994 resultados para Reduced topologies


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The possibility of reducing the concentration of the working solution used in the tetrazolium test for peanut seeds (Arachis hypogaea L.) with or without seedcoats was studied. Tetrazolium solutions of different concentrations (0.05%, 0.075% and 0.1%) were tested at the temperatures of 35 and 40 degrees C, for determining the time needed for the seeds to reach proper staining. The efficiency of the selected treatments in evaluating the viability potential of the seeds was determined by comparing the results of the tetrazolium tests with those obtained by standard germination (using sand and rolled paper towel as substrata) and seedling emergence in the field tests. Staining the seeds without seedcoat in 0.05% tetrazolium solution for three hours at 40 degrees C yielded efficient results. on the other hand, reduced concentrations can be employed in the staining process of seeds with seedcoat; however, this method requires a higher consumption of tetrazolium salt, longer staining time as well as a higher ability and availability of time for embryo evaluation, since the cross-cutting of seeds is much more difficult in the presence of the seedcoat and the occurrence of damage to the outer surface of the cotyledons cannot be determined.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In ascending aorta aneurysms, there is an enlargement of the whole vessel, whereas aortic dissections (ADs) are characterized by the cleavage of the wall into 2 sheets at the external half. We searched if alterations in collagen could be related to these diseases. Sections of aortas from 14 case patients with acute dissections, 10 case patients with aneurysms, and 9 control subjects were stained with picrosirius. Slides were analyzed under polarized microscopy to evaluate the structure of collagen fibers. The proportion of collagen was calculated in each half of the medial layer by color detection in a computerized image analysis system. Collagen appearance under polarized light was consistent with collagenolysis. The mean collagen proportions at the inner and outer halves, respectively, were 0.50 +/- 0.13 and 0.40 +/- 0.08 in the control group, 0.20 +/- 0.10 and 0.18 +/- 0.12 in the AD group, and 0.33 +/- 0.12 and 0.19 +/- 0.12 in the aneurysm group. The AD (P < .01) and control (P = .04) groups had less collagen at the external half, no difference was found in the aneurysm group (P = .71). In both halves, there was less collagen in the case patients than in the control subjects (all P < .01), but at the internal half, the decrease was significantly greater in the case patients with aneurysms than in those with dissections (P = .03; at the external half, P = .99). Aortic dissections and aneurysms show a decrease in collagen content that could be related to a weakness of the wall underlying the diseases, but the locations of the decrease differ: in dissections, it is situated mostly at the external portion of the media (site of cleavage), whereas in aneurysms, it is more diffuse, consistent with the global enlargement. (c) 2008 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

HLA-G is a non-classic Human Leukocyte Antigen (HLA-G) Class I of low polymorphism and restricted tissue distribution that displays tolerogenic functions. In heart transplantation and in combined liver/renal allograft transplantation, the expression of HLA-G has been associated with a lower incidence of acute graft rejection episodes and absence of chronic dysfunction. Since the expression of HLA-G in renal biopsies has been investigated only in few patients who received a combined kidney and liver transplant, in this study we performed a cross-sectional study, systematically comparing the expression of HLA-G in post-transplanted renal grafts, stratifying patients according to the presence or absence of rejection.Patients and Methods: Seventy-three renal specimens (10 with acute rejection and 13 with chronic allograft nephropathy, and 50 with no signs of rejection) were immunohistochemically evaluated for HLA-G expression.Results: In the group as a whole, HLA-G molecules were detected in 40 cases (54.8%). Among specimens that presented HLA-G expression, 2 out of 40 (5%) exhibited acute rejection, 2 (5%) exhibited chronic allograft nephropathy, and the remaining 36 (90%) exhibited no signs of rejection. The comparison between patients with rejection and those without rejection showed that the expression of HLA-G was significantly increased in specimens exhibiting no signs of rejection (p<0.0001). Considering only patients with acute rejection, 8 out of 10 patients showed no HLA-G expression in their kidney biopsies when compared to patients exhibiting no signs of rejection and absence of HLA-G was observed in 14 out of 50 (p=0.0032). Similarly, considering only patients with chronic allograft nephropathy, absence of HLA-G expression was observed in I I out of 13 specimens, whereas in patients without rejection absence of HLA-G was observed in 14 out of 50 (p=0.003). Therapy with tacrolimus was significantly associated with the expression of HLA-G and a better graft prognosis. Conclusions: Our results suggest that HLA-G expression in the kidney allograft and the use of tacrolimus are associated with a lower frequency of acute renal rejection and chronic allograft nephropathy. (c) 2007 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents an experimental study on the life of abrasive discs in cut-off type operations with two conditions of cutting speed. The cutting time is shown with a comparative analysis of the cutting speed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The boson calculus formalism is used to construct realizations of basis states of irreducible representations of unitary groups taking as a paradigm the interacting boson models of atomic nuclei. These realizations, together with a theorem on plethysms for obtaining branching rules, allowed us to obtain a dimension formula for reduced plethysms. © 2005 IOP Publishing Ltd.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents the comparison of three topologies of multilevel inverters applied to drive an induction motor of 500 kVA/4.16 kV. The multilevel inverters analyzed are: a neutral point clamped inverter, a symmetrical cascaded multilevel inverter and a hybrid asymmetrical cascaded multilevel inverter. The performance indexes used in the comparison are total harmonic distortion, first order distortion factor, semiconductors power losses distribution and heat-sink volume. The comparison is developed with the purpose of finding the efficiency and the heat-sink volume where the three systems present the same output filter. ©2008 IEEE.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The pCT deals with relatively thick targets like the human head or trunk. Thus, the fidelity of pCT as a tool for proton therapy planning depends on the accuracy of physical formulas used for proton interaction with thick absorbers. Although the actual overall accuracy of the proton stopping power in the Bethe-Bloch domain is about 1%, the analytical calculations and the Monte Carlo simulations with codes like TRIM/SRIM, MCNPX and GEANT4 do not agreed with each other. A tentative to validate the codes against experimental data for thick absorbers bring some difficulties: only a few data is available and the existing data sets have been acquired at different initial proton energies, and for different absorber materials. In this work we compare the results of our Monte Carlo simulations with existing experimental data in terms of reduced calibration curve, i.e. the range - energy dependence normalized on the range scale by the full projected CSDA range for given initial proton energy in a given material, taken from the NIST PSTAR database, and on the final proton energy scale - by the given initial energy of protons. This approach is almost energy and material independent. The results of our analysis are important for pCT development because the contradictions observed at arbitrary low initial proton energies could be easily scaled now to typical pCT energies. © 2010 American Institute of Physics.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The GEANT4 simulations are essential for the development of medical tomography with proton beams pCT. In the case of thin absorbers the latest releases of GEANT4 generate very similar final spectra which agree well with the results of other popular Monte Carlo codes like TRIM/SRIM, or MCNPX. For thick absorbers, however, the disagreements became evident. In a part, these disagreements are due to the known contradictions in the NIST PSTAR and SRIM reference data. Therefore, it is interesting to compare the GEANT4 results with each other, with experiment, and with diverse code results in a reduced form, which is free from this kind of doubts. In this work such comparison is done within the Reduced Calibration Curve concept elaborated for the proton beam tomography. © 2010 IEEE.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This work presents the stage integration in power electronics converters as a suitable solution for solar photovoltaic inverters. The rated voltages available in Photovoltaic (PV) modules have usually low values for applications such as regulated output voltages in stand-alone or grid-connected configurations. In these cases, a boost stage or a transformer will be necessary. Transformers have low efficiencies, heavy weights and have been used only when galvanic isolation is mandatory. Furthermore, high-frequency transformers increase the converter complexity. Therefore, the most usual topologies use a boost stage and one inverter stage cascaded. However, the complexity, size, weight, cost and lifetime might be improved considering the integration of both stages. These are the expected features to turn attractive this kind of integrated structures. Therefore, some integrated converters are analyzed and compared in this paper in order to support future evaluations and trends for low power single-phase inverters for PV systems. © 2011 IEEE.