970 resultados para Portal Vein


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Increased understanding of the hyperdynamic circulation syndrome has resulted in novel therapeutic approaches, some of which have already reached clinical practice. Central to the hyperdynamic circulation syndrome is an imbalance between the increase in different vasodilators (foremost among which is nitric oxide) and the compensatory increase in vasoconstrictors--usually accompanied by a blunted response. This chapter discusses the role of endothelin in the pathogenesis of the syndrome and in future treatment approaches. A relatively new area of research in this field is the role of infection and inflammation in the initiation and maintenance of the hyperdynamic circulation syndrome. The use of antibiotics in the setting of acute variceal bleeding is standard practice. Studies have suggested that chronic manipulation of the intestinal flora could have beneficial effects in the treatment of portal hypertension. The bile salts are another novel and interesting target. Although their vasoactive properties have been known for some time, recent data demonstrate that their effects could be central in the pathogenesis of the hyperdynamic circulation syndrome, and that manipulation of the composition of the bile acid pool could be a therapeutic approach to portal hypertension. Finally, hypoxia and angiogenesis play a role in the development of portal hypertension and the formation of collaterals. This role needs to be further defined but it appears likely that this phenomenon is yet another target for therapeutic intervention.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We present a case of combined central retinal vein and cilioretinal artery occlusion which, due to the absence of the temporal branch retinal artery, was initially misdiagnosed as a combined central retinal vein occlusion and temporal branch retinal artery occlusion. Given that - in contrast to cases of combined central artery and central retinal vein occlusion - the prognosis for cilioretinal artery occlusion with central retinal vein occlusion is quite good, this case illustrates the importance of suspecting an unusual condition in the presence of a combined occlusion.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVES: To evaluate the efficacy of stent placement after infrainguinal loco-regional thrombolysis and iliac thrombectomy (surgical TT) of acute deep vein thrombosis (DVT) in patients with May-Thurner-Syndrome. MATERIAL AND METHODS: We retrospectively analysed a group of 11 patients (9 women) (mean age 34 years, range 16-64 years) with surgical TT and additional intra-operative stenting due to compression of the common iliac vein. Patients underwent venography to demonstrate outflow patency after surgical TT, and to identify any obstruction at the level of the left-sided common iliac vein ("Beckenvenen-Sporn"). Obstruction at the level of arterial crossing was treated using Wallstents placed via an introducer sheath from the inguinal access site. Stents were fully deployed using balloons adjusted to the size of vein. Patients were treated with oral anticoagulants for 6 months, and followed using duplex ultrasonography. RESULTS: Technical success defined as complete vein patency and normal valve function was documented in all 11 patients. One patient needed early stent extension due to residual stenosis. At 6 months follow-up one patient (9%) had an asymptomatic occlusion of the stented common iliac vein. In all 11/11 (100%) patients the femoral segment was found to be patent, and in 1/11 (9%) there was mild reflux with few clinical symptoms of post-thrombotic syndrome. The calculated cumulative primary patency rate for venous iliac stents was 82%, and assisted patency rate was 91%, which remained unchanged over a mean follow-up of 22 months. CONCLUSION: Combining surgical TT and stenting of common iliac vein obstructions in DVT is safe, effective, and results in a acceptable venous patency.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: This study aimed to evaluate the safety and patency rate of bovine mesenterial vein grafts (BMVG) for vascular access (VA) in hemodialysis patients (HDP), compared to expanded polytetrafluorethylene (ePTFE grafts) over a mid- to long-term period. METHODS: Patency and complication rate of 23 consecutive HDP with BMVG for VA were compared to a control group consisting of 23 similar HDP with ePTFE grafts. In both groups, the graft was placed preferably in a forearm loop configuration. The same surgeon performed all procedures. All patients were followed over a period of 4 yrs. RESULTS: Graft placement was successful in all patients. Patency rates did not differ significantly in both groups. However, there were less severe complications in the BMVG group. CONCLUSION: The BMVG is a viable alternative for HD access in patients where autologous construction is not possible, and should be given priority in patients with a failed ePTFE graft or high risk for infection.