974 resultados para Operational transconductance amplifier
Resumo:
This paper presents a model for determining value at operational risk ?OpVaR? in electric utilities, with the aim to confirm the versatility of the Bank for International Settlements (BIS) proposals. The model intends to open a new methodological approach in risk management, paying special attention to underlying operational sources of risk.
Resumo:
In pressure irrigation-water distribution networks, applied water volume is usually controlled opening a valve during a calculated time interval, and assuming constant flow rate. In general, pressure regulating devices for controlling the discharged flow rate by irrigation units are needed due to the variability of pressure conditions.
Resumo:
Integrated master-oscillator power amplifiers driven under steady-state injection conditions are known to show a complex dynamics resulting in a variety of emission regimes. We present experimental results on the emission characteristics of a 1.5 µm distributed feedback tapered master-oscillator power-amplifier in a wide range of steady-state injection conditions, showing different dynamic behaviors. The study combines the optical and radio-frequency spectra recorded under different levels of injected current into the master oscillator and the power amplifier sections. Under low injection current of the master oscillator the correlation between the optical and radio-frequency spectral maps allows to identify operation regimes in which the device emission arises from either the master oscillator mode or from the compound cavity modes allowed by the residual reflectance of the amplifier front facet. The quasi-periodic occurrence of these emission regimes as a function of the amplifier current is interpreted in terms of a thermally tuned competition between the modes of the master oscillator and the compound cavity modes. Under high injection current of the masteroscillator, two different regimes alternate quasi-periodically as a function of the injected current in the power amplifier: a stable regime with a single mode emission at the master oscillator frequency, and an unstable and complex self-pulsating regime showing strong peaks in the radio-frequency spectra as well as multiple frequencies in the optical spectra.
Resumo:
Nowadays the interest in high power semiconductor devices is growing for applications such as telemetry, lidar system or free space communications. Indeed semiconductor devices can be an alternative to solid state lasers because they are more compact and less power consuming. These characteristics are very important for constrained and/or low power supply environment such as airplanes or satellites. Lots of work has been done in the 800-1200 nm range for integrated and free space Master Oscillator Power Amplifier (MOPA) [1]-[3]. At 1.5 ?m, the only commercially available MOPA is from QPC [4]: the fibred output power is about 700 mW and the optical linewidth is 500 kHz. In this paper, we first report on the simulations we have done to determine the appropriate vertical structure and architecture for a good MOPA at 1.58 ?m (section II). Then we describe the fabrication of the devices (section III). Finally we report on the optical and electrical measurements we have done for various devices (section IV).
Resumo:
Las terminales de contenedores son sistemas complejos en los que un elevado número de actores económicos interactúan para ofrecer servicios de alta calidad bajo una estricta planificación y objetivos económicos. Las conocidas como "terminales de nueva generación" están diseñadas para prestar servicio a los mega-buques, que requieren tasas de productividad que alcanzan los 300 movimientos/ hora. Estas terminales han de satisfacer altos estándares dado que la competitividad entre terminales es elevada. Asegurar la fiabilidad de las planificaciones del atraque es clave para atraer clientes, así como reducir al mínimo el tiempo que el buque permanece en el puerto. La planificación de las operaciones es más compleja que antaño, y las tolerancias para posibles errores, menores. En este contexto, las interrupciones operativas deben reducirse al mínimo. Las principales causas de dichas perturbaciones operacionales, y por lo tanto de incertidumbre, se identifican y caracterizan en esta investigación. Existen una serie de factores que al interactuar con la infraestructura y/o las operaciones desencadenan modos de fallo o parada operativa. Los primeros pueden derivar no solo en retrasos en el servicio sino que además puede tener efectos colaterales sobre la reputación de la terminal, o incluso gasto de tiempo de gestión, todo lo cual supone un impacto para la terminal. En el futuro inmediato, la monitorización de las variables operativas presenta gran potencial de cara a mejorar cualitativamente la gestión de las operaciones y los modelos de planificación de las terminales, cuyo nivel de automatización va en aumento. La combinación del criterio experto con instrumentos que proporcionen datos a corto y largo plazo es fundamental para el desarrollo de herramientas que ayuden en la toma de decisiones, ya que de este modo estarán adaptadas a las auténticas condiciones climáticas y operativas que existen en cada emplazamiento. Para el corto plazo se propone una metodología con la que obtener predicciones de parámetros operativos en terminales de contenedores. Adicionalmente se ha desarrollado un caso de estudio en el que se aplica el modelo propuesto para obtener predicciones de la productividad del buque. Este trabajo se ha basado íntegramente en datos proporcionados por una terminal semi-automatizada española. Por otro lado, se analiza cómo gestionar, evaluar y mitigar el efecto de las interrupciones operativas a largo plazo a través de la evaluación del riesgo, una forma interesante de evaluar el effecto que eventos inciertos pero probables pueden generar sobre la productividad a largo plazo de la terminal. Además se propone una definición de riesgo operativo junto con una discusión de los términos que representan con mayor fidelidad la naturaleza de las actividades y finalmente, se proporcionan directrices para gestionar los resultados obtenidos. Container terminals are complex systems where a large number of factors and stakeholders interact to provide high-quality services under rigid planning schedules and economic objectives. The socalled next generation terminals are conceived to serve the new mega-vessels, which are demanding productivity rates up to 300 moves/hour. These terminals need to satisfy high standards because