898 resultados para Multi Kidney Exchange Problem KEP
Resumo:
Spaceborne/airborne synthetic aperture radar (SAR) systems provide high resolution two-dimensional terrain imagery. The paper proposes a technique for combining multiple SAR images, acquired on flight paths slightly separated in the elevation direction, to generate high resolution three-dimensional imagery. The technique could be viewed as an extension to interferometric SAR (InSAR) in that it generates topographic imagery with an additional dimension of resolution. The 3-D multi-pass SAR imaging system is typically characterised by a relatively short ambiguity length in the elevation direction. To minimise the associated ambiguities we exploit the relative phase information within the set of images to track the terrain landscape. The SAR images are then coherently combined, via a nonuniform DFT, over a narrow (in elevation) volume centred on the 'dominant' terrain ground plane. The paper includes a detailed description of the technique, background theory, including achievable resolution, and the results of an experimental study.
Resumo:
In this paper we describe a distributed object oriented logic programming language in which an object is a collection of threads deductively accessing and updating a shared logic program. The key features of the language, such as static and dynamic object methods and multiple inheritance, are illustrated through a series of small examples. We show how we can implement object servers, allowing remote spawning of objects, which we can use as staging posts for mobile agents. We give as an example an information gathering mobile agent that can be queried about the information it has so far gathered whilst it is gathering new information. Finally we define a class of co-operative reasoning agents that can do resource bounded inference for full first order predicate logic, handling multiple queries and information updates concurrently. We believe that the combination of the concurrent OO and the LP programming paradigms produces a powerful tool for quickly implementing rational multi-agent applications on the internet.
Resumo:
Combinatorial optimization problems share an interesting property with spin glass systems in that their state spaces can exhibit ultrametric structure. We use sampling methods to analyse the error surfaces of feedforward multi-layer perceptron neural networks learning encoder problems. The third order statistics of these points of attraction are examined and found to be arranged in a highly ultrametric way. This is a unique result for a finite, continuous parameter space. The implications of this result are discussed.
Resumo:
The authors undertook this study to assess levels of cadmium exposure in the general population. Samples of lung, liver, and kidney were obtained from 61 cadavers (43 males, 18 females; 2-89 yr of age, mean age = 38.5 yr) who died from accidental causes and who were subject to postmortem examinations at the John Tonge Centre for Forensic Sciences, Queensland Health Scientific Services, Brisbane, Australia, in 1997 and 1998. Samples of bladder urine were also obtained from 22 cadavers. Tissue and urine samples were analyzed for cadmium, zinc, and copper with inductively coupled plasm (ICP) mass spectrometry. The overall mean values for cadmium in the lung, liver, and kidney cortex samples were 0.13, 0.95, and 15.45 mug/gm wet tissue weight. The average renal cadmium level in subjects with high lung-cadmium levels (n = 13) was 6 mug/gm wet tissue weight higher than that of similarly aged subjects who had medium lung-cadmium levels (n = 30). In females, the average level of cadmium in the liver was 74% greater than in males, and the average liver cadmium in females with high lung-cadmium levels was 100% higher than in males in the same age range who had the same high lung-cadmium levels. Renal cadmium accumulation tended to be greater in females than in males who were in the same age range and who had similar lung-cadmium levels, a result that suggested that there was a higher absorption rate of cadmium in females. The mean value for a urinary cadmium excretion of 2.30 mug/gm creatinine was found in a subset of samples that had a mean age of 39 yr and a renal cortex cadmium concentration of 18.6 mug/gm wet tissue weight. Urinary cadmium excretion rates were correlated more strongly with lung and kidney cadmium content than with age or liver cadmium levels. The results suggest that urinary cadmium excretion may be increased in smokers and could provide some estimate of body cadmium burdens in future Australian epidemiological studies.
