998 resultados para Pressure recommended


Relevância:

20.00% 20.00%

Publicador:

Resumo:

To evaluate the impact of noninvasive ventilation (NIV) algorithms available on intensive care unit ventilators on the incidence of patient-ventilator asynchrony in patients receiving NIV for acute respiratory failure. Prospective multicenter randomized cross-over study. Intensive care units in three university hospitals. Patients consecutively admitted to the ICU and treated by NIV with an ICU ventilator were included. Airway pressure, flow and surface diaphragmatic electromyography were recorded continuously during two 30-min periods, with the NIV (NIV+) or without the NIV algorithm (NIV0). Asynchrony events, the asynchrony index (AI) and a specific asynchrony index influenced by leaks (AIleaks) were determined from tracing analysis. Sixty-five patients were included. With and without the NIV algorithm, respectively, auto-triggering was present in 14 (22%) and 10 (15%) patients, ineffective breaths in 15 (23%) and 5 (8%) (p = 0.004), late cycling in 11 (17%) and 5 (8%) (p = 0.003), premature cycling in 22 (34%) and 21 (32%), and double triggering in 3 (5%) and 6 (9%). The mean number of asynchronies influenced by leaks was significantly reduced by the NIV algorithm (p < 0.05). A significant correlation was found between the magnitude of leaks and AIleaks when the NIV algorithm was not activated (p = 0.03). The global AI remained unchanged, mainly because on some ventilators with the NIV algorithm premature cycling occurs. In acute respiratory failure, NIV algorithms provided by ICU ventilators can reduce the incidence of asynchronies because of leaks, thus confirming bench test results, but some of these algorithms can generate premature cycling.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: Home blood pressure (BP) monitoring is recommended by several clinical guidelines and has been shown to be feasible in elderly persons. Wrist manometers have recently been proposed for such home BP measurement, but their accuracy has not been previously assessed in elderly patients. METHODS: Forty-eight participants (33 women and 15 men, mean age 81.3±8.0 years) had their BP measured with a wrist device with position sensor and an arm device in random order in a sitting position. RESULTS: Average BP measurements were consistently lower with the wrist than arm device for systolic BP (120.1±2.2 vs. 130.5±2.2 mmHg, P<0.001, means±SD) and diastolic BP (66.0±1.3 vs. 69.7±1.3 mmHg, P<0.001). Moreover, a 10 mmHg or greater difference between the arm and wrist device was observed in 54.2 and 18.8% of systolic and diastolic measures, respectively. CONCLUSION: Compared with the arm device, the wrist device with position sensor systematically underestimated systolic as well as diastolic BP. The magnitude of the difference is clinically significant and questions the use of the wrist device to monitor BP in elderly persons. This study points to the need to validate BP measuring devices in all age groups, including in elderly persons.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study aimed to compare foot plantar pressure distribution while jogging and running in highly trained adolescent runners. Eleven participants performed two constant-velocity running trials either at jogging (11.2 ± 0.9 km/h) or running (17.8 ± 1.4 km/h) pace on a treadmill. Contact area (CA in cm(2)), maximum force (F(max) in N), peak pressure (PP in kPa), contact time (CT in ms), and relative load (force time integral in each individual region divided by the force time integral for the total plantar foot surface, in %) were measured in nine regions of the right foot using an in-shoe plantar pressure device. Under the whole foot, CA, F(max) and PP were lower in jogging than in running (-1.2% [p<0.05], -12.3% [p<0.001] and -15.1% [p<0.01] respectively) whereas CT was higher (+20.1%; p<0.001). Interestingly, we found an increase in relative load under the medial and central forefoot regions while jogging (+6.7% and +3.7%, respectively; [p<0.05]), while the relative load under the lesser toes (-8.4%; p<0.05) was reduced. In order to prevent overloading of the metatarsals in adolescent runners, excessive mileage at jogging pace should be avoided.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Self-measurement of blood pressure at home is increasingly used in the diagnostic and therapeutic approach of hypertension. This technique allows multiple measurements of blood pressure away from the clinical setting, making it possible to improve the evaluation of cardiovascular risk. Recently new guidelines on the use of self-measured blood pressure have been made available by the European Society of Hypertension, as summarized in the present paper.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVES: To document the prevalence of asynchrony events during noninvasive ventilation in pressure support in infants and in children and to compare the results with neurally adjusted ventilatory assist. DESIGN: Prospective randomized cross-over study in children undergoing noninvasive ventilation. SETTING: The study was performed in a PICU. PATIENTS: From 4 weeks to 5 years. INTERVENTIONS: Two consecutive ventilation periods (pressure support and neurally adjusted ventilatory assist) were applied in random order. During pressure support (PS), three levels of expiratory trigger (ETS) setting were compared: initial ETS (PSinit), and ETS value decreased and increased by 15%. Of the three sessions, the period allowing for the lowest number of asynchrony events was defined as PSbest. Neurally adjusted ventilator assist level was adjusted to match the maximum airway pressure during PSinit. Positive end-expiratory pressure was the same during pressure support and neurally adjusted ventilator assist. Asynchrony events, trigger delay, and cycling-off delay were quantified for each period. RESULTS: Six infants and children were studied. Trigger delay was lower with neurally adjusted ventilator assist versus PSinit and PSbest (61 ms [56-79] vs 149 ms [134-180] and 146 ms [101-162]; p = 0.001 and 0.02, respectively). Inspiratory time in excess showed a trend to be shorter during pressure support versus neurally adjusted ventilator