849 resultados para Operação cut-off


Relevância:

80.00% 80.00%

Publicador:

Resumo:

Nanoindentation has become a common technique for measuring the hardness and elastic-plastic properties of materials, including coatings and thin films. In recent years, different nanoindenter instruments have been commercialised and used for this purpose. Each instrument is equipped with its own analysis software for the derivation of the hardness and reduced Young's modulus from the raw data. These data are mostly analysed through the Oliver and Pharr method. In all cases, the calibration of compliance and area function is mandatory. The present work illustrates and describes a calibration procedure and an approach to raw data analysis carried out for six different nanoindentation instruments through several round-robin experiments. Three different indenters were used, Berkovich, cube corner, spherical, and three standardised reference samples were chosen, hard fused quartz, soft polycarbonate, and sapphire. It was clearly shown that the use of these common procedures consistently limited the hardness and reduced the Young's modulus data spread compared to the same measurements performed using instrument-specific procedures. The following recommendations for nanoindentation calibration must be followed: (a) use only sharp indenters, (b) set an upper cut-off value for the penetration depth below which measurements must be considered unreliable, (c) perform nanoindentation measurements with limited thermal drift, (d) ensure that the load-displacement curves are as smooth as possible, (e) perform stiffness measurements specific to each instrument/indenter couple, (f) use Fq and Sa as calibration reference samples for stiffness and area function determination, (g) use a function, rather than a single value, for the stiffness and (h) adopt a unique protocol and software for raw data analysis in order to limit the data spread related to the instruments (i.e. the level of drift or noise, defects of a given probe) and to make the H and E r data intercomparable. © 2011 Elsevier Ltd.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Purpose: To investigate whether eyes with diabetic macular edema (DME) and central retinal thickness (CRT) >400 μm had better visual and anatomical outcomes compared to eyes with a CRT <400 μm when treated with intravitreal bevacizumab in a real-world setting. Patients and methods: Patients undergoing intravitreal bevacizumab therapy for DME were identified from the departmental database of a tertiary referral unit. Following the initial injection, a retreatment was performed for any persistent macular edema, unless there had been no previous response to repeated doses. Recorded parameters included visual acuity, CRT on optical coherence tomography (spectral domain optical coherence tomography [SD-OCT]), and SD-OCT characteristics. Comparisons were made between data at baseline and 12 months after the first injection, and differences were tested for statistical significance using the Student's t-test. Results: In all, 175 eyes of 142 patients were analyzed. Patients in group 2 (CRT >400 μm) had significantly more injections than group 1 (CRT <400 μm) (4.0 versus 3.3; P=0.003). Both groups had similar numbers of eyes with preexisting epiretinal membrane and/or vitreomacular traction at baseline. The reduction in CRT was significantly greater in group 2 when compared to group 1 (P<0.0001). In terms of visual gain between baseline and month 12, each gained significantly by a mean of 0.12 logarithm of the minimum angle of resolution units (P=0.0001), but there was no difference between groups 1 and 2 (P=0.99). Conclusion: These results do not support a 400 μm baseline CRT cut-off for treating DME with bevacizumab, in contrast to published data on ranibizumab. Our results also indicate that patients with a thicker CRT require more bevacizumab injections, making treatment less cost-effective for these patients. Our results could be used by practitioners to support the use of bevacizumab in DME without applying a CRT cut-off. © 2014 Mushtaq et al.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

MSC 2010: 44A20, 33C60, 44A10, 26A33, 33C20, 85A99

