904 resultados para PASSIVE FIT
Resumo:
Use of remotely sensed data for environmental and ecological assessment has recently become more widespread in wetland research and management and advantages and limitations of this approach have been addresses (Ozesmi and Bauer 2002). Applications of remote sensing (RS) methods vary in spatial and temporal extent and resolution, in the types of data acquired, and in digital processing and pattern recognition algorithms used.
Resumo:
GOG-Fit è un servizio che offre maschere da neve personalizzate, stampate in 3D su misura del cliente. Il modello di maschera prodotto è composto da due moduli, uniti tra loro grazie a incastri magnetici.
Resumo:
Acknowledgements GIA is grateful for funding from the Carnegie Trust for the Universities of Scotland that enabled fieldwork for this project. RW was supported by the Israel Science Foundation (ISF grant No. 1245/11). SM was supported by the Israel Science Foundation (ISF grant No. 1436/14). We would like to thank Chris Talbot and Yohann Poprawski for careful and constructive reviews. The authors appreciate the help of Nicolas Waldmann in precisely locating the positons of dated unconformities.
Resumo:
Peer reviewed
Resumo:
Peer reviewed
Resumo:
Peer reviewed
Resumo:
The aim of this study was to present a new methodology for evaluating the pelvic floor muscle (PFM) passive properties. The properties were assessed in 13 continent women using an intra-vaginal dynamometric speculum and EMG (to ensure the subjects were relaxed) in four different conditions: (1) forces recorded at minimal aperture (initial passive resistance); (2) passive resistance at maximal aperture; (3) forces and passive elastic stiffness (PES) evaluated during five lengthening and shortening cycles; and (4) percentage loss of resistance after 1 min of sustained stretch. The PFMs and surrounding tissues were stretched, at constant speed, by increasing the vaginal antero-posterior diameter; different apertures were considered. Hysteresis was also calculated. The procedure was deemed acceptable by all participants. The median passive forces recorded ranged from 0.54 N (interquartile range 1.52) for minimal aperture to 8.45 N (interquartile range 7.10) for maximal aperture while the corresponding median PES values were 0.17 N/mm (interquartile range 0.28) and 0.67 N/mm (interquartile range 0.60). Median hysteresis was 17.24 N∗mm (interquartile range 35.60) and the median percentage of force losses was 11.17% (interquartile range 13.33). This original approach to evaluating the PFM passive properties is very promising for providing better insight into the patho-physiology of stress urinary incontinence and pinpointing conservative treatment mechanisms.
Resumo:
Mémoire numérisé par la Direction des bibliothèques de l'Université de Montréal.
Resumo:
This paper reports on an investigation with first year undergraduate Product Design and Management students within a School of Engineering. The students at the time of this investigation had studied fundamental engineering science and mathematics for one semester. The students were given an open ended, ill formed problem which involved designing a simple bridge to cross a river. They were given a talk on problem solving and given a rubric to follow, if they chose to do so. They were not given any formulae or procedures needed in order to resolve the problem. In theory, they possessed the knowledge to ask the right questions in order to make assumptions but, in practice, it turned out they were unable to link their a priori knowledge to resolve this problem. They were able to solve simple beam problems when given closed questions. The results show they were unable to visualise a simple bridge as an augmented beam problem and ask pertinent questions and hence formulate appropriate assumptions in order to offer resolutions.
Resumo:
Marine mammals exploit the efficiency of sound propagation in the marine environment for essential activities like communication and navigation. For this reason, passive acoustics has particularly high potential for marine mammal studies, especially those aimed at population management and conservation. Despite the rapid realization of this potential through a growing number of studies, much crucial information remains unknown or poorly understood. This research attempts to address two key knowledge gaps, using the well-studied bottlenose dolphin (Tursiops truncatus) as a model species, and underwater acoustic recordings collected on four fixed autonomous sensors deployed at multiple locations in Sarasota Bay, Florida, between September 2012 and August 2013. Underwater noise can hinder dolphin communication. The ability of these animals to overcome this obstacle was examined using recorded noise and dolphin whistles. I found that bottlenose dolphins are able to compensate for increased noise in their environment using a wide range of strategies employed in a singular fashion or in various combinations, depending on the frequency content of the noise, noise source, and time of day. These strategies include modifying whistle frequency characteristics, increasing whistle duration, and increasing whistle redundancy. Recordings were also used to evaluate the performance of six recently developed passive acoustic abundance estimation methods, by comparing their results to the true abundance of animals, obtained via a census conducted within the same area and time period. The methods employed were broadly divided into two categories – those involving direct counts of animals, and those involving counts of cues (signature whistles). The animal-based methods were traditional capture-recapture, spatially explicit capture-recapture (SECR), and an approach that blends the “snapshot” method and mark-recapture distance sampling, referred to here as (SMRDS). The cue-based methods were conventional distance sampling (CDS), an acoustic modeling approach involving the use of the passive sonar equation, and SECR. In the latter approach, detection probability was modelled as a function of sound transmission loss, rather than the Euclidean distance typically used. Of these methods, while SMRDS produced the most accurate estimate, SECR demonstrated the greatest potential for broad applicability to other species and locations, with minimal to no auxiliary data, such as distance from sound source to detector(s), which is often difficult to obtain. This was especially true when this method was compared to traditional capture-recapture results, which greatly underestimated abundance, despite attempts to account for major unmodelled heterogeneity. Furthermore, the incorporation of non-Euclidean distance significantly improved model accuracy. The acoustic modelling approach performed similarly to CDS, but both methods also strongly underestimated abundance. In particular, CDS proved to be inefficient. This approach requires at least 3 sensors for localization at a single point. It was also difficult to obtain accurate distances, and the sample size was greatly reduced by the failure to detect some whistles on all three recorders. As a result, this approach is not recommended for marine mammal abundance estimation when few recorders are available, or in high sound attenuation environments with relatively low sample sizes. It is hoped that these results lead to more informed management decisions, and therefore, more effective species conservation.