assist. Main asynchrony events during PSinit were autotriggering (4.8/min [1.7-12]), ineffective efforts (9.9/min [1.7-18]), and premature cycling (6.3/min [3.2-18.7]). Premature cycling (3.4/min [1.1-7.7]) was less frequent during PSbest versus PSinit (p = 0.059). The asynchrony index was significantly lower during PSbest versus PSinit (40% [28-65] vs 65.5% [42-76], p < 0.001). With neurally adjusted ventilator assist, all types of asynchronies except double triggering were reduced. The asynchrony index was lower with neurally adjusted ventilator assist (2.3% [0.7-5] vs PSinit and PSbest, p < 0.05 for both comparisons). CONCLUSION: Asynchrony events are frequent during noninvasive ventilation with pressure support in infants and in children despite adjusting the cycling-off criterion. Compared with pressure support, neurally adjusted ventilator assist allows improving patient-ventilator synchrony by reducing trigger delay and the number of asynchrony events. Further studies should determine the clinical impact of these findings.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Short-term exposure to ambient particulate matter with aerodynamic diameters<10 µm were found to be positively associated with blood pressure. Yet, little information exists regarding the association between particles and circadian rhythm of blood pressure. Hence, we analyzed the association of exposure to particulate matter with aerodynamic diameters<10 µm on the day of examination and ≤7 days before with ambulatory blood pressure and with sodium excretion in 359 adults from the general population using multiple linear regression. After controlling for potential confounders, a 10-µg/m3 increase in particulate matter with aerodynamic diameters<10 µm levels was associated with nighttime systolic blood pressure (β=1.32 mm Hg 95% CI, 0.06-2.58 mm Hg at lag 0; P=0.04), nighttime diastolic blood pressure (0.72 mm Hg 95% CI, 0.03-1.42 mm Hg at lag 2; P=0.04), nocturnal systolic blood pressure dipping (-0.96 mm Hg 95% CI, -1.89 to -0.03 mm Hg at lag 0; P=0.044), and daytime urinary sodium excretion (-0.05 log-mmol/min 95% CI, -0.10 to -0.01 log-mmol/min at lag 0; P=0.027) but not with nighttime sodium excretion. The associations with blood pressure rapidly diminished with increasing lag days, and the associations with daytime sodium excretion were maximal with particulate matter with aerodynamic diameters<10 µm in exposures 2 to 5 days before. The associations of short-term increases in particulate matter with aerodynamic diameters<10 µm with higher nighttime blood pressure and blunted systolic blood pressure dipping were preceded by associations with reduced ability of the kidney to excrete sodium during daytime. The underlying mechanism linking air pollution to increased cardiovascular risk may include disturbed circadian rhythms of renal sodium handling and blood pressure.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Kaukolämmitys on yleisin Suomessa käytetty lämmitysmuoto ja sen osuus koko lämmitysmarkkinoista on noin 50 %. Kaukolämmön varsinainen tuotanto ja jakelu alkoivat Suomessa vuonna 1957 ja Jyväskylässä vuonna 1960. Jyväskylässä kaukolämmön piiriin kuuluivuoden 2006 loppuun mennessä noin 3200 asiakasta. Suurin tuntiteho laitoksilta oli noin 375 MW. Vuonna 2020 suurimman tuntitehon on ennustettu olevan noin 480 MW, mikä tarkoittaa asiakasmäärän ja verkon pituuden merkittävää kasvua. Jyväskylän kaukolämpöverkon nykytilanne on hyvä. Verkostolaskennan tulosten perusteella lämpö saadaan siirtymään nykyisillä laitoksilla ja verkon laitteilla jokaiselle asiakkaalle niin normaalitilanteessa kuin päälaitoksen häiriötilanteessa. Häiriötilanteessa paikallisia ongelmia voi esiintyä, mutta niihin voidaan vaikuttaa parantavasti esimerkiksi verkon staattisen paineen nostolla. Jyväskylän kaukolämpöverkon tulevaisuuden näkymät ovat erinomaiset. Laskennan perusteella verkkoa voidaan laajentaa kaikille laskennassa mukana olleille alueille ilman suurempia ongelmia. Uuden tuotantokapasiteetin, verkonlaajentumisen ja asiakasmäärän kasvun aiheuttamat kehitystarpeet saatiin selvitetyksi ja tulokset olivat aikaisempien tutkimusten suuntaisia. Tulevaisuutta ajatellen verkkoon joudutaan tekemään muutamia muutoksia suunniteltujen uusien yhteyksien lisäksi. Uuteen linjaan, joka yhdistää Palokan verkon toisen yhteyden kautta Jyväskylän pääverkkoon, rakennetaan mahdollisesti pumppaamo. Lisäkuristusventtiilejä tarvitaan viiteen eri paikkaan turvaamaan riittävän suuret kaukolämpöveden paluupaineet. Osa venttiileistä olisi suositeltavaa asentaa jo nykytilanteessa, sillä niiden hankinta parantaisi verkon nykytilaa.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The antihypertensive effects of the beta-blocking agent betaxolol and the calcium entry blocker verapamil were compared in a crossover single-blind trial. Seventeen patients with uncomplicated essential hypertension took either betaxolol or a slow-release formulation of verapamil for two consecutive 6-week periods. The sequence of treatment phases was randomly allocated and a 2-week washout period preceded each treatment. The antihypertensive effect of the test drugs was assessed both at the physician's office and during everyday activities using a portable blood pressure recorder. The crossover design of the trial made it possible to evaluate the antihypertensive efficacy of betaxolol and verapamil both in the group as a whole and in the individual patient. The individual patient response to one of these agents was not a reliable indicator of the same patient's response to the alternative agent. Betaxolol brought both office and ambulatory recorded blood pressures under control in a larger fraction of patients than verapamil, although the magnitude of the blood pressure fall in the responders was equal for each drug. These observations stress the need for an individualized approach to the evaluation of antihypertensive therapy. The present results also demonstrate that optimal antihypertensive therapy is still a matter of trial and error. The precise methodology that ought to characterize crossover trials may make it possible to improve the therapeutic approach to hypertensive patients.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

