997 resultados para Nickel-selective sensor


Relevância:

20.00% 20.00%

Publicador:

Resumo:

We consider a scenario where the communication nodes in a sensor network have limited energy, and the objective is to maximize the aggregate bits transported from sources to respective destinations before network partition due to node deaths. This performance metric is novel, and captures the useful information that a network can provide over its lifetime. The optimization problem that results from our approach is nonlinear; however, we show that it can be converted to a Multicommodity Flow (MCF) problem that yields the optimal value of the metric. Subsequently, we compare the performance of a practical routing strategy, based on Node Disjoint Paths (NDPs), with the ideal corresponding to the MCF formulation. Our results indicate that the performance of NDP-based routing is within 7.5% of the optimal.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Design and development of a piezoelectric polyvinylidene fluoride (PVDF) thin film based nasal sensor to monitor human respiration pattern (RP) from each nostril simultaneously is presented in this paper. Thin film based PVDF nasal sensor is designed in a cantilever beam configuration. Two cantilevers are mounted on a spectacle frame in such a way that the air flow from each nostril impinges on this sensor causing bending of the cantilever beams. Voltage signal produced due to air flow induced dynamic piezoelectric effect produce a respective RP. A group of 23 healthy awake human subjects are studied. The RP in terms of respiratory rate (RR) and Respiratory air-flow changes/alterations obtained from the developed PVDF nasal sensor are compared with RP obtained from respiratory inductance plethysmograph (RIP) device. The mean RR of the developed nasal sensor (19.65 +/- A 4.1) and the RIP (19.57 +/- A 4.1) are found to be almost same (difference not significant, p > 0.05) with the correlation coefficient 0.96, p < 0.0001. It was observed that any change/alterations in the pattern of RIP is followed by same amount of change/alterations in the pattern of PVDF nasal sensor with k = 0.815 indicating strong agreement between the PVDF nasal sensor and RIP respiratory air-flow pattern. The developed sensor is simple in design, non-invasive, patient friendly and hence shows promising routine clinical usage. The preliminary result shows that this new method can have various applications in respiratory monitoring and diagnosis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A power scalable receiver architecture is presented for low data rate Wireless Sensor Network (WSN) applications in 130nm RF-CMOS technology. Power scalable receiver is motivated by the ability to leverage lower run-time performance requirement to save power. The proposed receiver is able to switch power settings based on available signal and interference levels while maintaining requisite BER. The Low-IF receiver consists of Variable Noise and Linearity LNA, IQ Mixers, VGA, Variable Order Complex Bandpass Filter and Variable Gain and Bandwidth Amplifier (VGBWA) capable of driving variable sampling rate ADC. Various blocks have independent power scaling controls depending on their noise, gain and interference rejection (IR) requirements. The receiver is designed for constant envelope QPSK-type modulation with 2.4GHz RF input, 3MHz IF and 2MHz bandwidth. The chip operates at 1V Vdd with current scalable from 4.5mA to 1.3mA and chip area of 0.65mm2.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A low cost, reagent free, Escherichia coli sensor is demonstrated with graphene, on transparent flexible acetate substrate. Graphene is grown on 100 mu m thick Cu foil, using CVD process and subsequently transferred on to a flexible acetate substrate. Gold electrodes are deposited on graphene to form a two terminal, interdigitated capacitor structure. Impedance spectroscopy (10 Hz to 100 kHz) is performed to characterize the change in impedance, as a function of E. coli concentration on graphene surface. The residual methyl groups on graphene, resulting from the transfer process, act as binding sites for E. coli. It has been observed that the resistance of graphene decreases with increasing E. coli concentration. This is due to the increased hole doping induced by negatively charged E. coli. A sensitivity of 60% is achieved for an E. coli concentration of 4.5 x 10(7) cfu/ml. An equivalent RC model is proposed to explain the sensing mechanism. (C) 2013 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This work aims at providing an effective parking management system by reducing the drivers' searching time for vacant car-parking space, in turn improving the traffic flow in the car park areas. This is achieved by the use of Fiber Bragg Grating Sensor (FBG) sensor instrumentation in vehicle parking management system. Present work involves embedding an array of FBG sensors underground in the parking space, then determining the strain changes on the FBG sensor due to load applied by the vehicle parked in the parking space, occupancy of the parking space is determined. To validate the FBG sensor parking management system, three most common cases have been considered. This closed loop FBG parking management system can give real-time feed-back to space-guidance display board helping the driver in maneuvering the vehicle to the appropriate parking space. The proposed technique offers optimized usage of parking space for the various segments of cars and also facilitates in a conjoined automated billing system, as compared to conventional method of parking systems.