1000 resultados para Orbital mechanics


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Recent studies of dental microwear and craniofacial mechanics have yielded contradictory interpretations regarding the feeding ecology and adaptations of Australopithecus africanus. As part of this debate, the methods used in the mechanical studies have been criticized. In particular, it has been claimed that finite element analysis has been poorly applied to this research question. This paper responds to some of these mechanical criticisms, highlights limitations of dental microwear analysis, and identifies avenues of future research.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: The time course of impairment of respiratory mechanics and gas exchange in the acute respiratory distress syndrome (ARDS) remains poorly defined. We assessed the changes in respiratory mechanics and gas exchange during ARDS. We hypothesized that due to the changes in respiratory mechanics over time, ventilatory strategies based on rigid volume or pressure limits might fail to prevent overdistension throughout the disease process. METHODS: Seventeen severe ARDS patients {PaO2/FiO2 10.1 (9.2-14.3) kPa; 76 (69-107) mmHg [median (25th-75th percentiles)] and bilateral infiltrates} were studied during the acute, intermediate, and late stages of ARDS (at 1-3, 4-6 and 7 days after diagnosis). Severity of lung injury, gas exchange, and hemodynamics were assessed. Pressure-volume (PV) curves of the respiratory system were obtained, and upper and lower inflection points (UIP, LIP) and recruitment were estimated. RESULTS: (1) UIP decreased from early to established (intermediate and late) ARDS [30 (28-30) cmH2O, 27 (25-30) cmH2O and 25 (23-28) cmH2O (P=0.014)]; (2) oxygenation improved in survivors and in patients with non-pulmonary etiology in late ARDS, whereas all patients developed hypercapnia from early to established ARDS; and (3) dead-space ventilation and pulmonary shunt were larger in patients with pulmonary etiology during late ARDS. CONCLUSION: We found a decrease in UIP from acute to established ARDS. If applied to our data, the inspiratory pressure limit advocated by the ARDSnet (30 cmH2O) would produce ventilation over the UIP, with a consequent increased risk of overdistension in 12%, 43% and 65% of our patients during the acute, intermediate and late phases of ARDS, respectively. Lung protective strategies based on fixed tidal volume or pressure limits may thus not fully avoid the risk of lung overdistension throughout ARDS.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

High-frequency respiratory impedance data measured noninvasively by the high-speed interrupter technique (HIT), particularly the first antiresonance frequency (f(ar,1)), is related to airway wall mechanics. The aim of this study was to evaluate the feasibility and repeatability of HIT in unsedated pre-term infants, and to compare values of f(ar,1) from 18 pre-term (post-conceptional age 32-37 weeks, weight 1,730-2,910 g) and 18 full-term infants (42-47 weeks, 3,920-5,340 g). Among the pre-term infants, there was good short-term repeatability of f(ar,1) within a single sleep epoch (mean (sd) coefficient of variance: 8 (1.7)%), but 95% limits of agreement for repeated measures of f(ar,1) after 3-8 h were relatively wide (-41 Hz; 37 Hz). f(ar,1) was significantly lower in pre-term infants (199 versus 257 Hz), indicating that wave propagation characteristics in pre-term airways are different from those of full-term infants. The present authors suggest that this is consistent with developmental differences in airway wall structure and compliance, including the influence of the surrounding tissue. Since flow limitation is determined by wave propagation velocity and airway cross-sectional area, it was hypothesised that the physical ability of the airways to carry large flows is fundamentally different in pre-term than in full-term infants.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This retrospective study describes the clinical and magnetic resonance (MR) imaging features of chronic orbital inflammation with intracranial extension in four dogs (two Dachshunds, one Labrador, one Swiss Mountain). Intracranial extension was observed through the optic canal (n=1), the orbital fissure (n=4), and the alar canal (n=1). On T1-weighted images structures within the affected skull foramina could not be clearly differentiated, but were all collectively isointense to hypointense compared with the contralateral, unaffected side, or compared with gray matter. On T2-, short tau inversion recovery (STIR)-, or fluid-attenuated inversion recovery (FLAIR)-weighted images structures within the affected skull foramina appeared hyperintense compared with gray matter, and extended with increased signal into the rostral cranial fossa (n=1) and middle cranial fossa (n=4). Contrast enhancement at