975 resultados para Orthopedic implants


Relevância:

10.00% 10.00%

Publicador:

Resumo:

This study was evaluated the response of subcutaneous connective tissue of isogenic mice to calcium hydroxide-based pastes with chlorhexidine digluconate (CHX). Seventy isogenic male BALB/c mice aged 6-8 weeks and weighing 15-20 g were randomly assigned to 8 groups. The animals received polyethylene tube implants as follows: Groups I, II, and III (n=10) - Calen® paste mixed with 0.4% CHX (experimental paste; Calen/CHX) for 7, 21, and 63 days, respectively; Groups IV, V, and VI (n=10) - UltraCal™ paste mixed with 2% CHX (experimental paste supplied by Ultradent Products Inc.; Ultracal/CHX) for 7, 21, and 63 days, respectively; and Groups VII and VIII (n=5): empty tube for 7 and 21 days, respectively. At the end of the experimental periods, the implants were removed together with the surrounding tissues (skin and subcutaneous connective tissue). The biopsied tissues were subjected to routine processing for histological analysis. Using a descriptive analysis and a four-point (0-3) scoring system, the following criteria were considered for qualitative and quantitative analysis of the tissue around the implanted materials: collagen fiber formation, tissue thickness and inflammatory infiltrate. A quantitative analysis was performed by measuring the thickness (µm), area (µm²) and perimeter (µm) of the reactionary granulomatous tissue formed at the tube ends. Data were analyzed statistically by the Kruskal-Wallis test and Dunn's post-test (α=0.05). Calen/CHX showed biocompatibility with the subcutaneous and reactionary tissues, with areas of discrete fibrosis and normal conjunctive fibrous tissue, though without statistically significant difference (p>0.05) from the control groups. In Groups I to III, there was a predominance of score 1, while in Groups IV to VI scores 2 and 3 predominated for all analyzed parameters. UltraCal/CHX, on the other hand, induced the formation of an inflammatory infiltrate and abundant exudate, suggesting a persistent residual aggression from the material, even 63 days after implant placement. In conclusion, the Calen paste mixed with 0.4% CHX allowed an adequate tissue response, whereas the UltraCal paste mixed with 2% CHX showed unsatisfactory results.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This study evaluated the loss of the torque applied after use of new screws and after successive tightening. Four infrastructures (IE), using UCLA castable abutment type, were cast in cobalt-chromium alloy and new abutment screws (G1) were used in a first moment. Subsequently, the same abutment screws were used a second time (G2) and more than two times (G3). The values of the torques applied and detorques were measured with a digital torque wrench to obtain the values of initial tightening loss (%). Data were analyzed by ANOVA and Tukey's test (?=0.05). Significant differences were observed between the G1 (50.71% ± 11.36) and G2 (24.01% ± 3.33) (p=0.000) and between G1 (50.71% ± 11.36) and G3 (25.60% ± 4.64) (p=0.000). There was no significant difference between G2 and G3 (p=0.774). Within the limitations of the study, it may be concluded that the percentage of the initial torque loss is lower when screws that already suffered the application of an initial torque were used, remaining stable after application of successive torques.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This study investigated whether there is a direct correlation between the level of vertical misfit at the abutment/implant interface and torque losses (detorque) in abutment screws. A work model was obtained from a metal matrix with five 3.75 x 9 mm external hex implants with standard platform (4.1 mm). Four frameworks were waxed using UCLA type abutments and one-piece cast in commercially pure titanium. The misfit was analyzed with a comparator microscope after 20 Ncm torque. The highest value of misfit observed per abutment was used. The torque required to loose the screw was evaluated using a digital torque meter. The torque loss values, measured by the torque meter, were assumed as percentage of initial torque (100%) given to abutment screws. Pearson's correlation (α=0.05) between the misfit values (29.08 ± 8.78 µm) and the percentage of detorque (50.71 ± 11.37%) showed no statistically significant correlation (p=0.295). Within the limitations of this study, it may be concluded that great vertical misfits dot not necessarily implies in higher detorque values.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This article addresses diagnostic parameters that should be assessed in the treatment of extraction sockets with dental implant placement by presenting three case reports that emphasize the relevance of the amount of remaining bone walls. Diagnosis was based on the analysis of clinical and radiographic parameters (e.g.: bone defect morphology, remaining bone volume, presence of infections on the receptor site). Case 1 presents a 5-wall defect in the maxillary right central incisor region with severe root resorption, which was treated with immediate implant placement. Cases 2 and 3 present, respectively, two- and three-wall bone defects that did not have indication for immediate implants. These cases were first submitted to a guided bone regeneration (GBR) procedure with bone graft biomaterial and membrane barriers, and the implants were installed in a second surgical procedure. The analysis of the preoperative periodontal condition of the adjacent teeth and bone defect morphology is extremely important because these factors determine the choice between immediate implant or GBR treatment followed by implant installation in a subsequent intervention.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A medula espinhal dos mamíferos adultos não permite a regeneração de axônios. Por razões ainda desconhecidas, as fibras neurais falham em cruzar o sítio da lesão, como se não houvesse crescimento, desde a primeira tentativa. Quais mecanismos poderiam explicar a perda da capacidade de regeneração? As cicatrizes formadas pelas células da glia seriam uma consequência da falha na regeneração ou a causa? Diversas linhas de evidência sugerem que a regeneração da medula espinhal seria impedida no sistema nervoso central pela ação de fatores locais no sítio da lesão, e que o sistema nervoso central não-lesado é um meio permissivo para o crescimento axonal, na direção de alvos específicos. Uma vez que os axônios são induzidos adequadamente a cruzar a lesão com o auxílio de implantes, fármacos ou células indiferenciadas, as fibras em regeneração podem encontrar a via específica e estabelecer conexões corretas. O que ainda não se sabe é que combinação de moléculas induz/inibe o potencial de regeneração do tecido e que mecanismos permitem aos neurônios formarem conexões específicas com os alvos com os quais são programados a fazer.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJETIVO: Verificar a prevalência e os fatores associados aos hábitos de sucção não nutritiva em crianças pré-escolares matriculadas em creches e pré-escolas de Natal (RN). MÉTODOS: Foi conduzido um estudo transversal com 1.190 crianças de ambos os sexos na faixa etária de 3 a 5 anos, matriculadas em creches e pré-escolas de Natal. Não foram incluídas no estudo crianças com fendas labiopalatinas, desordens temporomandibulares, ou aquelas submetidas a tratamento ortodôntico e/ou ortopédico; também não fizeram parte da amostra instituições de ensino especializadas em crianças portadoras de deficiência. Utilizou-se um questionário estruturado, respondido pelos pais ou responsável, com dados sobre a instituição, sexo e idade das crianças, escolaridade dos pais e questões relacionadas aos hábitos. A análise dos dados foi realizada através do teste do qui-quadrado e a regressão logística. RESULTADOS: Obteve-se prevalência de 40,2% de hábitos de sucção não nutritiva, dos quais 27,7% eram de sucção de chupeta e 12,5% de dedo. Os hábitos de sucção apresentaram maior percentual para o sexo feminino, destacando-se a sucção de dedo (p = 0,02); em crianças com menos idade destacou-se a sucção de chupeta (p = 0,0006). Observou-se maior frequência de sucção de chupeta e de dedo, respectivamente, para o nível superior (p < 0,05) e fundamental (p < 0,05) de escolaridade dos pais. A regressão logística demonstrou que a menor idade dos indivíduos (p = 0,033) e o nível médio de escolaridade dos pais (p = 0,035) são fatores independentes para a persistência dos hábitos. CONCLUSÃO: Verificou-se uma alta prevalência de realização dos hábitos de sucção não nutritiva, apresentando como fatores de destaque a menor idade das crianças e o nível médio de escolaridade dos pais.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This study evaluated bone response to a Ca- and P- enriched titanium (Ti) surface treated by a multiphase anodic spark deposition coating (BSP-AK). Two mongrel dogs received bilateral implantation of 3 Ti cylinders (4.1 x 12 mm) in the humerus, being either BSP-AK treated or untreated (machined - control). At 8 weeks postimplantation, bone fragments containing the implants were harvested and processed for histologic and histomorphometric analyses. Bone formation was observed in cortical area and towards the medullary canal associated to approximately 1/3 of implant extension. In most cases, in the medullary area, collagen fiber bundles were detected adjacent and oriented parallel to Ti surfaces. Such connective tissue formation exhibited focal areas of mineralized matrix lined by active osteoblasts. The mean percentages of bone-to-implant contact were 2.3 (0.0-7.2 range) for BSP-AK and 0.4 (0.0-1.3 range) for control. Although the Mann-Whitney test did not detect statistically significant differences between groups, these results indicate a trend of BSP-AK treated surfaces to support contact osteogenesis in an experimental model that produces low bone-to-implant contact values.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

