890 resultados para PINCH TECHNIQUE


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this work, differential scanning calorimetry (DSC) was used to study the mechanism of crystallization of 5OP(2)O(5-)27.8Na(2)O-16ZnO-6.2Al(2)O(3) glass. DSC measurements were performed on bulk and powdered glasses with different particle size. The curve for bulk glass shows one crystallization peak while powdered glasses presented two distinct crystallization peaks. Based on DSC studies, the activation energies obtained were 336 +/- 6 and 213 +/- 3 U mol(-1), associated with first and second crystallization peaks, respectively. Analyzing the DSC parameters as a function of particle size, the Avrami n parameter suggests that the peak at low temperature may be associated with surface crystallization while the peak at high temperature is associated with bulk crystallization. (C) 2002 Elsevier B.V. Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction: So far the only endovascular option to treat patients with thoraco abdominal aortic aneurysms is the deployment of branched grafts. We describe a technique consisting of the deployment of standard off-the- shelf grafts to treat urgent cases.Material and Methods: The sandwich technique consists of the deployment of ViaBahn chimney grafts in combination with standard thoracic and abdominal aortic stent grafts. The chimney grafts are deployed using a transbrachial and transaxillary access. These coaxial grafts are placed inside the thoracic tube graft. After deployment of the infrarenal bifurcated abdominal graft a bridging stent-a short tube graft is positioned inside the thoracic graft further stabilizing the chimney grafts.Results: 5 patients with symptomatic thoraco abdominal aneurysms were treated. There was one Type I endoleak that resolved after 2 months. In all patients 3 stentgrafts had to be used When possible all visceral and renal branches were revascularized. A total number of 17 arteries were reconnected with covered branches. During follow up we lost one target vessel the right renal artery.Conclusion: The sandwich technique in combination with chimney grafts permits a total endovascular exclusion of thoraco abdominal aortic aneurysms. In all cases off-the shelf products and grafts could be used. The number of patients treated so far is still too small to draw further more robust conclusions with regard to long term performance and durability. (C) 2010 European Society for Vascular Surgery. Published by Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Isolated iliac artery aneurysms are rare in the general population (0.03%) and represent 2% of all abdominal aneurysms, and the association with Marfan syndrome is even rarer. We report a Marfan syndrome case with an isolated common iliac artery aneurysm treated by using a modified 'stent-graft sandwich' technique, with preservation of the internal iliac artery perfusion. The modified 'stent-graft sandwich' technique involves building an appropriate proximal neck just in the common iliac artery for fittingly housing two new stent-grafts inside, both deployed simultaneously and each one going to both distal iliac arteries (internal and external).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Limitations of endovascular thoracic aneurym treatment include small, tortuous, or severely calcified iliac Back, arteries. We present our experience with a total laparoscopic access to deploy thoracic endografts.Methods. A total laparoscopic left retrocolic approach was used in all cases. A Dacron conduit was laparoscopically sutured to either the iliac artery or to the aorta directly. The endograft was inserted through this conduit. After graft deployment, the Dacron prosthesis was tunneled to the groin and anastomosed with the femoral artery.Results. The laparoscopic procedure could successfully be performed in 11 patients. In six cases, the aorta was used as all access and in five patients, the iliac arteries were preferred. In one of these cases, the right iliac artery, was used for deployment of the endograft. After successful aorto- or ileo-femoral bypass grafting, all patients had an improvement of their ankle brachial index postoperatively. The mean operative time was almost four hours, including laparoscopy, laparoscopic anastomosis, endograft deployment, and femoral artery anastomosis or profundaplasty.Conclusion: Totally laparoscopic assisted graft implantation in aorta or iliac arteries provides a safe and effective access for the endovascular delivery system. However, further evaluation and long follow-up are necessary to ensure the potential advantages of this technique. It is a less invasive option to overcome access-related problems with thoracic endograft deployment, giving the patient the advantage of a totally minimal invasive procedure. (J Vasc Surg 2010;51:504-8.)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An approximately 9-month-old fox (Pseudalopex ventulus) was presented With malocclusion and deviation of the lower jaw to the right side. Orthodontic treatment was performed using the inclined plane technique. Virtual 3D models and prototypes of the head were based on computed tomography (CT) image data to assist in diagnosis and treatment.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The tissue microarray (TMA) technique allows multiple tissue samples in a single block. Commercial adhesive tape is used to avoid the loss of tissue samples during the immunostaining process. Few reports exist in the literature comparing the use of these adhesive tapes to other adhesive techniques. The objective of this study was to compare loss of sections adhered to slides using commercial adhesive tapes versus using silanized only slides. TMA was constructed with varying tissues using a fixed-base device (Beecher Instruments), placing 108 cylinders of 1 mm diameter in duplicate, spaced 1.2 mm apart. Section of 4 mu m were cut from the TMA block and adhered to 30 silanized slides and 30 commercial glass slides using adhesive tape, according to manufacturer's recommendations. Vimentin immunoexpression was evaluated by immunohistochemistry. Antigenic recovery was realized in citrate buffer using a microwave oven. Cylinder loss in the immunohistochemical process was quantified and expressed as: total (>80%), almost complete (75-79%), or partial (50-74%). The commercial adhesive tape group presented lesser total loss (1.1 versus 6.4%), almost complete loss (2.2 versus 3.5%), and partial loss (2.1 versus 3.8%) than the silanized slide group (ANOVA, P < 0.05). The sum of total and almost complete losses in the silanized slide group was 9.9%, greater than the losses in slides using commercial adhesive tapes (3.3%) and less than reported and considered acceptable in the literature (10-30%). In conclusion, the use of silanized only slides presents very satisfactory results, requires less training, and reduces costs significantly, thus justifying their use in research.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An 8-year-old male Boxer with a severely contaminated open fracture of the left radius and ulna fracture, produced by a helicopter propeller, was treated using bone transport by the Ilizarov method. Extensive diaphyseal bone loss and soft-tissue vascular damage were present. The radius and ulna were stabilised with an Ilizarov ring external fixator. The bone defect was partially shortened and restored by gradual transport of a bone segment created from proximal segments of the radius and ulna. The external fixator was removed 4fi months after the beginning of the latency period, due to instability caused by osteolysis around the wires. A cast was placed for 3 weeks. Although the bone transport had resulted in formation of approximately 4 cm of bone, the antebrachium showed approximately 50% shortening when compared to the contralateral limb. The infection was eradicated, and the dog was able to bear weight on the operated limb when walking.