911 resultados para Separation of variables


Relevância:

90.00% 90.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

90.00% 90.00%

Publicador:

Resumo:

This paper is the result of the Masters dissertation studying the role and history of scientific communication, especially the changes that have occurred after the appearance of electronic communication and computer networks. This study showed that hypertext systems are increasingly being used in the scientific and academic world in the production of electronic journals; this makes it possible for the user to rapidly access information in their area. However, these systems need to be improved to help the user during search and access to information. Both printed journals migrating to electronic media, and the exclusively electronic journals should present the current quality indicators. The attempt was made to discover whether characteristics related to printed journals are being maintained in their electronic counterparts. For this, a prototype model was developed to analyze the structure of electronic scientific journals; it composes 14 criteria expressing aspects of quality for these journals. It includes elements of Website Information Architecture and those already in place in printed scientific journals in order to ensure that basic functions - archiving and dissemination - are maintained in electronic publishing. Each criterion consists of variables, which measure the maintenance of these functions both in the migrating printed journals and the exclusively electronic ones. This prototype model was used to analyze Ciência da Informação On-line and DataGramaZero - Revista de Ciência da Informação. Results indicate that this model is able to find out if the basic functions of archiving and dissemination are being maintained in electronic journals. Therefore, its implementation is justified in electronic journals. The model can help librarians, authors, and users of electronic journals to identify quality journals, and assist editors in developing their projects. The material from the study may be included in the preservice and inservice education of Information Science professionals and to support editors of scientific journals.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The present work had as objective to apply an experimental planning aiming at to improve the efficiency of separation of a new type of mixer-settler applied to treat waste water contaminated with oil. An unity in scale of laboratory, was installed in the Post-graduation Program of Chemical Engineering of UFRN. It was constructed in partnership with Petrobras S.A. This called device Misturador-Decantador a Inversão de Fases (MDIF) , possess features of conventional mixer-settler and spray column type. The equipment is composed of three main parts: mixing chamber; chamber of decantation and chamber of separation. The efficiency of separation is evaluated analyzing the oil concentrations in water in the feed and the output of the device. For the analysis one used the gravimetric method of oil and greases analysis (TOG). The system in study is a water of formation emulsified with oil. The used extractant is a mixture of Turpentine spirit hydro-carbons, supplied for Petrobras. It was applied, for otimization of the efficiency of separation of the equipment, an experimental planning of the composite central type, having as factorial portion fractionary factorial planning 2 5-2, with the magnifying of the type star and five replications in the central point. In this work, the following independents variables were studied: contents of oil in the feed of the device; volumetric ratio (O/A); total flowrate ; agitation in the mixing chamber and height of the organic bed. Minimum and maximum limits for the studied variables had been fixed according previous works. The analysis of variance for the equation of the empirical model, revealed statistically significant and useful results for predictions ends. The variance analysis also presented the distribution of the error as a normal distribution and was observed that as the dispersions do not depend on the levels of the factors, the independence assumption can be verified. The variation around the average is explained by 98.98%, or either, equal to the maximum value, being the smoothing of the model in relation to the experimental points of 0,98981. The results present a strong interaction between the variable oil contents in the feed and agitation in the mixing chamber, having great and positive influence in the separation efficiency. Another variable that presented a great positive influence was the height of the organic bed. The best results of separation efficiency had been obtained for high flowrates when associates the high oil concentrations and high agitation. The results of the present work had shown excellent agreement with the results carried out through previous works with the mixer-settler of phase inversion

Relevância:

90.00% 90.00%

Publicador:

Resumo:

In recent decades, the generation of solid and liquid waste has increased substantially due to increased industrial activity that is directly linked to economic growth. For that is the most efficient process, it is inevitable generation of such wastes. In the oil industry, a major waste generated in oil exploration is produced water, which due to its complex composition and the large amount generated, has become a challenge, given the restrictions imposed by environmental laws regarding their disposal, making if necessary create alternatives for reuse or treatment in order to reduce the content of contaminants and reduce the harmful effects to the environment. This water can be present in free form or emulsified with the oil, when in the form of an emulsion of oil-water type, it is necessary to use chemicals to promote the separation and flotation is the treatment method which has proved to be more efficient, for it can remove much of the emulsified oil when compared to other methods. In this context, the object of this work was to study the individual effects and interactions of some physicochemical parameters of operations, based on previous work to a flotation cell used in the separation of synthetic emulsion oil / water in order to optimize the efficiency of the separation process through of the 24 full factorial design with center point. The response variables to evaluate the separation efficiency was the percentage of color and turbidity removal. The independent variables were: concentration of de-emulsifying, oil content in water, salinity and pH, these being fixed, minimum and maximum limits. The analysis of variance for the equation of the empirical model, was statistically significant and useful for predictive purposes the separation efficiency of the floater with R2 > 90%. The results showed that the oil content in water and the interaction between the oil content in water and salinity, showed the highest values of the estimated effects among all the factors investigated, having great and positive influence on the separation efficiency. By analyzing the response surface was determined maximum removal efficiency above 90% for both measured for turbidity as a measure of color when in a saline medium (30 g/L), the high oil concentrations (306 ppm) using low concentrations of de-emulsifying (1,1 ppm) and at pH close to neutral