the level of the affected skul foramina as well as at the skull base in continuity with the orbital fissure was observed in all patients. Brain edema or definite meningeal enhancement could not be observed, but a close anatomic relationship of the abnormal tissue to the cavernous sinus was seen in two patients. Diagnosis was confirmed in three dogs (one cytology, two biopsy, one necropsy) and was presumptive in one based on clinical improvement after treatment. This study is limited by its small sample size, but provides evidence for a potential risk of intracranial extension of chronic orbital inflammation. This condition can be identified best by abnormal signal increase at the orbital fissure on transverse T2-weighted images, on dorsal STIR images, or on postcontrast transverse or dorsal images.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Respiratory system input impedance (Zrs) at low to medium frequencies below 100 Hz, and study of its volume dependence, have been used extensively to quantify airway and tissue mechanics. Zrs at high oscillation frequencies including the first antiresonant frequency (far,1) may contain important information about airway mechanics. Changes in high-frequency Zrs with lung volume have not been studied. The volume-dependent behavior of high-frequency Zrs, specifically far,1 and respiratory system resistance at first antiresonance (Rrs(far,1)), was characterized in 16 healthy adults. Zrs was measured with a forced oscillation signal (5-302.5 Hz) through a wavetube setup. To track Zrs, subjects performed slow deep inspiratory and expiratory maneuvers over 30-s measurements, during which average impedance was calculated over 0.4-s intervals, with successive overlapping estimates every 0.156 s. Flow was measured using a pneumotachometer and integrated to obtain volume. Transpulmonary pressure dependence (Ptp) of Zrs was separately determined in five subjects. Both far,1 and Rrs(far,1) decreased with increasing lung volume and Ptp, consistent with an increase in airway caliber and decreased airway wall compliance as volume increased. These characterizations provide insight into airway mechanics, and are furthermore a necessary first step toward determining whether volume dependence of the first antiresonance is altered in disease.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Reconstruction of the anterior skull base and fronto-orbital framework following extensive tumor resection is both challenging and controversial. Dural defects are covered with multiple sheets of fascia lata that provide sufficient support and avoid herniation. Plating along the skull base is contraindicated. After resection of orbital walls, grafting is necessary if the periosteum or parts of the periorbital tissue had to be removed, to avoid enophthalmus or strabism. Free bone grafts exposed to the sinonasal or pharyngeal cavity are vulnerable to infection or necrosis: therefore, covering the grafts with vascularized tissue, such as the Bichat fat-pad or pedicled temporalis flaps, should reduce these complications. Alloplastic materials are indispensable in cranial defects, whereas microsurgical free tissue transfer is indicated in cases of orbital exenteration and skin defects. The authors review their experience and follow-up of 122 skull base reconstructions following extensive subcranial tumor resection. Most significant complications were pneumocranium in 4.9%, CSF leaks in 3.2%, and partial bone resorption in 8.1%.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Whipple's disease is a systemic disorder caused by an infection with a gram-positive bacillus, Tropheryma whipplei. Almost every organ system can be affected in Whipple's disease, resulting in varying clinical symptoms. CASE REPORT: As far as we are aware, this report of a 61-year-old male is the first presenting with a periorbital manifestation of the disease, with severe exophthalmos and optic nerve involvement, leading to rapid visual loss. This emergency case was successfully treated by a surgical orbital decompression combined with systemic use of antibiotics and steroids. CONCLUSION: Whipple's disease can affect the periorbital tissues and the optic nerve, causing massive exophthalmos and serious transient visual loss. In such a case surgical decompression of the affected orbit combined with antibiotics and steroids is a recommended valid treatment option.