetivo deste trabalho foi determinar o tempo ótimo de escarificação das sementes de Senna alata em ácido sulfúrico e verificar o efeito da temperatura, em condição de luz e escuro, na germinação de sementes dessa espécie. As sementes foram imersas em ácido sulfúrico concentrado por períodos de 0, 15, 30 e 60 minutos, e o teste de germinação realizado em BOD a 25ºC, utilizando quatro repetições de 50 sementes em cada período de tempo, sendo o delineamento estatístico inteiramente casualizado com 4 tratamentos. No segundo experimento, para verificar o efeito da temperatura e da condição de luz mais adequada a germinação, utilizou-se temperaturas de 10 a 45ºC, com intervalos de 5ºC, em condição de luz fluorescente branca ou escuro contínuo (gerbox preto). Utilizou-se o delineamento experimental inteiramente casualizado, disposto em esquema fatorial 8x2, com 4 repetições, de 50 sementes cada. em todos os testes as avaliações da porcentagem e índice de velocidade de germinação foram feitas diariamente, durante 10 dias, onde as sementes foram consideradas germinadas quando apresentaram 2 mm de raiz. Os dados foram submetidos à análise de variância e as médias comparadas pelo teste de Tukey a 5% de probabilidade. A escarificação do tegumento com ácido sulfúrico durante 60 minutos, foi ideal para as sementes de Senna alata, por proporcionar maiores valores na porcentagem e velocidade de germinação. A germinação ocorre entre 15 e 40ºC, sendo consideradas fotoblásticas neutras entre 20 e 40ºC e fotoblásticas negativas preferenciais a 15ºC. O melhor desempenho germinativo foi obtido nas temperaturas de 25, 30 e 35ºC, onde ocorreram maior porcentagem e velocidade de germinação.
Resumo:
Bending fatigue tests were carried out to clarify the effects of heat treatment parameters: temperature and time after cadmium electroplating on a high strength steel, to avoid hydrogen embrittlement. Temperatures heat of 190 degrees C, 230 degrees C, 250 degrees C and 300 degrees C at 3, 8 and 24 hours together with the base material electroplated, with and without heat treatment, resulted in 14 conditions studied with respect to fatigue behaviour. Statistical data analysis was performed to identify the best combination temperature/time regarding fatigue strength of the ABNT 4340 steel and the results obtained revealed that the fatigue strength depend on temperature/time conditions.
Resumo:
The running velocities associated to lactate minimum (V-lm), heart rate deflection (V-HRd), critical velocity (CV), 3000 M (V-3000) and 10000 m performance (V-10km) were compared. Additionally the ability of V-lm and VHRd on identifying sustainable velocities was investigated.Methods. Twenty runners (28.5 +/- 5.9 y) performed 1) 3000 m running test for V3000; 2) an all-out 500 in sprint followed by 6x800 m incremental bouts with blood lactate ([lac]) measurements for V-lm; 3) a continuous velocity-incremented test with heart rate measurements at each 200 m for V-HRd; 4) participants attempted to 30 min of endurance test both at V-lm(ETVlm) and V-HRd(ETVHRd). Additionally, the distance-time and velocity-1/time relationships produced CV by 2 (500 m and 3000 m) or 3 predictive trials (500 m, 3000 m and distance reached before exhaustion during ETVHRd), and a 10 km race was recorded for V-10km.Results. The CV identified by different methods did not differ to each other. The results (m(.)min(-1)) revealed that V-.(lm) (281 +/- 14.8)< CV (292.1 +/- 17.5)=V-10km (291.7 +/- 19.3)< V-HRd (300.8 +/- 18.7)=V-3000 (304 +/- 17.5) with high correlation among parameters (P < 0.001). During ETVlm participants completed 30 min of running while on the ETVHRd they lasted only 12.5 +/- 8.2 min with increasing [lac].Conclusion. We evidenced that CV and Vim track-protocols are valid for running evaluation and performance prediction and the parameters studied have different significance. The V-lm reflects the moderate-high intensity domain (below CV), can be sustained without [lac] accumulation and may be used for long-term exercise while the V-HRd overestimates a running intensity that can be sustained for long-time. Additionally, V-3000 and V-HRd reflect the severe intensity domain (above CV).