High blood pressure (BP) has been ranked as the most important risk factor worldwide regarding attributable deaths. Dietary habits are major determinants of BP. Among them, frequent intake of low-fat dairy products may protect against hypertension. Our aim was to assess the relationship between low-fat dairy product intake and BP levels and their changes after 12 month follow-up in a cohort of asymptomatic older persons at high cardiovascular risk recruited into a large-scale trial assessing the effects of Mediterranean diets on cardiovascular outcomes. Data from 2290 participants, including 1845 with hypertension, were available for analyses. Dairy products were not a specific part of the intervention; thus, data were analysed as an observational cohort. Dietary information was collected with validated semi-quantitative FFQ and trained personnel measured BP. To assess BP changes, we undertook cross-sectional analyses at baseline and at the end of follow-up and longitudinal analyses. A statistically significant inverse association between low-fat dairy product intake and systolic BP was observed for the 12-month longitudinal analysis. In the longitudinal analysis, the adjusted systolic and diastolic BP were significantly lower in the highest quintile of low-fat dairy product intake ( 2 4·2 (95% CI 2 6·9, 2 1·4) and 2 1·8 (95% CI 2 3·2, 2 0·4) mmHg respectively), whereas the point estimates for the difference in diastolic BP indicated a modest non-significant inverse association. Intake of low-fat dairy products was inversely associated with BP in an older population at high cardiovascular risk, suggesting a possible protective effect against hypertension.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