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Cryopreserved human blood vessels are important tools in reconstructive surgery. However, patency of frozen/thawed conduits depends largely on the freezing/thawing procedures employed. METHODS: Changes in tone were recorded on rings from human saphenous vein (SV) and used to quantify the degree of cryoinjury after different periods of exposure at room temperature to the cryomedium (Krebs-Henseleit solution containing 1.8M dimethyl sulfoxide and 0.1M sucrose) and after different cooling speeds and thawing rates following storage at -196 degrees C. RESULTS: Without freezing, exposure of SV to the cryomedium for up to 240 min did not modify contractile responses to noradrenaline (NA). Pre-freezing exposure to the cryomedium for 10-120 min attenuated significantly post-thaw maximal contractile responses to NA, endothelin-1 (ET-1) and potassium chloride (KCl) by 30-44%. Exposure for 240 min attenuated post-thaw contractile responses to all tested agents markedly by 62-67%. Optimal post-thaw contractile activity was obtained with SV frozen at about -1.2 degrees C/min and thawed slowly at about 15 degrees C/min. In these SV maximal contractile responses to NA, ET-1 and KCl amounted to 66%, 70% and 60% of that produced by unfrozen controls. Following cryostorage of veins for up to 10 years the responsiveness of vascular smooth muscle to NA was well maintained. CONCLUSION: Cryopreservation allows long-term banking of viable human SV with only minor loss in contractility.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The verification possibilities of dynamically collimated treatment beams with a scanning liquid ionization chamber electronic portal image device (SLIC-EPID) are investigated. The ion concentration in the liquid of a SLIC-EPID and therefore the read-out signal is determined by two parameters of a differential equation describing the creation and recombination of the ions. Due to the form of this equation, the portal image detector describes a nonlinear dynamic system with memory. In this work, the parameters of the differential equation were experimentally determined for the particular chamber in use and for an incident open 6 MV photon beam. The mathematical description of the ion concentration was then used to predict portal images of intensity-modulated photon beams produced by a dynamic delivery technique, the sliding window approach. Due to the nature of the differential equation, a mathematical condition for 'reliable leaf motion verification' in the sliding window technique can be formulated. It is shown that the time constants for both formation and decay of the equilibrium concentration in the chamber is in the order of seconds. In order to guarantee reliable leaf motion verification, these time constants impose a constraint on the rapidity of the image-read out for a given maximum leaf speed. For a leaf speed of 2 cm s(-1), a minimum image acquisition frequency of about 2 Hz is required. Current SLIC-EPID systems are usually too slow since they need about a second to acquire a portal image. However, if the condition is fulfilled, the memory property of the system can be used to reconstruct the leaf motion. It is shown that a simple edge detecting algorithm can be employed to determine the leaf positions. The method is also very robust against image noise.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Today electronic portal imaging devices (EPID's) are used primarily to verify patient positioning. They have, however, also the potential as 2D-dosimeters and could be used as such for transit dosimetry or dose reconstruction. It has been proven that such devices, especially liquid filled ionization chambers, have a stable dose response relationship which can be described in terms of the physical properties of the EPID and the pulsed linac radiation. For absolute dosimetry however, an accurate method of calibration to an absolute dose is needed. In this work, we concentrate on calibration against dose in a homogeneous water phantom. Using a Monte Carlo model of the detector we calculated dose spread kernels in units of absolute dose per incident energy fluence and compared them to calculated dose spread kernels in water at different depths. The energy of the incident pencil beams varied between 0.5 and 18 MeV. At the depth of dose maximum in water for a 6 MV beam (1.5 cm) and for a 18 MV beam (3.0 cm) we observed large absolute differences between water and detector dose above an incident energy of 4 MeV but only small relative differences in the most frequent energy range of the beam energy spectra. It is shown that for a 6 MV beam the absolute reference dose measured at 1.5 cm water depth differs from the absolute detector dose by 3.8%. At depth 1.2 cm in water, however, the relative dose differences are almost constant between 2 and 6 MeV. The effects of changes in the energy spectrum of the beam on the dose responses in water and in the detector are also investigated. We show that differences larger than 2% can occur for different beam qualities of the incident photon beam behind water slabs of different thicknesses. It is therefore concluded that for high-precision dosimetry such effects have to be taken into account. Nevertheless, the precise information about the dose response of the detector provided in this Monte Carlo study forms the basis of extracting directly the basic radiometric quantities photon fluence and photon energy fluence from the detector's signal using a deconvolution algorithm. The results are therefore promising for future application in absolute transit dosimetry and absolute dose reconstruction.