994 resultados para Posteroanterior motion test
Resumo:
A common problem in video surveys in very shallow waters is the presence of strong light fluctuations, due to sun light refraction. Refracted sunlight casts fast moving patterns, which can significantly degrade the quality of the acquired data. Motivated by the growing need to improve the quality of shallow water imagery, we propose a method to remove sunlight patterns in video sequences. The method exploits the fact that video sequences allow several observations of the same area of the sea floor, over time. It is based on computing the image difference between a given reference frame and the temporal median of a registered set of neighboring images. A key observation is that this difference will have two components with separable spectral content. One is related to the illumination field (lower spatial frequencies) and the other to the registration error (higher frequencies). The illumination field, recovered by lowpass filtering, is used to correct the reference image. In addition to removing the sunflickering patterns, an important advantage of the approach is the ability to preserve the sharpness in corrected image, even in the presence of registration inaccuracies. The effectiveness of the method is illustrated in image sets acquired under strong camera motion containing non-rigid benthic structures. The results testify the good performance and generality of the approach
Resumo:
The relief of the seafloor is an important source of data for many scientists. In this paper we present an optical system to deal with underwater 3D reconstruction. This system is formed by three cameras that take images synchronously in a constant frame rate scheme. We use the images taken by these cameras to compute dense 3D reconstructions. We use Bundle Adjustment to estimate the motion ofthe trinocular rig. Given the path followed by the system, we get a dense map of the observed scene by registering the different dense local reconstructions in a unique and bigger one
La consultation pour le test sérologique de dépistage VIH : enjeux pour le couple et pour le médecin
Resumo:
La pratique du test au centre de dépistage anonyme VIH de la Policlinique médicale universitaire de Lausanne semble indiquer que de plus en plus de personnes demandent à être testées, souvent au moment inaugural de la constitution de la vie du couple. L'indication au test de dépistage devrait être le résultat d'une négociation entre le patient et son médecin. Ce dernier est en outre confronté à la complexité des enjeux sociétaux et éthiques que le test représente. Il s'agit d'une tâche difficile, d'autant plus que la requête d'un test n'implique pas le seul devenir du sujet, mais aussi, dans la dimension sexuelle, le devenir de la personne qu'il rencontre. L'avènement du Sida a modifié la vie du couple en rendant la sexualité plus problématique et en donnant un caractère impératif l'exigence de négociation entre les partenaires du couple. La pratique de la prévention révèle aussi comment le Sida met en jeu la responsabilité que les médecins ont de négocier avec leurs patients, à l'instar de ce que ces derniers devraient faire avec leur partenaire dans un but de protection.
Resumo:
Three-dimensional imaging for the quantification of myocardial motion is a key step in the evaluation of cardiac disease. A tagged magnetic resonance imaging method that automatically tracks myocardial displacement in three dimensions is presented. Unlike other techniques, this method tracks both in-plane and through-plane motion from a single image plane without affecting the duration of image acquisition. A small z-encoding gradient is subsequently added to the refocusing lobe of the slice-selection gradient pulse in a slice following CSPAMM acquisition. An opposite polarity z-encoding gradient is added to the orthogonal tag direction. The additional z-gradients encode the instantaneous through plane position of the slice. The vertical and horizontal tags are used to resolve in-plane motion, while the added z-gradients is used to resolve through-plane motion. Postprocessing automatically decodes the acquired data and tracks the three-dimensional displacement of every material point within the image plane for each cine frame. Experiments include both a phantom and in vivo human validation. These studies demonstrate that the simultaneous extraction of both in-plane and through-plane displacements and pathlines from tagged images is achievable. This capability should open up new avenues for the automatic quantification of cardiac motion and strain for scientific and clinical purposes.
Resumo:
UBVRI photoelectric photometry is presented for 269 late spectral type, high proper motion stars belonging to the 'Lowell Proper Motion Survey' and included in the present version of the Hipparcos Input Catalogue. The observations and data reduction are described. The external errors obtained by comparison of the results with those obtained in other studies are presented.