High blood pressure (BP) has been ranked as the most important risk factor worldwide regarding attributable deaths. Dietary habits are major determinants of BP. Among them, frequent intake of low-fat dairy products may protect against hypertension. Our aim was to assess the relationship between low-fat dairy product intake and BP levels and their changes after 12 month follow-up in a cohort of asymptomatic older persons at high cardiovascular risk recruited into a large-scale trial assessing the effects of Mediterranean diets on cardiovascular outcomes. Data from 2290 participants, including 1845 with hypertension, were available for analyses. Dairy products were not a specific part of the intervention; thus, data were analysed as an observational cohort. Dietary information was collected with validated semi-quantitative FFQ and trained personnel measured BP. To assess BP changes, we undertook cross-sectional analyses at baseline and at the end of follow-up and longitudinal analyses. A statistically significant inverse association between low-fat dairy product intake and systolic BP was observed for the 12-month longitudinal analysis. In the longitudinal analysis, the adjusted systolic and diastolic BP were significantly lower in the highest quintile of low-fat dairy product intake ( 2 4·2 (95% CI 2 6·9, 2 1·4) and 2 1·8 (95% CI 2 3·2, 2 0·4) mmHg respectively), whereas the point estimates for the difference in diastolic BP indicated a modest non-significant inverse association. Intake of low-fat dairy products was inversely associated with BP in an older population at high cardiovascular risk, suggesting a possible protective effect against hypertension.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

High blood pressure (BP) has been ranked as the most important risk factor worldwide regarding attributable deaths. Dietary habits are major determinants of BP. Among them, frequent intake of low-fat dairy products may protect against hypertension. Our aim was to assess the relationship between low-fat dairy product intake and BP levels and their changes after 12 month follow-up in a cohort of asymptomatic older persons at high cardiovascular risk recruited into a large-scale trial assessing the effects of Mediterranean diets on cardiovascular outcomes. Data from 2290 participants, including 1845 with hypertension, were available for analyses. Dairy products were not a specific part of the intervention; thus, data were analysed as an observational cohort. Dietary information was collected with validated semi-quantitative FFQ and trained personnel measured BP. To assess BP changes, we undertook cross-sectional analyses at baseline and at the end of follow-up and longitudinal analyses. A statistically significant inverse association between low-fat dairy product intake and systolic BP was observed for the 12-month longitudinal analysis. In the longitudinal analysis, the adjusted systolic and diastolic BP were significantly lower in the highest quintile of low-fat dairy product intake ( 2 4·2 (95% CI 2 6·9, 2 1·4) and 2 1·8 (95% CI 2 3·2, 2 0·4) mmHg respectively), whereas the point estimates for the difference in diastolic BP indicated a modest non-significant inverse association. Intake of low-fat dairy products was inversely associated with BP in an older population at high cardiovascular risk, suggesting a possible protective effect against hypertension.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