With the increase in life expectancy, biomaterials have become an increasingly important focus of research because they are used to replace parts and functions of the human body, thus contributing to improved quality of life. In the development of new biomaterials, the Ti-15Mo alloy is particularly significant. In this study, the Ti-15Mo alloy was produced using an arc-melting furnace and then characterized by density, X-ray diffraction, optical microscopy, hardness and dynamic elasticity modulus measurements, and cytotoxicity tests. The microstructure was obtained with β predominance. Microhardness, elasticity modulus, and cytotoxicity testing results showed that this material has great potential for use as biomaterial, mainly in orthopedic applications.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aim of this study was to verify whether screw abutment lubrication can generate higher preload values compared to non-lubricated screws, a titanium abutment was screwed onto an implant analog and scanned with the Procera System to generate 20 zirconia abutments. MKIII Brånemark implants were clamped to a precision torque device, and the abutments were distributed in dry and wet groups with 10 specimens each. In the wet groups, the inner threads of the implants were filled with artificial saliva. All abutments were fastened with a Torqtite screw under 32 Ncm. Ten detorque measurements were performed per group pushing the reverse button of the Torque controller soon after screw tightening with values registered. The mean detorque values were calculated and compared by a Student's t test (?=0.05). The wet condition presented significantly higher mean detorque than the dry condition (31.5 ± 1.2 versus 27.5 ± 1.5 Ncm, respectively; p=0.0000024). In conclusion, there was always a loss in the initial torque values when the removal torque was measured under both conditions. The wet condition presented higher mean torque than the dry condition. Better preload values were established in the wet group, suggesting that the abutment screw must be lubricated in saliva to avoid further loosening.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Limiares auditivos de crianças surdas pré-linguais usuárias de implante coclear foram avaliados com estimulação elétrica em um dos eletrodos mediais. A avaliação empregou um procedimento operante do tipo go/no go para ensinar uma discriminação simples, evidenciada por uma resposta motora, entre presença e ausência do estímulo auditivo. Estabelecida a linha de base, a manipulação na intensidade do estímulo foi implementada de acordo com o método psicofísico de escada modificado, começando por uma seqüência descendente. Os sete participantes do estudo mostraram perda da precisão no responder sob controle do estímulo quando a intensidade diminuía além de um certo valor e a precisão era recuperada quando a intensidade era novamente aumentada, o que permitiu a identificação de limiares individuais. Os resultados sugerem que o método psicofísico combinado com o procedimento operante pode ser uma alternativa viável para avaliar limiar auditivo de pessoas sem linguagem em situação clínica de regulagem do implante coclear.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