Resumo:
PURPOSE: To determine whether motion preservation following oblique cervical corpectomy (OCC) for cervical spondylotic myelopathy (CSM) persists with serial follow-up. METHODS: We included 28 patients with preoperative and at least two serial follow-up neutral and dynamic cervical spine radiographs who underwent OCC for CSM. Patients with an ossified posterior longitudinal ligament (OPLL) were excluded. Changes in sagittal curvature, segmental and whole spine range of motion (ROM) were measured. Nathan's system graded anterior osteophyte formation. Neurological function was measured by Nurick's grade and modified Japanese Orthopedic Association (JOA) scores. RESULTS: The majority (23 patients) had a single or 2-level corpectomy. The average duration of follow-up was 45 months. The Nurick's grade and the JOA scores showed statistically significant improvements after surgery (p < 0.001). 17% of patients with preoperative lordotic spines had a loss of lordosis at last follow-up, but with no clinical worsening. 77% of the whole spine ROM and 62% of segmental ROM was preserved at last follow-up. The whole spine and segmental ROM decreased by 11.2° and 10.9°, respectively (p ≤ 0.001). Patients with a greater range of segmental movement preoperatively had a statistically greater range of movement at follow-up. The analysis of serial radiographs indicated that the range of movement of the whole spine and the range of movement at the segmental spine levels significantly reduced during the follow-up period. Nathan's grade showed increase in osteophytosis in more than two-thirds of the patients (p ≤ 0.01). The whole spine range of movement at follow-up significantly correlated with Nathan's grade. CONCLUSIONS: Although the OCC preserves segmental and whole spine ROM, serial measurements show a progressive decrease in ROM albeit without clinical worsening. The reduction in this ROM is probably related to degenerative ossification of spinal ligaments.
Resumo:
Relationships between porosity and hydraulic conductivity tend to be strongly scale- and site-dependent and are thus very difficult to establish. As a result, hydraulic conductivity distributions inferred from geophysically derived porosity models must be calibrated using some measurement of aquifer response. This type of calibration is potentially very valuable as it may allow for transport predictions within the considered hydrological unit at locations where only geophysical measurements are available, thus reducing the number of well tests required and thereby the costs of management and remediation. Here, we explore this concept through a series of numerical experiments. Considering the case of porosity characterization in saturated heterogeneous aquifers using crosshole ground-penetrating radar and borehole porosity log data, we use tracer test measurements to calibrate a relationship between porosity and hydraulic conductivity that allows the best prediction of the observed hydrological behavior. To examine the validity and effectiveness of the obtained relationship, we examine its performance at alternate locations not used in the calibration procedure. Our results indicate that this methodology allows us to obtain remarkably reliable hydrological predictions throughout the considered hydrological unit based on the geophysical data only. This was also found to be the case when significant uncertainty was considered in the underlying relationship between porosity and hydraulic conductivity.
