974 resultados para SUPRAMOLECULAR SOFT MATERIALS
Resumo:
OBJECTIVE: The purpose of the present study was to submit the same materials that were tested in the round robin wear test of 2002/2003 to the Alabama wear method. METHODS: Nine restorative materials, seven composites (belleGlass, Chromasit, Estenia, Heliomolar, SureFil, Targis, Tetric Ceram) an amalgam (Amalcap) and a ceramic (IPS Empress) have been submitted to the Alabama wear method for localized and generalized wear. The test centre did not know which brand they were testing. Both volumetric and vertical loss had been determined with an optical sensor. After completion of the wear test, the raw data were sent to IVOCLAR for further analysis. The statistical analysis of the data included logarithmic transformation of the data, the calculation of relative ranks of each material within each test centre, measures of agreement between methods, the discrimination power and coefficient of variation of each method as well as measures of the consistency and global performance for each material. RESULTS: Relative ranks of the materials varied tremendously between the test centres. When all materials were taken into account and the test methods compared with each other, only ACTA agreed reasonably well with two other methods, i.e. OHSU and ZURICH. On the other hand, MUNICH did not agree with the other methods at all. The ZURICH method showed the lowest discrimination power, ACTA, IVOCLAR and ALABAMA localized the highest. Material-wise, the best global performance was achieved by the leucite reinforced ceramic material Empress, which was clearly ahead of belleGlass, SureFil and Estenia. In contrast, Heliomolar, Tetric Ceram and especially Chromasit demonstrated a poor global performance. The best consistency was achieved by SureFil, Tetric Ceram and Chromasit, whereas the consistency of Amalcap and Heliomolar was poor. When comparing the laboratory data with clinical data, a significant agreement was found for the IVOCLAR and ALABAMA generalized wear method. SIGNIFICANCE: As the different wear simulator settings measure different wear mechanisms, it seems reasonable to combine at least two different wear settings to assess the wear resistance of a new material.
Resumo:
Content and Language Integrated Learning (CLIL)Materials in Chemistry and English following the principles of CLIL / Content-based Instruction and Task-based Learning
Resumo:
The present research project was designed to determine thermal properties, such as coefficient of thermal expansion (CTE) and thermal conductivity, of Iowa concrete pavement materials. These properties are required as input values by the Mechanistic-Empirical Pavement Design Guide (MEPDG). In this project, a literature review was conducted to determine the factors that affect thermal properties of concrete and the existing prediction equations for CTE and thermal conductivity of concrete. CTE tests were performed on various lab and field samples of portland cement concrete (PCC) at the Iowa Department of Transportation and Iowa State University. The variations due to the test procedure, the equipment used, and the consistency of field batch materials were evaluated. The test results showed that the CTE variations due to test procedure and batch consistency were less than 5%, and the variation due to the different equipment was less than 15%. Concrete CTE values were significantly affected by different types of coarse aggregate. The CTE values of Iowa concrete made with limestone+graval, quartzite, dolomite, limestone+dolomite, and limestone were 7.27, 6.86, 6.68, 5.83, and 5.69 microstrain/oF (13.08, 12.35, 12.03, 10.50, and 10.25 microstrain/oC), respectively, which were all higher than the default value of 5.50 microstrain/oF in the MEPDG program. The thermal conductivity of a typical Iowa PCC mix and an asphalt cement concrete (ACC) mix (both with limestone as coarse aggregate) were tested at Concrete Technology Laboratory in Skokie, Illinois. The thermal conductivity was 0.77 Btu/hr•ft•oF (1.33 W/m•K) for PCC and 1.21 Btu/hr•ft•oF (2.09 W/m•K) for ACC, which are different from the default values (1.25 Btu/hr•ft•oF or 2.16 W/m•K for PCC and 0.67 Btu/hr•ft•oF or 1.16 W/m•K for ACC) in the MEPDG program. The investigations onto the CTE of ACC and the effects of concrete materials (such as cementitious material and aggregate types) and mix proportions on concrete thermal conductivity are recommended to be considered in future studies.
