970 resultados para SAMPLING METHODS
Resumo:
OBJECTIVE: Use of analgesics has been increasingly recognized as a major public health issue with important consequences in Turkey. The objective of the study was to determine the prevalence and patterns of analgesics usage and associated factors in adults with pain complaints. METHODS: A cross-sectional study was conducted in 15 cities selected from five demographic regions in Turkey. The study sample population comprised 1.909 adults 18-65 age groups suffering from pain. The sampling method was multi-step stratified weighted quota-adjusted sampling. Data were collected by face-to-face interviews using a semi-structured survey questionnaire consisting of 28 questions. Odds ratios were produced by logistic regression analyses. RESULTS: The prevalence of analgesic use was 73.1%, and it was higher in females (75.7%; p<0.05), in subjects 45-54 years (81.4%; p<0.05), in subjects in rural areas (74.6%; p<0.05), in subjects in northern region (84.3%; p<0.05), in illiterate subjects (79.1%; p>0.05), and in subjects of lower socioeconomic status (74.1%; p>0.05). One in ten of the participants used non-prescription analgesics. Non-prescription analgesics were more prevalent among the 55-65 age groups (18.1%; p<0.05), among female (11.6%; p>0.05), among the urban population (10.7%; p>0.05), and in subjects of lower middle socioeconomic status (13.2%; p<0.05). Logistic regression showed statistically significant ORs only for age groups, duration of education, socioeconomic status, and demographic regions (p<0.05). CONCLUSIONS: The results showed that the prevalence of analgesic use and prescription analgesic use is high in Turkey, and their use is related to sociodemographic characteristics.
Resumo:
OBJECTIVE:To analyze factors associated with cervical cancer screening failure. METHODS:Population-based cross-sectional study with self-weighted two-stage cluster sampling conducted in the cities of Fortaleza (Northeastern Brazil) and Rio de Janeiro (Southeastern Brazil) in 2002. Subjects were women aged 25-59 years in the last three years prior to the study. Data were analyzed through Poisson regression using a hierarchical model. RESULTS: The proportion of women who did not undergo the Pap smear test in Fortaleza and Rio de Janeiro was 19.1% (95% CI: 16.1;22.1) and 16.5% (95% CI: 14.1;18.9), respectively. Higher prevalence ratios of cervical cancer screening failure in both cities were seen among women with low education and low per capita income, old age, unmarried, who never underwent mammography, clinical breast examination, and blood glucose and cholesterol level testing. Smokers also had lower screening rates compared to non-smoker women and this difference was only statistically significant in Rio de Janeiro. CONCLUSIONS:The study findings point to the need of intervention focusing particularly women in worse socioeconomic conditions and access to healthcare, old-aged and unmarried. Education activities must prioritize screening of asymptomatic women and early diagnosis for symptomatic women and access to adequate diagnostic methods and treatment should be provided.
Resumo:
Dissertação de Mestrado, Biodiversidade e Biotecnologia Vegetal, 4 de Fevereiro de 2016, Universidade dos Açores.
Resumo:
Neste trabalho, apresentam-se e discutem-se os resultados da aplicação da técnica de amostragem linear de descontinuidades em faces expostas do maciço rochoso da pedreira granítica de S. Domingos Nº 2 (Fontelo, Armamar; N de Portugal). É, igualmente, utilizada informação sobre a rede de fracturação regional, obtida através da análise morfoestrutural de mapas topográficos e mapas geológicos. São ainda referidos os métodos utilizados no tratamento dos dados de terreno com o objectivo de definir as famílias de descontinuidades e de caracterizar estatísticamente a sua atitude, espaçamento e extensão. Os resultados obtidos são comparados, à mega escala e macro-escala, no sentido de averiguar a presença de um padrão de fracturação com dimensão multiescala. Esta abordagem foi refinada através da aplicação de Sistemas de Informação Geográfica. A aplicação desta técnica para a caracterização da compartimentação do maciço poderá contribuir para aperfeiçoar a gestão sustentável do georrecurso da pedreira de S. Domingos Nº 2 (Fontelo). O controlo geomecânico do desmonte do maciço rochoso é salientado com o intuito de uma abordagem de geo-engenharia integrada dos maciços rochosos.