Resumo:
test
Resumo:
A avaliação da qualidade do solo (QS) é importante estratégia no planejamento agrícola, possibilitando a identificação e o aprimoramento de sistemas de manejo com características de alta produtividade e de preservação ambiental. O presente estudo foi realizado em dois experimentos de longa duração (10 e 15 anos) conduzidos no Sul do Brasil e teve por objetivo avaliar o efeito de sistemas de manejo na QS, utilizando um kit de análise expedita de qualidade de solo (KQS), desenvolvido pelo Instituto de Qualidade do Solo-USDA-ARS. A eficiência desse kit foi avaliada pela comparação com os métodos tradicionais utilizados na ciência do solo. Nas duas áreas experimentais investigou-se um total de 12 tratamentos, os quais englobaram sistemas de preparo com diferentes intensidades de revolvimento do solo (preparo convencional, preparo reduzido e plantio direto) e sistemas de culturas com ampla faixa de adição de resíduos vegetais ao solo, além da aplicação de doses anuais de N-uréia, variando de 0 a 144 kg ha-1. Em cada base experimental uma área sob campo natural foi avaliada, servindo como referência da condição do solo na ausência de interferência antrópica. Como indicadores de QS, foram avaliados infiltração de água, respiração do solo, densidade do solo, teor de nitrato+nitrito (N-NO3- + N-NO2-), estabilidade de agregados em água e pH. De maneira geral, os coeficientes de correlação entre os métodos do KQS e os métodos tradicionais foram elevados, sendo o mais alto para o indicador pH (r = 0,98) e o menor para o indicador infiltração de água no solo (r = 0,42). Os tratamentos selecionados foram teoricamente ordenados em ordem crescente de QS, a qual foi reproduzida de forma eficiente pelo índice de estoque de carbono (IEC), calculado pela razão entre o estoque de C orgânico do solo, na camada de 0-5 cm, de cada tratamento e o estoque de C orgânico no solo sob campo natural. Os indicadores estabilidade de agregados, N-NO3- + N-NO2- e respiração do solo foram os mais eficientes em discriminar a QS. O KQS foi eficiente em avaliar a QS dos tratamentos nas duas áreas experimentais. Os níveis mais elevados de QS foram alcançados nos tratamentos com plantio direto e consórcio de gramíneas e leguminosas tropicais, devido à cobertura do solo e às elevadas adições de C e N via resíduos culturais.
Resumo:
The purpose of this study was to evaluate a free-breathing three-dimensional (3D) dual inversion-recovery (DIR) segmented k-space gradient-echo (turbo field echo [TFE]) imaging sequence at 3T for the quantification of aortic vessel wall dimensions. The effect of respiratory motion suppression on image quality was tested. Furthermore, the reproducibility of the aortic vessel wall measurements was investigated. Seven healthy subjects underwent 3D DIR TFE imaging of the aortic vessel wall with and without respiratory navigator. Subsequently, this sequence with respiratory navigator was performed twice in 10 healthy subjects to test its reproducibility. The signal-to-noise (SNR), contrast-to-noise ratio (CNR), vessel wall sharpness, and vessel wall volume (VWV) were assessed. Data were compared using the paired t-test, and the reproducibility of VWV measurements was evaluated using intraclass correlation coefficients (ICCs). SNR, CNR, and vessel wall sharpness were superior in scans performed with respiratory navigator compared to scans performed without. The ICCs concerning intraobserver, interobserver, and interscan reproducibility were excellent (0.99, 0.94, and 0.95, respectively). In conclusion, respiratory motion suppression substantially improves image quality of 3D DIR TFE imaging of the aortic vessel wall at 3T. Furthermore, this optimized technique with respiratory motion suppression enables assessment of aortic vessel wall dimensions with high reproducibility.
Resumo:
Visual perception of body motion is vital for everyday activities such as social interaction, motor learning or car driving. Tumors to the left lateral cerebellum impair visual perception of body motion. However, compensatory potential after cerebellar damage and underlying neural mechanisms remain unknown. In the present study, visual sensitivity to point-light body motion was psychophysically assessed in patient SL with dysplastic gangliocytoma (Lhermitte-Duclos disease) to the left cerebellum before and after neurosurgery, and in a group of healthy matched controls. Brain activity during processing of body motion was assessed by functional magnetic resonance imaging (MRI). Alterations in underlying cerebro-cerebellar circuitry were studied by psychophysiological interaction (PPI) analysis. Visual sensitivity to body motion in patient SL before neurosurgery was substantially lower than in controls, with significant improvement after neurosurgery. Functional MRI in patient SL revealed a similar pattern of cerebellar activation during biological motion processing as in healthy participants, but located more medially, in the left cerebellar lobules III and IX. As in normalcy, PPI analysis showed cerebellar communication with a region in the superior temporal sulcus, but located more anteriorly. The findings demonstrate a potential for recovery of visual body motion processing after cerebellar damage, likely mediated by topographic shifts within the corresponding cerebro-cerebellar circuitry induced by cerebellar reorganization. The outcome is of importance for further understanding of cerebellar plasticity and neural circuits underpinning visual social cognition.