Resumo:
Objective To describe the renal lesions in Bull Terrier polycystic kidney disease (BTPKD), to confirm that the renal cysts in BTPKD arise from the nephron or collecting tubule, an to identify lesions consistent with concurrent BTPKD and Bull Terrier hereditary nephritis (BTHN). Design Renal tissue from five Bull Terriers with BTPKD and eight control dogs was examined by light and transmission electron microscopy. Clinical data were collected from all dogs, and family history of BTPKD and BTHN for all Bull Terriers. Results In BTPKD the renal cysts were lined by epithelial cells of nephron or collecting duct origin that were usually squamous or cuboidal, with few organelles. They had normal junctional complexes, and basal laminae of varying thicknesses. Glomeruli with small, atrophic tufts and dilated Bowman's capsules, tubular loss and dilation, and interstitial inflammation and fibrosis were common. Whereas the lesions seen in BTHN by light microscope were nonspecific, the presence of characteristic ultrastructural glomerular basement membrane (GMB) lesions and a family history of this disease indicated concurrent BTHN was likely in three of five cases of BTPKD. Conclusion This paper provides evidence that renal cysts in BTPKD are of nephron or collecting duct origin. In addition, GBM lesions are described that strongly suggest that BTPKD and BTHN may occur simultaneously.
Resumo:
The development of secondary arm lymphoedema after the removal of axillary lymph nodes remains a potential problem for women with breast cancer. This study investigated the incidence of arm lymphoedema following axillary dissection to determine the effect of prospective monitoring and early physiotherapy intervention. Sixty-five women were randomly assigned to either the treatment (TG) or control group (CG) and assessments were made preoperatively, at day 5 and at 1, 3, 6, 12 and 24 months postoperatively. Three measurements were used for the detection of arm lymphoedema: arm circumferences (CIRC), arm volume (VOL) and multi-frequency bioimpedance (MFBIA). Clinically significant lymphoedema was confirmed by an increase of at least 200 ml from the preoperative difference between the two arms. Using this definition, the incidence of lymphoedema at 24 mo. was 21%, with a rate of 11% in the TG compared to 30% in the CG. The CIRC or MFBIA methods failed to detect lymphoedema in up to 50% of women who demonstrated an increase of at least 200 ml in the VOL of the operated arm compared to the unoperated arm. The physiotherapy intervention programme for the TG women included principles for lymphoedema risk minimisation and early management of this condition when it was identified. These strategies appear to reduce the development of secondary lymphoedema and alter its progression in comparison to the CG women. Monitoring of these women is continuing and will determine if these benefits are maintained over a longer period for women with early lymphoedema after breast cancer surgery.
Resumo:
The isotope composition of Ph is difficult to determine accurately due to the lack of a stable normalisation ratio. Double and triple-spike addition techniques provide one solution and presently yield the most accurate measurements. A number of recent studies have claimed that improved accuracy and precision could also be achieved by multi-collector ICP-MS (MC-ICP-MS) Pb-isotope analysis using the addition of Tl of known isotope composition to Pb samples. In this paper, we verify whether the known isotope composition of Tl can be used for correction of mass discrimination of Pb with an extensive dataset for the NIST standard SRM 981, comparison of MC-ICP-MS with TIMS data, and comparison with three isochrons from different geological environments. When all our NIST SRM 981 data are normalised with one constant Tl-205/Tl-203 of 2.38869, the following averages and reproducibilities were obtained: Pb-207/Pb-206=0.91461+/-18; Pb-208/Ph-206 = 2.1674+/-7; and (PbPh)-Pb-206-Ph-204 = 16.941+/-6. These two sigma standard deviations of the mean correspond to 149, 330, and 374 ppm, respectively. Accuracies relative to triple-spike values are 149, 157, and 52 ppm, respectively, and thus well within uncertainties. The largest component of the uncertainties stems from the Ph data alone and is not caused by differential mass discrimination behaviour of Ph and Tl. In routine operation, variation of sample introduction memory and production of isobaric molecular interferences in the spectrometer's collision cell currently appear to be the ultimate limitation to better reproducibility. Comparative study of five different datasets from actual samples (bullets, international rock standards, carbonates, metamorphic minerals, and sulphide minerals) demonstrates that in most cases geological scatter of the sample exceeds the achieved analytical reproducibility. We observe good agreement between TIMS and MC-ICP-MS data for international rock standards but find that such comparison does not constitute the ultimate. test for the validity of the MC-ICP-MS technique. Two attempted isochrons resulted in geological scatter (in one case small) in excess of analytical reproducibility. However, in one case (leached Great Dyke sulphides) we obtained a true isochron (MSWD = 0.63) age of 2578.3 +/- 0.9 Ma, which is identical to and more precise than a recently published U-Pb zircon age (2579 3 Ma) for a Great Dyke websterite [Earth Planet. Sci. Lett. 180 (2000) 1-12]. Reproducibility of this age by means of an isochron we regard as a robust test of accuracy over a wide dynamic range. We show that reliable and accurate Pb-isotope data can be obtained by careful operation of second-generation MC-ICP magnetic sector mass spectrometers. (C) 2002 Elsevier Science B.V. All rights reserved.