Resumo:
Microarray allow to monitoring simultaneously thousands of genes, where the abundance of the transcripts under a same experimental condition at the same time can be quantified. Among various available array technologies, double channel cDNA microarray experiments have arisen in numerous technical protocols associated to genomic studies, which is the focus of this work. Microarray experiments involve many steps and each one can affect the quality of raw data. Background correction and normalization are preprocessing techniques to clean and correct the raw data when undesirable fluctuations arise from technical factors. Several recent studies showed that there is no preprocessing strategy that outperforms others in all circumstances and thus it seems difficult to provide general recommendations. In this work, it is proposed to use exploratory techniques to visualize the effects of preprocessing methods on statistical analysis of cancer two-channel microarray data sets, where the cancer types (classes) are known. For selecting differential expressed genes the arrow plot was used and the graph of profiles resultant from the correspondence analysis for visualizing the results. It was used 6 background methods and 6 normalization methods, performing 36 pre-processing methods and it was analyzed in a published cDNA microarray database (Liver) available at http://genome-www5.stanford.edu/ which microarrays were already classified by cancer type. All statistical analyses were performed using the R statistical software.
Resumo:
Mestrado em Engenharia Geotécnica e Geoambiente
Resumo:
A square wave voltammetric (SWV) method and a flow injection analysis systemwi th electrochemical detection (FIA-EC) using a glassy carbon electrode were evaluated for the determination of codeine in pharmaceutical preparations. The interference of several compounds, such as acetaminophen,guaiacol, parabens, ephedrine, acetylsalicylic acid and caffeine, that usually appear associated with codeine pharmaceutical preparations was studied. It was verified that these electroanalytical methods could not be used with acetaminophen present in the formulations and that with guaiacol, parabens or ephedrine present the use of the FIA-EC system was impracticable. A detection limit of 5 µmol L- 1 and a linear calibration range from 40 to 140 µmol L- 1 was obtained with the SWV method. For the flow injection analysis procedure a linear calibration range was obtained from 7 to 50 µmol L- 1 with a detection limit of 3 µmol L- 1 and the FIA-EC systemallowed a sampling rate of 115 samples per hour. The results obtained by the two methods, SWV and FIA-EC, were compared with those obtained using reference methods and demonstrated good agreement, with relative deviations lower than 4%.
Resumo:
Few analytical methods are currently available for determination of apomorphine, the active substance of a new oral formulation used in the treatment of erectile dysfunction. In this way a flow injection electrochemical method (FIA-EC) was developed for its quantification and applied to pharmaceutical dosage forms. Based in previous findings regarding the stability of apomorphine in borate buffer and after optimization of several analytical parameters a single channel flow injection manifold was set up that enables the determination of this drug over the concentration range of 3 to 16 µmol L-1 with a detection limit of 0.5 µmol L-1 at a sampling rateof 90 h-1. The simplicity and rapidity of the FIA-EC method used, its reproducibility and sensitivity make it suitable for quality control of pharmaceutical preparations of apomorphine intended for clinical use and research.
Resumo:
Chrysonilia sitophila is a common mould in cork industry and has been identified as a cause of IgE sensitization and occupational asthma. This fungal species have a fast growth rate that may inhibit others species’ growth causing underestimated data from characterization of occupational fungal exposure. Aiming to ascertain occupational exposure to fungi in cork industry, were analyzed papers from 2000 about the best air sampling method, to obtain quantification and identification of all airborne culturable fungi, besides the ones that have fast-growing rates. Impaction method don’t allows the collection of a representative air volume, because even with some media that restricts the growth of the colonies, in environments with higher fungal load, such as cork industry, the counting of the colonies is very difficult. Otherwise, impinger method permits the collection of a representative air volume, since we can make dilution of the collected volume. Besides culture methods that allows fungal identification trough macro- and micro-morphology, growth features, thermotolerance and ecological data, we can apply molecular biology with the impinger method, to detect the presence of non-viable particles and potential mycotoxin producers’ strains, and also to detect mycotoxins presence with ELISA or HPLC. Selection of the best air sampling method in each setting is crucial to achieve characterization of occupational exposure to fungi. Information about the prevalent fungal species in each setting and also the eventual fungal load it’s needed for a criterious selection.
Resumo:
Two analytical methods for the quality control of dihydrocodeine in commercial pharmaceutical formulations have been developed and compared with reference methods: a square wave voltammetric (SWV) method and a flow injection analysis system with electrochemical detection (FIA-EC). The electrochemical methods proposed were successfully applied to the determination of dihydrocodeine in pharmaceutical tablets and in oral solutions. These methods do not require any pretreatment of the samples, the formulation only being dissolved in a suitable electrolyte. Validation of the methods showed it to be precise, accurate and linear over the concentration range of analysis. The automatic procedure based on a flow injection analysis manifold allows a sampling rate of 115 determinations per hour.