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Diabetes mellitus (DM) is a metabolic disorder which is characterised by hyperglycaemia resulting from defects in insulin secretion, insulin action or both. The long-term specific effects of DM include the development of retinopathy, nephropathy and neuropathy. Cardiac disease, peripheral arterial and cerebrovascular disease are also known to be linked with DM. Type 1 diabetes mellitus (T1DM) accounts for approximately 10% of all individuals with DM, and insulin therapy is the only available treatment. Type 2 diabetes mellitus (T2DM) accounts for 90% of all individuals with DM. Diet, exercise, oral hypoglycaemic agents and occasionally exogenous insulin are used to manage T2DM. The diagnosis of DM is made where the glycated haemoglobin (HbA1c) percentage is greater than 6.5%. Pattern-reversal visual evoked potential (PVEP) testing is an objective means of evaluating impulse conduction along the central nervous pathways. Increased peak time of the visual P100 waveform is an expression of structural damage at the level of myelinated optic nerve fibres. This was an observational cross sectional study. The participants were grouped into two phases. Phase 1, the control group, consisted of 30 healthy non-diabetic participants. Phase 2 comprised of 104 diabetic participants of whom 52 had an HbA1c greater than 10% (poorly controlled DM) and 52 whose HbA1c was 10% and less (moderately controlled DM). The aim of this study was to firstly observe the possible association between glycated haemoglobin levels and P100 peak time of pattern-reversal visual evoked potentials (PVEPs) in DM. Secondly, to assess whether the central nervous system (CNS) and in particular visual function is affected by type and/or duration of DM. The cut-off values to define P100 peak time delay was calculated as the mean P100 peak time plus 2.5 X standard deviations as measured for the non-diabetic control group, and were 110.64 ms for the right eye. The proportion of delayed P100 peak time amounted to 38.5% for both diabetic groups, thus the poorly controlled group (HbA1c > 10%) did not pose an increased risk for delayed P100 peak time, relative to the moderately controlled group (HbA1c ≤ 10%). The P100 PVEP results for this study, do however, reflect significant delay (p < 0.001) of the DM group as compared to the non-diabetic group; thus, subclincal neuropathy of the CNS occurs in 38.5% of cases. The duration of DM and type of DM had no influence on the P100 peak time measurements.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Throughout the Biscayne Bay watershed, existing coastal wetland communities have been cut off from sheet flow for decades. With the expectation that reconnection of these wetlands to upstream water sources would alter existing hydrologic conditions and recreate a more natural sheet flow to Biscayne National Park, a demonstration project on freshwater rediversion was undertaken. The objectives of the project were to document the effects of freshwater diversion on: (a) swamp and nearshore water chemistry and hydrology; (b) soil development processes; (c) macrophyte and benthic algal community composition, structure and production; (d) abundance of epiphytic and epibenthic invertebrates; (e) zonation, production, and phenology of primary producers in the nearshore environment, and (f) exchanges of nutrients and particulates between nearshore and mangrove ecosystems.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The purpose of this study was to test 3 hypotheses: (a) that late Miocene to early Pliocene constriction and complete closure of the Central American Seaway (CAS), connecting tropical Atlantic and East Equatorial Pacific (EEP) oceans, caused decreased productivity in the Caribbean, due to reduced coastal upwelling and an end to the connection with high-productivity Pacific waters, (b) reduced paleoproductivity resulted in decreased diversity in the Caribbean and, (c) this decreased availability of food (reduced paleoproductivity) was responsible for larger mean test size in the three most common benthic foraminiferal species Epistominella exigua, Oridorsalis umbonatus and Globocassidulina subglobosa. ^ These are tested by applying correlation analysis to 7 groups of paleoceanographic proxies, 3 indices of diversity measures and mean test size data from the Caribbean Ocean Drilling Project Site 999, to 47 core samples for the interval between 8.3-2.5 Ma. Results are compared with published Caribbean and Pacific deep-sea records. ^ The Caribbean, between 8.3-7.9 Ma, experienced reduced current velocity and lower ventilation of bottom waters. Thereafter, until 4.2 Ma, the seasonality of phytodetritus input increased and ventilation further reduced. From 4.2-2.5 Ma, paleoproductivity decreased, current velocity reduced, ventilation improved, and the seasonality of phytodetrital