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The drilling fluid used to assist in the drilling operation of oil wells, accumulates solids inherent in the formation as it is circulated in the well, interfering in the fluid performance during operation. It is discarded after use. The disposal of these fluids causes one of the most difficult environmental problems in the world. This study aims to promote liquid phase separation of drilling fluids, which have circulated in oil wells, and enable this recovered liquid to formulate a new fluid. For this, non-ionic surfactants were used in order to select the best outcome in phase separation. Five real water-based drilling fluids were utilized, which were collected directly from the fields of drilling oil wells, classified as polymeric fluids. The methodology used consisted in combining the fluid with surfactant and then subjecting it to a process of centrifugation or decantation. The decantating tests were scheduled through experimental planning 23 and 32, using as variables the percentage (%) of surfactant utilized and the stirring time in minutes. The surfactants used were ethoxylated nonylphenol and lauryl alcohol ethoxylated with different degrees of ethoxylation. Phase separation was monitored first by tests of stability, and subsequently by the height of the interface in beakers of 100 mL. The results showed that from the surfactants studied, the lauryl alcohol ethoxylated with 3 ethoxylation units has been the most effective in the phase separation process of the drilling fluids tested. The statistical tool used was of great industrial value regarding the programming phase separation in drilling fluids. In conclusion, the liquid phase separated using surfactant can be reused for a new formulation of drilling fluid with similar properties of a new fluid, assuring its efficiency. And in the resulting analysis it is also suggested that the adsorption is the mechanism that leads the phase separation, with surfactant adsorbing in the active solids

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The Plant of Generic Values (PVG) is part of the cadastral system of a city hall and is about an important document or support for the urban planning. For its conception some stages are necessary, amongst which the most remarkable: the collection of information and the proper evaluation. A norm number 14653-2 of the ABNT recommends the application of the comparative method of data of market for the evaluation of lands values, but not always this procedure is possible due to absence of significant samples, as in urban areas densely constructed the real estate transactions is restricted, practically, to remarkable are the constructed ones. Thus, this work aims at showing which one, the sources of these data and the problematic found to get them. Moreover, a method is presented, that is an alternative to get the values of lands in the regions where yhere is scarcity of these data, so as to make the results beter. This method deals with the junction of other methods of evaluation to the comparative method of market data. The use of the methodology provided better performance in the procedures, having as a consequence bigger uniformity between the data, that is, the value of evaluation and the value of market equalize. Besides, the separation of the area of work in zones of homogeneous data made possible to generate more models, making use of fewes variables, due to the similarity among the data.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

A simple and rapid method was developed for the determination of amfepramone hydrochloride, fenprorex, and diazepam in capsules using high performance liquid chromatography (HPLC) with UV detection. This procedure provided conditions for the separation of the active ingredient from the complex matrices of the dosage forms by extraction in methanol. Isocratic reversed phase chromatography was performed using acetonitrile, methanol, and aqueous 0,1% ammonium carbonate (50:10:40) as a mobile phase, LiChrospher 100 RP 18 column (125 x 5 mm id, 5 mu m), a column temperature of 25 +/- 1 degrees C and detection at 230 nm.The calibration curves were linear over a wide concentration range (20-2000 mu g.mL(-1) to amfepramone hydrochloride, 8-800 mu g.mL(-1) to fenproporex, and 4-200 mu g.mL(-1) to diazepam) and good analytical recovery (87.1 to 107.8%) was obtained. The method is accurate and precise, as well as having advantages such as simplicity and short duration of analysis. Twenty samples of pharmaceutical preparations labelled as natural products were analysed. Anorectics and diazepam, were detected in 40% of the samples.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

A sensitive, accurate, reliable and easy method was developed for the quantification of oxamniquine in capsules using high-performance liquid chromatography (HPLC) with UV detection. This technique provided conditions for the separation of the active ingredient from the dosage form by extraction in methanol. Isocratic reversed phase chromatography was performed using methanol, water, and triethanolamine (60:40:0.099, v/v/w) (System C) or methanol, acetonitrile, water and formic acid (40:30:30:0.083, v/v/w) (System D) as mobile phase, a stainless steel column (125 x 4 mm i.d., 5 mum) filled with LiChrospher 100 RP-18 (Merck), column temperature of 28 +/- 2 degreesC and detection at 260 nm. The calibration curves were linear over a wide concentration range (1.0-20.0 mug ml(-1) of oxamniquine) to the Systems C and D with good correlation factor (0.9990 and 0.9982, respectively). The average content obtained were 100.1 +/- 1.5% (System C) and 102.4 +/- 0.8% (System D). The presence of lactose, starch, magnesium stearate and sodium laurylsulphate did not interfere in the results of the analysis. The above findings showed the proposed method to be both simple and added advantage of allowing for fast analysis. (C) 2001 Elsevier B.V. B.V. All rights reserved.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Simple and rapid procedures were developed for the quantification of amfepramone hydrochloride and diazepam and mazindol and diazepam in tablets using high performance liquid chromatography (HPLC) with UV detection. These techniques provided conditions for the separation of each active ingredient from the complex matrices of the dosage forms by dilution or extraction in methanol. Isocratic reversed phase chromatography was performed using acetonitrile, methanol, and aqueous 0,1% ammonium carbonate (70:10:20, v/v/v) as a mobile phase, Radial-Pak C-18 column (100 x 8 mm id, 4 mu m), a column temperature of 25+/-1 degrees C and detection at 255 nm. The calibration curves were linear over a wide concentration range (100-1000 mu g.mL(-1) to amfepramone hydrochloride and mazindol and 10-100 mu g.mL(-1) to diazepam) with good correlation factors of 0.9978, 0.9956 and 0.9997 for amfepramone hydrochloride, mazindol, and diazepam, respectively.Mean recoveries obtained from the two kinds of samples ranged from 83.2 to 102.5%, with coefficients of variation ranging from 1.0 to 6.1.These results demonstrated the efficiency of the proposed methods, as well as advantages such as simplicity and short duration of analysis.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)