Resumo:
The work presented describes the development and evaluation of two flow-injection analysis (FIA) systems for the automated determination of carbaryl in spiked natural waters and commercial formulations. Samples are injected directly into the system where they are subjected to alkaline hydrolysis thus forming 1-naphthol. This product is readily oxidised at a glassy carbon electrode. The electrochemical behaviour of 1-naphthol allows the development of an FIA system with an amperometric detector in which 1-naphthol determination, and thus measurement of carbaryl concentration, can be performed. Linear response over the range 1.0×10–7 to 1.0×10–5 mol L–1, with a sampling rate of 80 samples h–1, was recorded. The detection limit was 1.0×10–8 mol L–1. Another FIA manifold was constructed but this used a colorimetric detector. The methodology was based on the coupling of 1-naphthol with phenylhydrazine hydrochloride to produce a red complex which has maximum absorbance at 495 nm. The response was linear from 1.0×10–5 to 1.5×10–3 mol L–1 with a detection limit of 1.0×10–6 mol L–1. Sample-throughput was about 60 samples h–1. Validation of the results provided by the two FIA methodologies was performed by comparing them with results from a standard HPLC–UV technique. The relative deviation was <5%. Recovery trials were also carried out and the values obtained ranged from 97.0 to 102.0% for both methods. The repeatability (RSD, %) of 12 consecutive injections of one sample was 0.8% and 1.6% for the amperometric and colorimetric systems, respectively.
Resumo:
In order to combat a variety of pests, pesticides are widely used in fruits. Several extraction procedures (liquid extraction, single drop microextraction, microwave-assisted extraction, pressurized liquid extraction, supercritical fluid extraction, solid-phase extraction, solid-phase microextraction, matrix solid-phase dispersion, and stir bar sorptive extraction) have been reported to determine pesticide residues in fruits and fruit juices. The significant change in recent years is the introduction of the Quick, Easy, Cheap, Effective, Rugged, and Safe (QuEChERS) methods in these matrices analysis. A combination of techniques reported the use of new extraction methods and chromatography to provide better quantitative recoveries at low levels. The use of mass spectrometric detectors in combination with liquid and gas chromatography has played a vital role to solve many problems related to food safety. The main attention in this review is on the achievements that have been possible because of the progress in extraction methods and the latest advances and novelties in mass spectrometry, and how these progresses have influenced the best control of food, allowing for an increase in the food safety and quality standards.
Resumo:
Bread is consumed worldwide by man, thus contributing to the regular ingestion of certain inorganic species such as chloride. It controls the blood pressure if associated to a sodium intake and may increase the incidence of stomach ulcer. Its routine control should thus be established by means of quick and low cost procedures. This work reports a double- channel flow injection analysis (FIA) system with a new chloride sensor for the analysis of bread. All solutions are prepared in water and necessary ionic strength adjustments are made on-line. The body of the indicating electrode is made from a silver needle of 0.8 mm i.d. with an external layer of silver chloride. These devices were constructed with different lengths. Electrodes of 1.0 to 3.0 cm presented better analytical performance. The calibration curves under optimum conditions displayed Nernstian behaviour, with average slopes of 56 mV decade-1, with sampling rates of 60 samples h-1. The method was applied to analyze several kinds of bread, namely pão de trigo, pão integral, pão de centeio, pão de mistura, broa de milho, pão sem sal, pão meio sal, pão-de-leite, and pão de água. The accuracy and precision of the potentiometric method were ascertained by comparison to a spectrophotometric method of continuous segmented flow. These methods were validated against ion-chromatography procedures.
Resumo:
The state of the art of voltammetric and amperometric methods used in the study and determination of pesticides in crops, food, phytopharmaceutical products, and environmental samples is reviewed. The main structural groups of pesticides, i.e., triazines, organophosphates, organochlorides, nitrocompounds, carbamates, thiocarbamates, sulfonylureas, and bipyridinium compounds are considered with some degradation products. The advantages, drawbacks, and trends in the development of voltammetric and amperometric methods for study and determination of pesticides in these samples are discussed.
Resumo:
Mestrado em Tecnologia de Diagnóstico e Intervenção Cardiovascular