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The detection of contaminated food in every stage of processing required new technology for fast identification and isolation of toxicity in food. Since effect of food contaminant are severe to human health, the need of pioneer technologies also increasing over last few decades. In the current study, MDA was prepared by hydrolysis of 1,1,3,3-tetramethoxypropane in HCl media and used in the electrochemical studies. The electrochemical sensor was fabricated with modified glassy carbon electrode with polyaniline. These sensors were used for detection of sodium salt of malonaldehyde and observed that a high sensitivity in the concentration range similar to 1 x 10(-1) M and 1 x 10(-2) M. Tafel plots show the variation of over potential from -1.73 V to -3.74 V up to 10(-5) mol/L indicating the lower limit of detection of the system. (C) 2013 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The magnetic properties of carbon nanotube encapsulated nickel nanowires (C. E. nanowires of diameter similar to 10 nm), and its comparison to other forms of Ni are carried out in this work. The saturation magnetization (M-s) and coercivity (H-c) for C. E. nanowires are 1.0 emu/g and 230 Oe. The temperature dependence of coercivity follows T-0.77 dependence indicating a superparamagnetic behavior. The field-cooled and zero-field-cooled plots indicate that the blocking temperature (T-B) similar to 300 K. These altered magnetic properties of C. E. nanowires are mainly due to the nanoscale confinement effect from carbon nanotube encapsulation. The shape and magnetic environment enhance the total magnetic anisotropy of C. E. nanowires by a factor of four.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Microbially induced selective flocculation of hematite from kaolinite has been demonstrated using Bacillus subtilis. Growth of bacterial cells in the presence of kaolinite resulted in enhanced production of extracellular proteins while that of hematite promoted significant secretion of exopolysaccharides. Bacterial cells were adapted to grow in the presence of the minerals and use of hematite-grown and kaolinite-grown cells and their metabolic products in the selective flocculation of hematite and dispersion of kaolinite illustrated. Bacterial cells and extracellular polysaccharides exhibited higher surface affinity towards hematite, rendering it hydrophilic; while significant protein adsorption enhanced surface hydrophobicity of kaolinite. Bacterial interaction with hematite and kaolinite resulted in significant surface chemical changes on the minerals. Due to higher surface affinity towards extracellular proteins, zeta potentials of kaolinite shifted in the positive direction, while those of hematite shifted in the negative direction due to higher adsorption of extracellular polysaccharides. Bacterial interaction promoted selective flocculation of only hematite, while kaolinite was efficiently dispersed. Mineral-specific stress proteins were generated on growing B. subtilis in the presence of kaolinite. Interfacial aspects of microbe-mineral interactions are illustrated to explain microbially-induced selective flocculation of hematite from kaolinite with relevance to clay and iron ore beneficiation. (C) 2013 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The selective flotation of sphalerite from a sphalerite-galena mineral mixture has been achieved using cells and extracellular secretions of Bacillus megaterium after adaptation to the chosen minerals. The extracellular secretions obtained after thermolysis of bacterial cells adapted to sphalerite yield the highest flotation recovery of sphalerite with a selectivity index value of 24.5, in comparison to the other cellular and extra-cellular bio-reagents studied. The protein profile for the unadapted and mineral-adapted cells has been found to differ distinctly, attesting to variation in the yield and nature of extra-cellular polymeric substances (EPS). The changes induced in the bacterial cell wall components after adaptation to sphalerite or galena with respect to the contents of phosphate, uronic acid and acetylated sugars of B. megaterium have been quantified. The role of the dissolved metal ions from the minerals as well as that of the constituents of extracellular secretions in modulating the surface charge of the bacterial cells as well as the minerals under study has been confirmed using various enzymatic treatments of the bacterial cells. It has been demonstrated that the induction of additional molecular weight protein fractions as well as the higher amount of extracellular proteins and phosphate secreted after adaptation to sphalerite vis-A-vis galena are contributory factors for the selective separation of sphalerite from galena. (C) 2013 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Carbon nanotubes (CNT) due to its multifunctional characteristics has been presented as a flame sensor by combining both radiation and chemical sensitivity. Chemical functionalization enhances the sensitivity of CNT sensor toward any chemical modifications that are induced by the flame. Response of the sensor is revealed to be dependent on the measurement direction (longitudinal and transverse) as well as the radiation intensity. A nonlinear relation between the sensitivity and its distance from the source is used to calibrate the intensity of the flame. The present method allows a simpler approach for the flame detection by utilizing a calibration scheme to operate at any particular bias current and tune its sensitivity with respect to any working distance at a particular bias current. (C) 2013 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Selective detection of nitro-aromatic compounds (NACs) at nanomolar concentration is achieved for the first time in multiple media including water, micelles or in organogels as well as using test strips. Mechanism of interaction of NACs with highly fluorescent p-phenylenevinylene-based molecules has been described as the electron transfer phenomenon from the electron-rich chromophoric probe to the electron deficient NACs. The selectivity in sensing is guided by the pK(a) of the probes as well as the NACs under consideration. TNP-induced selective gel-to-sol transition in THF medium is also observed through the reorganization of molecular self-assembly and the portable test trips are made successfully for rapid on-site detection purpose.