INTRODUÇÃO: A Prótese Implantável de Condução Óssea (BAHA) consiste em uma excelente opção na reabilitação auditiva de pacientes com perda auditiva condutiva e mista uni ou bilateral, e sensorioneural unilateral. Tem sido uma alternativa vantajosa sobre os aparelhos de condução óssea convencionais e os aparelhos de amplificação sonora individuais (AASI) quando o uso dos mesmos fica impossibilitado pela presença de otite externa crônica de difícil controle clínico. OBJETIVO: Apresentar o primeiro caso de BAHA realizado no Brasil, após a autorização da ANVISA, para a reabilitação da perda auditiva mista com episódios de otite externa crônica. MÉTODO: Paciente do sexo feminino, 50 anos, com perda auditiva de grau moderado à direita e severo à esquerda, zumbido bilateral, decorrente de otosclerose, submetida a quatro cirurgias de estapedotomia e com impossibilidade de uso de AASI devido a otorreia e otalgia bilateral. A avaliação médica e audiológica indicaram o benefício do BAHA. Realizada a cirurgia e implantação do sistema BAHA, a paciente apresentou melhora significativa nos limiares audiométricos, na percepção e discriminação da fala, além de relatar extrema satisfação relacionada ao fator estético. COMENTÁRIOS FINAIS: O processo cirúrgico do BAHA é seguro, simples e rápido, proporcionando excelentes resultados audiológicos e alto grau de satisfação por parte dos pacientes.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJETIVO: A hipotermia é prejudicial no período perioperatório. Não há consenso sobre o melhor método de aquecimento ativo e nem sobre o melhor período para fazê-lo. Este estudo teve como objetivo primário verificar a eficácia de diferentes períodos de utilização da manta térmica à temperatura de 38°C, como método de prevenção da hipotermia intraoperatória. Como objetivo secundário avaliou-se os efeitos adversos do uso da manta térmica na temperatura de 38°C. MÉTODOS: Foram comparados quatro grupos de 15 pacientes submetidos a operações ortopédicas. No grupo controle (Gcont) os pacientes não utilizaram manta térmica, nos grupos pré (Gpré), intra (Gintra) e total (Gtotal), os pacientes utilizaram manta térmica a 38ºC, respectivamente, durante 30 minutos antes da indução anestésica, após a indução anestésica até 120 minutos e antes e após a indução. Foram avaliados: temperatura central (timpânica), periférica (pele), da sala cirúrgica, variação das condições hemodinâmicas e efeitos adversos do aquecimento. RESULTADOS: O Gtotal foi o único grupo que não teve variação significativa da temperatura central. A temperatura central dos pacientes do grupo Gtotal foi significativamente maior (p <0,05) do que a dos outros grupos aos 60 e 120 min após a indução. Os pacientes dos grupos Gcont, Gpré e Gintra apresentaram hipotermia aos 60 min. CONCLUSÃO: O uso da manta térmica com fluxo de ar aquecido foi eficaz como método de prevenção da hipotermia intraoperatória quando foi empregada desde 30 min antes da indução anestésica até 120 min após o início da anestesia. Nas condições do estudo não ocorreram eventos adversos.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The maxilla and masseter muscles are components of the stomatognathic system involved in chewing, which is frequently affected by physical forces such as gravity, and by dental, orthodontic and orthopedic procedures. Thyroid hormones (TH) are known to regulate the expression of genes that control bone mass and the oxidative properties of muscles; however, little is known about the effects of TH on the stomatognathic system. This study investigated this issue by evaluating: i) osteoprotegerin (OPG) and osteopontine (OPN) mRNA expression in the maxilla and ii) myoglobin (Mb) mRNA and protein expression, as well as fiber composition of the masseter. Male Wistar rats (~250 g) were divided into thyroidectomized (Tx) and sham-operated (SO) groups (N = 24/group) treated with T3 or saline (0.9%) for 15 days. Thyroidectomy increased OPG (~40%) and OPN (~75%) mRNA expression, while T3 treatment reduced OPG (~40%) and OPN (~75%) in Tx, and both (~50%) in SO rats. Masseter Mb mRNA expression and fiber type composition remained unchanged, despite the induction of hypo- and hyperthyroidism. However, Mb content was decreased in Tx rats even after T3 treatment. Since OPG and OPN are key proteins involved in the osteoclastogenesis inhibition and bone mineralization, respectively, and that Mb functions as a muscle store of O2 allowing muscles to be more resistant to fatigue, the present data indicate that TH also interfere with maxilla remodeling and the oxidative properties of the masseter, influencing the function of the stomatognathic system, which may require attention during dental, orthodontic and orthopedic procedures in patients with thyroid diseases.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