Resumo:
The aim of this study was to present a new methodology for evaluating the pelvic floor muscle (PFM) passive properties. The properties were assessed in 13 continent women using an intra-vaginal dynamometric speculum and EMG (to ensure the subjects were relaxed) in four different conditions: (1) forces recorded at minimal aperture (initial passive resistance); (2) passive resistance at maximal aperture; (3) forces and passive elastic stiffness (PES) evaluated during five lengthening and shortening cycles; and (4) percentage loss of resistance after 1 min of sustained stretch. The PFMs and surrounding tissues were stretched, at constant speed, by increasing the vaginal antero-posterior diameter; different apertures were considered. Hysteresis was also calculated. The procedure was deemed acceptable by all participants. The median passive forces recorded ranged from 0.54 N (interquartile range 1.52) for minimal aperture to 8.45 N (interquartile range 7.10) for maximal aperture while the corresponding median PES values were 0.17 N/mm (interquartile range 0.28) and 0.67 N/mm (interquartile range 0.60). Median hysteresis was 17.24 N∗mm (interquartile range 35.60) and the median percentage of force losses was 11.17% (interquartile range 13.33). This original approach to evaluating the PFM passive properties is very promising for providing better insight into the patho-physiology of stress urinary incontinence and pinpointing conservative treatment mechanisms.
Resumo:
Mémoire numérisé par la Direction des bibliothèques de l'Université de Montréal.
Resumo:
Goodness-of-fit tests have been studied by many researchers. Among them, an alternative statistical test for uniformity was proposed by Chen and Ye (2009). The test was used by Xiong (2010) to test normality for the case that both location parameter and scale parameter of the normal distribution are known. The purpose of the present thesis is to extend the result to the case that the parameters are unknown. A table for the critical values of the test statistic is obtained using Monte Carlo simulation. The performance of the proposed test is compared with the Shapiro-Wilk test and the Kolmogorov-Smirnov test. Monte-Carlo simulation results show that proposed test performs better than the Kolmogorov-Smirnov test in many cases. The Shapiro Wilk test is still the most powerful test although in some cases the test proposed in the present research performs better.
Resumo:
Esta investigación pretende (re)pensar el fitness como práctica socio-cultural moderna, observando aquellos discursos que la atraviesan y constituyen. Entre otros, se destaca el análisis de significaciones que son particulares al contexto de los gimnasios, en los cuales se desarrollan ideales distintivos de belleza o de salud, métodos de entrenamiento que responden a ?escuelas? o tendencias empresariales, ?habilidades corporales? que son ponderadas o menospreciadas, sentidos y sensibilidades legitimadostransmitidos como valores o técnicas y prácticas específicas condicionadas por los materiales utilizados. Para ello se propone reflexionar acerca de la compañía internacional ?BodySystems?, indagando aquellas prácticas desarrolladas en sus sucursales de La Plata, a través de tres técnicas de recolección de datos: el análisis de los documentos que la empresa proporciona a sus instructores, el estudio de los discursos que se desprenden de las clínicas que la compañía dicta cada tres meses y la reflexión sobre las entrevistas realizadas a los profesionales que desempeñan sus actividades en estos establecimientos. Para ello, se ponen en juego dos categorías de análisis que son características de la cultura fitness: los agentes que participan en los gimnasios constituyéndose en clientes de un cuerpo yla construcción y reproducción del "fit-body" característico de las empresas gímnicas