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Autophagy is one of the major immune mechanisms engaged to clear intracellular infectious agents. However, several pathogens have evolved strategies to evade autophagy. Here, we demonstrated that Mycobacteria, Shigella, and Listeria but not Klebsiella, Staphylococcus, and Escherichia inhibit IFNG-induced autophagy in macrophages by evoking selective and robust activation of WNT and SHH pathways via MTOR. Utilization of gain- or loss-of-function analyses as well as mir155-null macrophages emphasized the role of MTOR-responsive epigenetic modifications in the induction of Mir155 and Mir31. Importantly, cellular levels of PP2A, a phosphatase, were regulated by Mir155 and Mir31 to fine-tune autophagy. Diminished expression of PP2A led to inhibition of GSK3B, thus facilitating the prolonged activation of WNT and SHH signaling pathways. Sustained WNT and SHH signaling effectuated the expression of anti-inflammatory lipoxygenases, which in tandem inhibited IFNG-induced JAK-STAT signaling and contributed to evasion of autophagy. Altogether, these results established a role for new host factors and inhibitory mechanisms employed by the pathogens to limit autophagy, which could be targeted for therapeutic interventions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Deviated nasal septum (DNS) is one of the major causes of nasal obstruction. Polyvinylidene fluoride (PVDF) nasal sensor is the new technique developed to assess the nasal obstruction caused by DNS. This study evaluates the PVDF nasal sensor measurements in comparison with PEAK nasal inspiratory flow (PNIF) measurements and visual analog scale (VAS) of nasal obstruction. Methods: Because of piezoelectric property, two PVDF nasal sensors provide output voltage signals corresponding to the right and left nostril when they are subjected to nasal airflow. The peak-to-peak amplitude of the voltage signal corresponding to nasal airflow was analyzed to assess the nasal obstruction. PVDF nasal sensor and PNIF were performed on 30 healthy subjects and 30 DNS patients. Receiver operating characteristic was used to analyze the DNS of these two methods. Results: Measurements of PVDF nasal sensor strongly correlated with findings of PNIF (r = 0.67; p < 0.01) in DNS patients. A significant difference (p < 0.001) was observed between PVDF nasal sensor measurements and PNIF measurements of the DNS and the control group. A cutoff between normal and pathological of 0.51 Vp-p for PVDF nasal sensor and 120 L/min for PNIF was calculated. No significant difference in terms of sensitivity of PVDF nasal sensor and PNIF (89.7% versus 82.6%) and specificity (80.5% versus 78.8%) was calculated. Conclusion: The result shows that PVDF measurements closely agree with PNIF findings. Developed PVDF nasal sensor is an objective method that is simple, inexpensive, fast, and portable for determining DNS in clinical practice.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A facile synthetic route for a new class of organoborane compounds (Mes)(2)B-arene-acacH and (Mes)(2)Barene-acacBF2 (Mes = mesityl and arene = C6H4 or C6Me4) is reported. The new dyads exhibit intriguing photophysical properties. A small structural change in spacer connecting the two chromophores leads to fine tuning of photophysical properties. The dyad containing 2,3,5,6-tetramethyl phenyl spacer acts as a selective ``turn-on'' chemodosimetric sensor for cyanide ion. Steric crowding around the boron centre significantly alters anion binding events. From NMR titration studies it is established that fluoride and cyanide follow different binding mechanisms which lead to intriguing optical properties in the reported probes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents the design technique that has been adopted for packaging of Polyvinylidene fluoride (PVDF) nasal sensor for biomedical applications. The PVDF film with the dimension of length 10mm, width 5mm and thickness 28 mu m was firmly adhered on one end of plastic base (8mmx5mmx30 mu m) in such a way that it forms a cantilever configuration leaving the other end free for deflection. Now with the leads attached on the surface of the PVDF film, the cantilever configuration becomes the PVDF nasal sensor. For mounting a PVDF nasal sensor, a special headphone was designed, that can fit most of the human head sizes. Two flexible strings are soldered on either side of the headphone. Two identical PVDF nasal sensors were then connected to either side of flexible string of the headphone in such a way that they are placed below the right and left nostrils respectively without disturbing the normal breathing. When a subject wares headphone along with PVDF nasal sensors, two voltage signals due to the piezoelectric property of the PVDF film were generated corresponding to his/her nasal airflow from right and left nostril. The entire design was made compact, so that PVDF nasal sensors along with headphone can be made portable. No special equipment or machines are needed for mounting the PVDF nasal sensors. The time required for packaging of PVDF nasal sensors was less and the approximate cost of the entire assembly (PVDF nasal sensors + headphone) was very nominal.