906 resultados para Minimal surfaces.
Resumo:
Fuel Cells are a promising alternative energy technology. One of the biggest problems that exists in fuel cell is that of water management. A better understanding of wettability characteristics in the fuel cells is needed to alleviate the problem of water management. Contact angle data on gas diffusion layers (GDL) of the fuel cells can be used to characterize the wettability of GDL in fuel cells. A contact angle measurement program has been developed to measure the contact angle of sessile drops from drop images. Digitization of drop images induces pixel errors in the contact angle measurement process. The resulting uncertainty in contact angle measurement has been analyzed. An experimental apparatus has been developed for contact angle measurements at different temperature, with the feature to measure advancing and receding contact angles on gas diffusion layers of fuel cells.
Resumo:
In power electronic basedmicrogrids, the computational requirements needed to implement an optimized online control strategy can be prohibitive. The work presented in this dissertation proposes a generalized method of derivation of geometric manifolds in a dc microgrid that is based on the a-priori computation of the optimal reactions and trajectories for classes of events in a dc microgrid. The proposed states are the stored energies in all the energy storage elements of the dc microgrid and power flowing into them. It is anticipated that calculating a large enough set of dissimilar transient scenarios will also span many scenarios not specifically used to develop the surface. These geometric manifolds will then be used as reference surfaces in any type of controller, such as a sliding mode hysteretic controller. The presence of switched power converters in microgrids involve different control actions for different system events. The control of the switch states of the converters is essential for steady state and transient operations. A digital memory look-up based controller that uses a hysteretic sliding mode control strategy is an effective technique to generate the proper switch states for the converters. An example dcmicrogrid with three dc-dc boost converters and resistive loads is considered for this work. The geometric manifolds are successfully generated for transient events, such as step changes in the loads and the sources. The surfaces corresponding to a specific case of step change in the loads are then used as reference surfaces in an EEPROM for experimentally validating the control strategy. The required switch states corresponding to this specific transient scenario are programmed in the EEPROM as a memory table. This controls the switching of the dc-dc boost converters and drives the system states to the reference manifold. In this work, it is shown that this strategy effectively controls the system for a transient condition such as step changes in the loads for the example case.
Resumo:
Three cycles of erosion have modified the Boulder batholith. The earliest cycle produced a peneplaination that has been largely obliterated by a partially completed intermediate cycle, and the recent cycle now in progress.
Resumo:
OBJECTIVE: The aim of this study was to determine the influence of polyvinyl chloride (PVC) wrapping on the performance of two laser fluorescence devices (LF and LFpen) by assessing tooth occlusal surfaces. BACKGROUND DATA: Protection of their tips may influence LF measurements. To date there are no studies evaluating the influence of this protection on the performance of the LFpen on permanent teeth, or comparing it to the original LF device. MATERIALS AND METHODS: One hundred nineteen permanent molars were assessed by two experienced dentists using the LF and the LFpen devices, both with and without PVC wrapping. The teeth were histologically prepared and assessed for caries extension. RESULTS: The LF values with and without PVC wrapping were significantly different. For both LF devices, the sensitivity and accuracy were lower when the PVC wrapping was used. The specificity was statistically significantly higher for the LFpen with PVC. No difference was found between the areas under the ROC curves with and without PVC wrapping. The ICC showed excellent interexaminer agreement. The Bland and Altman method showed a range between the upper and the lower limits of agreement of 63.4 and 57.8 units for the LF device, and 49.4 and 74.2 for the LFpen device, with and without PVC wrapping, respectively. CONCLUSIONS: We found an influence of the PVC wrapping on the performance of the LF and LFpen devices. However, since its influence on detection of occlusal caries lesions is considered for, the use of one PVC layer is suggested to avoid cross-contamination in clinical practice.
Resumo:
BACKGROUND AND OBJECTIVES: Nerve blocks using local anesthetics are widely used. High volumes are usually injected, which may predispose patients to associated adverse events. Introduction of ultrasound guidance facilitates the reduction of volume, but the minimal effective volume is unknown. In this study, we estimated the 50% effective dose (ED50) and 95% effective dose (ED95) volume of 1% mepivacaine relative to the cross-sectional area of the nerve for an adequate sensory block. METHODS: To reduce the number of healthy volunteers, we used a volume reduction protocol using the up-and-down procedure according to the Dixon average method. The ulnar nerve was scanned at the proximal forearm, and the cross-sectional area was measured by ultrasound. In the first volunteer, a volume of 0.4 mL/mm of nerve cross-sectional area was injected under ultrasound guidance in close proximity to and around the nerve using a multiple injection technique. The volume in the next volunteer was reduced by 0.04 mL/mm in case of complete blockade and augmented by the same amount in case of incomplete sensory blockade within 20 mins. After 3 up-and-down cycles, ED50 and ED95 were estimated. Volunteers and physicians performing the block were blinded to the volume used. RESULTS: A total 17 of volunteers were investigated. The ED50 volume was 0.08 mL/mm (SD, 0.01 mL/mm), and the ED95 volume was 0.11 mL/mm (SD, 0.03 mL/mm). The mean cross-sectional area of the nerves was 6.2 mm (1.0 mm). CONCLUSIONS: Based on the ultrasound measured cross-sectional area and using ultrasound guidance, a mean volume of 0.7 mL represents the ED95 dose of 1% mepivacaine to block the ulnar nerve at the proximal forearm.