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: The objective of this study was to investigate the feasibility, outcomes, and amount of small intestinal submucosa (SIS) material needed for embolization of jugular vein (JV) in a swine and sheep model. Our hypothesis was that SIS would cause vein occlusion. MATERIALS AND METHODS: The external JVs (EJV) in swine (n = 6) and JVs in sheep (n = 6) were occluded with SIS fan-folded compressed strips. After percutaneous puncture of the peripheral portion of the EJV or JV, a TIPS set was used to exit their lumen centrally through the skin. The SIS strips were delivered into the isolated venous segment with a pull-through technique via a 10-Fr sheath. Follow-up venograms were done immediately after placement and at the time of sacrifice at 1 or 3 months. Gross examinations focused on the EJV or JV and their surrounding structures. Specimens were evaluated by histology. RESULTS: SIS strip(s) placement was successful in all cases, with immediate vein occlusion seen in 23 of 24 veins (95.8%). All EJVs treated with two strips and all JVs treated with three or four strips remained closed on 1- and 3-month follow-up venograms. Two EJVs treated with one strip and one JV treated with two strips were partially patent on venograms at 1 and 3 months. There has been one skin inflammatory reaction. Necropsies revealed excluded EJV or JV segments with SIS incorporation into the vein wall. Histology demonstrated various stages of SIS remodeling with fibrocytes, fibroblasts, endothelial cells, capillaries, and inflammatory cells. CONCLUSION: We conclude that EJV and JV ablation with SIS strips using percutaneous exit catheterization is feasible and effective in animal models. Further exploration of SIS as vein ablation material is recommended.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In most Asian subjects with postural proteinuria, ultrasonic imaging and Doppler flow scanning disclose entrapment of the left renal vein in the fork between the aorta and the superior mesenteric artery. Little information is available on the possible occurrence of left venal rein entrapment in European subjects with postural proteinuria. Renal ultrasound with Doppler flow imaging was therefore performed on 24 Italian or Swiss patients with postural proteinuria (14 girls and ten boys, aged between 5.2 years and 16 years). Signs of aorto-mesenteric left renal vein entrapment were noted in 18 of the 24 subjects. In conclusion, aorto-mesenteric left renal vein entrapment is common also among European subjects with postural proteinuria.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The GLAaS algorithm for pretreatment intensity modulation radiation therapy absolute dose verification based on the use of amorphous silicon detectors, as described in Nicolini et al. [G. Nicolini, A. Fogliata, E. Vanetti, A. Clivio, and L. Cozzi, Med. Phys. 33, 2839-2851 (2006)], was tested under a variety of experimental conditions to investigate its robustness, the possibility of using it in different clinics and its performance. GLAaS was therefore tested on a low-energy Varian Clinac (6 MV) equipped with an amorphous silicon Portal Vision PV-aS500 with electronic readout IAS2 and on a high-energy Clinac (6 and 15 MV) equipped with a PV-aS1000 and IAS3 electronics. Tests were performed for three calibration conditions: A: adding buildup on the top of the cassette such that SDD-SSD = d(max) and comparing measurements with corresponding doses computed at d(max), B: without adding any buildup on the top of the cassette and considering only the intrinsic water-equivalent thickness of the electronic portal imaging devices device (0.8 cm), and C: without adding any buildup on the top of the cassette but comparing measurements against doses computed at d(max). This procedure is similar to that usually applied when in vivo dosimetry is performed with solid state diodes without sufficient buildup material. Quantitatively, the gamma index (gamma), as described by Low et al. [D. A. Low, W. B. Harms, S. Mutic, and J. A. Purdy, Med. Phys. 25, 656-660 (1998)], was assessed. The gamma index was computed for a distance to agreement (DTA) of 3 mm. The dose difference deltaD was considered as 2%, 3%, and 4%. As a measure of the quality of results, the fraction of field area with gamma larger than 1 (%FA) was scored. Results over a set of 50 test samples (including fields from head and neck, breast, prostate, anal canal, and brain cases) and from the long-term routine usage, demonstrated the robustness and stability of GLAaS. In general, the mean values of %FA remain below 3% for deltaD equal or larger than 3%, while they are slightly larger for deltaD = 2% with %FA in the range from 3% to 8%. Since its introduction in routine practice, 1453 fields have been verified with GLAaS at the authors' institute (6 MV beam). Using a DTA of 3 mm and a deltaD of 4% the authors obtained %FA = 0.9 +/- 1.1 for the entire data set while, stratifying according to the dose calculation algorithm, they observed: %FA = 0.7 +/- 0.9 for fields computed with the analytical anisotropic algorithm and %FA = 2.4 +/- 1.3 for pencil-beam based fields with a statistically significant difference between the two groups. If data are stratified according to field splitting, they observed %FA = 0.8 +/- 1.0 for split fields and 1.0 +/- 1.2 for nonsplit fields without any significant difference.