926 resultados para Paraffin embedded tissues


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The study compared the host response to a human and a porcine acellular dermal tissue implanted in the subcutaneous space of a rat model. The human and porcine acellular grafts were surgically implanted in the subcutaneous tissue of rats (5 rats/group) and the materials were evaluated at 7, 15, 30, 60 and 180 postoperative days (PO). The histological immune response was quantified using a digital image analysis system, which evaluated the number of vessels present in the implants and in the surrounding soft tissue, the area of inflammatory cell infiltration in the grafts, the width of the capsular formation present around the tissues and the area of implants absorbed. The data were submitted to statistical analysis. Light microscopy showed mononuclear cellular infiltration, the presence of a capsular formation surrounding the grafts and the presence of vacuolar structures (optically empty spaces) inside the implants. The image analysis comparing both materials showed significant inflammatory cells in the human graft at 15 and 30 PO, thicker capsular formation in the porcine tissue at 60 PO, increased number of vessels inside the implants and in the surrounding tissues in the porcine graft and a similar absorption pattern in both materials at 180 PO. The histological findings showed that both tissues were well-tolerated when implanted in the subcutaneous tissue of rats, allowing us to consider the porcine acellular dermal graft as a provisional alternative material for reconstructive plastic surgery. Copyright © 2005 Taylor & Francis LLC.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Since the 1980s, huge efforts have been made to utilise renewable energy sources to generate electric power. One of the interesting issues about embedded generators is the question of optimal placement and sizing of the embedded generators. This paper reports an investigation of impact of the integration of embedded generators on the overall performances of the distribution networks in the steady state, using theorem of superposition. Set of distribution system indices is proposed to observe performances of the distribution networks with embedded generators. Results obtained from the case study using IEEE test network are presented and discussed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A histological study was conducted of the alveolar bone healing process following tooth extraction of dehydrated rats after the implantation of fibrin adhesive (TISSUCOL™) associated to previous irrigation of the wound with a 5% epsilon aminocaproic acid solution (EACA). Seventy two rats were used, divided into three groups receiving different treatments after the surgical procedure. In group I, the gingival mucosa was sutured after extraction of the right upper incisor. In groups II and III, chronic dehydration was produced by water deprivation for 9 days (3 days in the preoperative period and 6 days in the postoperative period). In the animals of Group II, after tooth extraction, the gingival mucosa was sutured in the same way as performed in group I. In group III, after extraction, the dental socket was irrigated with 5% EACA, followed by implantation of the fibrin adhesive (TISSUCOL™). The mucosa was sutured in the same way as performed in the other groups. At 3, 7, 15 and 21 postoperative days, the animals were sacrificed in number of 6 for each group. Specimens containing the dental socket were removed and fixed in 10% formalin and decalcified in an equal part formic acid and sodium citrate solution. After routine processing, the specimens were embedded in paraffin for microtomy. We obtained 6 μm semi-serial slices that were stained with hematoxylin and eosin for histological evaluation. The results showed that the water deprivation in the pre- and postoperative periods caused a delay in the alveolar bone healing process. The use of the fibrin adhesive (TISSUCOL™) produced an improvement in the fibrinolytic picture caused by dehydration.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In the present study, we evaluated three techniques, mouse bioassay, histopathology, and polymerase chain reaction (PCR) to detect Toxoplasma gondii infection in tissues from experimentally infected pigs. Twelve mixed breed pigs, seronegative for T. gondii using an indirect immunofluorescent antibody test (IFAT), were used. Ten pigs were infected with 4 × 104 VEG strain oocysts, and two were maintained as uninfected controls. Animals were killed 60 days pos infection. Muscle (heart, tongue, diaphragm, and masseter) and brain samples were collected to investigate the presence of T. gondii tissue cysts by the different assay methods. For the bioassay, samples of brain (50 g) and pool of muscle samples (12.5 g of tongue, masseter, diaphragm, and heart) were used. PCR was performed using Tox4 and Tox5 primers which amplified a 529 bp fragment. The DNA extraction and PCR were performed three times, and all tissue samples were tested individually (brain, tongue, masseter, diaphragm, and heart). For histopathology, fragments of tissues were fixed in 10% of buffered formal saline and stained with HE. Histopathological results were all negative. PCR showed 25/150 (16.6%) positive samples, being 17/120 (14.1%) and 8/30 (26.6%) from muscle, and brain tissues, respectively. Tissue cysts of T. gondii were identified by mouse bioassay in 54/98 (55.1%) samples, being 31/48 (64.6%) from muscle samples, and 23/50 (46.0%) from brain samples. Toxoplasma gondii isolation in muscle samples by mouse bioassay was higher than in PCR (P < 0.01). Results indicate that DNA from pig tissues interfered with 529-bp-PCR sensitivity, and mouse bioassay was better than PCR in detecting T. gondii in tissues from pigs. © 2006 Elsevier Inc. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study was to show the microwaves action in fixation of rat fetuses, dermal and cartilaginous tissues, using histological and immunohistochemistry methods for analysis. It was possible to conclude in this study using the rat as experimental model that the two methods for antibody retrieval, presented an excellent ways for the use of Ki67 antibody in the immunohistochemical analysis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Tacrolimus, an immunosuppressive drug used in organ transplantation, has been reported not to induce gingival overgrowth. However, prevalence studies are limited, and the methods used for assessing gingival overgrowth varies among studies. Objective: The purpose of this study was to evaluate the effects of up to 240 days of tacrolimus therapy on gingival tissues of rats. Materials and methods: Rats were treated for 60, 120, 180 and 240 days with daily subcutaneous injections of 1 mg/kg body weight of tacrolimus. After histological processing, the oral and connective tissue, volume densities of fibroblasts (Vf), collagen fibers (Vcf) and other structures (Vo) were assessed in the region of the lower first molar. Results: After 60 and 120 days of treatment with tacrolimus, gingival overgrowth was not observed. The gingival epithelium, connective tissue, as well as the values for Vf, Vcf, and Vo were similar to those of the control rats (P > 0.05). After 180 and 240 days of the treatment, gingival overgrowth was associated with a significant increase in the gingival epithelium and connective tissue as well as an increase in the V f and Vcf (P < 0.05). Conclusions: Within the limits of the experimental study, it may be concluded that the deleterious side effects of tacrolimus on the gingival tissues of rats may be time-related. © 2007 Blackwell Munksgaard All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Bioceramics with different Ca/P ratio were prepared from a mechanical mixture of NaPO3, CaCO3, Ca(OH)2 and phosphate buffer solution and implanted in rats subcutaneous tissues. The cements were characterized by Thermo gravimetric analysis (TG-TDA), X-ray diffraction and 31P-NMR. The implant sites were excised after 1, 4 and 16 weeks, fixed, dehydrated, included in paraffin wax for serial cutting and examined under the light transmitted microscope. They were biocompatible and biodegradable when implanted in rat subcutaneous. None of the materials induced ectopic osteogenesis. According to the results, the studied materials seem to be able for manufacturing reabsorbable bone implants.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The biological response following subcutaneous and bone implantation of β-wollastonite(β-W)-doped α-tricalcium phosphate bioceramics in rats was evaluated. Tested materials were: tricalcium phosphate (TCP), consisting of a mixture of α- and β-polymorphs; TCP doped with 5 wt. % of β-W (TCP5W), composed of α-TCP as only crystalline phase; and TCP doped with 15 wt. % of β-W (TCP 15), containing crystalline α-TCP and β-W. Cylinders of 2×1 mm were implanted in tibiae and backs of adult male Rattus norvegicus, Holtzman rats. After 7, 30 and 120 days, animals were sacrificed and the tissue blocks containing the implants were excised, fixed and processed for histological examination. TCP, TCP5W and TCP15W implants were biocompatible but neither bioactive nor biodegradable in rat subcutaneous tissue. They were not osteoinductive in connective tissue either. However, in rat bone tissue β-W-doped α-TCP implants (TCP5W and TCP 15W) were bioactive, biodegradable and osteoconductive. The rates of biodegradation and new bone formation observed for TCP5W and TCP15W implants in rat bone tissue were greater than for non-doped TCP.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A digital-desk pilot program, named One Laptop Per Child (OPLC), in Brazil uses a unique display design to provide an interactive interface developed to enhance education and minimize ergonomic concerns. The one-to-one computer strategy as proposed by Nicholas Negroponte is a way of circumventing the tragedy of the locked computer lab because it gives children full access to computers anytime. The OLPC program has focused on a solution that minimizes power consumption, which also limits the display's maximum size and processor performance because the LCD backlights are responsible for a significant part of the power consumption in laptops. The government has also developed a new type of low-cost tablet that is based on a resistive principle. High transparencies can be obtained in the 90% range in the tablet, while robustness is guaranteed by the outstanding tribological characteristics of Sn02 on glass.