competition among terminals is fierce. Ensuring reliability in berth scheduling is key to attract clients, as well as to reduce at a minimum the time that vessels stay the port. Because of the aforementioned, operations planning is becoming more complex, and the tolerances for errors are smaller. In this context, operational disturbances must be reduced at a minimum. The main sources of operational disruptions and thus, of uncertainty, are identified and characterized in this study. External drivers interact with the infrastructure and/or the activities resulting in failure or stoppage modes. The later may derive not only in operational delays but in collateral and reputation damage or loss of time (especially management times), all what implies an impact for the terminal. In the near future, the monitoring of operational variables has great potential to make a qualitative improvement in the operations management and planning models of terminals that use increasing levels of automation. The combination of expert criteria with instruments that provide short- and long-run data is fundamental for the development of tools to guide decision-making, since they will be adapted to the real climatic and operational conditions that exist on site. For the short-term a method to obtain operational parameter forecasts in container terminals. To this end, a case study is presented, in which forecasts of vessel performance are obtained. This research has been entirely been based on data gathered from a semi-automated container terminal from Spain. In the other hand it is analyzed how to manage, evaluate and mitigate disruptions in the long-term by means of the risk assessment, an interesting approach to evaluate the effect of uncertain but likely events on the long-term throughput of the terminal. In addition, a definition for operational risk evaluation in port facilities is proposed along with a discussion of the terms that better represent the nature of the activities involved and finally, guidelines to manage the results obtained are provided.
Resumo:
Operational Modal Analysis consists on estimate the modal parameters of a structure (natural frequencies, damping ratios and modal vectors) from output-only vibration measurements. The modal vectors can be only estimated where a sensor is placed, so when the number of available sensors is lower than the number of tested points, it is usual to perform several tests changing the position of the sensors from one test to the following (multiple setups of sensors): some sensors stay at the same position from setup to setup, and the other sensors change the position until all the tested points are covered. The permanent sensors are then used to merge the mode shape estimated at each setup (or partial modal vectors) into global modal vectors. Traditionally, the partial modal vectors are estimated independently setup by setup, and the global modal vectors are obtained in a postprocess phase. In this work we present two state space models that can be used to process all the recorded setups at the same time, and we also present how these models can be estimated using the maximum likelihood method. The result is that the global mode shape of each mode is obtained automatically, and subsequently, a single value for the natural frequency and damping ratio of the mode is computed. Finally, both models are compared using real measured data.
Resumo:
The last decade, scientific studies have indicated an association between air pollution to which people are exposed and wide range of adverse health outcomes. We have developed a tool which is based on a model (MM5-CMAQ) running over Europe with 50 km spatial resolution, based on EMEP annual emissions, to produce a short-term forecast of the impact on health. In order to estimate the mortality change (forecasted for the next 24 hours) we have chosen a log-linear (Poisson) regression form to estimate the concentration-response function. The parameters involved in the C-R function have been estimated based on epidemiological studies, which have been published. Finally, we have derived the relationship between concentration change and mortality change from the C-R function which is the final health impact function.
Resumo:
This project is funded by RTE, Paris, France
Resumo:
In distinction to single-stranded anticodons built of G, C, A, and U bases, their presumable double-stranded precursors at the first three positions of the acceptor stem are composed almost invariably of G-C and C-G base pairs. Thus, the “second” operational RNA code responsible for correct aminoacylation seems to be a (G,C) code preceding the classic genetic code. Although historically rooted, the two codes were destined to diverge quite early. However, closer inspection revealed that two complementary catalytic domains of class I and class II aminoacyl-tRNA synthetases (aaRSs) multiplied by two, also complementary, G2-C71 and C2-G71 targets in tRNA acceptors, yield four (2 × 2) different modes of recognition. It appears therefore that the core four-column organization of the genetic code, associated with the most conservative central base of anticodons and codons, was in essence predetermined by these four recognition modes of the (G,C) operational code. The general conclusion follows that the genetic code per se looks like a “frozen accident” but only beyond the “2 × 2 = 4” scope. The four primordial modes of tRNA–aaRS recognition are amenable to direct experimental verification.
Resumo:
Vertebrate sensory hair cells achieve high sensitivity and frequency selectivity by adding self-generated mechanical energy to low-level signals. This allows them to detect signals that are smaller than thermal molecular motion and to achieve significant resonance amplitudes and frequency selectivity despite the viscosity of the surrounding fluid. In nonmammals, a great deal of in vitro evidence indicates that the active process responsible for this amplification is intimately associated with the hair cells' transduction channels in the stereovillar bundle. Here, we provide in vivo evidence of hair-cell bundle involvement in active processes. Electrical stimulation of the inner ear of a lizard at frequencies typical for this hearing organ induced low-level otoacoustic emissions that could be modulated by low-frequency sound. The unique modulation pattern permitted the tracing of the active process involved to the stereovillar bundles of the sensory hair cells. This supports the notion that, in nonmammals, the cochlear amplifier in the hair cells is driven by a bundle motor system.