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A levoatrial cardinal vein is a rare cardiovascular anomaly that may be present in malformed hearts with severe left heart obstruction and restrictive interatrial communication. We report the prenatal diagnosis at 23 weeks of a fetus with mitral atresia, double-outlet right ventricle, premature closure of the foramen ovale and a levoatrial cardinal vein draining into the innominate vein. In a prior examination performed elsewhere the levoatrial cardinal vein had been interpreted as an aortic arch perfused retrogradely, and hypoplastic left heart syndrome with aortic atresia had been diagnosed. Prenatal management, induction at 38 weeks and postnatal examinations and treatment are reported. To the best of our knowledge, this is the first reported prenatal diagnosis of this embryological vessel, presenting a potential pitfall for prenatal echocardiography.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Branch retinal vein occlusion is a frequent cause of visual loss with currently insufficient treatment options. We evaluate the effect of Bevacizumab (Avastin) treatment in patients with macular edema induced by branch retinal vein occlusion.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND/AIMS: The integrin alphavbeta6 promotes proliferation of specialized epithelia and acts as a receptor for the activation of latent TGFbeta1. We studied alphavbeta6 expression in experimental and human liver fibrosis and the potential of its pharmacological inhibition for treatment of hepatic fibrosis. METHODS: alphavbeta6 expression was studied by quantitative PCR and immunohistochemistry in rats with cirrhosis due to bile duct ligation (BDL), administration of thioacetamide (TAA), in Mdr2(Abcb4)(-/-) mice with spontaneous biliary fibrosis, and in livers of patients with chronic hepatitis C (n=79) and end-stage liver disease due to various etiologies (n=18). The effect of a selective alphavbeta6 inhibitor was evaluated in Mdr2(Abcb4)(-/-) mice with ongoing fibrogenesis. RESULTS: Integrin beta6 mRNA increased with fibrosis stage in hepatitis C and was upregulated between 25- and 100-fold in TAA- and BDL-induced cirrhosis, in Mdr2(Abcb4)(-/-) mice and in human end-stage liver disease. alphavbeta6 protein was absent in normal livers and expressed de novo on (activated) bile duct epithelia and transitional hepatocytes. A single dose of the alphavbeta6 inhibitor injected into Mdr2(Abcb4)(-/-) mice significantly induced profibrolytic matrix metalloproteinases (MMP)-8 and -9 after 3 h, with a corresponding increase in extracellular matrix-degrading activities. In parallel profibrogenic transcripts (procollagen alpha1(I), TGFbeta2, and MMP-2) showed a trend of downregulation. CONCLUSIONS: (1) Integrin alphavbeta6 is induced de novo in rodent and human liver fibrosis, where it is expressed on activated bile duct epithelia and (transitional) hepatocytes during fibrosis progression. (2) In vivo a single dose of a small molecule alphavbeta6 inhibitor induced antifibrogenic and profibrolytic genes and activities, suggesting alphavbeta6 is a unique target for treatment of liver fibrosis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: The purpose of this study was to delineate the anatomy of the precentral cerebellar vein, superior vermian vein, and internal occipital vein using reconstructions of computed tomographic and magnetic resonance imaging scans with navigation software. These data were compared with previous anatomic and angiographic findings to show the resolution and accuracy of the system. METHODS: We retrospectively reviewed 100 patients with intracranial pathologies (50 computed tomographic scans with contrast and 50 magnetic resonance imaging scans with gadolinium) using a neuronavigation workstation for 3-dimensional reconstruction. Particular attention was paid to depiction of the precentral cerebellar vein, superior vermian vein, and internal occipital vein. The data were reviewed and analyzed. RESULTS: The precentral cerebellar vein, superior vermian vein, and its tributary, the supraculminate vein, were depicted in 52 (52%) patients. The internal occipital vein was delineated on 99 (49.5%) sides and joined the basal vein and vein of Galen in 39 (39.4%) and 60 (60.6%) hemispheres, respectively. Comparing these results with previous angiographic studies, the ability of the neuronavigation system for depicting these vessels is similar to that of digital subtraction angiography. CONCLUSION: This study illustrates the possibility of depicting the small vessels draining into the pineal region venous complex using 3-dimensional neuronavigation with an accuracy comparable to that of digital subtraction angiography. This tool provides important information for both surgical planning and intraoperative orientation.