Resumo:
Flotation has been widely used in studies of recent foraminifera in order to concentrate tests and save time during picking. In this paper, four flotation agents with different densities were compared: (1) trichloroethylene, TCE (C2HCl3), with a density of 1.46 g mL(-1); (2) sodium nitrate/sodium thiosulfate solution, SNT (NaNO3 + Na2O3S2 center dot 5H(2)O), with a density of 1.46 g mL(-1); (3) zinc chloride Solution, ZC (ZHCl(2)), with a density of 1.70 g mL(-1); and (4) sodium polytungstate solution, SPT (3Na(2)WO(4) center dot 9WO(3) center dot 5H(2)O), with a density of 2.50 g mL(-1). Comparison was carried out by means of qualitative and quantitative data. Results showed that ZC and SPT were the best flotation agents, recovering 91% and 96% of the total tests, respectively, whereas TCE and SNT recovered 59.1% and 72.8%, respectively. Both quantitative and qualitative results significantly improved with a higher density of the flotation liquid. Therefore, substitution of TCE with ZC or SPT solutions is strongly encouraged, because they are, additionally, less harmful to health and the environment. ZC is the most cost-effective, since its results were not significantly different from those of the SPT treatment. Carbon tetrachloride (CCl4) was not considered in this comparative study, because it has been banned in many countries and it is highly harmful to health and the environment.
Resumo:
The dilatometer test results have been lately applied in foundation design for prediction of settlement and bearing capacity problems. The equipment, its calibration, test procedures and test data interpretation are simple. These advantages seem to explain the increasing use of the dilatometer (DMT) test as a routine technique for subsoil investigation. The DMT test boreholes were carried out on the grounds of the National Research Council (NRC) in Ottawa. Several test results based on laboratory, and other in situ tests available in the literature for the Leda clay deposit in Ottawa area were used to provide correlations between geotechnical properties and soil index parameters as proposed by Marchetti (1980). More appropriated relationships, even though preliminaries, are presented for the crust layer.
Resumo:
In order to study laboratorial aspects of beef cow mortality, a syndrome popularly known as ''doenca da vaca caida'', examens were made of blood, cerebrospinal fluid, serum, bone and liver samples from 32 naturally affected 4 to 9 year old cows, 27 belonging to the Nellore breed and 5 were crossbred Nellore, all originating from farms located in municipalities near Botucatu, State of São Paulo. Laboratory determinations were analysed by descriptive statistics and included hematological values, total plasma protein, plasma fibrinogen, cerebrospinal fluid analysis, and concentration measurements of serum calcium, phosphorus, magnesium, sodium, potassium, chloride, total protein, albumin, globulin, alkaline phosphatase, aspartate aminotransferase, gama-glutamyltransferase and creatine kinase activities, included bone ash percentage and concentrations of calcium, phosphorus and magnesium, and also hepatic levels of copper, zinc, iron, manganese and cobalt. In addition, mouse bioassays and complement micro-fixation tests were performed to detect botulinum toxins in liver samples. The results indicated leukocytosis (13,3+/-3,9 x10(3)/mm(3)) with neutrophilia (8,9+/-3,2 x10(3)/mm(3)), hypocalcemia (7,8+/-1,7mg/dl), hypophosphatemia (3,6+/-1,6mg/dl), hypoalbuminemia (2,9+/-0,9g/dl), increased creatine kinase activity (691,0+/-829,7 UI/1), and reduced ash percentage (60,3+/-1,9%) and low phosphorus (17,2+/-0,4%) in bone. The other values were ail within normal limits. The diagnosis of botulism, involving type C and D toxins, was confirmed as the cause of the mortality in the region of study, what is strongly consistent with the other laboratorial findings.
Resumo:
Objectives. Evaluate the flexural strength (sigma) and subcritical crack growth (SCG) under cyclic loading of glass-infiltrated alumina-based (IA, In-Ceram Alumina) and zirconia-reinforced (IZ, In-Ceram Zirconia) ceramics, testing the hypothesis that wet environment influences the SCG of both ceramics when submitted to cyclic loading.Methods. Bar-shaped specimens of IA (n = 45) and IZ ( n = 45) were fabricated and loaded in three-point bending (3P) in 37 degrees C artificial saliva (IA(3P) and IZ(3P)) and cyclic fatigued (F) in dry (D) and wet (W) conditions (IA(FD), IA(FW), IZ(FD), IZ(FW)). The initial sigma and the number of cycles to fracture were obtained from 3P and F tests, respectively. Data was examined using Weibull statistics. The SCG behavior was described in terms of crack velocity as a function of maximum stress intensity factor (K(Imax)).Results. The Weibull moduli (m = 8) were similar for both ceramics. The characteristic strength (sigma(0)) of IA and IZ was and 466 MPa 550 MPa, respectively. The wet environment significantly increased the SCG of IZ, whereas a less evident effect was observed for IA. In general, both ceramics were prone to SCG, with crack propagation occurring at K(I) as low as 43-48% of their critical K(I). The highest sigma of IZ should lead to longer lifetimes for similar loading conditions.Significance. Water combined with cyclic loading causes pronounced SCG in IZ and IA materials. The lifetime of dental restorations based on these ceramics is expected to increase by reducing their direct exposure to wet conditions and/or by using high content zirconia ceramics with higher strength. (C) 2010 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)