High blood pressure (BP) has been ranked as the most important risk factor worldwide regarding attributable deaths. Dietary habits are major determinants of BP. Among them, frequent intake of low-fat dairy products may protect against hypertension. Our aim was to assess the relationship between low-fat dairy product intake and BP levels and their changes after 12 month follow-up in a cohort of asymptomatic older persons at high cardiovascular risk recruited into a large-scale trial assessing the effects of Mediterranean diets on cardiovascular outcomes. Data from 2290 participants, including 1845 with hypertension, were available for analyses. Dairy products were not a specific part of the intervention; thus, data were analysed as an observational cohort. Dietary information was collected with validated semi-quantitative FFQ and trained personnel measured BP. To assess BP changes, we undertook cross-sectional analyses at baseline and at the end of follow-up and longitudinal analyses. A statistically significant inverse association between low-fat dairy product intake and systolic BP was observed for the 12-month longitudinal analysis. In the longitudinal analysis, the adjusted systolic and diastolic BP were significantly lower in the highest quintile of low-fat dairy product intake ( 2 4·2 (95% CI 2 6·9, 2 1·4) and 2 1·8 (95% CI 2 3·2, 2 0·4) mmHg respectively), whereas the point estimates for the difference in diastolic BP indicated a modest non-significant inverse association. Intake of low-fat dairy products was inversely associated with BP in an older population at high cardiovascular risk, suggesting a possible protective effect against hypertension.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

High blood pressure (BP) has been ranked as the most important risk factor worldwide regarding attributable deaths. Dietary habits are major determinants of BP. Among them, frequent intake of low-fat dairy products may protect against hypertension. Our aim was to assess the relationship between low-fat dairy product intake and BP levels and their changes after 12 month follow-up in a cohort of asymptomatic older persons at high cardiovascular risk recruited into a large-scale trial assessing the effects of Mediterranean diets on cardiovascular outcomes. Data from 2290 participants, including 1845 with hypertension, were available for analyses. Dairy products were not a specific part of the intervention; thus, data were analysed as an observational cohort. Dietary information was collected with validated semi-quantitative FFQ and trained personnel measured BP. To assess BP changes, we undertook cross-sectional analyses at baseline and at the end of follow-up and longitudinal analyses. A statistically significant inverse association between low-fat dairy product intake and systolic BP was observed for the 12-month longitudinal analysis. In the longitudinal analysis, the adjusted systolic and diastolic BP were significantly lower in the highest quintile of low-fat dairy product intake ( 2 4·2 (95% CI 2 6·9, 2 1·4) and 2 1·8 (95% CI 2 3·2, 2 0·4) mmHg respectively), whereas the point estimates for the difference in diastolic BP indicated a modest non-significant inverse association. Intake of low-fat dairy products was inversely associated with BP in an older population at high cardiovascular risk, suggesting a possible protective effect against hypertension.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fiber laser for materials processing have undergone a rapid development in the pastseveral years. As fiber laser provides a combination of high beam quality and awavelength that is easily absorbed by metal surfaces, the named future laser isexpected to challenge the CO2 and Nd:YAG lasers in the area of metal cutting. This thesis studied the performance of fiber laser cutting mild steel. In the literature review part, it introduced the laser cutting principle and the principle of fiber laser including the newest development of fiber laser cuttingtechnology. Because the fiber laser cutting mild steel is a very young technology, a preliminary test was made in order to investigate effect of the cutting parameters on cut quality. Then the formal fiber laser cutting experiment was madeby using 3 mm thickness S355 steel with oxygen as assistant gas. The experimentwas focused on the cut quality with maximum cutting speed and minimum oxygen gas pressure. And the cut quality is mainly decided by the kerf width, perpendicularity tolerance, surface roughness and striation patterns. After analysis the cutting result, several conclusions were made. Although the best result got in the experiment is not perfect as predicted, the whole result of the test can be accepted. Compared with CO2 laser, a higher cutting speed was achieved by fiber laser with very low oxygen gas pressure. A further improvement about the cutting quality might be possible by proper selection of process parameters. And in order to investigate the cutting performance more clearly, a future study about cutting different thickness mild steel and different shape was recommended.