Resumo:
The genetic code is based on aminoacylation reactions where specific amino acids are attached to tRNAs bearing anticodon trinucleotides. However, the anticodon-independent specific aminoacylation of RNA minihelix substrates by bacterial and yeast tRNA synthetases suggested an operational RNA code for amino acids whereby specific RNA sequences/structures in tRNA acceptor stems correspond to specific amino acids. Because of the possible significance of the operational RNA code for the development of the genetic code, we investigated aminoacylation of synthetic RNA minihelices with a human enzyme to understand the sequences needed for that aminoacylation compared with those needed for a microbial system. We show here that the species-specific aminoacylation of glycine tRNAs is recapitulated by a species-specific aminoacylation of minihelices. Although the mammalian and Escherichia coli minihelices differ at 6 of 12 base pairs, two of the three nucleotides essential for aminoacylation by the E. coli enzyme are conserved in the mammalian minihelix. The two conserved nucleotides were shown to be also important for aminoacylation of the mammalian minihelix by the human enzyme. A simple interchange of the differing nucleotide enabled the human enzyme to now charge the bacterial substrate and not the mammalian minihelix. Conversely, this interchange made the bacterial enzyme specific for the mammalian substrate. Thus, the positional locations (if not the actual nucleotides) for the operational RNA code for glycine appear conserved from bacteria to mammals.
Resumo:
A caracterização dielétrica de um material pode ser usada como uma técnica não destrutiva para avaliar e monitorar sua qualidade, bem como no entendimento da relação estrutura-propriedade de um material, através de suas propriedades dielétricas em função da frequência, temperatura, composição química do material, dentre outros. Na literatura há escassez de trabalhos e dados de caracterização dielétrica de filmes a base de biopolímeros. Diante desse contexto, o objetivo deste trabalho foi o desenvolvimento e a construção de uma instrumentação alternativa a equipamentos disponíveis no mercado, como analisadores de rede e de impedância, que pudesse ser utilizada para a caracterização dielétrica de filmes biodegradáveis a base de gelatina. Foi utilizado o método de placas paralelas na determinação da parte real da permissividade conhecida como permissividade relativa ou constante dielétrica (ε\'). O circuito utilizado para a instrumentação foi um oscilador astável com funcionamento baseado no amplificador operacional (741) chaveado pela carga de um capacitor de placas paralelas cujo dielétrico foi uma amostra de filme biodegradável. A partir dos valores da frequência de oscilação e geometria do capacitor, foi possível calcular a capacitância de cada amostra e, consequentemente obter os valores da permissividade relativa do filme, usando relações básicas bem estabelecidas. Os filmes de gelatina foram produzidos pela técnica de casting sendo utilizados como plastificantes o glicerol (G), o sorbitol (S) e suas misturas, na proporção (G:S) de 30:70, 50:50 e 70:30. Os filmes foram caracterizados quanto à umidade e cristalinidade. A permissividade relativa (ε\') dos filmes, determinada a temperatura ambiente, foi avaliada em função da frequência (5 a 50 kHz), tempo de armazenamento, do teor de umidade e tipo de plastificante. A instrumentação projetada e construída foi capaz de medir com precisão a permissividade relativa das amostras, sendo que essa propriedade diminuiu com o aumento da frequência para todos os filmes. Mantendo-se a frequência constante, não houve variação de ε\' para os filmes de gelatina, independente do plastificante, ao longo de um mês de armazenamento a 24 ± 3 °C. O efeito da umidade foi observado em frequências menores que 25 kHz, sendo que quanto maior o teor de umidade maior a permissividade relativa. O efeito do tipo de plastificante na permissividade relativa dos filmes foi observado a baixas frequências (5 kHz) e filmes plastificados com sorbitol apresentaram maiores valores de ε\'. Os filmes plastificados com maior teor de umidade apresentaram menor cristalinidade, portanto maior mobilidade molecular e consequentemente maior a permissividade relativa.
Resumo:
This paper shows the results of an experimental analysis on the bell tower of “Chiesa della Maddalena” (Mola di Bari, Italy), to better understand the structural behavior of slender masonry structures. The research aims to calibrate a numerical model by means of the Operational Modal Analysis (OMA) method. In this way realistic conclusions about the dynamic behavior of the structure are obtained. The choice of using an OMA derives from the necessity to know the modal parameters of a structure with a non-destructive testing, especially in case of cultural-historical value structures. Therefore by means of an easy and accurate process, it is possible to acquire in-situ environmental vibrations. The data collected are very important to estimate the mode shapes, the natural frequencies and the damping ratios of the structure. To analyze the data obtained from the monitoring, the Peak Picking method has been applied to the Fast Fourier Transforms (FFT) of the signals in order to identify the values of the effective natural frequencies and damping factors of the structure. The main frequencies and the damping ratios have been determined from measurements at some relevant locations. The responses have been then extrapolated and extended to the entire tower through a 3-D Finite Element Model. In this way, knowing the modes of vibration, it has been possible to understand the overall dynamic behavior of the structure.