Resumo:
The thermal properties of concrete materials, such as coeffi cient of thermal expansion (CTE), thermal conductivity, and heat capacity, are required by the MEPDG program as the material inputs for pavement design. However, a limited amount of test data is available on the thermal properties of concrete in Iowa. The default values provided by the MEPDG program may not be suitable for Iowa concrete, since aggregate characteristics have signifi cant infl uence on concrete thermal properties.
Resumo:
Els objectius de partida d’aquesta recerca han estat l’estudi de les tècniques i dels materials dela pintura mural medieval a Catalunya, tot i establint paraŀlelismes amb el coneixement que ensaporten els tractats tècnics d’època medieval. S’ha revisat també l’estat actual del coneixement sobre les tècniques d’alguns conjunts de pintura mural aragonesos i d’àmbit europeu.
Resumo:
The resilient modulus (MR) input parameters in the Mechanistic-Empirical Pavement Design Guide (MEPDG) program have a significant effect on the projected pavement performance. The MEPDG program uses three different levels of inputs depending on the desired level of accuracy. The primary objective of this research was to develop a laboratory testing program utilizing the Iowa DOT servo-hydraulic machine system for evaluating typical Iowa unbound materials and to establish a database of input values for MEPDG analysis. This was achieved by carrying out a detailed laboratory testing program designed in accordance with the AASHTO T307 resilient modulus test protocol using common Iowa unbound materials. The program included laboratory tests to characterize basic physical properties of the unbound materials, specimen preparation and repeated load triaxial tests to determine the resilient modulus. The MEPDG resilient modulus input parameter library for Iowa typical unbound pavement materials was established from the repeated load triaxial MR test results. This library includes the non-linear, stress-dependent resilient modulus model coefficients values for level 1 analysis, the unbound material properties values correlated to resilient modulus for level 2 analysis, and the typical resilient modulus values for level 3 analysis. The resilient modulus input parameters library can be utilized when designing low volume roads in the absence of any basic soil testing. Based on the results of this study, the use of level 2 analysis for MEPDG resilient modulus input is recommended since the repeated load triaxial test for level 1 analysis is complicated, time consuming, expensive, and requires sophisticated equipment and skilled operators.
Resumo:
El pou D 18, situat a la part sud-oest de la zona coneguda del forum de Pollentia, fou amortitzat en el segon quart del segle 1 a.C. EIs materials que formaven part del farciment constitueixen un conjunt tancat representatiu sobretot deIs tipus ceramics locals i d'importació utilitzats en aquesta epoca. El volum principal d'importacions correspon als productes italics, seguits a gran distancia pels materials púnics, iberics i egeus.
Resumo:
Mitjançant la intervenció d'Oriol Mercadal, responsable del Museu Cerda de Puigcerda, han arribat a les nostres mans tres eines lítiques treballades per 1'home, procedents d'un jaciment cereta. La nostra intenció és tan soIs publicar els materials i reflexionar arran de la possible cronologia d'aquestes eines per paral-lels amb altres materials semblants i propers geograficament parlant.
Resumo:
El present treball es proposa l'estudi fonnal de I'habitat construtt amb materials duradors a Catalunya durant el Bronze Final i la Primera Edat del Ferro, i se centra en l'aninisi dels materials i tecniques de construcció emprats, així com en l' estructura de la casa (planta, dimensions, superfície). Els elements definidors d'aquests habitacles en els períodes estudiats consisteixen en l'ús sistematic de la pedra i la terra com a materials de construcció i la disposició d'habitacions de planta rectangular compartint parets mitgeres, amb poca compartimentació interna i pocs agenc¡:aments al seu interior (llar, forn, banquetes). Les dimensions maximes d'aquestes habitacions no superen, per nonna general, els 20 metres quadrats. La unifonnitat d'aquestes construccions, unida a la poca compartimentació de l'espai, suggereix que ens trobem davant una arquitectura poc especialitzada, que podria correspondre a una societat amb una organització socio-política poc complexa.