input decreased dramatically. The benthic foraminiferal diversity followed the same trend as paleoproductivity. Individual correlation analysis between mean test size of benthic foraminiferal species Epistominella exigua, Oridorsalis umbonatus and Globocassidulina subglobosa and paleoceanographic proxies yielded a positive and significant relationship with paleoproductivity. However, a combined datasets of all 3 species yielded a negative and significant relationship with species abundance. ^ Thus, the study concludes that (a) the gradual closure of the CAS led Caribbean diversity and paleoproductivity to decrease abruptly at 7.9 Ma, when the nutrient-rich Pacific deep waters were cut off, and then, again with the complete closure of the seaway at 4.2 Ma, (b) diversity and paleoproductivity are positively correlated in the Caribbean and (c) that the availability of food is an overriding factor that influences mean test size; lower availability of food and decreased abundance leads to larger test size. ^

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Airborne Light Detection and Ranging (LIDAR) technology has become the primary method to derive high-resolution Digital Terrain Models (DTMs), which are essential for studying Earth's surface processes, such as flooding and landslides. The critical step in generating a DTM is to separate ground and non-ground measurements in a voluminous point LIDAR dataset, using a filter, because the DTM is created by interpolating ground points. As one of widely used filtering methods, the progressive morphological (PM) filter has the advantages of classifying the LIDAR data at the point level, a linear computational complexity, and preserving the geometric shapes of terrain features. The filter works well in an urban setting with a gentle slope and a mixture of vegetation and buildings. However, the PM filter often removes ground measurements incorrectly at the topographic high area, along with large sizes of non-ground objects, because it uses a constant threshold slope, resulting in "cut-off" errors. A novel cluster analysis method was developed in this study and incorporated into the PM filter to prevent the removal of the ground measurements at topographic highs. Furthermore, to obtain the optimal filtering results for an area with undulating terrain, a trend analysis method was developed to adaptively estimate the slope-related thresholds of the PM filter based on changes of topographic slopes and the characteristics of non-terrain objects. The comparison of the PM and generalized adaptive PM (GAPM) filters for selected study areas indicates that the GAPM filter preserves the most "cut-off" points removed incorrectly by the PM filter. The application of the GAPM filter to seven ISPRS benchmark datasets shows that the GAPM filter reduces the filtering error by 20% on average, compared with the method used by the popular commercial software TerraScan. The combination of the cluster method, adaptive trend analysis, and the PM filter allows users without much experience in processing LIDAR data to effectively and efficiently identify ground measurements for the complex terrains in a large LIDAR data set. The GAPM filter is highly automatic and requires little human input. Therefore, it can significantly reduce the effort of manually processing voluminous LIDAR measurements.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Many coastal wetland communities of south Florida have been cut off from freshwater sheet flow for decades and are migrating landward due to salt-water encroachment. A paleoecological study using mollusks was conducted to assess the rates and effects of salt-water encroachment due to freshwater diversion and sea level rise on coastal wetland basins in Biscayne National Park. Modem mollusk distributions taken from 226 surface sites were used to determine local habitat affinities which were applied to infer past environments from mollusk distributions found in soil cores. Mollusks species compositions were found to be strongly correlated to habitat and salinity, providing reliable predictions. Wetland soils were cored to bedrock at 36locations. Mollusks were abundant throughout the cores and 15 of the 20 most abundant taxa served as bioindicators of salinity and habitat. Historic accounts coupled with mollusk based inference models indicate (1) increasing salinity levels along the coast and encroaching into the interior with mangroves communities currently migrating westward, (2) replacement of a mixed graminoid-mangrove zone by a dense monoculture of dwarf mangroves, and (3) a confinement of freshwater and freshwater graminoid marsh to landward areas between urban developments and drainage canals.