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This experimental light microscopy study investigated the formation of a hybrid layer and resin tags on sound dentin, after utilization of conventional and self-etching adhesive systems. After restorative procedures, the specimens were decalcified in a formic acid and sodium citrate solution, embedded in paraffin, sectioned at 6-microm thickness and stained by the Brown & Brenn method for analysis and measurement by light microscopy (AXIOPHOT) (400x). The results were statistically analyzed by analysis of variance, at a significance level of 5%. Based on the results, it could be concluded that the conventional adhesive allowed the formation of a thicker hybrid layer than the self-etching adhesive, with similar penetration into the dentinal tubules (resin tags).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents a NCAP embedded on DE2 kit with Nios II processor and uClinux to development of a network gateway with two interfaces, wireless (ZigBee) and wired (RS232) based on IEEE 1451. Both the communications, wireless and wired, were developed to be point-to-point and working with the same protocols, based on IEEE 1451.0-2007. The tests were made using a microcomputer, which through of browser was possible access the web page stored in the DE2 kit and send commands of control and monitoring to both TIMs (WTIM and STIM). The system describes a different form of development of the NCAP node to be applied in different environments with wired or wireless in the same node. © 2011 IEEE.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In the paper the improvement of a traditional structure of a microprogrammed controller with sharing codes is discussed. The idea is based on the modification of internal modules and connections of the device. Such a solution permits to reduce the number of embedded memories needed for implementation of the microprogrammed controller on programmable structures, especially FPGAs. © 2011 IEEE.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents a network node embedded based on IEEE 1451 standard developed using structured programming to access the transducers in the WTIM. The NCAP was developed using Nios II processor and uClinux, a embedded operating system developed to features restricted hardware. Both hardware and software have dynamics features and they can be configured based in the application features. Based in this features, the NCAP was developed using the minimum components of hardware and software to that being implemented in remote environment like central point of data request. Many NCAP works are implemented with an object oriented structure. This is different from the surrounding implementations. In this project the NCAP was developed using structured programming. The tests of the NCAP were made using a ZigBee interface between NCAP and WTIM and the system demonstrated in areas of difficult access for long period of time due to need for low power consumption. © 2012 IEEE.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Cimetidine, an H2 receptor antagonist used for treatment of gastric ulcers, exerts antiandrogenic and antiangiogenic effects. In the testes cimetidine impairs spermatogenesis, Sertoli cells and peritubular tissue, inducing apoptosis in the myoid cells. Regarding the importance of histamine and androgens for vascular maintenance, the effect of cimetidine on the structural integrity of the testicular vasculature was evaluated. Adult male rats received cimetidine (CMTG) and saline (CG) for 50 days. The testes were fixed in buffered 4% formaldehyde and embedded in historesin and paraffin. In the PAS-stained sections, the microvascular density (MVD) and the vascular luminal area (VLA) were obtained. TUNEL method was performed for detection of cell death. Testicular fragments embedded in Araldite were analyzed under transmission electron microscopy. A significant decrease in the MVD and VLA and a high number of collapsed blood vessel profiles were observed in CMTG. Endothelial cells and vascular muscle cells were TUNEL-positive and showed ultrastructural features of apoptosis. These results indicate that cimetidine induces apoptosis in vascular cells, leading to testicular vascular atrophy. A possible antagonist effect of cimetidine on the H2 receptors and/or androgen receptors in the vascular cells may be responsible for the impairment of the testicular microvasculature.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The real-time monitoring of events in an industrial plant is vital, to monitor the actual conditions of operation of the machinery responsible for the manufacturing process. A predictive maintenance program includes condition monitoring of the rotating machinery, to anticipate possible conditions of failure. To increase the operational reliability it is thus necessary an efficient tool to analyze and monitor the equipments, in real-time, and enabling the detection of e.g. incipient faults in bearings. To fulfill these requirements some innovations have become frequent, namely the inclusion of vibration sensors or stator current sensors. These innovations enable the development of new design methodologies that take into account the ease of future modifications, upgrades, and replacement of the monitored machine, as well as expansion of the monitoring system. This paper presents the development, implementation and testing of an instrument for vibration monitoring, as a possible solution to embed in industrial environment. The digital control system is based on an FPGA, and its configuration with an open hardware design tool is described. Special focus is given to the area of fault detection in rolling bearings. © 2012 IEEE.