Resumo:
El jaciment del Castellot de la Roca Roja (Benifallet, Baix Ebre) es localitza a la riba esquerra del riu Ebre, sobre una formac ió rocallosa de relleus molt abruptes, només accessible per I' extrem septentrional, on es va construir un fossat i una muralla de doble parament que s'adossa a una torre quadranguiar. Sens dubte, la se va posició és immillorable per tal d'exercir el control del pas pel riu.
Resumo:
El present treball ofereix una revisió de les pintures murals de la basílica de «Es Cap des Port» (Fornells, Menorca), així com un estudi de caracterització arqueometrica deIs materials i tecniques per microscopia optica, tant amb lupa binocular com amb micro scopi petrografic mitjanliant ¡¡lmina prima, difracció de raigs X i microscopia electronica de rastreig. Els resultats han permes identificar els pigments emprats, així com la seva tecnica d'aplicació. Igua!ment, han permes caracteritzar els morters i han desvelat l' existencia de dos tipus diferents de suporto Malgrat aquestes diferencies en els morters, els pigments són sempre els mateixos per a tots els conjunts pictorics caracteritzats.
Resumo:
Background And Objectives: Isolated limb perfusion with TNF-alpha and melphalan (TM-ILP) is a limb salvage therapy for non-resectable soft tissue sarcomas (STS) of the extremities. It is indicated for patients for whom amputation or debilitating surgery is the only alternative. It can be used either as an exclusive therapy (in palliation) or as a neo-adjuvant treatment, followed by marginal resection of tumor remnants with minimal functional impairment. Methods: Between February 1992 and March 2006, 57 TM-ILPs were performed on 51 patients with 88% high grade and 84% advanced stage tumors. Results: Mean follow-up is 38.9 months (4-159, median 22 months). Twenty-one percent patients had significant early complications, with 3 major re-operations, and 23% suffered long-lasting complications. Complete response was observed in 25%, partial response in 42%, stable disease in 14% and progressive disease in 14%. Resection of the tumor remnants was possible in 65%. A complementary treatment was necessary in 31%, mostly radiation therapy. A local recurrence was observed in 35%, after a mean of 20.3 months (2-78), and distant relapse was seen in 45%, after a mean of 13.4 months (5-196). Mean Disease-free survival was 14.9 months, and overall 5-year-survival 43.5%. Amputation rate at 5 years was 24%. Conclusions: TM-ILP is a conservative treatment with a high complications rate, but it can be successful even for the most severe STS of extremities. As a consequence the limb can be spared from amputation or debilitating surgery on the long term in about 75% of patients
Resumo:
Selostus: Pohjois-Euroopan silikaattisten kalkitusaineiden reaktiivisuus astiakoemenetelmällä ja kahdella pH-staattisella menetelmällä arvioituna
Resumo:
The goal of this work is to develop a method to objectively compare the performance of a digital and a screen-film mammography system in terms of image quality. The method takes into account the dynamic range of the image detector, the detection of high and low contrast structures, the visualisation of the images and the observer response. A test object, designed to represent a compressed breast, was constructed from various tissue equivalent materials ranging from purely adipose to purely glandular composition. Different areas within the test object permitted the evaluation of low and high contrast detection, spatial resolution and image noise. All the images (digital and conventional) were captured using a CCD camera to include the visualisation process in the image quality assessment. A mathematical model observer (non-prewhitening matched filter), that calculates the detectability of high and low contrast structures using spatial resolution, noise and contrast, was used to compare the two technologies. Our results show that for a given patient dose, the detection of high and low contrast structures is significantly better for the digital system than for the conventional screen-film system studied. The method of using a test object with a large tissue composition range combined with a camera to compare conventional and digital imaging modalities can be applied to other radiological imaging techniques. In particular it could be used to optimise the process of radiographic reading of soft copy images.