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Aim: to determine cut off points for The Homeostatic Model Assessment Index 1 and 2 (HOMA-1 and HOMA-2) for identifying insulin resistance and metabolic syndrome among a Cuban-American population. Study Design: Cross sectional. Place and Duration of Study: Florida International University, Robert Stempel School of Public Health and Social Work, Department of Dietetics and Nutrition, Miami, FL from July 2010 to December 2011. Methodology: Subjects without diabetes residing in South Florida were enrolled (N=146, aged 37 to 83 years). The HOMA1-IR and HOMA2-IR 90th percentile in the healthy group (n=75) was used as the cut-off point for insulin resistance. A ROC curve was constructed to determine the cut-off point for metabolic syndrome. Results: HOMA1-IR was associated with BMI, central obesity, and triglycerides (P3.95 and >2.20 and for metabolic syndrome were >2.98 (63.4% sensitivity and 73.3% specificity) and >1.55 (60.6% sensitivity and 66.7% specificity), respectively. Conclusion: HOMA cut-off points may be used as a screening tool to identify insulin resistance and metabolic syndrome among Cuban-Americans living in South Florida.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Objective: To evaluate in vitro the surface roughness and bacterial adhesion of nanoparticle composites, after being subjected to different finishing and polishing systems. Materials and Methods: 66 specimens were prepared, and 30 with Filtek Z350 XT (3M ESPE, USA) and 30 with the resin IPS Empress Direct (Ivoclar Vivadent, USA), divided into 6 groups (n = 10 ). Six specimens were prepared for analysis in scanning electron microscopy (SEM) .Each kind of resin was subjected to finishing and polishing systems: Sof-Lex Pop-On discs (3M ESPE, USA) and AstropolTM system (Ivoclar Vivadent , USA), featuring the experimental group. The control group did not undergo any kind of finishing and polishing technique. The average roughness (Ra) in both groups was measured using a roughness in the setting of 0.25 mm (cut off) and surface images obtained with photomicrographs taken with a scanning electron microscope (SEM) magnified 500 times. Bacterial adherence was evaluated by determining the absorbance (OD) of the suspension of adhered cells by spectrophotometer at 570 nm. The results were submitted for analyzed with 2-way ANOVA at α=.05 and Tukey multiple comparison tests. Results: Statistically significant differences were found between the groups in terms of roughness and bacterial adhesion. Filtek Z350 XT for resin were no differences between the tested finishing and polishing systems, where the system of lowest surface roughness was the Sof-Lex Pop-On. To the resin IPS Empress Direct, the finishing and polishing system Astropol, had lower results of surface roughness. As for bacterial adhesion, the lowest optical density value for Filtek Z350 XT was for the group that used the finishing and polishing system Sof-Lex Pop-On and the resin IPS Empress Direct the group that used the Astropol system. In addition, there was a positive correlation between surface roughness and bacterial adhesion on polished surfaces (r = 0.612) Conclusions: surface roughness and bacterial adhesion are closely related. The finishing and polishing Sof-Lex Pop-On system is more suitable for nanoparticulate Filtek Z350 XT and the finishing and polishing system Astropol for resin nanohíbrida IPS Empress Direct.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Background: Obstructive airway diseases (OADs) are among the leading causes of morbidity and mortality worldwide. Shortness of breath (SOB) is the main symptom associated with OADs. International guidelines from the Global Initiative for Chronic Lung Disease (GOLD) and the Global Initiative for Asthma (GINA) have recommended spirometry as an indispensable tool for the diagnosis of asthma and chronic obstructive pulmonary diseases (COPD), but spirometry is rarely used in family practice. Simple and reliable diagnostic tools are necessary for screening community patients with onset of OADs for timely management. Purpose: This thesis examined screening utility of the PiKo-6 forced expiratory volume in one second (pFEV₁) , in six second (pFEV₆), and the pRatio ( pFEV₁/pFEV₆) in SOB patients for OADs in community pharmacy settings. FEV₆ has recently been suggested an excellent