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To report the efficacy of percutaneous treatment of an orbital venous malformation with an electrolytically detachable fibred coil. METHODS: We report an instance of radiography-guided percutaneous treatment with an electrolytically detachable fibred coil in a 16-year-old boy with acute, spontaneous, painless proptosis on the left side, which progressed with time. RESULTS: Magnetic resonance imaging, angiography and orbitophlebography revealed a low-flow, intraorbital venous malformation. Percutaneous puncture and drainage were followed by a short remission. Following an acute recurrence, a single detachable fibred coil was deployed via a percutaneous approach under angiographic guidance. No radiological or clinical recurrences were observed over 4 years. CONCLUSIONS: Embolization of a deep orbital venous malformation with detachable fibred coils via a percutaneous approach can be highly effective, and may be considered before proceeding with open surgery.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The study of advanced materials aimed at improving human life has been performed since time immemorial. Such studies have created everlasting and greatly revered monuments and have helped revolutionize transportation by ushering the age of lighter–than–air flying machines. Hence a study of the mechanical behavior of advanced materials can pave way for their use for mankind’s benefit. In this school of thought, the aim of this dissertation is to broadly perform two investigations. First, an efficient modeling approach is established to predict the elastic response of cellular materials with distributions of cell geometries. Cellular materials find important applications in structural engineering. The approach does not require complex and time-consuming computational techniques usually associated with modeling such materials. Unlike most current analytical techniques, the modeling approach directly accounts for the cellular material microstructure. The approach combines micropolar elasticity theory and elastic mixture theory to predict the elastic response of cellular materials. The modeling approach is applied to the two dimensional balsa wood material. Predicted properties are in good agreement with experimentally determined properties, which emphasizes the model’s potential to predict the elastic response of other cellular solids, such as open cell and closed cell foams. The second topic concerns intraneural ganglion cysts which are a set of medical conditions that result in denervation of the muscles innervated by the cystic nerve leading to pain and loss of function. Current treatment approaches only temporarily alleviate pain and denervation which, however, does not prevent cyst recurrence. Hence, a mechanistic understanding of the pathogenesis of intraneural ganglion cysts can help clinicians understand them better and therefore devise more effective treatment options. In this study, an analysis methodology using finite element analysis is established to investigate the pathogenesis of intraneural ganglion cysts. Using this methodology, the propagation of these cysts is analyzed in their most common site of occurrence in the human body i.e. the common peroneal nerve. Results obtained using finite element analysis show good correlation with clinical imaging patterns thereby validating the promise of the method to study cyst pathogenesis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Skeletal muscle force evaluation is difficult to implement in a clinical setting. Muscle force is typically assessed through either manual muscle testing, isokinetic/isometric dynamometry, or electromyography (EMG). Manual muscle testing is a subjective evaluation of a patient’s ability to move voluntarily against gravity and to resist force applied by an examiner. Muscle testing using dynamometers adds accuracy by quantifying functional mechanical output of a limb. However, like manual muscle testing, dynamometry only provides estimates of the joint moment. EMG quantifies neuromuscular activation signals of individual muscles, and is used to infer muscle function. Despite the abundance of work performed to determine the degree to which EMG signals and muscle forces are related, the basic problem remains that EMG cannot provide a quantitative measurement of muscle force. Intramuscular pressure (IMP), the pressure applied by muscle fibers on interstitial fluid, has been considered as a correlate for muscle force. Numerous studies have shown that an approximately linear relationship exists between IMP and muscle force. A microsensor has recently been developed that is accurate, biocompatible, and appropriately sized for clinical use. While muscle force and pressure have been shown to be correlates, IMP has been shown to be non-uniform within the muscle. As it would not be practicable to experimentally evaluate how IMP is distributed, computational modeling may provide the means to fully evaluate IMP generation in muscles of various shapes and operating conditions. The work presented in this dissertation focuses on the development and validation of computational models of passive skeletal muscle and the evaluation of their performance for prediction of IMP. A transversly isotropic, hyperelastic, and nearly incompressible model will be evaluated along with a poroelastic model.