O objetivo deste trabalho foi avaliar a distribuição de tensões na resina em contato com os filetes de roscas de mini-implantes cilíndricos e cônicos, submetidos à carga lateral e torção de inserção. Um modelo fotoelástico foi confeccionado com gelatina transparente, para simular o osso alveolar. O modelo foi observado com um polariscópio plano e fotografado antes e após a ativação dos mini-implantes com força lateral e de inserção. A aplicação de cargas laterais provocou momentos fletores nos mini-implantes, aparecimento de franjas isocromáticas ao longo dos filetes do corpo dos mini-implantes e no ápice. Quando foi aplicado o torque de inserção, verificou-se a concentração de tensões próxima ao ápice. Concluiu-se que: (1) o mini-implante cilíndrico apresentou maior concentração de tensões no ápice, e (2) o mini-implante cônico apresentou maior concentração de tensões nos filetes de rosca apicais.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Na tentativa de evitar algumas das dificuldades associadas à osteotomia pélvica tripla (OPT), foi desenvolvido experimentalmente o método de aplicação de cunha na junção sacroilíaca para aumentar a ventroversão acetabular. O objetivo deste estudo foi aplicar as técnicas de cunha sacroilíaca e OPT em cadáveres e avaliar radiograficamente a eficácia da ventroversão acetabular. Para tal, foram utilizados 10 cadáveres de cães, adultos, com 15-25 kg. Em cada hemipelve direita foi realizada OPT com placas de 20° e 40°. Na hemipelve esquerda foram aplicadas cunhas nas articulações sacroilíacas de 20° e 40°. Avaliações radiográficas em projeções ventrodorsais foram realizadas para mensuração da cobertura acetabular à cabeça femoral nas duas técnicas. De acordo com os dados obtidos pode-se observar que não houve diferença entre a técnica de OPT e o uso de cunha sacroilíaca utilizando implantes de 20° e 40°, mas ocorreu diferença significativa (p<0,05) entre os cães antes e após a aplicação dos implantes de 20° e 40°, e também entre os que receberam implantes de 20° e os de 40°. A aplicação de cunha sacroilíaca produziu resultados semelhantes à OPT, e também se mostrou como de mais fácil aplicação.