surrogate for Forced Vital Capacity (FVC), which requires maximum exhalation of the lungs. Methods: Patients with SOB symptoms who were prescribed pulmonary inhalers, by their family physicians, were recruited via community pharmacies. Trained pharmacists collected two PiKo-6 tests to assess the repeatability of the PiKo-6 device. All patients performed laboratory spirometry ( FEV₁, FVC and FEV₁/FVC) to obtain physician diagnosis of their OADs. The results of the PiKo-6 spirometer and laboratory spirometer were compared. In addition, the PiKo-6 pRatio and laboratory FEV₁/FVC were assessed against physician diagnosed COPD. Results: Sixty three patients volunteered to perform the PiKo-6 spirometry. Of these, 52.4 % were men (age 53.9 ± 15.3 years; BMI 31.9 ± 7.40 kg/m2). Repeated testing with pFEV₁, pFEV6 and pRatio correlated significantly (within correlation, r = 0.835, p-Value≤ 0.05 ; 0.872, p- Value≤ 0.05; and 0.664, p-Value≤ 0.05). In addition, pFEV₁, pFEV6 and pRatio correlated significantly with FEV₁, FVC and FEV₁/FVC, respectively (between correlation = 0.630, p- Value≤ 0.05 ; 0.660, p-Value≤ 0.05 and 0.580, p-Value≤ 0.05). The cut-off value corresponding to the greatest sum of sensitivity and specificity of pRatio for physician-diagnosed COPD was <0.80, the sensitivity and specificity were 84 % and 50%, respectively. Conclusions The portable PiKo-6 correlates moderately well with the standard spirometry, when delivered by community pharmacists to patients with OADs. The PiKo-6 spirometer may play a role in screening patients suspected of having an OAD in community pharmacies that may benefit from early physician diagnosis and appropriate management.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The first Air Chemistry Observatory at the German Antarctic station Georg von Neumayer (GvN) was operated for 10 years from 1982 to 1991. The focus of the established observational programme was on characterizing the physical properties and chemical composition of the aerosol, as well as on monitoring the changing trace gas composition of the background atmosphere, especially concerning greenhouse gases. The observatory was designed by the Institut für Umweltphysik, University of Heidelberg (UHEIIUP). The experiments were installed inside the bivouac lodge, mounted on a sledge and put upon a snow hill to prevent snow accumulation during blizzards. All experiments were under daily control and daily performance protocols were documented. A ventilated stainless steel inlet stack (total height about 3-4 m above the snow surface) with a 50% aerodynamic cut-off diameter around 7-10 µm at wind velocities between 4-10 m/s supplied all experiments with ambient air. Contamination free sampling was realized by several means: (i) The Air Chemistry Observatory was situated in a clean air area about 1500 m south of GvN. Due to the fact that northern wind directions are very rare, contamination from the base can be excluded for most of the time. (ii) The power supply (20 kW) is provided by a cable from the main station, thus no fuel-driven generator is operated in the very vicinity. (iii) Contamination-free sampling is controlled by the permanently recorded wind velocity, wind direction and by condensation particle concentration. Contamination was indicated if one of the following criteria were given: Wind direction within a 330°-30° sector, wind velocity <2.2 m/s or >17.5 m/s, or condensation particle concentrations >2500/cm**3 during summer, >800/cm**3 during spring/autumn and >400/cm**3 during winter. If one or a definable combination of these criteria were given, high volume aerosol sampling and part of the trace gas sampling were interrupted. Starting at 1982 through 1991-01-14 surface ozone was measured with an electrochemical concentration cell (ECC). Surface ozone mixing ratio are given in ppbv = parts per 10**9 by volume. The averaging time corresponds to the given time intervals in the data sheet. The accuracy of the values are better than ±1 ppbv and the detection limit is around 1.0 ppbv. Aerosols were sampled on two Whatman 541 cellulose filters in series and analyzed by ion chromatography at the UHEI-IUP. Generally, the sampling period was seven days but could be up to two weeks on occasion. The air flow was around 100 m**3/h and typically 10000-20000 m**3 of ambient air was forced through the filters for one sample. Concentration values are given in nanogram (ng) per 1 m**3 air at standard pressure and temperature (1013 mbar, 273.16 K). Uncertainties of the values were approximately ±10% to ±15% for the main components MSA, chloride, nitrate, sulfate and sodium, and between ±20% and ±30% for the minor species bromide, ammonium, potassium, magnesium and calcium.