Resumo:
This paper introduces a new reconstruction algorithm for electrical impedance tomography. The algorithm assumes that there are two separate regions of conductivity. These regions are represented as eccentric circles. This new algorithm then solves for the location of the eccentric circles. Due to the simple geometry of the forward problem, an analytic technique using conformal mapping and separation of variables has been employed. (C) 2002 John Wiley Sons, Inc.
Resumo:
This present study was undertaken to assess potential effects of cadmium on CYP4A11 apoprotein in human liver and kidney as detected by Western blotting using a highly specific anti-peptide antibody. Liver and kidney cortex samples were autopsy specimens of 37 individuals (26 mates and I I females) whose ages ranged from 3 to 89 years. All were Caucasians who had not been exposed to cadmium in the workplace. Reduced CYP4A11 apoprotein levels were found in chronic hepatitis samples and in liver samples showing fatty changes. In contrast, increased CYP4A11 apoprotein levels were found in liver samples having higher cadmium content compared to the lower cadmium content samples. Increased CYP4A11 levels were also found in liver samples from female donors, compared to male donors; the difference being attributable to higher female liver cadmium burden. In distinction to liver, lowered CYP4A11 levels were seen in the kidney cortex samples which have high cadmium content, It is proposed here that the difference between the absolute cadmium burden of the liver and kidney samples may be responsible for the different patterns of expression of CYP4A11 in these two tissues. Further, since cadmium exposure may be associated with derangement in blood pressure control, it is interesting to note the possible relationship between altered CYP4A11-dependent production of arachidonic acid hydroxy and epoxy metabolites in kidney cortex and altered control of blood pressure. Our findings provide a possible link between these observations. (C) 2002 Elsevier Science Inc. All rights reserved.
Resumo:
We report the first steps of a collaborative project between the University of Queensland, Polyflow, Michelin, SK Chemicals, and RMIT University; on simulation, validation and application of a recently introduced constitutive model designed to describe branched polymers. Whereas much progress has been made on predicting the complex flow behaviour of many - in particular linear - polymers, it sometimes appears difficult to predict simultaneously shear thinning and extensional strain hardening behaviour using traditional constitutive models. Recently a new viscoelastic model based on molecular topology, was proposed by McLeish and Larson (1998). We explore the predictive power of a differential multi-mode version of the pom-pom model for the flow behaviour of two commercial polymer melts: a (long-chain branched) low-density polyethylene (LDPE) and a (linear) high-density polyethylene (HDPE). The model responses are compared to elongational recovery experiments published by Langouche and Debbaut (1999), and start-up of simple shear flow, stress relaxation after simple and reverse step strain experiments carried out in our laboratory.
Resumo:
Objectives: The aims of this study were to investigate the population pharmacokinetics of tacrolimus in adult kidney transplant recipients and to identify factors that explain variability. Methods: Population analysis was performed on retrospective data from 70 patients who received oral tacrolimus twice daily. Morning blood trough concentrations were measured by liquid chromatography-tandem mass spectrometry. Maximum likelihood estimates were sought for apparent clearance (CL/F) and apparent volume of distribution (V/F), with the use of NONMEM (GloboMax LLC, Hanover, Md). Factors screened for influence on these parameters were weight, age, gender, postoperative day, days of tacrolimus therapy, liver function tests, creatinine clearance, hematocrit fraction, corticosteroid dose, and potential interacting drugs. Results. CL/F was greater in patients with abnormally low hematocrit fraction (data from 21 patients only), and it decreased with increasing days of therapy and AST concentrations (P