842 resultados para Opening Day Ceremony


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: To evaluate whether intracytoplasmic morphologically selected sperm injection (IMSI) could influence early paternal effects by observing embryo quality at day 2.Study design: The study included 30 couples with at least one of the following criteria: male factor infertility, at least 2 previous failures of implantation or previous miscarriages after IVF/ICSI. Sibling oocytes of each patient were randomly assigned to either the ICSI group or the IMSI group. For IMSI, spermatozoa were selected at 8400x magnification through an inverted microscope equipped with Nomarski differential interference contrast optics, Uplan Apo 100x oil/1.35 objective lens and variable zoom lens. For conventional ICSI, spermatozoa were selected at 400x magnification. An embryo was defined as top quality if there were four identical blastomeres on day 2 with no fragments or multinucleation of blastomeres. Data were analysed using the Wilcoxon and chi-squared tests. The significance level was set at P < 0.05. The variables were analysed in relation to the general population and the subpopulations with or without male factor.Results: A total of 331 MII oocytes (30 oocyte retrievals) were selected and injected by the ICSI (n: 172) or IMSI (n: 159) procedure. For IMSI, only spermatozoa classified as morphologically normal at high magnification were used. No differences (P > 0.05) in fertilisation rate (ICSI: 70.9%; IMSI: 70.4%), early embryo cleavage rate (ICSI: 66.9%; IMSI: 60.4%) or cleavage rate (ICSI: 99.2%; IMSI: 99.1%) were observed. on day 2, as compared to ICSI, IMSI provided a similar proportion of top quality embryos (ICSI: 57.8%; IMSI: 52.2%; P > 0.05). These results were not influenced by the presence or absence of male factor.Conclusion: In terms of embryo quality at day 2, IMSI had the same performance as conventional ICSI. However, we cannot exclude the possibility that IMSI effects occur only as a positive later paternal effect. (C) 2010 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Vacas da raça Holandesas em lactação (n=158) aos 213±112 dias de lactação e produção de 26±9kg leite/dia, foram aleatoriamente distribuídas em três grupos: controle (GC, n=52, salina); GnRH (GG, n=55, 100mcg de gonadorelina); e hCG (GH, n=51, 2500UI de hCG) aplicado no dia 5 após a inseminação artificial (IA). A temperatura retal foi verificada no momento da IA, e as amostras de sangue coletadas nos dias 5, 7 e 12 após a IA. A concepção foi determinada entre os dias 42 e 49 após IA. As concentrações séricas de progesterona (P4 - ng/ml, média±EPM) para GC, GG, e GH foram, respectivamente: no dia 5: 2,7±0,4, 2,5±0,4 e 3,2±0,4; no dia 7: 4,8±0,4, 4,2±0,4 e 5,7±0,5; e no dia 12 após a IA: 5,2±0,4, 6,9±0,4 e 8,5±0,5. O aumento proporcional na concentração sérica de P4 entre os dias 5 e 7 após IA (GC: 178%, GG: 168%, e GH: 178%) sugere que os tratamentos não induziram efeito luteotrópico no corpo lúteo (CL) existente. O aumento na P4 sérica entre os dias 7 e 12 nos animais tratados com GnRH ou hCG (GG: 164% e GH: 149%, P<0,01) em relação aos animais controle (GC: 18%, P=0,31), sugere a indução de novo CL. Os tratamentos com GnRH ou hCG aumentaram as taxas de concepção nas vacas com temperatura retal abaixo de 39,7°C (GC: 10,1%, n=26; GG: 36,8%, n=27 e GH: 32,8%, n=21), mas não em vacas com temperatura retal acima de 39,7°C (15,2% n=26; 17,8%, n=28 e 24,4%, n=30). Os resultados sugerem que a alta temperatura corporal pode mascarar os efeitos positivos do tratamento com GnRH ou hCG no dia 5 após a IA, na concepção.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Three experiments were carried out to analyze the performance and egg quality of Japanese quails throughout the day when submitted to different lighting programs. In each experiment, birds were submitted to a period of 28 days for adaptation to the lighting program. During the following three days, each day - from 7 am to 7 pm or 9 pm - was divided into six or seven periods of two hours each, and the remaining hours corresponded to another single period. All birds were submitted to the same management practices, and received water and feed ad libitum. The experimental diet was formulated according to NRC (1994) standards. It was observed lower feed intake in the period of 9 pm to 7 am, and a higher incidence of lay from 3 pm to 7 pm, as opposite to hens, which peak of egg laying occurs during the morning. Some controversial results were found among experiments as to eggshell quality during the different periods of the day. Variation on the lighting program had little influence on the other performance and egg quality parameters.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The present study aimed at reporting a clinical and surgical case of bilateral coronoidectomy, using an intraoral approach. The patient is a 26-year-old man, who sought attendance complaining of a gradual reduction of his oral opening in the past 3 years; however, he had an aggravation in the last 2 months. After clinical examination and imaging evaluation, the diagnosis of coronoid process hyperplasia was confirmed, and the surgical treatment was proposed. Under general anesthesia, with nasotracheal intubation guided by a nasofiberendoscope, using an intraoral approach, the bilateral coronoidectomy was performed. In the immediate postoperative period, an increase of the buccal opening measured 29 mm, representing an enhancement of 11 mm, and in the 30th postoperative day, it measured 31.12 mm. During the clinical follow-up period, a reestablishment of the mandibular movements was observed. Therefore, coronoidectomy by an intraoral approach and the physiotherapy performed in the postoperative period were efficient procedures.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this in vivo study was to evaluate the biocompatibility of three current bonding agents and calcium hydroxide cement. Sixty polyethylene tubes filled with the following materials: Group 1: Prime & Bond NT (PB - Dentsply, US; Group 2: Bond 1 (BO - Jeneric/Pentron, US); Group 3: Optibond Solo (OP - Kerr, US); and Group 4 (control): calcium hydroxide cement - Dycal (CH - Dentsply, US) were implanted into the connective tissue of 30 rats. After 15, 30 and 60 days, the implants were excised and the animals sacrificed. The biopsies were immersed in Karnovsky (pH, 7.2) fixative solution for 48 hours, and processed using routine histological technique. Six-micron-thick sections were cut and stained with hematoxilin and eosin and Masson's trichome technique. Microscopic evaluation was used to compare the connective tissue reactions caused by the experimental and control materials adjacent to the tube opening. At 15 days, the experimental and control materials triggered a moderate to intense inflammatory response which gave rise to a thick capsule adjacent to the tube opening. With time, the inflammatory reaction decreased. At 60 days, the connective tissue adjacent to the bonding agents exhibited a persistent inflammatory response mediated by macrophages and giant cells which were engulfing displaced resin components. on the other hand, for the control group (calcium hydroxide) no inflammatory response associated with a thin capsule adjacent to the material was observed even at the 30-day period. The hard-setting calcium hydroxide cement allowed complete healing and was considered more biocompatible than the bonding agents.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Neste artigo é descrito o caso clínico de um paciente adulto, sem crescimento, com má oclusão de Classe II, divisão 2, tratado com um splint maxilar modificado. Foi exercida força extra-bucal com direção de tração parietal com força de 400 gramas, com uso diário de 14 horas durante 1 ano. Com este aparelho removível corrigiu-se completamente a relação de Classe II dos molares e pré-molares, levando estes dentes à oclusão normal, não havendo extrusão dentária, mantendo constante o plano mandibular. Após a correção dos dentes posteriores com o splint maxilar modificado, utilizou-se aparelhagem fixa convencional para corrigir as inclinações dos dentes anteriores e finalizar o caso.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)