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The chemical composition of surface associated metabolites of two Fucus species (Fucus vesiculosus and Fucus serratus) was analysed by means of gas chromatography-mass spectrometry (GC-MS) to describe temporal patterns in chemical surface composition. Method: The two perennial brown macroalgae F. vesiculosus and F. serratus were sampled monthly at Bülk, outer Kiel Fjord, Germany (54°27'21 N / 10°11'57 E) over an entire year (August 2012 - July 2013). Per month and species six non-fertile Fucus individuals were collected from mixed stands at a depth of 0.5 m under mid water level. For surface extraction approx. 50 g of the upper 5-10 cm apical thalli tips were cut off per species. The surface extraction of Fucus was performed according to the protocol of de Nys and co-workers (1998) with minor modifications (see Rickert et al. 2015). GC/EI-MS measurements were performed with a Waters GCT premier (Waters, Manchester, UK) coupled to an Agilent 6890N GC equipped with a DB-5 ms 30 m column (0.25 mm internal diameter, 0.25 mM film thickness, Agilent, USA). The inlet temperature was maintained at 250°C and samples were injected in split 10 mode. He carrier gas flow was adjusted to 1 ml min-1. Alkanes were used for referencing of retention times. For further details (GC-MS sample preparation and analysis) see the related publication (Rickert et al. submitted to PLOS ONE).

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Two years of harmonized aerosol number size distribution data from 24 European field monitoring sites have been analysed. The results give a comprehensive overview of the European near surface aerosol particle number concentrations and number size distributions between 30 and 500 nm of dry particle diameter. Spatial and temporal distribution of aerosols in the particle sizes most important for climate applications are presented. We also analyse the annual, weekly and diurnal cycles of the aerosol number concentrations, provide log-normal fitting parameters for median number size distributions, and give guidance notes for data users. Emphasis is placed on the usability of results within the aerosol modelling community. We also show that the aerosol number concentrations of Aitken and accumulation mode particles (with 100 nm dry diameter as a cut-off between modes) are related, although there is significant variation in the ratios of the modal number concentrations. Different aerosol and station types are distinguished from this data and this methodology has potential for further categorization of stations aerosol number size distribution types. The European submicron aerosol was divided into characteristic types: Central European aerosol, characterized by single mode median size distributions, unimodal number concentration histograms and low variability in CCN-sized aerosol number concentrations; Nordic aerosol with low number concentrations, although showing pronounced seasonal variation of especially Aitken mode particles; Mountain sites (altitude over 1000 m a.s.l.) with a strong seasonal cycle in aerosol number concentrations, high variability, and very low median number concentrations. Southern and Western European regions had fewer stations, which decreases the regional coverage of these results. Aerosol number concentrations over the Britain and Ireland had very high variance and there are indications of mixed air masses from several source regions; the Mediterranean aerosol exhibit high seasonality, and a strong accumulation mode in the summer. The greatest concentrations were observed at the Ispra station in Northern Italy with high accumulation mode number concentrations in the winter. The aerosol number concentrations at the Arctic station Zeppelin in Ny-Ålesund in Svalbard have also a strong seasonal cycle, with greater concentrations of accumulation mode particles in winter, and dominating summer Aitken mode indicating more recently formed particles. Observed particles did not show any statistically significant regional work-week or weekday related variation in number concentrations studied. Analysis products are made for open-access to the research community, available in a freely accessible internet site. The results give to the modelling community a reliable, easy-to-use and freely available comparison dataset of aerosol size distributions.